• Title/Summary/Keyword: Defect depth

검색결과 329건 처리시간 0.027초

콤바인 예취부의 고장요인이 예취날의 평균 속도, 반송 두께, 탈곡통의 회전 속도에 미치는 영향 (Effects of Defect Factors of Combine Header on Cutting Speed of Combine Header, Feeding Depth of Straw, and Cylinder Speed of Thresher)

  • 김용주;최창현;문정환
    • Journal of Biosystems Engineering
    • /
    • 제32권5호
    • /
    • pp.324-331
    • /
    • 2007
  • The purpose of this study is to analysis effects of defect factors of combine header for cutting speed of combine header, feeding depth of straw, and cylinder speed of thresher. Measurement system for defect factors was consists of sensors to monitor the combine operation and I/O interface to convert the signals. Cutting speed of combine header, feeding depth of straw, cylinder speed of thresher were measured and analyzed. The data were collected from three paddy field during rice harvesting. The tests were conducted at different grounding speeds, lug troubles, and cutter condition. The one way ANOVA and the multiple comparison tests were performed. The results showed that the measured data were useful to monitor the defect factors of combine during harvesting. The faults conditions of grounding speeds, lug troubles, and cutter conditions affected cutting speeds, feeding depths and cylinder speeds of the combine. The data seem to be useful to analysis the faults conditions of combine header.

큐렛팁을 장착한 압전방식 초음파치석제거기의 작업조건에 따른 치과주조용 합금의 삭제에 관한 연구 (The Effect of a Piezoelectric Ultrasonic Scaler with Curette Tip on Casting Gold Removal in Vitro)

  • 이영규
    • Journal of Periodontal and Implant Science
    • /
    • 제31권3호
    • /
    • pp.531-542
    • /
    • 2001
  • Periodontal debridement is most important procedure in periodontal treatment, because periodontal disease is the biofilm infection. The use of ultrasonic instrument has many clinical advantages compared to classical hand instrument. The introduction of newly developed ultrasonic scaler tips made the use of ultrasonic scaler popular. However the study of tooth substance removal according to the working parameters of ultrasonic scaler with newly developed tips is not sufficient. The purpose of this study is to evaluate the effects of working parameters of piezoelectric ultrasonic scaler with curette tip on casting gold removal. The working parameters was standardized by the sledge device which controls lateral force(0.5 N, 1.0 N, 2.0 N) and power setting was adjusted 2, 4, 8 in P mode and S mode and instrumentation time was 5 seconds. The defect depth and width were measured with profile meter and defect surface was examined by SME. The depth of defect was significantly large in S mode( $39.58{\pm}19.35{\mu}m$) compared to P mode( $8.37{\pm}6.98{\mu}m$). There was significant decrease of depth of defect between 1.0N($32.87{\pm}27.18{\mu}m$) and 2.0N( $14.86{\pm}15.04{\mu}m$). The area of defect was also significantly large in S mode($4482.42{\pm}3551.71{\mu}m^2$) compared to P mode( $922.06{\pm}960.32{\mu}m^2$). There was significant decrease of area of defect between 1.0N($3889.12{\pm}3936.00{\mu}m$) and 2.0N( $974.66{\pm}986.01{\mu}m$). The change of mode did not effect on the width of the defect. The change of power setting did not effect on the depth, width, and area of defect. In spite of limitation of this study it could be concluded that the use of piezoelectric ultrasonic scaler with curette tip on S mode could make significant tooth substance loss.

  • PDF

실리콘에 MaV로 이온주입된 인의 결함분포와 profile에 관한 연구 (A Study of defect distribution and profiles of MeV implanted phosphorus in silicon)

  • 정원채
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권9호
    • /
    • pp.881-888
    • /
    • 1997
  • This study demonstrats the profiles of phosphorus ions in silicon by MeV implantation(1∼3 MeV). Implanted profiles could be measured by SIMS(Cameca 4f) and compared with simulation results(TRIM program and analytical description method only using on Pearson function). The experimental result in the peak concentration region has a little bit deviation from simulation data. By RBS and Channeling measurements the defect distribution of implanted samples could be measured and spectrum are calibrated depth with RUMP simulation By XTEM measurement the thickness of defect zone also could be measured. Finally thermal annealing for the electrical activation of implanted ions carried out by RTA(rapid thermal annealing). The concentration-depth profiles after heat treatment was measured by SR(spreading resistance)-method.

  • PDF

큐렛형 팁을 장착한 압전방식 초음파 치석제거기가 치근대체물 삭제에 미치는 영향 (The Effect of a Piezoelectric Ultrasonic Scaler with Curette Tip on Root Substitute Removal in Vitro)

  • 이영규
    • Journal of Periodontal and Implant Science
    • /
    • 제30권2호
    • /
    • pp.429-442
    • /
    • 2000
  • Based on current evidence in the literature, it is known that endotoxin is a weakly adherent surface phenomenon and that power-driven instruments can be used to accomplish definitive root detoxification and maximal wound healing without overinstrumentation of root and without extensive cementum removal. And one of the newly developed curette tips used with low power of piezoelectric ultrasonic scaler, is effective to remove calculus and not to remove the excessive cementum. The purpose of this study is therefore, to assess the influence of ultrasonic power and various working parameters on root substitute removal when instrumentation is performed with the curette tip on piezoelectric ultrasonic scaler. This study assessed defect depth, width and area resulting from instrumentation using a piezoelectric ultrasonic scaler with a curette type tip in vitro to acrylic resin block as a root substitute. The working parameters was standardized by the sledge device which controls lateral force(0.5 N, 1 N, 2 N) and instrumentation time(5 sec, 10 sec, 20 sec) and power setting was adjusted 0,2,4,8 in P mode. Power setting had the greatest influence on defect depth compared to lateral force and instrumentation time(standardized regression parameter estimates${\pm}$standard error, $0.37{\pm}0.02$, $0.19{\pm}0.02$, $0.07{\pm}0.02$). The effects on defect area also greatest for power setting($0.57{\pm}0.03$) compared to lateral force and instrumentation time($0.33{\pm}0.03$, $0.12{\pm}0.03$). The effect of the power setting on the defect width($0.15{\pm}0.01$) is not so great as defect depth or defect area compared to lateral force($0.12{\pm}0.01$) and effect of instrumentation time is minimal($0.02{\pm}0.01$). It could be concluded that the power setting has the greatest influence on the defect depth and area in curette type tip with low power of piezoelectric ultrasonic device. Many parameters can be adjusted in various situation in clinical use of piezoelectric ultrasonic scaler but the power setting is the first parameter to be adjusted.

  • PDF

열화상 비파괴 검사법을 이용한 도로포장 결함 검출 (Detecting of the defects of pavement of a road by using infrared thermography)

  • 심준기;김기현
    • 복합신소재구조학회 논문집
    • /
    • 제6권3호
    • /
    • pp.69-76
    • /
    • 2015
  • The purpose of this paper is to find an limitation to detect the defect of damaged asphalt pavement structures for infrared thermography. We use heat source of a natural light to detect the defect efficiently. The heat source was applied to the asphalt specimens. Four asphalt specimens were used: one was the asphalt containing depth of 1cm internal timber, two was the asphalt containing depth of 2cm internal void, Three was the asphalt containing depth of 3cm internal timber and four was not the asphalt containing internal timber. It was found that the depth of 3cm internal timber could be detected by this method. In addition, we used the image processing to make the damage zone displayed clear in the image obtained from the thermographic operation.

증기발생기 세관 검사를 위한 RPC 프로브의 신호 해석 (Analysis of RPC Probe Signal for Examination of Steam Generator Tube)

  • 송호준;서희정;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.887-889
    • /
    • 2004
  • This paper presents an analysis of RPC probe signal in steam generator tube with defect using finite element method. Impedance signal is calculated according to the depth variation of defect in tube and change of frequency in same defect. As the depth of the defect and the operating frequency is increased, the magnitude of the signal is increased. From the result of this paper, we can obtain the information by the effect of defect and frequency.

  • PDF

자동 표면 결함검사 시스템에서 Retro 광학계를 이용한 3D 깊이정보 측정방법 (Linear System Depth Detection using Retro Reflector for Automatic Vision Inspection System)

  • 주영복
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.77-80
    • /
    • 2022
  • Automatic Vision Inspection (AVI) systems automatically detect defect features and measure their sizes via camera vision. It has been populated because of the accuracy and consistency in terms of QC (Quality Control) of inspection processes. Also, it is important to predict the performance of an AVI to meet customer's specification in advance. AVI are usually suffered from false negative and positives. It can be overcome by providing extra information such as 3D depth information. Stereo vision processing has been popular for depth extraction of the 3D images from 2D images. However, stereo vision methods usually take long time to process. In this paper, retro optical system using reflectors is proposed and experimented to overcome the problem. The optical system extracts the depth without special SW processes. The vision sensor and optical components such as illumination and depth detecting module are integrated as a unit. The depth information can be extracted on real-time basis and utilized and can improve the performance of an AVI system.

CFRP 튜브의 결함형상.결함깊이.레이디얼 하중에 따른 와전류 신호의 변화 (Variation of Eddy Current Signal According to the Defect Shape, Defect Depth and Radial Load in CFRP Tube)

  • 송삼홍;안형근;이정순;오동준;송일;김철웅
    • 대한기계학회논문집A
    • /
    • 제28권12호
    • /
    • pp.2004-2011
    • /
    • 2004
  • The applicability of the ultrasonic C-scan inspection is restricted due to the deterioration of mechanical properties of specimen during the test. Therefore, the aim of this research is applied to Eddy Current (EC) test substitute for the C-scan inspection in CFRP tube containing defects. This research is to evaluate the EC signals for the inspection of CFRP tube containing various circular hole defects (20% to 100% depth to the specimen thickness) using the unloading specimen and radial loading specimen. This study was considered the following points; 1) Analysis of EC signals for the inspection of saw-cut defect and circular hole defect, 2) The evaluation of defect depths and EC signals relationship. 3) Variation of EC signal owing to the radial load. In conclusions, the high frequency such as 300∼500 kHz made it possible to the inspection of 40% to 100% defects. Particularly, in case of 20% defect, the EC signal was not detected due to the noise of micro-crack and delamination. While the depth of the hole defects were decreasing, the difference of the phase angle between unloading specimen and radial loading specimen was gradually increasing.

Prediction of the Effect of Defect Parameters on the Thermal Contrast Evolution during Flash Thermography by Finite Element Method

  • Yuan, Maodan;Wu, Hu;Tang, Ziqiao;Kim, Hak-Joon;Song, Sung-Jin;Zhang, Jianhai
    • 비파괴검사학회지
    • /
    • 제34권1호
    • /
    • pp.10-17
    • /
    • 2014
  • A 3D model based on the finite element method (FEM) was built to simulate the infrared thermography (IRT) inspection process. Thermal contrast is an important parameter in IRT and was proven to be a function of defect parameters. Parametric studies were conducted on internal defects with different depths, thicknesses, and orientations. Thermal contrast evolution profiles with respect to the time of the defect and host material were obtained through numerical simulation. The thermal contrast decreased with defect depth and slightly increased with defect thickness. Different orientations of thin defects were detected with IRT, but doing so for thick defects was difficult. These thermal contrast variations with the defect depth, thickness, and orientation can help in optimizing the experimental process and interpretation of data from IRT.

치주판막술에 의해 치료된 골연하 결손부의 장기적 방사선학적 변화 양사의 관찰 (Long-term radiographic evaluation of infrabony defect treated by flap operation)

  • 배상렬;박진우;서조영;이재목
    • Journal of Periodontal and Implant Science
    • /
    • 제38권3호
    • /
    • pp.429-436
    • /
    • 2008
  • Purpose: The goal of periodontal regenerative therapy is to replace bone, cementum, and periodontal ligament on a previously diseased root surface, which has suffered the loss of these supporting structures. To accomplish the regeneration, a number of surgical procedures have been advocated throughout the years. There seems to be a potential for some spontaneous periodontal tissue regeneration in the bottom of periodontal defect following open flap debridement alone. The aim of this study was to analyse the radiographic bone changes over 2-year after flap operation. Material and Methods: Patients attending the department of periodontics of Kyungpook National University Hospital were studied. Patients had clinical and radiographic evidence of infrabony defect(s). forty two sites of 33 patients aged 26 to 65 (mean age 45.5) were treated by flap operation with or without osseous surgery. Baseline and over 2-year follow-up radiographs were collected and evaluated for this study. Radiographic assessment includes a bone fill, bone crest change, defect resolution, and % of defect resolution. Pre- and post-treatment differences between variables (maxilla and mandible, gender, defect depth, defect angle) using the paired t-test were examined. Result: We observed 0.74 mm of bone fill, 0.66 mm of crestal resorption, 1.40 mm of defect resolution, and 27% of percentage of defect resolution. Mandible, women, deeper initial defect depth, narrower initial defect angle showed greater bone fill, defect resolution, and % of defect resolution. Conclusion: The results of this study suggest that the use of flap operation did enhance the outcome in terms of radiographically detectable bone fill. Both treatment resulted in some loss of crestal bone height.