• 제목/요약/키워드: Defects

검색결과 8,536건 처리시간 0.036초

Amorphization of Silicon by 250 keV Electron Irradiation and Hydrogen Annealing

  • Jo Jung-Yol
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권1호
    • /
    • pp.23-27
    • /
    • 2005
  • We observed that optical properties of silicon changed under high dose electron irradiation at 250 keV. Our experimental results revealed that the optical transmission through a silicon wafer is significantly increased by electron irradiation. Transmission increase by the change in the absorption coefficient is explained through an analogy with amorphous silicon. Moreover, solar cell open-circuit voltages indicated that defects were generated by electron irradiation, and that the defects responded to annealing. Our results demonstrated that the optical properties of silicon can be controlled by a combination of electron irradiation and hydrogen annealing.

다단계 자동차 부품 소성가공 공정설계 (Process Design in Multi-stage Forming of an Automobile Component)

  • 변상규;양순종;제진수;강범수
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1996년도 춘계학술대회논문집
    • /
    • pp.121-129
    • /
    • 1996
  • This study aimsdetecting defects for the forming precesses of X2 spline, which is designed by an industry expert. The exist process consists of 3 runs and 7 operations with 3 heat treatments. The rigid-plastic FEM analysis was carried out to design a new process and some defects were found. Thus the design was modified to get better results. it is ocnfirmed that the industry expert agree the possibility of defects derived from the FEM results.

  • PDF

Guided bone regeneration

  • Kim, Young-Kyun;Ku, Jeong-Kui
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제46권5호
    • /
    • pp.361-366
    • /
    • 2020
  • Guided bone regeneration (GBR) is a surgical procedure that utilizes bone grafts with barrier membranes to reconstruct small defects around dental implants. This procedure is commonly deployed on dehiscence or fenestration defects ≥2 mm, and mixing with autogenous bone is recommended on larger defects. Tension-free primary closure is a critical factor to prevent wound dehiscence, which is critical cause of GBR failure. A barrier membrane should be rigidly fixed without mobility. If the barrier is exposed, closed monitoring should be utilized to prevent secondary infection.

Theoretical Investigation of Edge-modified Zigzag Graphene Nanoribbons by Scandium Metal with Pyridine-like Defects: A Potential Hydrogen Storage Material

  • Mananghaya, Michael
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권1호
    • /
    • pp.253-256
    • /
    • 2014
  • Functionalization of zigzag graphene nanoribbon (ZGNR) segment containing 120 C atoms with pyridine (3NV-ZGNR) defects was investigated on the basis of density-functional theory (DFT) calculations, results show that edge-modified ZGNRs by Sc can adsorb multiple hydrogen molecules in a quasi-molecular fashion, thereby can be a potential candidate for hydrogen storage. The stability of Sc functionalization is dictated by a strong binding energy, suggesting a reduction of clustering of metal atoms over the metal-decorated ZGNR.

Elastic and Electronic Properties of Point Defects in Titanium Carbide

  • Kang, Dae-Bok
    • 대한화학회지
    • /
    • 제57권6호
    • /
    • pp.677-683
    • /
    • 2013
  • A theoretical study of the electronic structures of $TiC_{1-x}$ and $Ti_{1-x}W_xC$ (x = 0, 0.25) is presented. The density of states and crystal orbital overlap population calculations were used to interpret variations of elastic properties induced by carbon vacancies and alloying substitutions. Our results show why the introduction of vacancies into TiC reduces bulk moduli, while W substitution at a Ti site increases the elastic modulus. The effect of the point defects on the bonding in TiC is investigated by means of extended Huckel tight-binding band calculations.

Judet's Strut와 Teflon Mesh를 이용한 다발성 늑골골절 및 흉벽결손의 치험 1례 (One Case Tratment of Multiple Ribs Fracture with Chest Wall Defects (by Use of Judet's Struts and Teflon Mesh))

  • 신윤곤
    • Journal of Chest Surgery
    • /
    • 제27권5호
    • /
    • pp.422-426
    • /
    • 1994
  • Recently, we experienced one case of multiple ribs fracture with large chest wall defects. This patient was treated with internal fixation of ribs by use of Judet`s struts and reconstruction of chest wall defects by use of Teflon mesh. Postoperative outcome was satisfactory result and its advantages were reduced duration of operation, prevention of pulmonary herniation and reduced risk of postoperative infection.

  • PDF

FEW RESULTS ON RELATIVE (k, n) VALIRON DEFECTS FROM THE VIEW POINTS OF INTEGRATED MODULI OF LOGARITHMIC DERIVATIVE OF ENTIRE AND MEROMORPHIC FUNCTIONS

  • Datta, Sanjib Kumar;Sarkar, Sukalyan;Bandyopadhyay, Ashima;Biswas, Lakshmi
    • Korean Journal of Mathematics
    • /
    • 제29권2호
    • /
    • pp.239-252
    • /
    • 2021
  • The prime target of this paper is to compare some relative (k, n) Nevanlinna defects with relative (k, n) Valiron defects from the view point of integrated moduli of logarithmic derivative of entire and meromorphic functions where k and n are any two non-negative integers.

디지털방사선촬영법을 이용한 치조골벽 소실에 관한 실험적 연구 (EXPERIMENTAL STUDY OF ALVEOLAR BONE WALL DEFECTS USING DIRECT DIGITAL RADIOGRAPHY)

  • 송남규;고광준
    • 치과방사선
    • /
    • 제27권2호
    • /
    • pp.49-61
    • /
    • 1997
  • The purpose of this study was to compare E-speed film, CDR, and modified CDR images by means of observing some artificial defects of alveolar bone wall in the sound human dried mandibles. High diagnostic accuracy was shown in 1 wall and 4 wall defects by all 5 observers (2 Radiologists, 2 Periodontists, 1 General practitioner), but the diagnosis in 2 wall and 3 wall defects was inaccurate. Modified CDR images had the more diagnostic accuracy than E-speed film and CDR images, but there was no statistical difference among them. Finally, radiologist used modified CDR images more than others and used equalization effect more than the change in contrast and/or brightness.

  • PDF

적외선열화상을 이용한 복합소재대차의 결함평가 (Thermographic Defects Evaluation of Railway Composite Bogie)

  • 김정국;권성태;김정석;윤혁진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.548-553
    • /
    • 2011
  • The lock-in thermography was employed to evaluate the defects in railway bogies. Prior to the actual application on railway bogies, in order to assess the detectability of known flaws, the calibration reference panel was prepared with various dimensions of artificial flaws. The panel was composed of polymer matrix composites, which were the same material with actual bogies. Through lock-in thermography evaluation, the optimal frequency of heat source was determined for the best flaw detection. Based on the defects information, the actual defect assessments on railway bogie were conducted with different types of railway bogies, which were used for the current operation. In summary, it was found that the novel infrared thermography technique could be an effective way for the inspection and the detection of surface defects on bogies since the infrared thermography method provided rapid and non-contact investigation of railway bogies.

  • PDF

Management of the Sequelae of Severe Congenital Abdominal Wall Defects

  • Fuentes, Sara;Marti, Eunate;Delgado, Maria-Dolores;Gomez, Andres
    • Archives of Plastic Surgery
    • /
    • 제43권3호
    • /
    • pp.258-264
    • /
    • 2016
  • Background The survival rate of newborns with severe congenital abdominal wall defects has increased. After successfully addressing life-threatening complications, it is necessary to focus on the cosmetic and functional outcomes of the abdominal wall. Methods We performed a chart review of five cases treated in our institution. Results Five patients, ranging from seven to 18 years of age, underwent the following surgical approaches: simple approximation of the rectus abdominis fascia, the rectus abdominis sheath turnover flap, the placement of submuscular tissue expanders, mesh repair, or a combination of these techniques depending on the characteristics of each individual case. Conclusions Patients with severe congenital abdominal wall defects require individualized surgical treatment to address both the aesthetic and functional issues related to the sequelae of their defects.