• Title/Summary/Keyword: Delivery Method

Search Result 1,943, Processing Time 0.04 seconds

Analysis for Daily Food Delivery & Consumption Trends in the Post-Covid-19 Era through Big Data

  • Jeong, Chan-u;Moon, Yoo-Jin;Hwang, Young-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.1
    • /
    • pp.231-238
    • /
    • 2021
  • In this paper, we suggest a method of analysis for daily food delivery & consumption trends through big data of the post-Covid-19 era. Through analysis of big data and the database system, four analyzed factors, excluding weather, was proved to have significant correlation with delivery sales for 'Baedarui Minjok' of a catering delivery application. The research found that KBS, MBC and SBS Media showed remarkable results in food delivery & consumption sales soaring up to about 60 percent increase on the day after the Covid-19 related new article was issued. In addition, it proved that mobile media and web surfing were the main factors in increasing sales of food delivery & consumption applications, suggesting that viral marketing and emotional analysis by crawling data from SNS used by Millennials might be an important factor in sales growth. It can contribute the companies in the economic recession era to survive by providing the method for analyzing the big data and increasing their sales.

Primiparas만 Perceptions of Their Delivery Experience and Their Maternal-Infant Interaction : Compared According to Delivery Method (초산모의 분만유형별 분만경험에 대한 지각과 모아상호작용 과정에 관한 연구)

  • 조미영
    • Journal of Korean Academy of Nursing
    • /
    • v.20 no.2
    • /
    • pp.153-173
    • /
    • 1990
  • One of the important tasks for new parents. especially mothers, is to establish warm, mutually affirming interpersonal relationships with the new baby in the family, with the purpose of promoting the healthy development of the child and the wellbeing of the whole family. Nurses assess the quality of the behavioral characteristics of the maternal-infant interaction. This study examined the relationships between primiparas pereptions of their delivery experience and their maternal infant interaction. It compared to delivery experience of mothers having a normal vaginal delivery with those having a casearean section. The purpose was to explore the relationships between the mother's perceptions of her delivery experience with her maternal infant interaction. The aim was to contribute to the development of theoretical understanding on which to base care toward promoting the quality of maternal-infant interaction. Data were collected directly by the investigator and a trained associate from Dec. 1, 1987 to March 8, 1988. Subjects were 3 random sample of 62 mothers, 32 who had a normal vaginal delivery and 30 who had a non-elective cesarean section (but without other perinatal complications) at three general hospitals in Seoul. Instruments used were the Stainton Parent -infant Interaction Scale(1981) and the Marut and Mercer Perception of Birth Scale(1979). The first observations were made in the delivery room (for vaginally delivered mothers only), followed by day 1, day 2, day 3, and 2 weeks, 4 weeks, 6 weeks and 8 weeks after birth, for a total of 7-8 contacts(Cesarean section mothers were observed on days 4 and 5 but the data not used for analysis). Observations in the hospital were made during the hour prior to scheduled feedings. The infant was placed beside the mother. Later contacts were made at home. Data analysis was done by computer using as SPSS program and indulded X² test, paired t-test, t-test, and Pearson Correlation coefficient ; the results were as follows. 1. Mothers who had a normal vaginal delivery tended to perceive the delivery experience more positively than cesarean section mothers(p=0.002). The finding supported the hypothesis I that perception of delivery would vary according to the method of delivery. Mothers' perceptions of birth were classified into three dimensions, labor, delivery and the bady. There was a significantly different and positive perception by the vaginally delivered mothers to the delivery experience(p=0.000) but no differences for labor or the bady according to the delivery method(p=0.096, p=0.389), 2. Mothers who had a normal vaginal delivery had higher average maternal-infant interaction scores(p=0.029) than mothers who had a cesarean section. There were similar higher scores for the 1st day(p=0.042), 2nd day (p=0.009), and the 3rd day(p=0.006) after delivery but not for later times. The findings supported the hypothesis Ⅱ that there would be differences in maternal-infant interaction for mothers having vaginal and cesarean section deliveries. However these differences deccreased section deliveries. However these differences decreased over time . by eight weeks the scores for vaginal delivery mothers averaged 8.1 and for cesarean section mothers, 7.9. 3. The more highly positive the pereption of the delivery experience, the higher the maternal-infant interaction score for all subjects(F=.3206, p=.006). The findings supported the hypothesis Ⅲ that there would be correlations between perceptions of delivery and maternal-infant interaction. The maternal infant interaction was highest when the perception of the bady and deliery was positive(r=.4363, p=.000, r=.2881, p=.012). No correlations between perceptions of labor and maternal-infant interaction were found(p=0.062). 4. The daily maternal-infant interaction score for the initial contact after birth to 8 weeks postpartum had the lowest average score 5.20 and the highest 7.98(in a range of 0-10). This subjects group of mothers needed nursing intervention to promote their maternal- infant interaction. The daily scores for the maternal-infant over the period of eight weeks. However, there were significantly different increases in maternal-infant interaction only from the first to second day(p=0.000) and from the fourth to sixth weeks after birth(P=0.000). 5. When the eight items of maternal-infant interaction were evaluated separately, “Expresses feelings about her role as mother” had the highest average score, 1.64(ina range of 0-3)and “Speaks to baby” the lowest, 0.9. All items, with the possible exception of “Expresses feelings about her role as mother”, suggested the subjects' need of nursing intervention to promote maternal-infant interaction. 6. There were positive correlations between certain general charateristis, namely, both a higher economic status(p=0.002) and breast feeding(p=0.202) and maternal - infant interaction. There were positive correlations between a mother's confidence in her role as a mother and the perception of the birth experience(p=0.004). For mothers who had a cesarean section, a positive perception of the birth experience was related to the duration of her marriage(p=0.010), a wanted pregnancy (P=0.030) and her confidence in her role as a mother(p=0.000). Pereptions of birth for mothers who had a normal vaginal delivery were positive than those for mothers who had a cesarean section. The level of maternalinfant interaction for mothers delivered vaginally was higher than for cesarean section mothers. The relationship between perception of birth and materanalinfant interaction was confirmed. Cesarean section has an impact on the mother's perceived experience of birth which, in turn, is positively related to maternal-infant in turn, is positively related to maternal-infant interaction. Nursing intervention to enhance maternal-infant interaction should begin in prenatal classes with an exploration of the potential impact of cesarean section on the perceptions of the birth experience and continue throughout the perinatal and post-natal periods to promote the mother's ability to control with this crisis experience and to mobilize social support. Nursing should help transform a relatively negatively perceived experience into an accepted, positively perceived and self affirming experience which enhances the maternal-infant relationship.

  • PDF

A Practical Method for Designing Vehicle Routing with Time Windows in Warehouse (정시배송체계의 실용적 설계를 위한 방법론)

  • Byeon, Eui-Seok
    • IE interfaces
    • /
    • v.13 no.3
    • /
    • pp.455-461
    • /
    • 2000
  • Logistics systems can be evaluated by how productively distribution center operates, how promptly transportation vehicle dispatches, how efficiently facility layout is, and so on. In this paper, a practical vehicle routing scheme with fixed delivery time and fixed vehicle routes is introduced. The method helps the distribution center reduce logistics cost with respect to dispatching vehicles, and satisfy the customer with pre-determined delivery time window constraints. A case study has shown that the proposed scheme not only generates a feasible schedule with time windows, but also balances material flow in warehouse.

  • PDF

Minimization Method of Reading Error in Postal 4 State Bar Code Reader (우편용 4 State 바코드시스템의 판독오차 최소화 방법)

  • 황재각;신미영;박문성
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.1027-1030
    • /
    • 1999
  • Recently many efforts on the development of automatic processing system for delivery sequence sorting have been performed in ETRI, which requires the use of postal 4 state bar code system to encode delivery points. This paper addresses the issue on the reduction of reading error in postal 4 state raster beam based bar code reader by adjusting measured values of bar code width to its average value over each interval. The test results show that the above method reduces the average reading error rate approximately by 90-100%.

  • PDF

Cationic Emulsions with Galactosylated Chitosan as a Novel Gene Delivery System

  • Choi, Woo-Jeong;Choi, Sung-Hee;Ahn, Woong-Shick;Kim, Chong-Kook
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.427.1-427.1
    • /
    • 2002
  • To improve stability and transfection efficiency, a novel combination of cationic emulsion and galactosylated chitosan was developed for targeted gene delivery. Six formulations of cationic liposome and our novel emulsion were prepared for comparison of stability and transfection efficiency. Cationic liposomes composed of 3[N-(N.N dimethylaminoethylene) carbamoyl] cholesterol (DC-Chol) and dioleyl phophatidyl ethanolamine (DOPE) were prepared by extrusion method and cationic emulsions composed of DC-Chol. DOPE. castor oil, and Tween 80 were prepared by sonication method. (omitted)

  • PDF

A Study on Minimizing the Residual $^{18}F$-FDG in the Tubing Using Nitrogen Gas (FDG 합성 후 질소가스를 이용한 튜빙의 잔류 $^{18}F$-FDG 최소화를 위한 방법의 유용성)

  • Kim, Dong-Il;Park, Hoon;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.8-12
    • /
    • 2010
  • Purpose: In $^{18}F$-FDG automated synthesizer, deliver is done in automated mode after synthesis until the dispenser. After the delivery, the yield is calculated from the radioactivity which was read by the dose calibrator located in the dispenser. However, when the distance between the automated synthesizer and the dispenser is far, there are $^{18}F$-FDG residues, which results in loss of the amount of $^{18}F$-FDG. This study investigated the usefulness of a method that minimizes $^{18}F$-FDG residues. Materials and Methods: The structure of the tubing between the (TRACERlab Mx FDG; GE.) and the dispenser is that the distance is 8 m and the internal diameter is 1/16 inch. The synthesis process of The module goes through the synthesis process of trap, synthesis, delivery in the automated module. The time taken for synthesis is about 25 to 26 minutes, after which rinsing is done. However, after rinsing, as the distance of the tubing increased, there were 10~13% of $^{18}F$-FDG residues. Therefore, a method of using push syringe and $N_2$ gas in manual mode to minimize $^{18}F$-FDG residues is analyzed. Results: In manual mode, there were $^{18}F$-FDG residues of 4~5% for the push syringe, and there were $^{18}F$-FDG residues of less than 1% for the $N_2$ gas, which showed that the method using $N_2$ gas had superior usefulness. Also, there were no $^{18}F$-FDG residues in the cleaning the next day. Conclusion: The distance between the synthesizer and the dispenser needs to be reduced as much as possible, to reduce the rate of loss of $^{18}F$-FDG resulting from the distance of the tubing. However, in case the distance between the synthesizer and the dispenser has to be increased due to the system structure, using push syringe and $N_2$ gas simultaneously is a useful method for minimizing $^{18}F$-FDG residues.

  • PDF

A Part Release Method Considering Tool Scheduling in FMS (FMS에서 공구 일정계획을 고려한 부품투입 방법)

  • 이충수;최정상
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 2003
  • A recent trend In flexible manufacturing systems (FMS) Is to utilize the Identical versatile machines with fast tool delivery devices. Unlike a conventional FMS where parts are fed to the machines with the required tools, tools are acquired from other machines using a tool delivery system and parts can be finished on the same machine In these FMS. Therefore it Is more important problem 4o plan tool flow using tool delivery system In these FMS rather than part flow In conventional FMS. According to the existing study, In FMS 20∼30 percent of the total management cost Is the cost related with tools and It Is possible to reduce the tool Inventory by 40 percent using efficient tool allocation. In this study, In FMS under dynamic tool allocation strategy, a new method of part release considering tool flow at the stage of part release Is proposed. In order to prove the efficiency of the proposed part release It is compared with other part release through simulation experiments. Performance measures in these experiments are the throughput and the number of tardy parts.

Endovascular Rescue Method for Undesirably Stretched Coil

  • Cho, Jae Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.4
    • /
    • pp.364-367
    • /
    • 2014
  • Undesirable detachment or stretching of coils within the parent artery during aneurysm embolization can be related with thrombus formation, which can be caused occlusion of parent artery or embolic event(s). To escape from this situation, several rescue methods have been reported. A case with undesirably stretched coil in which another rescue method was used, is presented. When the stretched coil is still located in the coil delivery microcatheter, the stretched coil can be removed safely using a snare and a handmade monorail microcatheter. After a snare is lodged in the handmade monorail microcatheter, the snare is introduced over the coil delivery micorcatheter and located in the distal part of the stretched coil. After then, the handmade monorail microcatheter captures the stretched coil and the snare as one unit. This technique using a handmade monorail microcatheter and a snare can be a good rescue modality for the undesirably stretched coil, still remained within the coil delivery microcatheter.

Highly Efficient Encapsulation of Anionic Small Molecules in Asymmetric Liposome Particles

  • Lee, Myung Kyu
    • Applied Science and Convergence Technology
    • /
    • v.24 no.6
    • /
    • pp.284-288
    • /
    • 2015
  • Anionic small molecules are hard to penetrate the cell membranes because of their negative charges. Encapsulation of small molecules into liposome particles can provide target specific delivery of them. In our previous study, siRNA could be efficiently encapsulated into liposome particles using an asymmetric preparation method of liposomes. In this study, the same method was applied for encapsulation of small anionic fluorescent chemicals such as calcein and indocyanine green (ICG). More than 90% fluorescent chemicals were encapsulated in the asymmetric liposome particles (ALPs). No intracellular fluorescent signal was observed in the tumor cells treated with the unmodified calcein/ALPs and ICG/ALPs, whereas the surface modification with a cell-penetrating polyarginine peptide (R8 or R12) allows cellular uptake of the ALPs. The results demonstrate that the ALPs encapsulating small anionic drugs will be useful for target-specific delivery after modification of target-specific ligands.

SDN-based Hybrid Distributed Mobility Management

  • Wie, Sunghong
    • Journal of information and communication convergence engineering
    • /
    • v.17 no.2
    • /
    • pp.97-104
    • /
    • 2019
  • Distributed mobility management (DMM) does not use a centralized device. Its mobility functions are distributed among routers; therefore, the mobility services are not limited to the performance and reliability of specific mobility management equipment. The DMM scheme has been studied as a partially distributed architecture, which distributes only a packet delivery domain in combination with the software defined network (SDN) technology that separates the packet delivery and control areas. Particularly, a separated control area is advantageous in introducing a new service, thereby optimizing the network by recognizing the entire network situation and taking an optimal decision. The SDN-based mobility management scheme is studied as a method to optimize the packet delivery path whenever a mobile node moves; however, it results in excessive signaling processing cost. To reduce the high signaling cost, we propose a hybrid distributed mobility management method and analyze its performance mathematically.