• Title/Summary/Keyword: Delta index

Search Result 326, Processing Time 0.038 seconds

ACCRETION-JET MODEL FOR THE HARD X-ray Γ - LX CORRELATION IN BLACK HOLE X-ray BINARIES

  • YANG, QI-XIANG;XIE, FU-GUO;YUAN, FENG;ZDZIARSKI, ANDRZEJ A.;GIERLINSKI, MAREK;HO, LUIS C.;YU, ZHAOLONG
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.565-568
    • /
    • 2015
  • In this work, we study the correlation between the photon index (${\Gamma}$) of the X-ray spectrum and the 2-10 keV X-ray luminosity ($L_X$) for black hole X-ray binaries (BHBs). The BHB sample is mainly from the quiescent, hard and intermediate states, with values of $L_X$ ranging from ${\sim}10^{30.5}$ to $10^{37.5}$ erg $s^{-1}$. We find that the photon index ${\Gamma}$ is positively or negatively correlated with the X-ray luminosity $L_X$, for $L_X$ above or below a critical value, ${\sim}10^{36.5}$ erg $s^{-1}$. This result is consistent with previous works. Moreover, when $L_X{\leq}{\sim}10^{33}$ erg $s^{-1}$, we found that the photon index is roughly independent of the X-ray luminosity. We interpret the above correlations in the framework of a coupled hot accretion flow - jet model. Besides, we also find that in the moderate-luminosity region, different sources may have different anti-correlation slopes, and we argue this diversity is caused by the different value of ${\delta}$, which describes the fraction of turbulent dissipation that directly heats electrons.

Evaluation of Insulation Diagnostic Test Reliability for Stator Winding of High Voltage Induction Motor (고압유도전동기 절연특성시험의 신뢰도 평가)

  • Lee, Kwang-Ho;Kim, Hyun-Il;Kwak, Hee-Jin;Oh, Bong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1838-1841
    • /
    • 2004
  • This test was performed to assess the correlation between insulation diagnostic tests and breakdown voltage strength of the stator winding of 6.6kV class induction motor in insulation deterioration condition which have been in service for 5 years after being installed in 1998. The insulation diagnostic tests include resistance, polarization index(P.I), dissipation factor(${\triangle}tan{\delta}$), maximum partial discharges(Qmax) and AC breakdown test. we evaluated the correlation between insulation diagnostic test and AC breakdown test for stator winding of high voltage induction motor.

  • PDF

Classification of Ellerman bombs

  • Kwak, Hannah;Chae, Jongchul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.87.1-87.1
    • /
    • 2013
  • Ellerman bombs(EB) are small-scale bright features observed best in the wings of H alpha line. We used the Fast Imaging Solar Spectrograph(FISS) with the 1.6m New Solar Telescope at Big Bear Solar Observatory, in order to investigate characteristics of each EB. We analyzed H alpha line profiles of EBs, and classified EBs by their contrast profiles. To analyse characteristics of EBs, we applied power-law fitting ($C={\alpha}{\Delta}{\lambda}^{-n}$) to the EB contrast profiles. The amplitude ${\alpha}$ is a measure of the strength of an EB event (or the amount of released energy), and the power-law index n is a measure of spatial concentration of energy in the higher layers of the solar atmosphere. With the two parameters, we classified EBs into a few groups. We try to understand the physical properties of each group.

  • PDF

Characteristics of Dissipation Factor in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 유전정접 특성)

  • Kim, Hee-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.93-94
    • /
    • 2008
  • Diagnostic tests were performed in three high voltage motors. These tests included insulation resistance, polarization index, ac current, dissipation factor($tan{\delta}$) and partial discharge magnitude. The rewind of motor stator insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. NO.1 and No.2 motors failed near rated voltage of 14.0 kV, respectively. These motors are lower that expected for good quality coils in 6.6 kV class motors. The breakdown voltage of No.3 motor was 15.0 kV.

  • PDF

A Study on Optics and Spectral Energy Distribution Characteristics of LEDs lamp (LED램프의 광학 및 분광분포 특성 연구)

  • Hwang, Myung-Keun;Huh, Chang-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.1
    • /
    • pp.68-75
    • /
    • 2003
  • 본 논문에서는 파랑, 녹색, 호박색 빨강색, 백색 등 고휘도 5mm LED(light emitting diode)의 기본적인 분광분포(SED: spectral energy distribution) 특성을 분석하였으며, LED램프의 중요한 광학 특성인 광속, 효율 피크 파장$({\lambda}p)$, 가중치 평균 파장, 반치폭(FWHM, $\Delta\lambda$), 색도좌표, 주 파장, 자극순도(Pe)와 휘도순도(Pc) 등을 측정 및 실험하였다. 제시된 LED램프의 특성 데이터는 앞으로 LED램프를 사용한 새로운 조명등기구를 개발하는데 많은 도움을 줄 것이며, 이러한 측정 데이터들은 조명용 광원으로서 LED램프의 사용 대체 가능성을 나타낸다.

Enhancement of Off-Axis Viewing Quality with Temporal Dual Gamma Drive in Patterned Vertical Alignment Mode

  • Yang, Young-Chol;Lee, Baek-Woon;Park, Dae-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.286-289
    • /
    • 2006
  • Temporal dual gamma drive technology employing the 120Hz refresh rate was developed to enhance the off-axis viewing quality in patterned vertical alignment mode. The color shift ${\Delta}u'v'$ from on-axis to off-axis (60 deg.) for pale orange color, (R,G,B) = (196,124,96), was below 0.01, and the power exponent of gamma curve for off-axis viewing angle (60 deg.) was about 1.8, when the gamma curve for on-axis was set with power exponent of 2.4. The off-axis image distortion index was below 0.180 in contrast to the normal case ${\sim}0.23$. To elevate the response speed of liquid crystal in the intra-frame, the voltage below threshold voltage of liquid crystals was used.

  • PDF

Fingerprint Matching Using Classify of Minutiae (특징점의 분류를 이용한 지문 정합방법)

  • Kim, Jae-Il;Yang, Ju-Cheng;Park, Dong-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.548-550
    • /
    • 2005
  • 본 논문에서는 지문 인식을 하는데 있어서 특징점의 정보를 이용하여 지문을 정합하는 방법을 제안 하였다. 지문에는 중심점(core point), 삼각주(delta point), 분기점(bifurcation), 단점(ending point)들이 있는데, 본 논문에서는 먼저 poincare index를 이용하여 중심점을 검출한다. 검출된 중심점을 중심으로 하여 관심영역(ROI : region of interest)을 결정하여 영역내의 특징점들을 검출하여, 각 각 특징별로 분류한 다음 중심점과 특징점들과의 관계를 계산하여 지문 정합에 이용한다. 입력 받은 지문은 개개인 각각 양손 모두 10개의 손가락에서 센서의 누르기 압력을 다르게 하여 2번 입력 받아 사용하였다. 실험 결과 기존의 특징점 기반 알고리즘 보다 더 적은 영역에서 좀 더 정확하고 신뢰할 수 있는 지문 정합을 보여줌을 확인 하였다.

  • PDF

Korean Stock Price Index and Macroeconomic Forces (우리나라 증권시장과 거시경제변수 : ANN와 VECM의 설명력 비교)

  • Jung, Sung-Chang;Lee, Timothy H.
    • The Korean Journal of Financial Management
    • /
    • v.19 no.2
    • /
    • pp.211-231
    • /
    • 2002
  • 본 연구의 목적은 VECM(Vector Error Correction Model)과 인공지능모형(Artificial Neural Networks)을 이용하여 우리나라 증권시장과 거시경제 변수들과의 장기적 관계에 대한 설명력을 비교해보고자 함에 있다. VECM이 APT(Arbitrage Pricing Theory)에 기초를 둔 선형동학모형이라고 한다면, 인공지능모형은 비모수적 비선형모형이라는 점에서, 두 방법론의 분석결과를 직접 비판하는 것은 의미있는 연구라고 할 수 있다. 인공지능모형을 주로 활용하는 선행연구들에 의하면, 증권시장은 시장의 특이패턴들로 인해 계량경제학적 접근인 선형 모형보다는 인공지능모형을 통해 증권시장의 움직임을 설명하고 예측하는 것이 더 바람직할 수도 있다는 것이다. 따라서, 본 연구에서는 VECM분석에서 자료의 안정성을 검증하고, 공적분 백터를 발견한 이후, 장기적 균형관계의 실증적 분석을 하였다. 그리고, 인공지능모형에서는 delta rule과 Sigmoid 함수를 이용한 GRNN(General Regression Neural Net)과 Back-Propagation등의 방법들을 활용하였다. 이러한 분석결과, Back-Propagation 모형이 다른 모든 모형들보다도 더 우수한 설명력을 보여주고 있었다. 이러한 결과들은 인공지능모형이 동태적인 선형 모형보다도 더 우수한 설명력을 제공할 수 있는 가능성을 보여주고 있었다.

  • PDF

Design of a Taper-Underlaid Spot-Size Converter with an Offset

  • Choi, Jun-Seok;Oh, Jin-Kyong;Lee, Dong-Hwan;Lee, Hyung-Jong;Kim, Sang-Duk
    • Journal of the Optical Society of Korea
    • /
    • v.11 no.1
    • /
    • pp.40-43
    • /
    • 2007
  • We propose a taper-underlaid spot-size converter (TU-SSC) with an offset which consists of two vertically stacked taper layers. The designed TU-SSC reduces coupling loss of a high index-contrast waveguide with $1.5%{\Delta}$ to a single mode fiber from 1.5 dB to 0.27 dB. We also considered the effects of mask misalignment in the fabrication process of TU-SSC, and optimized the design of TU-SSC so that the additional loss of TU-SSC for the mask misalignment of $3{\mu}m$ in the photo-lithography process was as low as 0.13 dB.

Assessment of Insulation Condition for Hydro-generator (대용량 수치발전기의 절연진단에 의한 절연상태평가)

  • Lee, Kwang-Ho;Park, Jong-Jin;Kim, Ki-Won;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1810-1812
    • /
    • 2002
  • This test was performed to assess the insulation deterioration condition of the stator winding of Chung-Ju hydrogenerator #4 and Dae-Cheong hydrogenerator #2 which had been in service after being constructed 1980. The insulation diagnostic tests include resistance polarization index(P.I.) AC current, dissipation factor(Tan ${\delta}$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to factory test measurements.

  • PDF