• Title/Summary/Keyword: Delay M9

Search Result 203, Processing Time 0.027 seconds

A 40 MHz to 280 MHz 32-phase CMOS 0.11-${\mu}m$ Delay-Locked Loop (40MHz ~ 280MHz의 동작 주파수와 32개의 위상을 가지는 CMOS 0.11-${\mu}m$ 지연 고정 루프)

  • Lee, Kwang-Hun;Jang, Young-Chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.95-98
    • /
    • 2012
  • This paper describes a multiphase delay-locked loop (DLL) that generates a 32-phase output clock over the operating frequency range of 40 MHz to 280 MHz. The matrix-based delay line is used for high resolution of 1-bit delay. A calibration scheme, which improves the linearity of a delay line, is achieved by calibrating the nonlinearity of the input stage of the matrix. The multi-phase DLL is fabricated by using 0.11-${\mu}m$ CMOS process with a 1.2 V supply. At the operating frequency of 125MHz, the measurement results shows that the DNL is less than +0.51/-0.12 LSB, and the measured peak-to-peak jitter of the multi-phase DLL is 30 ps with input peak-to-peak jitter of 12.9 ps. The area and power consumption of the implemented DLL are $480{\times}550{\mu}m^2$ and 9.6 mW at the supply voltage of 1.2 V, respectively.

  • PDF

A Study on Reliability and Shelf-Life of DELAY M9 (DELAY M9 탄약의 신뢰도 및 저장수명 연구)

  • Lee, Jeong-Ho;Choi, Jae-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.64-72
    • /
    • 2020
  • DELAY M9 is an ammunition used in combination with the fuse M904 and M905 of aviation drop-off ammunitions. Due to the properties of the ammunition, the performance or safety of the ammunition cannot be verified until it is used, because of its one-time function, no reproduction and is finally destroyed at the same time. Long-term storage of ammunition in use by the army is inevitable due to its operational characteristics, and a test evaluation is required to maintain and verify the performance of stored ammunition for immediate use in case of emergency. This paper estimates the reliability and shelf life of the DELAY M9 ammunition by using the test data obtained through ASRP performed from the past to the present. The result of the performance evaluation test for the currently stored DELAY M9 ammunition is analyzed, and the reliability and shelf-life of the stored ammunition are assessed by examining the number of defects according to the storage time and production year. This research result can be used to manage the stored ammunition, such as ASRP planning and evaluation test, result analysis and munition state decision.

Factors Delaying Presentation of Sudanese Breast Cancer Patients: an Analysis Using Andersen's Model

  • Salih, Alaaddin M;Alfaki, Musab M;Alam-Elhuda, Dafallah M;Nouradyem, Momin M
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.2105-2110
    • /
    • 2016
  • Purpose: A multicenter, observational, cross-sectional study was conducted to assess factors delaying presentation of breast cancer cases. Materials and Methods: Data were collected from a pair of highly specialized referral centers, both located in the center of the Sudanese capital, Khartoum. For a total of 153 eligible respondents, durations of delay, clinicodemographic factors and reasons of referral were collected from our respondents through self-administered questionnaires. Logistic regression analysis and ANOVA were used to test the relation between periods of delay and different factors. Odd ratios (OR's) and their correspondent Confidence intervals (95% CI's). Delay periods were studied with Andersen's model. Results: The average duration of delay in our study was 11.9 (${\pm}11.2$) months. Only a quarter of our patients presented early within the first 3 months after onset of their symptoms. About 47.7% arrived later during the course of the first year, while it took beyond that for the last 27% to come. A prior diagnosis of BC was the only predictor of early presentation (for 3-12 months OR=9.6 (p<0.00), 95% CI 9.55-9.75; for >12 months OR=9.3 (p<0.00), 95% CI 9.33-9.33). Out of the 12 different reasons for delay given by our respondents, none showed a significant difference between patients presenting early or late. Financial incapacity (17.5%), ignorance about BC (14.3), and misinterpreting symptoms (12.7%) were the top three whys of delay. Conclusions: Our findings support existence of a non-uniform pattern of delay among Sudanese BC patients. Changing currently adopted awareness elevating strategies into much more inclusive approaches is strongly recommended.

Performance-based Channel Scheduler for AMC/TDM Wireless Network System (AMC/TDM 무선 데이터 통신에서의 성능보장형 채널스케줄러)

  • 이종훈;김동구
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.6B
    • /
    • pp.586-592
    • /
    • 2002
  • In this paper, new channel scheduling algorithms which reduce transmission delay caused by wireless network are proposed in AMC/TDM wireless data communication. The concept of the Proposed algorithms is based on the proportional fairness, M-LWDF, and performance-guaranteeing algorithm proposed by Xin Liu. The proposed algorithm can be applied to QoS guaranteeing services as well as best-effort services. Simulation results show that new algorithm reduced transmission delay upto 11.5% in case of proportional fairness algorithm and also decreased transmission delay unto 9% in case of M-LWBF algorithm.

A 125 MHz CMOS Delay-Locked Loop with 32-phase Output Clock (32 위상의 출력 클럭을 가지는 125 MHz CMOS 지연 고정 루프)

  • Lee, Kwang-Hun;Jang, Young-Chan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.1
    • /
    • pp.137-144
    • /
    • 2013
  • A delay-locked loop (DLL) that generates a 32-phase clock with the operating frequency of 125 MHz is introduced. The proposed DLL uses a delay line of $4{\times}8$ matrix architecture to improve a differential non-linearity (DNL) of the delay line. Furthermore, a integral non-linearity (INL) of the proposed DLL is improved by calibrating phases of clocks that is supplied to four points of an input stage of the $4{\times}8$ matrix delay line. The proposed DLL is fabricated by using $0.11-{\mu}m$ CMOS process with a 1.2 V supply. The measured operating frequency range of the implemented DLL is 40 MHz to 280 MHz. At the operating frequency of 125MHz, the measurement results shows that the DNL and INL are +0.14/-0.496 LSB and +0.46/-0.404 LSB, respectively. The measured peak-to-peak jitter of the output clock is 30 ps when the peak-to-peak jitter of the input clock is 12.9 ps. The area and power consumption of the implemented DLL are $480{\times}550{\mu}m^2$ and 9.6 mW, respectively.

Design of the 1.9-GHz CMOS Ring Voltage Controlled Oscillator using VCO-gain-controlled delay cell (이득 제어 지연 단을 이용한 1.9-GHz 저 위상잡음 CMOS 링 전압 제어 발진기의 설계)

  • Han, Yun-Tack;Kim, Won;Yoon, Kwang-Sub
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.4
    • /
    • pp.72-78
    • /
    • 2009
  • This paper proposes a low phase noise ring voltage controlled oscillator(VCO) with a standard $0.13{\mu}m$ CMOS process for PLL circuit using the VCO-gain-controlled Delay cell. The proposed Delay cell architecture with a active resistor using a MOS transistor. This method can reduced a VCO gain so that improve phase noise. And, Delay cell consist of Wide-Swing Cascode current mirror, Positive Latch and Symmetric load for low phase noise. The measurement results demonstrate that the phase noise is -119dBc/Hz at 1MHz offset from 1.9GHz. The VCO gain and power dissipation are 440MHz/V and 9mW, respectively.

Fabrication of an On System based on an Optical Delay line with Cylindrical PZT (실린더형 압전소자 광지연선을 이용한 광 간섭형 단층촬영(OCT) 시스템 제작)

  • Park, Sung-Jin;Kim, Young-Kwan;Kim, Yong-Pyung
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.159-164
    • /
    • 2006
  • We demonstrate a compact optical coherence tomography(OCT) system based on the optical fiber delay line controlled by a cylindrical piezo-electric transducer(PZT). An 18-m length of single mode fiber is wrapped under constant tension around a PZT. Approximately 134 windings are used. Wraps of the long length of fiber allow the small expansion of the PZT to be magnified to an optical path length delay of 0.78 m. The OCT system shows characteristics for 2-dimensional imaging, exhibiting 96.9dB of signal-to-noise ratio(SNR), $18.6{\pm}0.5\;{\mu}m$ of axial resolution, and $5\;{\mu}m$ of lateral resolution with samples.

The Algorithm of Efficient Core Selection Estimation for the Multicast Delay Variation Problem and Minimum Delay Variation (멀티캐스트 지연변이 문제에 대한 효율적인 코어 선택 추정 알고리즘)

  • Ahn, Youn-Gjin;Kim, Moon-Seong;Choo, Hyun-Seung
    • Journal of Internet Computing and Services
    • /
    • v.8 no.2
    • /
    • pp.33-41
    • /
    • 2007
  • With the development of the multicast technology, the realtime strategy among the group applications using the multicast routing is getting more important. An essential factor of these real-time application is to optimize the Delay- and delay Variation-Bounded Multicast Tree(DVBMT) problem. This problem is to satisfy the minimum delay variation and the end-to-end delay within an upper bound. The DVBMT problem is known as NP-complete problem. The representative algorithms for the problem are DVMA, DDVCA, and so on. In this paper, we show that the proposed algorithm outperforms any other algorithm. The efficiency of our algorithm is verified through the prerformance evaluation and the enhancement is up to about 9% to 29% in terms of the multicast delay variation. The time complexity of our algorithm is $O(mn^2)$M.

  • PDF

Consideration of Normal Variation of Perfusion Measurements in the Quantitative Analysis of Myocardial Perfusion SPECT: Usefulness in Assessment of Viable Myocardium (심근관류 SPECT의 정량적 분석에서 관류정량값 정상변이의 고려: 생존심근 평가에서의 유용성)

  • Paeng, Jin-Chul;Lim, Il-Han;Kim, Ki-Bong;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.285-291
    • /
    • 2008
  • Purpose: Although automatic quantification software of myocardial perfusion SPECT provides highly objective and reproducible quantitative measurements, there is still some limitation in the direct use of quantitative measurements. In this study we derived parameters using normal variation of perfusion measurements, and tried to test the usefulness of these parameters. Materials and Methods: In order to calculate normal variation of perfusion measurements on myocardial perfusion SPECT, 55 patients (M:F = 28:27) of low-likelihood for coronary artery disease were enrolled and $^{201}TI$ rest/$^{99m}Tc$-MIBI stress SPECT studies were performed. Using 20-segment model, mean (m) and standard deviation (SD) of perfusion were calculated in each segment. As a myocardial viability assessment group, another 48 patients with known coronary artery disease, who underwent coronary artery bypass graft surgery (CABG) were enrolled. $^{201}TI$ rest/$^{99m}Tc$-MIBI stress / $^{201}TI$ 24-hr delayed SPECT was performed before CABG and SPECT was followed up 3 months after CABG. From the preoperative 24-hr delayed SPECT, $Q_{delay}$ (perfusion measurement), ${\Delta}_{delay}$ ($Q_{delay}$ - m) and $Z_{delay}$ (($Q_{delay}$ - m)/SD) were defined and diagnostic performances of them for myocardial viability were evaluated using area under curve (AUC) on receiver operating characteristic (ROC) curve analysis. Results: Segmental perfusion measurements showed considerable normal variations among segments. In men, the lowest segmental perfusion measurement was $51.8{\pm}6.5$ and the highest segmental perfusion was $87.0{\pm}5.9$, and they are $58.7{\pm}8.1$ and $87.3{\pm}6.0$, respectively in women. In the viability assessment $Q_{delay}$ showed AUC of 0.633, while those for ${\Delta}_{delay}$ and $Z_{delay}$ were 0.735 and 0.716, respectively. The AUCs of ${\Delta}_{delay}$ and $Z_{delay}$ were significantly higher than that of $Q_{delay}$ (p = 0.001 and 0.018, respectively). The diagnostic performance of ${\Delta}_{delay}$, which showed highest AUC, was 85% of sensitivity and 53% of specificity at the optimal cutoff of -24.7. Conclusion: On automatic quantification of myocardial perfusion SPECT, the normal variation of perfusion measurements were considerable among segments. In the viability assessment, the parameters considering normal variation showed better diagnostic performance than the direct perfusion measurement. This study suggests that consideration of normal variation is important in the analysis of measurements on quantitative myocardial perfusion SPECT.

On the long-term stability of the Y4KCam shutter

  • Lee, Jae-Woo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.82.1-82.1
    • /
    • 2015
  • We investigate the long-term spatial drift of the center and the temporal variation of the shutter delay time map of Y4KCam mounted on the CTIO 1.0m telescope. We have collected shutter delay time maps for over 7 years as a part of long-term survey program. We find that the center of the shutter delay time map can drift up to $450{\mu}m$ on the CCD. This effect can result in a small amount of error unless the proper shutter delay time correction, but it does not appear to cause any significant problems in photometric measurements. We obtain the mean value of the shutter delay time of $69.1{\pm}0.9$ msec and find no temporal variation of the shutter delay time of Y4KCam for over 7 years, indicative of the mechanical stability of the shutter. We suggest that using a master shutter delay time correction frame would be sufficient to achieve high precision photometry and this does not add up errors more than ~ 2.5 mmag across the CCD frame with exposure times longer than 1 sec.

  • PDF