• 제목/요약/키워드: Defect State

검색결과 348건 처리시간 0.027초

과전류에 의한 TFR-8 케이블의 과도상태 특성에 관한 연구 (A Study on the Transient State Characteristics of TFR-8 Cable caused by Over Current)

  • 김병조;김재호
    • 조명전기설비학회논문지
    • /
    • 제29권1호
    • /
    • pp.57-63
    • /
    • 2015
  • The incidence of fires caused by electrical factors has increased with the growth in domestic electrical consumption. According to the national fire data system of national emergency management agency, electrical fires accounted for 20% of all domestic fires in the last 10 years. Electrical fires are mainly caused by short circuit, leakage current, defect in an electrical equipment, over load, utility fault, etc. The fault current can be several times larger than the nominal current, thereby exceeding the rated current of cable. Consequently, the cable conductor, typically copper wire, heats up to a temperature that ignites surrounding combustibles. This paper describes the transient characteristics of the 0.6/1kV, TFR-8 cable have been investigated, and analyzed under the over current conditions for reduce the risk of electrical fire by experimental and FEM analysis. The experimental and FEM(Finite Element Method) analysis results of temperature and resistance variation according to the over current in copper wires were analyzed. The experimental results coincide well with the FEM analysis.

비접촉 초음파 탐상 기법을 이용한 항공기 브레이크 디스크의 신뢰성 평가 (Reliability Evaluation of Aircraft Brake Disk using the Non-contact Air-coupled Ultrasonic Transducer Method)

  • 곽남수;김재열;고가진;박대광
    • 한국기계가공학회지
    • /
    • 제15권3호
    • /
    • pp.36-43
    • /
    • 2016
  • Carbon fiber-reinforced silicon carbide (Cf-SiC) and SiC / SiC composites have high thermal conductivity, and excellent corrosion and wear resistance, a low coefficient for thermal expansion and are lightweight. This is why they are commonly used in parts of the aerospace industry to develop an aircraft thrust deflector, jet vane, combustion chamber, elevens, body flap, and a shingle. So, understanding how this state-of-the-art Cf-SiC affects both internal and external crack detection and determining issues during the manufacturing process of composite materials, should be evaluated according to valuation techniques in the external environment. In this paper, we apply a non-contact air ultrasonic technique of non-destructive testing techniques to perform a study on internal defect detection identification and assessment of carbon-fiber reinforced silicon carbide composites to perform basic research and applied research.

독립된 우심실 형성부전 - 1예 보고 - (Isolated Right Ventricular Hypoplasia -A case report-)

  • 이석기;서홍주;김웅한
    • Journal of Chest Surgery
    • /
    • 제36권9호
    • /
    • pp.683-686
    • /
    • 2003
  • 우심실 형성부전이 있으면서 단신방, 그리고 스펀지 좌심실이 있는 매우 드문 질환인 독립된 우심실 형성부전 환아를 경험하였다. 수술 전 우심실의 크기는 좌심실의 반이었으며 삼첨판막의 크기는 z-value로 -4이었다. 수술 시 6세였으며 수술은 양심실성 교정을 시도하여 심방을 2개로 나누어주었으며 3mm 구멍을 남겨 두었다. 수술 후 경과는 좋았으며 외래 추적에서 우심실 기능 부전소견은 없었다. 술 후 27개월에 심도자가 시행되었으며 삼참판막은 잘 자랐으며(z-value=-0.4), 심방중격의 구멍은 저절로 막혔음을 확인하였다. 독립된 우심실 형성부전을 경험하여 성공적으로 양심실성 교정을 시행하였기에 보고하는 바이다.

Correlation Between Energy Gap and Defect Formation of Al Doped Zinc Oxide on Carbon Doped Silicon Oxide

  • Oh, Teresa;Kim, Chy Hyung
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권4호
    • /
    • pp.207-212
    • /
    • 2014
  • Aluminum-doped zinc oxide (AZO) films were deposited on SiOC/Si wafer by an RF-magnetron sputtering system, by varying the deposition parameters of radio frequency power from 50 to 200 W. To assess the correlation of the optical properties between the substrate and AZO thin film, photoluminescence was measured, and the origin of deep level emission of AZO thin films grown on SiOC/Si wafer was studied. AZO formed on SiOC/Si substrates exhibited ultraviolet emission due to exciton recombination, and the visible emission was associated with intrinsic and extrinsic defects. For the AZO thin film deposited on SiOC at low RF-power, the deep level emission near the UV region is attributed to an increase of the variations of defects related to the AZO and SiOC layers. The applied RF-power influenced an energy gap of localized trap state produced from the defects, and the gap increased at low RF power due to the formation of new defects across the AZO layer caused by lattice mismatch of the AZO and SiOC films. The optical properties of AZO films on amorphous SiOC compared with those of AZO film on Si were considerably improved by reducing the roughness of the surface with low surface ionization energy, and by solving the problem of structural mismatch with the AZO film and Si wafer.

22.9kV급 케이블 결함 검출을 위한 초저주파 실험 및 현장 진단 분석 (Analysis of Diagnosis and Very Low Frequency Experiment to Detect of Fault on 22.9kV Class Cable)

  • 김영석;김택희;김종민;송길목
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1780-1785
    • /
    • 2016
  • This paper presents few case studies of state diagnosis of XLPE cables using very low frequency techniques. The power cables of 22.9kV which have installation fault were assessed using VLF technique in addition to other techniques like insulation resistance and DC voltage withstand test. From the experimental results, The dielectric loss($tan{\delta}$) values of degradation of the cable(joint, knife, needle) at $U_0$ were 5.839, 5.526 and 6.251, respectively and all values were "further study advised". VLF PD measurement was also found defective portion. These method was effective in defect to fault in the degradation of the cable. However, the breakdown did not occur in the degradation of the cable because of properties of XLPE insulation. Few case studies of using VLF $tan{\delta}$ diagnosis for fault are measured and analyzed. The $tan{\delta}$ values at $U_0$ were "further study advised" or "action required".

Bilateral Internal Superior Laryngeal Nerve Palsy of Traumatic Cervical Injury Patient Who Presented as Loss of Cough Reflex after Anterior Cervical Discectomy with Fusion

  • Shin, Dong-Uk;Sung, Joo-Kyung;Nam, Kyung-Hun;Cho, Dae-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권3호
    • /
    • pp.264-266
    • /
    • 2012
  • Injury to the bilateral internal branch of superior laryngeal nerve (ibSLN) brings on an impairment of the laryngeal cough reflex that could potentially result in aspiration pneumonia and other respiratory illnesses. We describe a patient with traumatic cervical injury who underwent bilateral ibSLN palsy after anterior cervical discectomy with fusion (ACDF). An 75-year-old man visited with cervical spine fracture and he underwent ACDF through a right side approach. During the post-operative days, he complained of high pitched tone defect, and occasional coughing during meals. With a suspicion of SLN injury and for the work up for the cause of aspiration, we performed several studies. According to the study results, he was diagnosed as right SLN and left ibSLN palsy. We managed him for protecting from silent aspiration. Swallowing study was repeated and no evidence of aspiration was found. The patient was discharged with incomplete recovery of a high pitched tone and improved state of neurologic status. The SLN is an important structure; therefore, spine surgeons need to be concerned and be cautious about SLN injury during high cervical neck dissection, especially around the level of C3-C4 and a suspicious condition of a contralateral nerve injury.

Intramedullary Spinal Cord Metastasis of Choriocarcinoma

  • Ko, Jun-Kyeung;Cha, Seung-Heon;Lee, Jung-Hwan;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권3호
    • /
    • pp.141-143
    • /
    • 2012
  • The authors describe a case of choriocarcinoma that metastasized to the cerebral cortex, vertebral body, and intramedullary spinal cord. A 21-year-old woman presented with sudden headache, vomiting and a visual field defect. Brain computed tomography and magnetic resonance examinations revealed an intracranial hemorrhage in the left temporo-parietal lobe and two enhancing nodules in the left temporal and right frontal lobe. After several days, the size of the hemorrhage increased, and a new hemorrhage was identified in the right frontal lobe. The hematoma and enhancing mass in the left temporo-parietal lobe were surgically removed. Choriocarcinoma was diagnosed after histological examination. At 6 days after the operation, her consciousness had worsened and she was in a state of stupor. The size of the hematoma in the right frontal lobe was enlarged. We performed an emergency operation to remove the hematoma and enhancing mass. Her mental status recovered slowly. Two months thereafter, she complained of paraplegia with sensory loss below the nipples. Whole spine magnetic resonance imaging revealed a well-enhancing mass in the thoracic intramedullary spinal cord and L2 vertebral body. Despite chemotherapy and radiotherapy, the patient died 13 months after the diagnosis.

모터링 시동 및 시동정지 사이클에서 경사진 축을 갖는 저어널베어링의 마모 해석 - Part II: 경사진 축을 지지하는 두 저어널베어링의 마모해석 (Wear Analysis of Journal Bearings Operating in a Shaft During Motoring Start-up and Coast-down Cycles - Part II: Wear Analysis of two Journal Bearings Supporting a Misaligned Shaft)

  • 전상명
    • Tribology and Lubricants
    • /
    • 제33권4호
    • /
    • pp.168-186
    • /
    • 2017
  • This paper presents a wear analysis procedure for calculating the wear of journal bearings during the start-up and coast-down cycles of a motoring stripped-down single cylinder engine operating with a tilted shaft. In order to decide whether the lubrication state of a journal bearing is in the mixed-elasto-hydrodynamic lubrication regime, we utilize lift-off speed and MOFT (most oil film thickness) under mixed-elasto-hydrodynamic lubrication regime at the corresponding aligned shaft. We formulate an equation for the modified film thickness in a misaligned journal bearing considering the additional wear volume described in Part I of this study. For this, we use the calculation results of the degree of misalignment and tilting angle obtained after finding the eccentricities of the two bearings supporting the crankshaft of a single cylinder engine. In this Part II, we calculate the wear of journal bearings using the fractional film defect coefficient, the asperity load sharing factor, and the modified specific wear rate for the application of mixed-elasto-hydrodynamic lubrication regime. We show that the accumulated wear volume after turning the ignition switch on and off once, increases to ${\sigma}=39{\mu}m$ and then decreases from ${\sigma}=39{\mu}m$ with increasing in surface roughness.

Lithium 투약도중 과나트륨혈증과 섬망을 동반한 신장성 뇨붕증 환자 1례 (A Case of Nephrogenic Diabetes Insipidus with Delirium and Hypernatremia due to Lithium Medication)

  • 정효경;이영호;정영조
    • 정신신체의학
    • /
    • 제4권1호
    • /
    • pp.91-97
    • /
    • 1996
  • Lithium is a widely used important drug in the treatment of manic-depressive illness and its prevention of relapse. However, this drug has a Low therapeutic index, therefore, it has many attendant side effects. The most prevalent renal effect of lithium is impairment of concentrating ability and this defect appeared into overt polyuria. A renal lesion is confined to the collecting tubule and 12-20% of patients taking lithium suffer from nephrogenic diabetes insipidus. This nephrogenic diabetes insipidus causes the states of extracellular fluid depletion, hypernatremia and precipitates lithium intoxication. In such situation, symptoms of nephrogenic diabetes insipidus and lithium intoxication are very similar, so we should be very cautious to discriminate them. We herein report a patient characterized by a prolonged stuporous state, hypernatremia and severe nephrogenic diabetes insipidus during lithium therapy.

  • PDF

3D 프린터를 이용하여 턱관절 MRI검사에 사용되는 TMJ device제작 (Additive Manufacturing of TMJ Device used in Temporomandibular Joint MRI Scan by using 3D Printer)

  • 장혜원
    • 한국콘텐츠학회논문지
    • /
    • 제18권7호
    • /
    • pp.628-634
    • /
    • 2018
  • 턱관절 디스크 검사 시 MRI는 유용한 검사법으로 디스크의 정확한 위치변화를 관찰하고자 개구상태에서 오랜 시간 검사가 필요하다. 이에 3D프린팅 기술을 이용하여 개구상태를 유지시켜 줄 고정 장치(TMJ device)를 제작하고 이를 기존 고정 장치와 비교하여 유용성을 평가하고자 하였다. 기존 TMJ device를 사용한 영상에 비해 3D 프린터로 자체 제작한 TMJ device를 사용한 영상에서 SNR이 다소 낮은 결과를 보였지만 임상적으로 사용하는데 큰 결함이 없고 환자 개인별 특화된 맞춤형 제작이 가능하고 더불어 3D 프린팅 기술을 활용하여 유사도구 제작에 기여함으로서 비용대비 편익이 상승될 것이라 사료된다.