• Title/Summary/Keyword: Dead body

Search Result 252, Processing Time 0.023 seconds

Design of a PWM DC-DC Boost Converter with Adaptive Dead-Time Control Using a CMOS 0.18um Process (CMOS 0.18um 공정을 이용한 Dead-Time 적응제어 기능을 갖는 PWM DC-DC Boost 변환기 설계)

  • Hwang, In-Ho;Yoon, Eun-Jung;Park, Jong-Tae;Yu, Chong-Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.285-288
    • /
    • 2012
  • Since the non-overlapping gate driver used in conventional DC-DC boost converters generates fixed dead-times, the converters suffer from the body-diode conduction loss or the charge-sharing loss. To reduce the efficiency degradation due to these losses, this paper presents a PWM DC-DC boost converter with adaptive dead-time control. In light loads, power switching is also employed to increase the efficiency. The designed DC-DC boost converter can thus achieve high efficiency at wide current range. The proposed DC-DC boost converter has 3.3V output from a 2.5V input with 0.18um technology. It operates at 500KHz and has a maximum power efficiency of 97.8%.

  • PDF

A Study of Choson Shrouds and Current Shrouds How the Deceased Are Clothed (조선시대 수의와 현행 수의의 착의법에 관한 연구)

  • 남민이;한명숙
    • The Research Journal of the Costume Culture
    • /
    • v.8 no.6
    • /
    • pp.822-841
    • /
    • 2000
  • The purpose of this study is to organize how the deceased are clothed. Although there are many people who have seen the dead clothed once or twice and although the clothing has been constantly going on, there have been no books or studies on how the deceased are clothed. Instead, the methods have only been handed down orally by seniors and others who are experienced in it. I see the necessity of systematizing the method of clothing the deceased so that both ordinary people as well as experts can utilize it properly to show their sincerity and courtesy towards the dead. This study is based on literature including old books, dissertations, publications, and reports on ethnic customs. It also refers from interview results of shrouds makers, those experienced in clothing the dead, and seniors knowledgeable in the trade. Funeral manifested the social status of the dead. Shrouds of the olden days had different colors, such as white, black, blue, red, etc. according to items. However, nowadays they are white, pink, or partially light blue or sometimes people just keep the colors of their original cloths. Current items do not differ much from those of the ancient times, though Kwadu, Km, and Po, which were used to cover the belly, have been relatively simplified. The form of shrouds has changed nowadays. There are differences in the funeral procedures and how the deceased are clothed. In the olden days, when a person died, the body was cleaned up and clothed the very next after death. Nowadays, the cleansing and clothing of the body and placing the body in the coffin are all done together the following day. According to the foregoing, though there are no big differences in the way the deceased are clothed between the olden days and the present, the order in which Aksu and B누 are placed, differs and the procedures, items and shape have been simplified.

  • PDF

Community Characteristics and Assessment of Water Quality Impact by Plants at Flooded Area (저수지역 식물의 군집특성 및 수질영향 평가)

  • Lee, Yosang;Kim, Hojoon;Jeong, Seon A
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.6
    • /
    • pp.407-415
    • /
    • 2006
  • This study carried out submerged area due to Dam construction in the near future. It includes species classification of plant, survey of community structure, examination of pollutant load and assessment of water quality impact. The vascular plants of this area are listed 224 taxa; 64 families, 168 genera, 193 species, 30 varieties and 1 form. This study area is classified into total 21 communities, most community was consist of grass vegetation. Among the communities, Erigeron annuus ($869,286m^2$, 22%) community was dominant and Erigeron annuus-Avena fatua comminity (16%) was subdominant until May, and then Erigeron canadensis community occupied most area to $1,774,985m^2$ (32%) from May to July. For the evaluation of water quality impact due to submerged macrophyte, nutrient release test was conducted both dead body macrophyte and living body macrophyte. The results of release test show that T-N is not released at dead body macrophyte, but it is released at living body macrophyte, especially living body Artemisia priceps var. orientalis shows 1.436mgN/g. At release test of dead body macrophyte, T-P release rate of Erigeron annuus shows 0.500mgP/g at the top of them and it also shows 0.436mgP/g at Erigeron annuus of living body macrophyte. T-N load of submerged macrophyte shows 0.76% by comparison of total load on watershed and T-P load of that shows 3.61%. In case of removal macrophyte for reduction of pollutant load in submerged area, T-N load of submerged macrophyte changes from 0.76% to 0.15% by comparison of total load on watershed and T-P load of that changes from 3.61% to 0.72%.

Fire Patterns Based on the Hb-CO Concentration (헤모글로빈-일산화탄소 농도에 따른 연소형태)

  • Choi, Seung-Bok;Oh, Bu-Yeol;Choi, Don-Mook
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.373-377
    • /
    • 2011
  • Fire patterns have been used to determine the origin and cause of fires in every setting imaginable. However, it is very difficult to identify fire patterns from the fire-damaged remains of a devastated structure. If someone was killed by the fire, it is possible to identify fire patterns by analyzing the concentration of carbon monoxide-hemoglobin in the body of deceased as well as the pace of the fire. For example, a low level of carbon monoxide-hemoglobin in the body of the dead indicates a rapid fire with accelerants and the death was caused by severe heat and thick toxic fumes. However, a high level of carbon monoxide-hemoglobin in the body of the dead demonstrates that the fire was slow and/or there was a flameless form of combustion. Thus, this study identifies fire patterns through analyzing the level of carbon monoxide-hemoglobin concentration on the dead from the fire.

  • PDF

DC-DC Boost Converter with Dead-Time Adaptive Control and Power Switching (Dead-Time 적응제어 기능과 Power Switching 기능을 갖는 DC-DC 부스트 변환기)

  • Lee, Joo-young;Yang, Min-jae;Kim, Doo-Hoi;Yoon, Eun-jung;Yu, Chong-gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.361-364
    • /
    • 2013
  • Since the non-overlapping gate driver used in conventional DC-DC boost converters generates fixed dead-times, the converters suffer from the body-diode conduction loss or the charge-sharing loss. A adaptive control method has been proposed to reduce these loses. In this method, however, occurrence of and overlapping time of two power transistors in CCM results in reduction of efficiency. In this paper, to overcome this problem a new adaptive control method in proposed, and a DC-DC boost converter with the proposed adaptive control and power switching has been designed in a 0.35um CMOS process. The designed converter outputs 3.3V from a input voltage of 2.5V. The switching frequency is 500kHz and the maximum power efficiency is 95.3% at a load current 150mA. The designed chip area is $1720um{\times}1280um$.

  • PDF

Acute and Subacute Toxicity Study of Artemisia asistica Nakai Aqua-acupuncture Solution in Mice (애엽(艾葉) 약침액(藥鍼液)의 급성(急性)·아급성(亞急性) 독성(毒性)에 관한 연구(硏究))

  • Youn, Seong-Muk;Lim, Jong-Kook
    • Journal of Acupuncture Research
    • /
    • v.17 no.1
    • /
    • pp.143-151
    • /
    • 2000
  • Acute and subacute toxicity of Artemisia asistica Nakai Aqua-acupuncture Solution (ANAS) were studied in ICR mice. In acute toxicity test, mice were injected intraperitoneally with single dose of $1{\times}$, $5{\times}$, $10{\times}$ ANAS, and toxicological responeses were observed for consecutive 14 days. Mortality, body weight changes, organ weight, and serum chemistry were performed. The mortality and body weight changes of mice treated with $1{\times}$ and $5{\times}$ ANAS were not affected during the experimental periods. With the $10{\times}$ ANAS treatment, there were dead animals and changes of body weight, organ weight and serum biochemical values were observed during the experimental period. In subacute toxicity test, mice were injected intraperitoneally with doses of $1{\times}$, $10{\times}$ ANAS for 14 days. No difference was found between control and $1{\times}$ ANAS treated group in mortality, changes of body weight and organ weight, and serum biochemical values. However, Dead animals, changes of body weight and organ weight, and increased serum biochemical values were observed with $10{\times}$ ANAS treated groups. These results suggest that $1{\times}$ ANAS causes no toxicity in acute and subacute toxicity tests. However $10{\times}$ ANAS causes toxicity in both tests.

  • PDF

The Comparative Analysis on the Kinematic Variables according to the Types of Stance in the Dead-lift of Snatch Events of Junior Weight Lifters (주니어 역도 선수 인상 종목의 Dead-lift 동작 시 스탠스유형에 따른 운동학적 변인 비교분석)

  • Chung, Nam-Ju;Kim, Jae-Pil
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.99-107
    • /
    • 2008
  • The aim of this study was to provide fundamental data in training to improve athletes' competitiveness through the comparative analysis of kinematic variables according to the types of stance. For this study, the subjects selected 4 Junior Weight lifters. Subjects performed two type(8-type and 11-type) Dead-lift and their performance was sampled at 60frame/sec. using four high-speed digital video cameras. After digitizing images from four cameras, the two-dimensional coordinates were used to produce three-dimensional coordinates of the 15 body segments(20 joint makers and 2 bar makers). And the results were as follows. 1. As for the time required for stances, 8-type motion was faster than 11-type motion. 2. As for the body-center shift in stances, 8-type motion was bigger than 11-type motion in back and forth motion shift, and 11-type motion was bigger than 8-type motion in right and left, up and down motion shift. 3. As for the speed of a body-center and a babel, 8-type motion was faster than 11-type motion. 4. As for the motion-trace of a babel in stances, 8-type motion was bigger than 11-type in back and forth, right and left motion and 11-type motion was bigger than 8-type in up and down motion. 5. As for the body-angles in stances, 8-type motion was bigger than 11-type in the stance angle, and 11-type motion is bigger than 8-type in the angles of a coxa, a knee and an ankle. As a result of the comparative analysis between 8-type and 11-type stance of Junior Weight lifters dead-lift, both were generally similar in variables, but 8-type motion was more stable than 11-type in aspects of time, speed, center shift, angle change.

Efficiency Improvement of Synchronous Boost Converter with Dead Time Control for Fuel Cell-Battery Hybrid System

  • Kim, Do-Yun;Won, Il-Kuen;Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1891-1901
    • /
    • 2017
  • In this paper, optimal control of the fuel cell and design of a high-efficiency power converter is implemented to build a high-priced fuel cell system with minimum capacity. Conventional power converter devices use a non-isolated boost converter for high efficiency while the battery is charged, and reduce its conduction loss by using MOSFETs instead of diodes. However, the efficiency of the boost converter decreases, since overshoot occurs because there is a moment when the body diode of the MOSFET is conducted during the dead time and huge loss occurs when the dead time for the maximum-power-flowing state is used in the low-power-flowing state. The method proposed in this paper is to adjust the dead time of boost and rectifier switches by predicting the power flow to meet the maximum efficiency in every load condition. After analyzing parasite components, the stability and efficiency of the high-efficiency boost converter is improved by predictive compensation of the delay component of each part, and it is proven by simulation and experience. The variation in switching delay times of each switch of the full-bridge converter is compensated by falling time compensation, a control method of PWM, and it is also proven by simulation and experience.

The Effect in the Muscle Function Following 8-Week Dead-lift training with Whole-body Vibration in Rehabilitation for Sports Players (8주간 데드리프트 운동 시 전신진동운동이 재활스포츠 선수의 근 기능 특성에 미치는 영향)

  • Oh, Ju-Hwan;Kang, Seung-Rok;Min, Jin-Young;Kwon, Tae-Kyu
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.3
    • /
    • pp.343-351
    • /
    • 2015
  • Objective : The purpose of this study was to investigate the effects in the muscle function following 8-week dead-lift training with Whole-body Vibration(WBV) in rehabilitation for sports players. Method : Twenty young sports players. Each subjects were randomly assigned to a resistance training with Whole-body vibration group(TG, n=10), a resistance training without Whole-body vibration group(CG, N=10). The measurements which physical fitness test and joint torque test were performed before the randomization and after the 4-week and 8-week. The WBV group performed the dynamic Dead-lift exercise on a vibration platform during one minute. The CG group performed the equal training without vibration. The WBV and CON group repeated 5 set and trained two times weekly for 8-weeks. Paired t-test was used to test for differences between the groups at baseline and after 4-weeks and 8-Weeks. And independent t-test was used to test for differences between the groups at TG and CG. All analyses were executed using SPSS software 18.0. The level of significance was set at p<.050. Results : Following the 8-Weeks training sessions, an increase in the back-muscle strength was found to be greater for the TG compared with the CG group(p<.05). Muscle endurance was significantly decreased after training than before training only for the CG(p<.05). Isometric Hip/Lumber Extension/Flextion measurement was found to be significantly greater for the TG compared with the CG group(p<.05). The finding indicates that WBV effects as an efficient training stimulus to enhance muscle function by facilitating neural control trail. Following muscle activation in motor unit synchronization of the co-contraction of the muscles. Conclusion : The results imply that the WBV training may have enhanced muscle function in rehabilitation for sports players.

The Characteristic Improvements of One-Coil Coin Type Vibration Motor (One-Coil Coin Type Motor의 특성 개선)

  • Kwak, Dong-Soo;Kim, Sang-Gil;Shin, Heung-Kyo;Kweon, Chang-Myoung
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.327-329
    • /
    • 2000
  • This paper present the characteristic improvements of one-coil coin type vibration Motor. Rotor is consist of coreless coil and 4 segment commutator. Magnet is 4 pole, z direction magnetized. This one-coil coin type vibration motor has simple mechanical structure and good efficiency. So production cost is lower than other having 2 or more coils coin type motor but it has the weak points. That is small vibration magnitude and dead zone. Modifying the shape of rotor, vibration magnitude is increased. To avoid the dead zone we attached more magnetic body on rotor. As result we show the optimal position of magnetic body.

  • PDF