• 제목/요약/키워드: Defects diagnosis

검색결과 360건 처리시간 0.03초

유연매체 이송 시스템의 고장 진단을 위한 Simulation (Simulation for Automatic Diagnosis of Defect in Media Transport System)

  • 이남훈;유상헌;구자춘;최연선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.564-568
    • /
    • 2005
  • As functional requirements of automatic office machines like printers, ATMs, copying machines are on a trend for the higher speed and precision, extensive technical advances are being developed and implemented in the industry. Media transport system is a device to convey a sheet of paper in ATMs and printers. The stability of media transport system is a matter of concern as their operating throughput rapidly increases. And defects of belts or rollers in a transport system directly affect the level of stability of the system. Therefore an automatic diagnostic system for predicting various defects is necessary for the stable operation of the media transport system. A simulation based on multi-body dynamics has been done for a feasibility study of a system design for the defect anticipation.

  • PDF

Renal replacement therapy in neonates with an inborn error of metabolism

  • Cho, Heeyeon
    • Clinical and Experimental Pediatrics
    • /
    • 제62권2호
    • /
    • pp.43-47
    • /
    • 2019
  • Hyperammonemia can be caused by several genetic inborn errors of metabolism including urea cycle defects, organic acidemias, fatty acid oxidation defects, and certain disorders of amino acid metabolism. High levels of ammonia are extremely neurotoxic, leading to astrocyte swelling, brain edema, coma, severe disability, and even death. Thus, emergency treatment for hyperammonemia must be initiated before a precise diagnosis is established. In neonates with hyperammonemia caused by an inborn error of metabolism, a few studies have suggested that peritoneal dialysis, intermittent hemodialysis, and continuous renal replacement therapy (RRT) are effective modalities for decreasing the plasma level of ammonia. In this review, we discuss the current literature related to the use of RRT for treating neonates with hyperammonemia caused by an inborn error of metabolism, including optimal prescriptions, prognosis, and outcomes. We also review the literature on new technologies and instrumentation for RRT in neonates.

상악동의 실험병소에 관한 X선학적 연구 (A RADIOGRAPHIC STUDY OF THE EXPERIMENTAL LESIONS IN THE MAXILLARY SINUS)

  • 이주현;황의환;이상래
    • 치과방사선
    • /
    • 제24권1호
    • /
    • pp.115-124
    • /
    • 1994
  • The purpose of this study was to examine the differences in representation of a globular radiopaque mass on the pantomograms and Waters' views and to compare the efficacy of periapical radiograms, pantomograms and Waters' views in detection of defects on the internal walls of the maxillary sinus. This study was performed with dried human skull. For the study of difference of radiopaque mass shadow in the two views, rubber ball with a diameter of 10㎜ was used as the experimental lesion. It was placed successively on the internal wall of the anterior, posterior, medial, lateral walls and floor of the maxillary sinus. To examine the detectability of defects for radiographic techniques, defects were formed in the anterior, posterior, medial, lateral walls, and floor of the maxillary sinus. They were formed with 0.5㎜, 0.75㎜, 1.0㎜, 2.0㎜ and 3.0㎜ sized steel round burs with a slow speed dental handpiece. By subsequently plugging the holes with zinc oxide eugenol paste, radiopaque defects were produced. After that the periapical radiograms, the pantomograms and the Waters' views were taken each and every defect. The obtained results were as follows: 1. Rubber balls placed on each internal wall of the maxillary sinus were correctly depicted on the posterior wall and the floor in case of the pantomogram, and on the anterior wall and the medial wall in case of the Waters' view. 2. On the detectability of defects for each radiographic technique, radiolucent defects were detected in different places for each technique. Periapical radiogram could detect 1.0㎜ defect on the floor of the maxillary sinus, pantomogram could detect 2.0㎜ defect on every internal wall of the maxillary sinus, and Waters' view could detect 3.0㎜ defect on the anterior wall of the maxillary sinus. 3. On the detectability of defects for each radiographic technique, radiopaque defects were detected in different places for each technique. Periapical radiogram could clearly detect 0.5㎜ defect on the floor of the maxillary sinus, pantomogram could detect 0.5㎜ defect on every internal wall of the maxillary sinus, and finally Waters' view could detect 0.5㎜defect on the anterior wall of the maxillary sinus but 0.75㎜ defect on the anterior wall, lateral wall and floor of the maxillary sinus. As the result, the periapical radiogram is the most simple and satisfactory method for investigating in the maxillary sinus. The pantomogram is suitable method for screening of changes in the maxillary sinus. And the Waters' view is available for detect of lesion in the anterior wall of the maxillary sinus. For the purpose of accurate diagnosis and evaluation of lesion in the maxillary sinus, these techniques supplement each other.

  • PDF

시나리오 기반 상·하수도 관로의 실시간 결함검출 기술 개발 (Development of real-time defect detection technology for water distribution and sewerage networks)

  • 박동채;최영환
    • 한국수자원학회논문집
    • /
    • 제55권spc1호
    • /
    • pp.1177-1185
    • /
    • 2022
  • 상·하수도 시스템은 사람들에게 안전하고 깨끗한 물을 공급해주는 사회기반시설이며, 특히 상·하수도 관로는 지중에 매설되어 있기 때문에 시스템의 결함검출이 매우 어렵다. 이러한 이유로 상·하수도 관로의 진단은 관로 내부에 카메라 및 드론을 통한 촬영을 하여 사후에 촬영된 영상을 바탕으로 시스템 진단하는 등의 사후 결함검출로 제한되기 때문에, 작업자의 업무 효율 증대와 진단의 신속성을 위해서는 관로의 실시간 탐지기술이 필요하다. 최근 첨단장비 및 인공지능 기법을 활용한 시설물 진단 기술이 개발되고 있지만, 인공지능기반 결함검출 기술은 결함 데이터의 종류 및 형태, 수가 검출 성능에 영향을 주기 때문에 다양한 학습데이터가 필요하다. 따라서, 본 연구에서는 상·하수도 관로의 결함검출 시 탐지 성능 향상을 위해 다양한 결함 시나리오를 3D 프린트를 이용하여 구현하고 이를 수집된 결함 데이터와 함께 학습데이터로 사용한다. 이후 수집된 이미지는 위험도에 따른 분류 및 객체의 라벨링 등의 전처리 작업이 수행되고 실시간 결함탐지를 수행한다. 제안된 기법은 상·하수도시스템 결함검출 시 실시간 피드백을 제공함으로써, 작업자의 진단 누락 가능성을 최소화하며 기존의 상·하수도관 진단업무 처리능력을 향상할 수 있다.

Prenatal Diagnosis of Chromosome 22q11.2 Deletions: Experiences in a Single Institution

  • Chae, Yong Hwa;Kwak, Dong Wook;Kim, Moon Young;Park, So Yeon;Lee, Bom Yi;Lee, Yeon Woo;Lee, Young Ho;Song, Mi Jin;Ryu, Hyun Mee
    • Journal of Genetic Medicine
    • /
    • 제10권2호
    • /
    • pp.99-103
    • /
    • 2013
  • Purpose: This study was designed to determine the frequency and echocardiographic findings of 22q11.2 deletions in fetuses with cardiac defects on fetal ultrasound or familial backgrounds of 22q11.2 deletions. Materials and methods: We retrospectively reviewed the medical and ultrasonographic records of 170 fetuses that underwent fluorescence in situ hybridization (FISH) analysis for chromosome 22q11.2 deletions between February 2001 and April 2013. Results: Among 145 fetuses with cardiac defects, six (4.1%) had 22q11.2 deletions. Deletions of 22q11.2 were detected in 6 (5%) of the 120 fetuses with conotruncal defects: 5 (8.9%) of 56 with tetralogy of Fallot (TOF) and 1 (5.9%) of 17 with double outlet right ventricle (DORV). No deletions were found in cases of pulmonary atresia, truncus arteriosus, right aortic arch, or transposition of the great arteries. No 22q11.2 deletions were found in non-conotruncal cardiac malformations. Among 25 fetuses with familial backgrounds of 22q11.2 deletions, one (4%) had a maternally inherited 22q11.2 deletion with no cardiac findings. Conclusion: Knowledge of the frequency and echocardiographic findings of 22q11.2 deletions might be helpful for prenatal genetic counseling. It is advisable to perform FISH analysis for 22q11.2 deletions in pregnancies exhibiting conotruncal cardiac defects such as TOF or DORV.

디지털방사선사진과 구내방사선사진의 인접면 인공우식진단능에 관한 비교연구 (COMPARATIVE STUDY OF DIGITAL AND CONVENTIONAL RADIOGRAPHY FOR THE DIAGNOSTIC ABILITY OF ARTIFICIAL PROXIMAL SURFACE CARIES)

  • 조영곤;박시승
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.113-121
    • /
    • 2002
  • Conventional intraoral radiography continues to be the most widely used image modality for the diagnosis of dental caries. But, conventional intraoral radiography has several shortcomings, including the difficulty of exposing and processing intraoral film of consistently acceptable quality. In addition, radiographic retaking that was the result of processing errors, may result in increased discomfort and radiation dose to the patient. Recently, various digital radiographies substitute for conventional intraoral radiography to overcome these disadvantages. The advantages of digital radiography are numerous. One of advantages Is the elimination of processing errors. In addition, the radiation dose for digital system is approximately 20% to 25% of that required for conventional intraoral radiography Another potential advantage of digital imaging is the ability to perform image quality enhancements such as contrast and density modulation, which may increase diagnostic accuracy. The purpose of this study was to compare the diagnostic ability of artificial proximal defects to conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital image(Digora$^{\circledR}$). Artificial defects were made in proximal surfaces of 60 extracted human molars using #1/2, #1, #2 round bur. Five dentists assessed proximal defects on conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital image(Digora$^{\circledR}$). ROC(Receiver Operating Characteristic) analysis and Two-way ANOVA test were used for the evaluation of detectability, and following results were acquired. 1. The mean ROC area of conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital Image(Digora$^{\circledR}$) were 0.6766, 0.7538, 0.6791(Grade I), 0.7176, 0.7594, 0.7361(Grade II), and 0.7449, 0.7608, 0.7414(Grade III), respectively. 2. Diagnostic ability of direct digital image was higher than other image modalities. But, there was no statistically significant difference among other imaging modalities for Grade I, II, III lesion(p>0.05). In conclusion, when direct and indirect digital system are comparable with conventional intraoral radiography. these systems may be considered an alternative of conventional intraoral radiography for the diagnosis of proximal surface caries.

거대혈소판 증후군 (Giant platelet syndrome)

  • 국훈
    • Clinical and Experimental Pediatrics
    • /
    • 제49권8호
    • /
    • pp.833-838
    • /
    • 2006
  • Giant platelet syndrome is a group of unique disorders characterized by the presence of abnormally large platelets, and usually accompanied by thrombocytopenia. Most cases of giant platelets are encountered in idiopathic thrombocytopenic purpura(ITP). In contrast, inherited giant platelet disorders, a group of heterogeneous diseases, are rare. Bernard-Soulier syndrome and its variants, and MYH9 related diseases have been defined at the molecular level. Abnormalities in transcription factors are implicated in a couple of macrothrombocytopenia syndromes. However, the molecular defects are unknown in gray platelet syndrome. It is important to make a proper diagnosis of congenital macrothrombocytopenia to avoid unnecessary medications and potentially dangerous treatment for presumed ITP.

Comparison of ECT Probes in Diagnosis of Defects

  • Mun, Ho-Young;Kim, Chang-Eob
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.190-196
    • /
    • 2014
  • In this paper, the characteristics of a defective elliptical aluminum plate are analyzed by three different eddy current testing probes; T/R, T/T, and Impedance probes. The analysis was done by 3D finite element method, and the impedance change of real and imaginary voltage values were analyzed.

도시철도차량 구조체의 정밀진단에 관한 고찰 (On study the diagnosis of carbody structure for EMU)

  • 정종덕;윤성철;홍선호;전한준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.706-711
    • /
    • 2003
  • This paper describes EDM testing, Magnetic particle testing and Ultrasonic testing results of carbody structure for EMU. Carbodys are subject to vibration, impact and wear which can cause severe defects leading to a fatal accident. The purpose of the test is to prove the endurance of Korean EMU for the commercial operation.

  • PDF

유비쿼터스 기술을 이용한 무선센서노드 개발 및 장대교량 현장적용 검증 실험 (Development of Wireless Sensor Node and Field Application of Long-span Bridge using Ubiquitous Technology)

  • 조병완;박정훈;신병철;김헌;윤광원;양요섭
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.127-132
    • /
    • 2008
  • As economic rapid growth, large structures are damaged by defects from design and construction process of the formation and environments. Therefore, safety diagnosis and monitoring skills are bringing importance into relief and legislate for safety diagnosis of large structures. However, the existing monitoring systems are difficult by using wire cable because of cost, error of date, location, revise. In this paper, wireless sensor network which are accelerator, temperature sensor system using ubiquitous had been field test on Sea-Hea Grand bridge. We compare accelerator, temperature sensor system with wire and wireless sensor network.

  • PDF