• 제목/요약/키워드: Daylight performance

검색결과 132건 처리시간 0.019초

정밀 전천공조도 데이터를 활용한 국내 주요도시 업무용 건물의 자연채광 활용성능 평가 (Evaluation of Daylighting Performance in Office Building with Detailed Global Illuminance Data of Selected Korean Cities)

  • 최수현;신상용;서동현
    • 한국태양에너지학회 논문집
    • /
    • 제36권6호
    • /
    • pp.37-46
    • /
    • 2016
  • In this study, long-term global illuminance data for 19 selected cities are calculated from modeled solar radiation data, AEER's TMY2. Perez model in Daysim daylight simulation tool is used for the solar radiation to illuminance conversion. And then, daylight availability in an unit office space is evaluated for the 19 cities. For this evaluation, various daylight performance indices are reviewed since static daylight performance index such as daylight factor (DF) and annual average global illuminance value is not suitable for actual performance evaluation in terms of visual comfort and light energy saving of a space. This study evaluated daylighting performance of prototypical office space module by introducing DA (daylight autonomy) and UDI (Useful Daylight Illuminance) index for major cities of Korea. Result shows that there is upto 18% of illuminance level difference with annual average global illuminance data, but if we consider useful daylight in a space the illuminance level difference among the cities are only within 5%. This means that for sustainable building design especially in daylight design, amount of annual global illuminance is not important factor even in cloudy cities. Daylight design and daylight harvesting system would return similar energy saving impact regardless of building location.

광센서 조광제어시스템의 성능평가를 위한 소프트웨어 개발 (Development of software for the system performance of daylight responsive dimming systems)

  • 황민구;최안섭
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.133-136
    • /
    • 2005
  • Recently, a drain of energy resources is issued seriously. The daylight responsive dimming systems can reduce electric energy uses. But, we cannot predict amounts of energy-saving and accuracy of system performance. Therefore, the purpose of this study is a development of software for the system performance of daylight responsive dimming systems. The principle of this software based on luminous flux transfer method and finite elements method. The control algorithm of this software and daylight responsive dimming systems use the same algorithm. In addition the advantages of this software are use to same algorithm of daylight responsive dimming systems, electric power-luminous flux data and rates of frequency of sky conditions. Therefore, this software can predict more correct calculation about illuminance and amounts of energy-saving of daylight responsive dimming systems.

  • PDF

4면형 아트리움의 높이비와 천창 투과율에 따른 인접 실내공간의 자연채광성능 평가 (Evaluation of the daylight performance of adjacent interior spaces in four-sided atrium according to the height ratio of atrium, and the transmittance of atrium canopy)

  • 유하늬;이주윤;송규동
    • KIEAE Journal
    • /
    • 제10권5호
    • /
    • pp.57-62
    • /
    • 2010
  • Studies on daylighting of buildings have been continuously increased due to the recent escalating oil price and low-carbon strategies in developed countries. Daylighting of buildings not only saves electric energy, but provide the occupants with a comfort visual environment. Atrium spaces are adopted by many modern buildings to improve daylight performance of deep interior spaces. Among the various types of atria, the four-sided type atrium is frequently adopted by library buildings, governmental buildings and office buildings. This study aims to suggest daylighting design data for adjacent occupied spaces by conducting dynamic simulations using Daysim program. Daylight Factor(DF), Daylight Autonomy(DA) and Useful Daylight Illuminance(UDI) levels for 12 measurement points in adjacent occupied spaces were calculated for square-shape four-sided atria with different SAR(Section Aspect Ratio) and different canopy transmittance.

아트리움의 자연채광 성능 예측용 노모그래프 (Daylighting Performance Nomographs for Toplit Atrium)

  • 김정태;정유근
    • KIEAE Journal
    • /
    • 제3권2호
    • /
    • pp.45-50
    • /
    • 2003
  • Today, there are increasing evidences that daylight is essential for health, well-being and productivity. One of the strong contributions, which atria can make to advantages in building, is in allowing the use of daylight. This research is to develop nomographs and to evaluate the daylight performances of toplit atria with louvers. For this purpose, the evaluation models of toplit atria with well indexes of 0.5, 1.0 or 2.0 have been selected through the field surveys of atrium buildings in Seoul area. Also, weather data for solar irradiance and luminous efficacy were gathered from the recently conducted previous researches. The computer simulations were performed under clear sky conditions, using the ADELINE program, and various daylight performances were analyzed by the daylight illumination ratio. Analyzing the simulation results, solar altitude, solar azimuth, and louver angle and louver reflectance were found to be important factors affecting the daylight performance of toplit atria. Using these variables, regression equations have been formulated, and the nomographs, which may predict the daylight performances of toplit atria with louvers, were developed. The developed nomographs were validated through comparing the results of nomograph predictions to the results of scale-model experiments.

광덕트방식 자연채광 시스템의 산광부에 대한 연구 (A study on lighting Diffusion system of Daylight Duct System)

  • 송규열;박경우;류한기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 2부
    • /
    • pp.99-104
    • /
    • 2011
  • Daylighting system is an alternative to the energy crisis and environment change. And it is possible improvement system of Architectural Space Environment. Accordingly, it is very useful system. Because Daylight Duct System of Daylighting System gives high performance for its price, distribution rate is very high. But Daylighting Duct System is hard to accurate control. Accordingly, it is difficult to maintain continuously Daylight Environment in Interior Spaces. Lighting Diffusion System has been developed that it is Applying the principle of Reflector and prism diffuser for maximize the efficiency of lighting of Daylight Duct Systems through this study. And then compare lighting performance of Existing System and new Lighting Diffusion System through producing a mock-up. Thus, this study was carried out for the purpose of verification for excellence. It is that installed Each Daylighting Duct System for performance evaluation in a laboratory of width 4m, length 10m, height 2.5m. And illuminance was measured at noon on winter solstice(December 22) under clean sky. The actual measurement result was in the following. Newly developed lighting Diffusion system was measured maximum illuminance 399, minimum illuminance 221, average illuminance 141. Synthetically, daylight factor, uniformity factor and illuminance distribution were improved more than existing system. As a result, it was confirmed that was improved lighting Environment in Interior Spaces.

  • PDF

오픈데이라이트 컨트롤러 클러스터 성능 분석 및 최적 운영 방안 (Performance Evaluation and Optimal Operation Strategy of OpenDaylight Controller Cluster)

  • 김태홍;서동은;백상헌;김명섭;임창규;박수명
    • 한국통신학회논문지
    • /
    • 제41권12호
    • /
    • pp.1801-1810
    • /
    • 2016
  • 본 논문에서는 최근 많은 관심과 집중을 받고 있는 SDN 분야 오픈 소스 프레임워크인 오픈데이라이트 컨트롤러를 중심으로 컨트롤러 클러스터 구조 및 동작방식에 대하여 분석한다. 오픈데이라이트 컨트롤러 클러스터에서는 컨트롤러 간 데이터 스토어의 동기화를 위하여 분산 샤드 구조 및 샤드 리더 선정을 위한 Raft 알고리즘을 적용하고 있다. 성능 분석에서는 컨트롤러 클러스터 크기, 샤드 역할, 샤드 정책에 따른 CRUD, Routed RPC 지연시간 및 리더 재선정 지연시간 등을 분석함으로써, 오픈데이라이트 컨트롤러 클러스터 운영 시의 최적 운영 방안을 논의한다.

실내 주광조도 간이 예측식을 활용한 담천공 시의 자연 채광 성능 평가 (Application of Simplified Daylight Prediction Method for Daylighting Performance Evaluation on Overcast Sky)

  • 윤갑천;윤수인;김성식;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제34권5호
    • /
    • pp.1-9
    • /
    • 2014
  • Daylight is very useful to control the indoor environment, and can save energy in buildings. So it is necessary to evaluate the daylighting performance of buildings. We proposed a simplified equation that can be used in the early stages of design. And we verified the equation by using the measured illuminance data from the 1/5 scale model. We compared the calculated indoor illuminances and measured illuminance including Daylight Factors of scale model in order to verify the applicability of the simplified equation, and proved the analyzed values are acceptable. When we have a target value of the Daylight Factor, we just have to determine the window area, transmittance of the glazing system, and indoor surface reflectance, then can achieve it with this simplified equation.

도서관 열람공간의 방위 및 루버시스템에 따른 주광성능 평가 (An Evaluation of Daylight Performance in the Reading Room of a Library according to Different Azimuths and Louver Systems)

  • 박주현;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제26권3호
    • /
    • pp.45-51
    • /
    • 2006
  • Recently, various kinds of daylight system are recognized as an important and useful strategy in energy-efficient building designs. However, a large amount of direct sunlight can make many problems. Therefore, it is necessary to control daylighting through louver systems for high quality visual environment. The purpose of this study is to analyze daylighting performance in the reading room of a library according to different azimuths and louver systems. The results evaluated daylight performance based on the RADIANCE lighting software.

소규모 사무실 공간에서 간접조명에 대한 조광제어 시스템효율 (Control Efficiency of a Daylight Dimming System for Indirect Lighting in a Small Office)

  • 김수영;정용호;손장열
    • 한국태양에너지학회 논문집
    • /
    • 제26권3호
    • /
    • pp.33-43
    • /
    • 2006
  • Daylight dimming control system was analyzed for an indirect lighting system in a small office space with a double skin envelope system. Computer simulations were performed for photosensors with three shielding conditions. The photosensors were placed on the center of ceiling, and backwall. Three sky conditions defined by CIE were considered. Overall, control performance was not very excellent for all conditions. Fully-shielded photosensor achieved good control performance for some cases, but partially-shielded and unshielded photosensors failed to achieve target illuminance. The variation in desktop illuminance due to daylight was examined for a variety of daylight conditions. Linear correlation between desktop illuminance and photosensor illuminance was analyzed using ANOVA.

Mock-up 실험을 통한 전통한지와 차양장치의 주광유입 특성 평가 (An Evaluation of Daylight Distribution with Korean Traditional Paper and Roller Shading Systems in the Mock-up model)

  • 이순지;김유신;최안섭
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.85-88
    • /
    • 2008
  • The purpose of this study is to analyze daylight distribution and light characteristics on the Ma-ji and Roller Shade fabric, and to investigate a possibility of using it as a shading system. Using a 1/2 Mock-up model, daylight distribution is analyzed with the Ma-ji and Sun-ji (Korean traditional paper) which have good efficiency and less glare. Ma-ji has the best daylight distribution, so that daylight experiment is conducted with the Ma-ji and Roller Shade fabric. In current office buildings and apartment houses, daylight characteristics of Korean traditional paper windows could be used as preliminary data to develop a window system which makes better daylight performance.

  • PDF