• 제목/요약/키워드: Deformation Coupling

검색결과 254건 처리시간 0.028초

Difference analysis of the collapse behaviors of the single-story beam-column assembly and multi-story planar frame

  • Zheng Tan;Wei-Hui Zhong;Bao Meng;Xing-You Yao;Yu-Hui Zheng;Yao Gao;Shi-Chao Duan
    • Steel and Composite Structures
    • /
    • 제50권3호
    • /
    • pp.265-280
    • /
    • 2024
  • The collapse behavior observed in single-story beam-column assembly (SSBCA) do not accurately represent the actual overall stress characteristic of multi-story frame structure (MSFS) under column loss scenario owing to ignoring the interaction action among different stories, leading to a disconnection between the anti-collapse behaviors of "components" and "overall structures", that is, the anti-collapse performance of frame structures with two different structural scales has not yet formed a combined force. This paper conducts a numerical and theoretical study to explore the difference of the collapse behaviors of the SSBCA and MSFS, and further to reveal the internal force relationships and boundary constraints at beam ends of models SSBCA and MSFS. Based on the previous experimental tests, the corresponding refined numerical simulation models were established and verified, and comparative analysis on the resistant-collapse performance was carried out, based on the validated modeling methods with considering the actual boundary constraints, and the results illustrates that the collapse behaviors of the SSBCA and MSFS is not a simple multiple relationship. Through numerical simulation and theoretical analysis, the development laws of internal force in each story beam under different boundary constraints was clarified, and the coupling relationship between the bending moment at the most unfavorable section and axial force in the composite beam of different stories of multi story frames with weld cover-plated flange connections was obtained. In addition, considering the effect of the yield performance of adjacent columns on the anti-collapse bearing capacities of the SSBCA and MSFS during the large deformation stages, the calculation formula for the equivalent axial stiffness at the beam ends of each story were provided.

유체 주입에 의한 단층의 수리역학적 거동 해석: 국제공동연구 DECOVALEX-2019 Task B 연구 현황(Step 1) (Hydro-Mechanical Modelling of Fault Slip Induced by Water Injection: DECOVALEX-2019 TASK B (Step 1))

  • 박정욱;박의섭;김태현;이창수;이재원
    • 터널과지하공간
    • /
    • 제28권5호
    • /
    • pp.400-425
    • /
    • 2018
  • 본 논문에서는 국제공동연구인 DECOVALEX-2019 프로젝트 Task B의 연구결과와 현황을 소개하였다. Task B의 주제는 'Fault slip modelling'으로 유체의 주입으로 인해 발생하는 단층의 재활성(미끄러짐, 전단파괴)과 수리역학적 거동을 예측할 수 있는 해석기법을 개발하는 데에 그 목적이 있다. 1단계 연구는 참가팀들이 연구주제에 대해 숙지하고, 벤치마크 모델을 대상으로 단층의 투수특성과 역학적 거동의 상호작용을 모사할 수 있는 해석코드를 개발할 수 있도록 하는 준비 단계의 연구이다. 본 연구에서는 TOUGH-FLAC 연동해석 기법을 사용하여 물 주입으로 인한 단층의 수리역학적 연계거동을 모사하였다. TOUGH2 해석에서는 단층을 Darcy의 법칙과 삼승법칙을 따르는 연속체 요소로 모델링하였으며, FLAC3D 해석에서는 미끄러짐과 개폐가 허용되는 불연속 인터페이스 요소를 통해 모사하였다. 두 가지 수리간극모델에 대하여 수리역학적 커플링 관계식을 수치화하였으며, 연속체 요소(수리모델)와 인터페이스 요소(역학모델)의 거동을 연계할 수 있는 해석기법을 제시하였다. 또한, 단층의 역학적 변형(간극의 변화)으로 인한 수리물성 변화와 기하학적 변화(해석 메쉬의 변형)를 수리해석에 반영할 수 있는 해석기법을 개발하였다. 다양한 압력의 물을 단계적으로 주입하고 이로 인해 유도되는 단층의 탄성거동 및 전단파괴(미끄러짐)에 대해 살펴보았으며, 수리간극의 변화 양상과 원인, 압력 분포와 주입율의 관계 등을 면밀히 검토하였다. 해석 결과, 본 연구에서 개발한 해석기법이 물 주입으로 인한 단층의 미끄러짐 거동을 합리적인 수준에서 재현할 수 있는 것으로 판단할 수 있었다. 본 연구의 해석모델은 Task B에 참여하는 국외 연구팀들과의 의견 교류와 워크숍을 통해 지속적으로 개선하는 한편, 향후 연구의 현장시험에 적용하여 타당성을 검증할 예정이다.

가스하이드레이트 개발과정에서의 단층 재활성화 해석 (Numerical Analysis for Fault Reactivation during Gas Hydrate Production)

  • 김형목;김아람
    • 터널과지하공간
    • /
    • 제26권2호
    • /
    • pp.59-67
    • /
    • 2016
  • 본 논문에서는 해저 하이드레이트 퇴적층에서의 메탄가스 생산 과정에서 발생 가능한 생산정 주변 단층의 재활성화 가능성을 수치해석을 통해 평가하고 재활성화에 따른 미소지진 규모를 예측한 결과를 소개하였다. 가스 생산에 의한 하이드레이트 퇴적층의 유효응력 변화 및 역학적 변형은 TOUGH+Hydrate 코드와 FLAC3D 코드를 순차적으로 연계해석함으로써 시뮬레이션하였다. 단층면 재활성화 기준은 모어쿨롱(Mohr-Coulomb)법칙이 유효한 것으로 가정하였다. 30일간의 시험생산 해석 결과, 감압에 의한 공극압력 감소 및 유효응력의 증가가 주변 단층의 활성화를 일으킬 가능성은 크지 않은 것으로 나타났다. 초기응력 조건에 따른 활성화 가능성을 활동마찰각으로 평가한 결과로부터 수평응력에 비해 수직응력이 상대적으로 큰 정단층 응력조건(normal fault stress regime)에서 단층 재활성화 가능성이 상대적으로 큰 것으로 파악되었다. 또한, 정단층 응력조건에서 단층 재활성화에 기인한 유도지진 발생규모를 모멘트 크기(moment magnitude)로 추정할 경우, 모두 음(-)의 값을 보여 인간이 감지하지 어려운 수준의 미소지진에 해당하는 결과를 보였다. 다만, 본 해석은 하이드레이트 생산과정에서의 단층재활성화 가능성 평가를 목적으로 한 해석기법 구축 및 그 적용성을 소개할 목적으로 상당히 단순화된 지질구조 모델을 가정한 결과이므로, 향후 하이드레이트 시험 생산 및 상업 생산 지역에서의 상세 지질구조, 입력 물성 및 생산 설계조건을 반영한 해석에서는 상이한 결과를 보일 수 있을 것이다.

상온-저온 RF 커플러 유한요소해석 (Finite Element Analysis of RF Coupler in Normal-Low Temperature)

  • 김한솔;이학용;박찬;이재열;임동열;유정훈;현명욱
    • 대한기계학회논문집A
    • /
    • 제38권10호
    • /
    • pp.1101-1107
    • /
    • 2014
  • 중이온 입자가속기는 중이온을 radio frequency (RF) 주파수로 가속하는 장치이다. RF 공동부에 인가된 전기장은 입력된 RF 파에 의해 전자기파의 위상에 맞춰 중이온을 연속적으로 가속한다. 이를 위해서는 안정적으로 RF 파를 공동부 내부에 전달할 수 있는 커플러의 형상설계가 요구된다. 중이온 가속기에서의 RF 커플러는 입력부와 RF 주파수의 파를 방출하는 커플러 양 끝단 간의 온도차이가 매우 크다. 이 온도차를 극복하기 위해선 초저온(약 0K)부터 상온 간(약 300K)의 열 변형을 고려한 해석 및 설계기술이 필요하다. 본 연구는 RF 커플러의 구조에 따른 출력 전기장의 세기와 온도 분포, 열 손실과 열 변형을 고려한 내구도 분석을 통해 성능 향상을 위한 방안들을 도출하는 것을 목적으로 하였다.

유한요소 연계해석을 이용한 불포화 토사사면 안전성 평가 (Coupled Finite Element Analysis of Partially Saturated Soil Slope Stability)

  • 김재홍;임재성;박성완
    • 한국지반공학회논문집
    • /
    • 제30권4호
    • /
    • pp.35-45
    • /
    • 2014
  • 사면의 안정성을 위한 한계평형해석은 간편함과 적용성 때문에 가장 널리 적용되고 있다. 이러한 간편한 방법으로 균질하지 않고 방향성 있는 지층 같은 다양한 지형조건을 해석하기에는 신뢰성과 설득력 있는 결과를 주기에 한계가 있다. 또한 지반굴착과 성토지반 같은 토사사면의 초기 응력상태나 응력경로와 같은 지반의 응력변화에 대해서 고려하지 못한다. 반면, 한계평형해석과는 다르게, 유한요소법에 의한 변형과 응력분포 해석은 시간에 따른 복잡한 하중단계와 탄성영역외의 범위를 다룰 수 있다. 본 연구에서는 불포화 토사사면에서 발생하는 얕은 파괴의 안전율 계산과 임계단면을 결정하는 방법을 제안한다. 유한요소해석은 유효응력 거동을 근간으로 각 요소들의 가우스 포인트에서 응력들이 계산되고 안전율이 가장 약한 지점들을 찾아 비선형 임계단면이 결정된다. 이러한 사면안정해석은 강우침투에 의해 변형되는 지반의 사면 표층파괴에 적합하게 계산된다. 침투에 의한 지반의 단위중량의 변화는 사면의 연직 및 수평변위에 영향을 주며, Drucker-Prager 파괴기준은 수리학-역학적인 연계된 불포화토의 거동 해석과 응력-변형률 관계를 위해 적용된다.

Verification of Microstructure Qualities of ACR-Approved Mammography Phantoms by Refraction-Enhanced Synchrotron Radiation Imaging

  • Imamura, Keiko;Ehara, Norishige;Inada, Yoichi;Miyamoto, Keiko;Kanemaki, Yoshihide;Umetani, Keiji;Uesugi, Kentaro;Ochiai, Yoshinori;Fukuda, Mamoru;Nakajima, Yasuo
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.415-417
    • /
    • 2002
  • Images of microcalcification specks showed large variation in conventional radiographs of phantoms which are approved for mammography image quality standard by the American College of Radiology (ACR). This kind of variation is not appropriate for image quality standards because the number of specks are visually counted in images and that number is important in image quality evaluation. Our study using synchrotron radiation (SR) imaging revealed the overlapping of micro-sized air bubble(s) to some specks, and also the structural deformation or crackings. Eight phantoms approved by ACR from two different makers and an air-bubble phantom were examined. SR imaging was performed at a synchrotron radiation facility, SPring-8, in Japan. The image-detector was a fluorescent-screen optical-lens coupling system using a CCD camera with a spatial resolution of 6 $\square$m. Objects when imaged with longer sample-to-detector distance show edge enhancement due to a difference in refraction indices, that is refraction enhancement. Refraction-enhanced SR images revealed that some of specks carried foreign objects, which were proven to be air. In phantoms provided by one maker, attaching/overlapping airs were observed for 62 out of 150 specks (41%) , with a higher incidence for the smallest specks. A speck becomes hardly visible in a conventional radiograph when air(s) overlaps the majority part of a speck, though depending on the size of the air-inclusion and on its configuration. Those airs might have been adsorbed on a speck surface before being embedded and then introduced into the matrix together with specks. Our study using SR imaging has clearly shown the nature of defects in some mammography phantoms which seriously degrade the quality as an image standard.

  • PDF

해상풍력터빈의 고유진동수 예측을 위한 지반에 인입된 파일의 연속체 지반 모델 기반 수평 거동 해석 (An analysis of horizontal deformation of a pile in soil using a continuum soil model for the prediction of the natural frequency of offshore wind turbines)

  • 유정수;백경민;이종화
    • 한국음향학회지
    • /
    • 제35권6호
    • /
    • pp.480-490
    • /
    • 2016
  • 풍력터빈의 대형화와 경량화에 따라 풍력터빈에 작용하는 동하중에 의한 진동 응답이 크게 발생할 수 있다. 특히 공진에서는 큰 진동 응답이 발생하므로 설계 시 정확한 고유진동수의 예측이 요구된다. 이를 위해 풍력터빈 지지구조와 지반에 대한 연성해석이 요구되는데, 일반적으로 유한요소에 기반한 수치적인 방법이 주로 이용된다. 그러나 유한요소 해석은 파일-지반 모델링 및 연산에 많은 노력과 시간을 요구하므로 초기 설계 단계에서는 활용에 많은 제약이 따른다. 반면, 지반을 선형화한 이론 해석은 모델이 단순하고 연산 시간이 매우 짧으므로, 해석의 신뢰성이 확보된다면 지반-지지구조의 거동 특성을 초기에 예측하는데 유용한 도구가 될 수 있다. 본 논문에서는 이론 해석을 이용해 지반에 인입된 파일에 대한 파일-지반 연성해석을 수행하였다. 해석 시 지반의 변형은 탄성 범위 이내에 있다고 단순화하여 파일은 보로, 지반은 연속체로 모델링하였다. 본 연속체 모델을 이용해 파일 상단에 수평 하중 또는 모멘트가 작용할 때 발생하는 파일의 횡변형을 구하고, 파일의 세장비에 따른 영향계수를 도출하였다. 그리고 이를 유한요소해석을 기반으로 한 문헌의 결과와 비교함으로써 해석 결과의 신뢰도를 평가하였다. 이를 통해 연속체 모델의 해석은 세장비가 큰 파일에 대해서는 유효한 반면 약 3 이하의 낮은 세장비를 가지는 파일에서는 신뢰성이 떨어짐을 확인하였다.

스위스 Mont Terri 지하연구시설 단층 내 유체 주입시험 모델링: 국제공동연구 DECOVALEX-2019 Task B(Step 2) (Numerical modelling of Fault Reactivation Experiment at Mont Terri Underground Research Laboratory in Switzerland: DECOVALEX-2019 TASK B (Step 2))

  • 박정욱;;;;박의섭
    • 터널과지하공간
    • /
    • 제29권3호
    • /
    • pp.197-213
    • /
    • 2019
  • 본 연구에서는 TOUGH-FLAC 연동해석기법을 이용하여 Mont Terri 지하연구시설에서 수행된 단층 내 물 주입시험을 수치적으로 모델링하고, 단층의 재활성과 수리역학적 거동 특성을 살펴보았다. TOUGH2 해석에서는 단층을 Darcy의 법칙과 삼승법칙(Cubic law)을 따르는 연속체 요소로 모델링하였으며, FLAC3D 해석에서는 미끄러짐과 개폐가 허용되는 불연속 인터페이스 요소를 통해 모사하였다. 현장에서 획득한 단층의 균열개방압력(fracture opening pressure), 주입율, 모니터링 압력, 변위 곡선 등을 바탕으로, 단층의 탄성적 변형과 파괴에 의한 수직팽창 특성을 반영할 수 있는 수리간극모델과 수리역학 커플링 관계를 해석모델에 반영하였다. 한편, 현지응력 조건, 단층의 강도 및 변형 특성에 따른 파라미터 해석을 실시하여 각 입력변수가 해석 결과에 미치는 영향을 분석하였으며, 이를 통해 현장시험 결과를 가장 잘 재현할 수 있는 파라미터 조합을 선정하였다. 해석 결과, 균열개방압력에서 단층의 주입율과 모니터링 압력이 크게 증가하는 현상을 합리적으로 재현할 수 있었다. 하지만, 동일한 입력 변수 조건에서 단층의 전단변위와 파괴영역의 범위는 현장시험 결과에 비해 과대평가되는 결과를 보였다. 이는 해석모델에서는 고압의 주입조건에서 단층의 지속적인 전단파괴가 유도되는 반면, 현장에서는 수리간극의 변화가 전단 미끄러짐보다는 인장력에 의한 단층면의 개방(tensile opening)에 크게 의존하는 것으로 추정되기 때문이다.

토압식 쉴드 TBM 굴착에 따른 지반침하 거동 평가에 관한 해석적 기초연구 (A preliminary study for numerical and analytical evaluation of surface settlement due to EPB shield TBM excavation)

  • 안준범;강석준;김정주;김경열;조계춘
    • 한국터널지하공간학회 논문집
    • /
    • 제23권3호
    • /
    • pp.183-198
    • /
    • 2021
  • 토압식 쉴드 TBM 공법은 커터헤드 후면 챔버에 버력을 채워 막장 안정성을 확보하는 공법으로, 연속적인 굴착 및 지보를 통해 지반 변형을 억제하는 것으로 알려져 있다. 하지만 여전히 지반 조건, 터널 크기, 그리고 시공 조건에 의해 무시할 수 없는 지반 침하가 발생하는 실정이다. 따라서 지반침하 영향인자에 의한 침하 거동을 명확하게 이해하고 이를 기반으로 시공 중 발생 가능한 지반침하를 평가할 필요가 있다. 본 연구에서는 토압식 쉴드 TBM 시공 시의 지반침하 주요 영향 인자들과 침하 발생 메커니즘이 반영된 해석 모델(analytical model)을 제시하였고, 시공 중 조절 가능한 인자들에 대한 매개변수 해석을 수치해석 기법을 통해 수행하였다. 수치해석 결과를 통해 시공 조건에 의한 침하 거동을 정량적으로 도출하였으며, 침하 해석 모델과의 연계를 통해 지반 조건에 따른 정성적인 경향성을 도시하였다. 본 연구 결과를 통해 토압식 쉴드 TBM 굴착에 의한 침하예측모델 도출에 기여할 것으로 기대된다.

Experimental and analytical study of squat walls with alternative detailing

  • Leonardo M. Massone;Cristhofer N. Letelier;Cristobal F. Soto;Felipe A. Yanez;Fabian R. Rojas
    • Computers and Concrete
    • /
    • 제33권5호
    • /
    • pp.497-507
    • /
    • 2024
  • In squat reinforced concrete walls, the displacement capacity for lateral deformation is low and the ability to resist the axial load can quickly be lost, generating collapse. This work consists of testing two squat reinforced concrete walls. One of the specimens is built with conventional detailing of reinforced concrete walls, while the second specimen is built applying an alternative design, including stirrups along the diagonal of the wall to improve its ductility. This solution differs from the detailing of beams or coupling elements that suggest building elements equivalent to columns located diagonally in the element. The dimensions of both specimens correspond to a wall with a low aspect ratio (1:1), where the height and length of the specimen are 1.4 m, with a thickness of 120 mm. The alternative wall included stirrups placed diagonally covering approximately 25% of the diagonal strut of the wall with alternative detailing. The walls were tested under a constant axial load of 0.1f'cAg and a cyclic lateral displacement was applied in the upper part of the wall. The results indicate that the lateral strength is almost identical between both specimens. On the other hand, the lateral displacement capacity increased by 25% with the alternative detailing, but it was also able to maintain the 3 complete hysteretic cycles up to a drift of 2.5%, reaching longitudinal reinforcement fracture, while the base specimen only reached the first cycle of 2% with rapid degradation due to failure of the diagonal compression strut. The alternative design also allows 46% more energy dissipation than the conventional design. A model was used to capture the global response, correctly representing the observed behavior. A parametric study with the model, varying the reinforcement amount and aspect ratio, was performed, indicating that the effectiveness of the alternative detailing can double de drift capacity for the case with a low aspect ratio (1.1) and a large longitudinal steel amount (1% in the web, 5% in the boundary), which decreases with lower amounts of longitudinal reinforcement and with the increment of aspect ratio, indicating that the alternative detailing approach is reasonable for walls with an aspect ratio up to 2, especially if the amount of longitudinal reinforcement is high.