• 제목/요약/키워드: Degraded Control

검색결과 408건 처리시간 0.029초

양자화 재생레벨 조정을 통한 DCT 영상 코오딩에서의 블록화 현상 감소 방법 (A Quantizer Reconstruction Level Control Method for Block Artifact Reduction in DCT Image Coding)

  • 김종훈;황찬식;심영석
    • 전자공학회논문지B
    • /
    • 제28B권5호
    • /
    • pp.318-326
    • /
    • 1991
  • A Quantizer reconstruction level control method for block artifact reduction in DCT image coding is described. In our scheme, quantizer reconstruction level control is obtained by adding quantization level step size to the optimum quantization level in the direction of reducing the block artifact by minimizing the mean square error(MSE) and error difference(EDF) distribution in boundary without the other additional bits. In simulation results, although the performance in terms of signal to noise ratio is degraded by a little amount, mean square of error difference at block boundary and mean square error having relation block artifact is greatly reduced. Subjective image qualities are improved compared with other block artifact reduction method such as postprocessing by filtering and trasform coding by block overlapping. But the addition calculations of 1-dimensional DCT become to be more necessary to coding process for determining the reconstruction level.

  • PDF

전원 전압 불평형시 계통연계형 인버터의 유효전력 리플 억제를 위한 듀얼 전류제어기 구현과 출력 전력의 실시간 제한 알고리즘 (Implementation of Dual Current Controller and Realtime Power Limiting Algorithm in Grid-connected Inverter during Unbalanced Voltage Conditions)

  • 송승호;김정재
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권1호
    • /
    • pp.54-60
    • /
    • 2006
  • A power limiting algorithm is proposed for stable operation of grid-connected inverter in case of grid voltage unbalance considering the operation limit of inverter. During the voltage unbalance the control performance of Inverter. is degraded and the output power contains 120Hz ripple due to the negative sequence of voltage. In this paper, conventional dual sequence current controller is implemented to solve these problems using separated control of positive and negative sequence. Especially the maximum power limit which guarantees the maximum rated current of the inverter is automatically calculated as the instant grid voltage changes. As soon as the voltage recovers the proposed algorithm can return to the normal power control mode accomplishing low voltage ride through. Proposed algorithm is verifed using PSCAD/EMTDC simulations and tested experimentally at 4.4kW wind turbine simulator set-up.

고확장성 SDN을 위한 랭킹 기반 플로우 교체 기법 (Ranking-based Flow Replacement Method for Highly Scalable SDN)

  • 뉘엔 트리 투안 힙;김경백
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2015년도 춘계학술발표대회
    • /
    • pp.143-146
    • /
    • 2015
  • Software Defined Network (SDN) separates control plane and data plane to achieve benefits such as centralized management, centralized provisioning, lower device cost and more flexibility. In SDN, scalability is an important issue. Centralized controller can be a bottle neck and many research tried to solve this issue on the control plan. However, scalability issue does not only happen in the control plane, but also happen in the data plane. In the data plane, flow table is an important component and its size is limited. In a large network operated by SDN technology, the performance of the network can be highly degraded because of the size limitation of a flow table. In this paper, we propose a ranking-based flow replacement method, Flow Table Management (FTM), to overcome this problem.

DEVELOPMENT OF A RECONFIGURABLE CONTROL FOR AN SP-100 SPACE REACTOR

  • Na Man-Gyun;Upadhyaya Belle R.
    • Nuclear Engineering and Technology
    • /
    • 제39권1호
    • /
    • pp.63-74
    • /
    • 2007
  • In this paper, a reconfigurable controller consisting of a normal controller and a standby controller is designed to control the thermoelectric (TE) power in the SP-100 space reactor. The normal controller uses a model predictive control (MPC) method where the future TE power is predicted by using support vector regression. A genetic algorithm that can effectively accomplish multiple objectives is used to optimize the normal controller. The performance of the normal controller depends on the capability of predicting the future TE power. Therefore, if the prediction performance is degraded, the proportional-integral (PI) controller of the standby controller begins to work instead of the normal controller. Performance deterioration is detected by a sequential probability ratio test (SPRT). A lumped parameter simulation model of the SP-100 nuclear space reactor is used to verify the proposed reconfigurable controller. The results of numerical simulations to assess the performance of the proposed controller show that the TE generator power level controlled by the proposed reconfigurable controller could track the target power level effectively, satisfying all control constraints. Furthermore, the normal controller is automatically switched to the standby controller when the performance of the normal controller degrades.

축산물 중 Thiodicarb와 대사산물 Methomyl의 동시분석법개발 (Development of Simultaneous Analytical Method for Thiodicarb and its Metabolite Methomyl in Livestock Products)

  • 장희라;유정선;반선우;곽혜민
    • 한국환경농학회지
    • /
    • 제40권2호
    • /
    • pp.142-147
    • /
    • 2021
  • BACKGROUND: Agricultural use and pest control purposes of pesticides may lead to livestock products contamination. Thiodicarb and its degraded product, methomyl, are carbamate insecticides that protect soya bean, maize, fruit, and vegetables and control flies in animal and poultry farms. For maximum residue limit enforcement and monitoring, the JMPR residue definition of thiodicarb in animal products is the sum of thiodicarb and methomyl, expressed as methomyl. This residue definition was set to consider the fact that thiodicarb was readily degraded to methomyl in animal commodities. And therefore the simultaneous analytical method of thiodicarb and methomyl is required for monitoring in livestock products. METHODS AND RESULTS: The study was conducted using a quick, easy, cheap, effective, rugged, and safe (QuEChERS) method and HPLC-MS/MS to determine the thiodicarb and methomyl in livestock products. The limit of quantitation (LOQ) was 0.01 mg/kg for livestock products, including beef, pork, chicken, milk, and egg. The coefficient of determinations (r2) for the calibration curve were > 0.99, which was acceptable values for linearity. Average recoveries at spiked levels (LOQ, 10LOQ, and 50LOQ, n=5) in triplicate ranged from 73.2% to 102.1% and relative standard deviations (RSDs) were less than 10% in all matrices. CONCLUSION: The analytical method was validated for the performance parameters (specificity, linearity, accuracy, and precision) in livestock products to be acceptable by the CODEX guidelines.

일본 아시오(足尾) 銅鑛山地域의 삼림황폐와 삼림환경 복구사업에 관한 분석 (Forest Environment Degradation and Rehabilitation of Copper Mine Area in Ashio, Japan)

    • 한국환경생태학회지
    • /
    • 제15권3호
    • /
    • pp.276-285
    • /
    • 2001
  • 1880년대에 이미 대기오염물질에 의한 대규모 삼림이 황폐되었고. 그 후에 이를 복구하기 위해 막대한 예산을 투자하고 있는 일본 아시오(足尾) 지역을 대상으로 삼림황폐와 황폐산지 복구사업 현황을 분석하였다. 삼림황폐의 원인은 구리 제련과정에서 배출되는 아황산가스. 제련과 광산용 목재의 남벌 대형 산불 험준한 지형 불리한 기후조건 등의 복합적인 작용으로 분석할 수 있다. 1897년부터 3년 동안 2,399ha의 식수사업을 비롯한 황폐삼림의 복구사업이 지속적으로 추진되었으나, 삼림황폐와 재해발생이 계속되어 1956년에 황폐산지의 총면적은 2,400~3,000ha이었다. 1945년부터 1996년까지$\ulcorner$인력에 의한 방법$\lrcorner$, $\ulcorner$헬리콥터에 의한 방법$\lrcorner$, $\ulcorner$인력과 헬리콥터 조합방법$\lrcorner$에 의한 시공으로 산복 828.19ha와 계간 133개소에 복구공사를 실행하였다. 예산은 약 800억 엔이 투자되었다. 주요 복구공법은 기초공사로서 사방댐과 흙막이공사, 녹화공사로서 식생반공법과 식생대공법 및 식재 공법이며, 인력에 의한 3단계 시공으로 장소별 완전복구를 목표로 하고 있다. 전반적으로 시공지의 녹화율은 약 49% 정도이며. 완전히 녹화된 비율은 전체 시공지의 10%에도 미치지 못한 실정이다. 남아 있는 황폐산지에 대하여 향후 25년 동안 약 213억 엔을 투입하여 산복공사 564ha, 계간공사 183개소를 복구할 계획이지만. 완전히 복구하는 데에는 몇 년이 걸릴지 예측할 수 없는 상황이다. 이곳에서의 황폐산림 복구공법은 우리 나라의 폐광지 산비탈을 복구하는 데에 적용할 수 있을 것으로 기대된다.

  • PDF

파라메터오차 및 모달필터오차에 대한 독립모달공간 제어기법의 강인성 해석 (Robustness of Independent Modal Space Control for Parameter and Modal Filter Errors)

  • 황재혁;김준수
    • 대한기계학회논문집A
    • /
    • 제20권11호
    • /
    • pp.3549-3559
    • /
    • 1996
  • In this study, the effect of parameter and modal filter errors on the vibration control characteristics of flexible structures is analyzed for IMSC ( Independent Modal Space Control). If the control force is designed on the basis of the mathematical model with the parameter and modal filter errors, the closed-loop performance of the vibration control system will be degraded depending on the magnitude of the errors. An asymptotic stability condition of the system with parameter and modal filter errors has more significant effect on the stability condition of the system with parameter and modal filter errors has been drived using Lyapunov approach. It has been found that modal filter error has more significant effect on the stability of closed-loop system than parameter error does. The extent of the response deviation of the closed-loop system is also derived and evaluated using operator thchniques.

긴 전달관로를 갖는 공압제어계의 압력 제어 (Pressure Control of a Pneumatic Conrol system with a long Transmission Line)

  • 장지성;이광국;최명수
    • 대한기계학회논문집A
    • /
    • 제27권4호
    • /
    • pp.567-576
    • /
    • 2003
  • In this study, a robust controller to control pressure in a pneumatic pressure vessel with a long transmission line is proposed. Frequency response of transmission line using compressible fluid is changed by the flowing state of the fluid. So, it a fixed gain controller designed based on a model supposed the flowing state to a specific state, the performance of the control system could be degraded because of the modelling error. The controller designed in this study is composed of two parts. One is a feedback controller to improve a feedback characteristics and to compensate the influence of the variation of transfer characteristics of a transmission line owing to the change of flowing state and the other is a feedforward controller to regulate command fallowing performance. The experimental results with the designed controller show that the robustness of the control system is achieved regardless of the change of the model or the transmission line. Therefore, the designed controller can be utilized for the Performance improvement of a Pressure control system with a long transmission line using compressible fluid.

서보 드라이브 성능 향상을 위한 AC 서보 전동기의 적응형 전류 제어 (An Adoptive Current Control Scheme of an AC Servo Motor for Performance Improvement of a Servo Drive)

  • 김경화
    • 조명전기설비학회논문지
    • /
    • 제20권6호
    • /
    • pp.96-103
    • /
    • 2006
  • 서보 드라이브의 성능 향상을 위해 AC 서보 전동기의 MRAC (Model Reference Adaptive Control) 기반 적응 전류 제어 기법이 제시된다. 인버터 구동 전류 제어 기법 중 예측형 전류 제어 기법은 이상적인 과도 응답 및 정상 상태 응답을 주지만, 전동기 파라미터 변화 시 정상상태 응답 성능이 저하된다. 이러한 제한 점을 극복하기 위해 파라미터 변화에 의한 외란이 MRAC 기법에 의해 추정되어 전향 제어에 의해 보상된다. 제안된 방식은 기존의 외란 추정 방식과 달리 관측기 구성을 위한 인버터의 상전압 측정을 필요로 하지 않는다. 제안된 적응 제어 방식의 점근안정성과 효과적으로 서보 드라이브에 적용될 수 있음이 입증된다. 제안된 방식이 DSP TMS320C31을 이용하여 구현되고 유용성이 시뮬레이션과 실험을 통해 입증된다.

아스콜빈산에 의한 Aflatoxin $B_1$의 파괴에 관한 연구 (Effect of L-ascorbic acid on the degradation of aflatoxin $B_1$)

  • 박건영;권미향
    • 한국식품영양과학회지
    • /
    • 제16권1호
    • /
    • pp.1-9
    • /
    • 1987
  • $AFB_1$과 아스콜빈산(AA)이 산성 $pH(pH1{\sim}7)$에서 반응하는 동안 ($37^{\circ}C$에서 5일간) 상당량의 $AFB_1$가 파괴되었다. 반응기간 중 $AFB_1$$pH5{\sim}7$ 사이에서 대조군의 경우 거의 파괴되지 않았는데 AA 존재할 때 5일 후 $50{\sim}60%$가 파괴되었다. pH4 이하에서는 대조군 자체에서도 pH가 낮아지면서 $AFB_1$의 파괴가 증가되었지만 AA 존재하에서는 그 파괴량도 증가되었을 뿐 아니라, pH가 떨어질수록 속도도 증가했다. $AFB_1$이 AA와 반응했을 때 온도가 증가함에 따라 $AFB_1$량이 점차 감소하여 $60^{\circ}C$에서 반응할 때는 3일 후에 전혀 $AFB_1$을 발견하지 못했지만 $5^{\circ}C$에서는 반응기간 중 $AFB_1$은 안정 했다. $AFB_1$이 산화제$(CuSO_4{\cdot}5H_2O)$가 첨가된 AA와 반응했을 때 그 반응속도는 급격히 증가되어 $90{\sim}96%$$AFB_1$이 파괴되었으며, 대조군의 4%만이 파괴된 것과는 대조적이었다. 환원제 L-cysteine을 첨가했을 때 하루 동안 $AFB_1$의 파괴는 거의 없었으며 반응기간 중 대조군보다 소량의 $AFB_1$이 파괴되었다. $AFB_1$의 파괴는 AA의 농도에 따라 달랐는데 AA농도가 감소할수록 파괴 속도가 감소했지만 $AFB_1$의 농도는 이 파괴 반응에 영향을 주지 못했다. $AFB_1$과 AA가 반응하여 새로이 생성된 반응물은 TLC, RPLC 및 UV spectrophotometer를 이용하였을 때 $AFB_2a$로 동정되었으며, $AFB_1$의 분해와 더불어 $AFB_2a$의 생성이 확인되었다. 이 실험 결과에 비추어 AA 존재시 $AFB_1$의 파괴는 AA 산화기간 중 생성된 산화 생성물에 의한 것으로 추정된다.

  • PDF