• Title/Summary/Keyword: Decreasing device

Search Result 231, Processing Time 0.032 seconds

Improved Low-temperature Performance of Lithium Secondary Battery Using Energy Circulating Operation (리튬 이차전지의 저온 성능 개선을 위한 에너지 순환 작동 연구)

  • Yoon, Hyun-Ki;Ha, Sang-Hyeon;Lee, Jaein
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.6
    • /
    • pp.421-428
    • /
    • 2021
  • Lithium-ion secondary batteries exhibit advantageous characteristics such as high voltage, high energy density, and long life, allowing them to be widely used in both military and daily life. However, the lithium-ion secondary battery does have its limitation; for example, the output power and capacity are readily decreased due to the increased internal impedance during discharging at a lower temperature (-32℃, military requirement). Also, during charging at a lower temperature, lithium dendrite growth is accelerated at the anode, thereby decreasing the battery capacity and life as well. This paper describes a study that involves increasing the internal temperature of lithium-ion secondary battery by energy circulation operation in a low-temperature environment. The energy circulation operation allows the lithium-ion secondary battery to alternately charge and discharge, while the internal resistance of lithium-ion battery acts as a heating element to raise its own temperature. Therefore, the energy circulation operation method and device were newly designed based on the electrochemical impedance spectroscopy of the lithium-ion secondary battery to mediate the battery performance at a lower temperature. Through the energy circulation operation of lithium ion secondary battery, as a result of the heat generated from internal resistance in an extremely low-temperature environment, the temperature of the lithium-ion secondary battery increased by more than 20℃ within 10 minutes and showed a 75% discharging capacity compared with that at room temperature.

Effects of Posterior Oblique Sling Activation on Gluteus Maximus Muscle Activity during Prone Hip Extension Exercises in Healthy Male Individuals

  • Byeong-Hun Hwang;Sung-Dae Choung;No-Yul Yang;In-Cheol Jeon
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.1
    • /
    • pp.13-18
    • /
    • 2023
  • Purpose: The purpose of this study was to investigate the effects of posterior oblique sling activation on the muscle activities of the gluteus maximus (GM), multifidus (MF), and biceps femoris (BF) during three different prone hip extension exercises in healthy male individuals. Methods: Twenty healthy subjects participated in this study. An electromyography device was used to measure the muscle activities of the GM, MF, and BF. Each subject was asked to perform three different prone hip extensions as follows: [1) Prone hip extension with knee flexion + hip abduction 30°; PHE1, 2) Prone hip extension with knee flexion + hip abduction 30° and shoulder abduction 125°; PHE2, 3) Prone hip extension with knee flexion + hip abduction 30° and shoulder abduction 125° with 1kg loading; PHE3, in random order. A one-way repeated measures analysis of the variance and a Bonferroni post hoc test were used to analyze the results. The statistical significance was set at α=0.01. Results: The muscle activity of the GM was significantly different between the three positions (Padj<0.01). The muscle activity of the GM was significantly greater during PHE3 compared with PHE1 and PHE2 (Padj<0.01). The BF muscle activity was significantly lower during PHE3 compared with PHE1 and PHE2 (Padj< 0.01). There was no significant difference in the muscle activity of the MF (Padj<0.01). The ratio of the muscle activity (ratio=GM/BF) during PHE3 was significantly greater compared to PHE1 and PHE2 (Padj< 0.01). Conclusion: The GM activity and GM/BF ratio during the PHE3 exercise were significantly greater compared to that during PHE1 and PHE2. Therefore, the PHE3 exercise could be recommended as a selectively effective GM activation exercise while decreasing the muscle activity of the BF.

Evaluation of the Usefulness for VMAT of multiple brain metastasis using jaw tracking (Jaw tracking을 이용한 다발성 뇌 전이의 용적세기조절회전치료에 대한 유용성 평가)

  • Kim, Tae Won;Yoo, Soon Mi;Jeon, Soo Dong;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.73-81
    • /
    • 2018
  • Purpose : The aims of this study were to compare and assess the effectiveness of Volumetric Modulated Arc Therapy(VMAT) using jaw tracking(JT) and fixed jaw(FJ) in radiation therapy of multiple brain metastasis. Methode and material : Among the patients with Multiple Brain Metastasis treated with jaw tracking, 10 patients with more than 6 tumors and with the size of radiation field $14{\times}14cm^2$ or more were included. Each Treatment plans with jaw tracking(JT) and fixed jaw(FJ) was established with Eclipse (Ver. 13.6 Varian, USA). Gamma Index (3 mm, 3 % confidence interval - 95 %) and maximum dose difference were measured with an electronic portal imaging device(EPID). The $D_{max}$ and $D_{mean}$ of Organ At Risk(OAR) were assessed and compared, and the Conformity Index(CI) and Homogeneity Index(HI) were evaluated. Result : Evaluating jaw tracking(JT) and fixed jaw(FJ) outcomes, in all cases, Gamma Index met the permissible standard of 3 mm, 3 % confidence intervals of 95 %. The maximum dose difference value from the areas with leaf end transmission was measured at a maximum of 98.4 % and an average of 43.6 % in clockwise(CW), and 67.9 % and 41.0 % for each in Counter-Clockwise(CCW). With jaw tracking, the maximum value of $D_{max}$ for each normal organ in OAR decreased in 15.36 %~74.59 % with the average value decreasing in 2.84 %~39.80 %. The maximum value of $D_{mean}$ in OAR decreased in 27.90 %~65.23 %, with the average value decreasing in 7.70 %~41.71 %. No change has been found in Conformity Index and Homogeneity Index values. Conclusion : When Jaw tracking is used in treating patients with multiple brain metastasis with VMAT, the unnecessary exposure due to leakage and transmission of radiation in unspecified areas was reduced, without affecting the dose distribution of the planning target volume(PTV), and the availability of radiation therapy with lower doses in normal organs is expected.

  • PDF

A Study on Comparison of Outdoor Wind Pressure Performance According to Outdoor Exposure and Acceleration Deterioration Methods of Structural Sealants Applied to Curtain Wall (커튼월에 적용된 구조용 실링재의 옥외폭로와 실내복합열화 처리방법에 따른 내풍압성능 비교연구)

  • Jang, Pil Sung;Hong, Soon Gu;Kim, Sung Rae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.279-287
    • /
    • 2018
  • Sealants are an important element of modern architecture and serve as a building protection against weathering by providing barriers against ingress of moisture, air, and other materials. Exposure to a variety of environments often reduces lifespan due to changes in physical, chemical and mechanical characteristics, and UV, humidity, and temperature expansion are important issues that are directly related to durability. In this study, a combined deterioration test chamber was developed to simulate the environment of the open air as an instrument for verifying the durability of structural sealing materials indoors. In order to replicate special weather conditions, such as yellow dust, acid rain, and contamination by microorganisms, it was deemed impossible to replicate the outdoor environment by 100 %, and the results of the results of the results of the external exposure test of the structural sealant and the combined deterioration testing device. As a result of the displacement test of the outdoor exposure test, it was determined that the sealant was breaking apart and that it would be smooth, and the displacement would be up to three times greater than the initial material value of 1 year. The displacement test results of the combined deterioration test device show the tendency to deteriorate, decreasing the elasticity and tensile characteristics. In the case of denatured silicon, the current 400 cycles have been completed to confirm 12 months of degradation of the external exposure. The deformation of the test specimen cannot be verified with the naked eye, so it is considered that the conditions of the specimen are more stable than the silicon sealant. As a result of the outdoor exposure test, if the combined deterioration test device is structured and proposed in the relevant guidance or specification, the anticipated lifespan of 12 months in the actual use environment can be verified indoors and below 3 months later, economically.

Photoelastic stress analysis of the mandibular unilateral free-end removable partial dentures according to the design (하악 편측 유리단 가철성 국소의치의 설계에 따른 광탄성 응력 분석)

  • Park, Cheol-Woo;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.206-214
    • /
    • 2009
  • Statement of problem: There are common clinical cases in which the mandibular first and second molars are missing unilaterally. Purpose: This study was designed to compare and evaluate the magnitude and distribution of stress produced by four kinds of mandibular unilateral free-end removable partial dentures that could be applied clinically in Kennedy class II cases. Material and methods: Four unilateral free-end removable partial dentures using clasp, Konus crown, resilient attachment, and flexible resin were fabricated on the photoelastic models of the Kennedy class II cases. The vertical load of 6㎏ was applied on the central fossa of the first molar of every removable partial denture in the stress freezing furnace and the photoelastic models were frozen according to the stress freezing cycle. After these models were sliced mesio-distally to a thickness of 6mm, the photoelastic isochromatic white and black lines of the sliced specimens were examined with the transparent photoelastic experiment device and photographs were taken with a digital camera. The fringe order numbers at eight measuring points in the photograph were measured with the naked eye. Results: The maximum fringe order number of each sliced specimen and the fringe order number at the residual ridge just below the loading point were in the decreasing order of the unilateral removable partial dentures using flexible resin followed by clasp, resilient attachment, and Konus crown. The fringe order number at the root apex of the second premolar was in the decreasing order of the unilateral removable partial dentures using clasp followed by flexible resin, Konus crown, and resilient attachment. Conclusion: The removable partial denture using Konus crown showed the most equalized stress distribution to the supporting alveolar bone of abutment teeth and residual ridge under the vertical loads. The removable partial denture using flexible resin can be applied to the case that has a better state of residual ridge than abutment teeth.

A Study on the Exporter's Measures against Credit Risks in International Payment System - focus on international factoring.forfaiting - (국제대금결제에서의 신용위험 대처방안에 관한 연구 - 국제팩토링.포페이팅을 중심으로 -)

  • Oh, Won-Suk;Park, Se-Hun
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.39
    • /
    • pp.143-175
    • /
    • 2008
  • The documentary letter of credit is the most preferred and frequently used method in International Payment System in Korea, as it has less possibility of occurring credit risks in export than any other payment system. That's because the exporter can get payment from the issuing bank(confirming bank) by delivering the goods and presenting documents following the required procedure under the letter of credit, as the payment is affirmed by the issuing bank(including the confirming bank in case of the confirmed letter of credit) regardless of the buyer's payment. However, the pattern of payment methods used in international trade of Korea is changing dramatically like the importance of the credit is decreasing continuously among the payment methods while the remittance is increasing. The increase of remittance has a positive aspect that International Payment System are changing into those of advanced countries, but the decrease of the credit also has a negative aspect that the exporter might have a greater credit risks. Therefore, we need a systematic device to deal with this. Exporters in Korea usually have used the export credit insurance to deal with the credit risks However, the export credit insurance also have a limitation as the policy finance due to the limitation based on the credit status of the business and the limitation of acceptance from the lack of financial resources of the government, etc. Korea, which is the 11th export power in the world, has a basic limitation to deal with the credit risks by depending on the export credit insurance only. So, in this thesis, I have studied on the international factoring, forfaiting, which are advanced export finances and widely used in advanced countries, as substitutes to deal with the credit risks. the international factoring is an trade financing in which a factor offers full services such as credit cover, offering prepayment, collection, account receivables, management, etc, instead of the exporter on the account receivables occurred by the exporter's delivering goods to the importer. This international factoring has a high possibility of using as a means to deal with the credit risks, because it offers prepayment without recourse. the forfaiting is another export financing in which a forfaiter purchases the draft, the promissory note and other negotiable instruments issued from the international trade, with fixed interest rate without recourse from the exporter or previous holder. By using this method, they can avoid foreign exchange risks, contingency risks as well as credit risks, as the conveyances like the promissory note, etc are issued with the note warranty so-called 'per aval' in business practice. These trade financing are good substitutes to deal with the credit risks in export, but they are not widely used in Korea. Though it can be explained with various reasons, the common reasons are the lack of understanding on the use of advanced export finance, the lack of experts to manage the advanced trade finance, the conservative way of thinking of domestic organizations related to trade financing, the lack of organizations supporting the trade financing, etc.

  • PDF

Effect of operating temperature using Ni-Al-$ZrH_2$ anode in molten carbonate fuel cell (Ni-Al-$ZrH_2$ 연료극을 사용한 용융탄산염 연료전지의 온도의 영향)

  • Seo, Dongho;Jang, Seongcheol;Yoon, Sungpil;Nam, Suk Woo;Oh, In-Hwan;Lim, Tae-Hoon;Hong, Seong-Ahn;Han, Jonghee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.134-134
    • /
    • 2010
  • Fuel cell is a device that directly converts chemical energy in the form of a fuel into electrical energy by way of an electrochemical reaction. In the anode for a high temperature fuel cell, nickel or nickel alloy has been used in consideration of the cost, oxidation catalystic ability of hydrogen which is used as fuel, electron conductivity, and high temperature stability in reducing atmosphere. Most MCFC stacks currently operate at an average temperature of $650^{\circ}C$. There is some gains with decreased temperature in MCFC to diminish the electrolyte loss from evaporation and the material corrosion, which could improve the MCFC life. However, operating temperature has a strong related on a number of electrode reaction rates and ohmic losses. Baker et al. reported the effect of temperature (575 to $650^{\circ}C$). The rates of cell voltage loss were 1.4mV/$^{\circ}C$ for a reduction in temperature from 650 to $600^{\circ}C$, and 2.16mV/$^{\circ}C$ for a decrease from 600 to $575^{\circ}C$. The two major contributors responsible for the change in cell voltage with reducing operation temperature are the ohmic polarization and electrode polarization. It appears that in the temperature range of 550 to $650^{\circ}C$, about 1/3 of the total change in cell voltage with decreasing temperature is due to an increase in ohmic polarization, and the electrode polarization at the anode and cathode. In addition, the oxidation reaction of hydrogen on an ordinary nickel alloy anode in MCFC is generally considered to take place in the three phase zone, but anyway the area contributing to this reaction is limited. Therefore, in order to maintain a high performance of the fuel cell, it is necessary to keep this reaction responsible area as wide as possible, that is, it is needed to keep the porosity and specific surface area of the anode at a high level. In this study effective anodes are prepared for low temperature MCFC capable of enhancing the cell performance by using zirconium hydride at least in part of anode material.

  • PDF

Oxygen Transfer System in Biological Fluidised Bed Using the Deep Shaft as Aeration Device (생물학적(生物學的) 유동층(流動層)을 이용(利用)한 폐수처리(廢水處理)에 있어서의 심층(深層) 폭기장치(曝氣裝置)에 의한 산소전달(酸素傳達) 시스템)

  • Kim, Hwan Gi;Ahn, Song Yeob;Jeong, Tae Seop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.13-24
    • /
    • 1988
  • This paper is concentrated on the development of oxygen transfer system by U-tube deep shaft in biological fluidised bed process. The depth of the shaft is 32 m, it is composed of downcomer and riser. Not only flow pattern and oxygen transfer in the deep shaft but also oxygen limitation in biofilm and oxygen utilization in biological fluidised bed are investigated. In this investigation, driving force for liquid circulation in the deep shaft is affected by air injection depth and gas hold-up in downcomer. Flow pattern of the deep shaft is revealed to plug flow. When flow velocity in the deep shaft is maintained to 0.52 m/sec, $K_La$ value is peak at 25~30 m depth in riser. The efficiency of dissolved oxygen supply which passed from the deep shaft to biological fluidised bed is estimated to 56~81 % in the organic wastewater treatment using the deep shaft and when dissolved oxygen concentration is 9.2 mg/l and over, limiting factors of flux and substrate within biofilm are organic materials. Terefore, organic loadings could be increase without decreasing of BOD removal efficiency.

  • PDF

Effect of In Vivo Embryo Production and Embryo Transfer Following Superovulation in Hanwoo (다배란 처리에 따른 한우 체내 수정란 생산 효율과 수정란이식)

  • Cho, Sang-Rae;Choi, Sun-Ho;Choe, Chang-Yong;Son, Jun-Kyu;Choi, Soo-Ho;Kim, Young-Joo;Lee, Poong-Yeon;Yeon, Sung-Heum;Kim, Hyun-Jong;Son, Dong-Soo
    • Journal of Embryo Transfer
    • /
    • v.25 no.3
    • /
    • pp.141-144
    • /
    • 2010
  • In vivo embryo produced from Hanwoo donor cows were collected and transferred to Hanwoo recipients. Cows, at random stages of the estrous cycle, received Progesterone Releasing Intravaginal Device (CIDR-plus, InterAg, New Zealand) together with injection of 1 mg estradiol benzoate and 50 mg progesterone, and gonadotropin treatment began 4 day later. For superovulation, a total of 28 mg FSH was intramuscularly injected twice a day in the way of decreasing doses 4 day (5, 5, 4, 4, 3, 3, 2 and 2 mg). Twenty one Hanwoo donor cows were flushed on day 7 of estrus cycle with same FSH and artificial insemination by the same technicians. Embryos were recovered 7 days after the second insemination by flushing the uterus with Embryo Collection Medium. The results obtained were as follows: The rates of transferable embryos were 50.3%, and 78 fresh embryos at morulae and blastocysts stage were transferred into Hanwoo recipients on day 7 of estrus cycle. The pregnancy rates were first embryo transfer 55.6%, 2nd 62.9% and 3rd 57.9%, respectively. In conclusion, These results suggest that CIDR-based superovulation protocol may be effectively used for production of superior Hanwoo embryos. Also, since it seems the condition of recipient cows greatly affect pregnancy rate, it is very important to evaluate recipient for effective cattle production.

Development of Reefer Container Real-time Management System (실시간 냉동컨테이너 관리 시스템 개발)

  • Choi, Sung-Pill;Jung, Jun-Woo;Moon, Young-Sik;Kim, Tae-Hoon;Lee, Byung-Ha;Kim, Jae-Joong;Choi, Hyung-Lim;Lee, Eun-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.12
    • /
    • pp.2917-2923
    • /
    • 2015
  • In spite of a recent trend of container ships becoming larger in size, the current circumstance is that managing reefer containers marine transportation is being mostly dependent upon manpower. Particularly, in the case of bad weather or nighttime, reefer containers are not being monitored due to lack of safety device. For the purpose of reducing such risk, IMO is recommending a system using PLC but the system is not being used. In addition, they are still relying on manpower for control and reliability of freight in transit is decreasing due to lack of information during marine transportation for every subject related to freight as well as shipper. Accordingly, the purpose of this paper is to propose a real-time reefer container management system to effectively control all reefer containers widely being used across the world.