• 제목/요약/키워드: Daylight illuminance

검색결과 91건 처리시간 0.027초

Photopia를 이용한 추적식 디쉬형 집광기의 배광분포 분석 및 자연채광 성능 예측 (A Computational Analysis on Candela Distribution Curves and Performance Prediction of a Fiber Optic Dish Daylighting System by Photopia)

  • 오승진;한현주;전영일;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.104-113
    • /
    • 2012
  • A set of candela distribution curves(CDCs) were generated for a fiber optic dish daylighting system by Photopia under clear sky conditions at different solar altitudes. The candela distribution curves were then exported to Radiance for photometric analysis of a windowless lecture room. Observations were made on the Radiance rendered illuminance images, which provided photo realistic scenes varying with solar altitudes. If no tracking error were assumed, the daylight collection efficiency of the system remained at a constant value of 68.4% during its operation. Higher the solar altitude angle, greater in photometric quantities were observed, which are represented by candela(cd) and total lumens(lm). In all cases considered, however, the angle of light distribution remained fixed reflecting the solar tracking feature of the system. The illuminance uniformity on the workplane lingered around 0.12, which is quite low. This is quite a contrast to its average value of 0.68 of the $2.7m^2$ area directly below the terminal device (diffuser) of the system. The maximum illuminance of 1,340lux was obtained at a solar altitude of 80 degrees.

에너지 절약을 위한 건축물의 자연채광디자인 방법에 관한 연구(I) -주광조도예측을 위한 천공상태의 추정방법 비교- (A Study on the Energy Saving Daylighting Design Methodology in Building(I) -Estimation Techniques of Sky Condition for Predicting Daylight Illuminance-)

  • 김정태
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제3권2호
    • /
    • pp.56-62
    • /
    • 1989
  • 자연채광에 관한 에너지 해석을 하기 위해서는 주광조도를 예측하여야 하며, 주광조도를 예측하기 위해서는 천공상태를 추정할 수 있어야만 한다. 즉, 천공상태의 최저상태나 최소설계기준을 추정할 수 있어야만 자연채광에 의한 에너지 절약을 해석할 수가 있다. 천공상태를 추정하는데에는 CIE에서 개발한 정적 천공모델이 많이 이용되어 왔다. 그러나 천공은 정적광원이 아니라 시간에 따라 동적으로 변하고 있음으로 자연채광설계에서 에너지의 영향을 평가하기 위해서는 보다 융통성이 있는 천공모델이 요구된다. 따라서 이 논문은 그동안 동적천공을 나타낼 수 있도록 개발된 비표준천공의 추정방법, 동적 천공상태의 추정방법, 주광조도와 천공휘도의 추정방법, 주광의 유용성 평가방법 등을 비교분석함으로써, 앞으로 우리나라 기후상태에 적합한 자연채광용 천공모델을 개발하는데 기초자료화하였다.

  • PDF

채광성능 평가용 시뮬레이션 프로그램의 비교분석 (A Comparative Evaluation of Daylighting Performance Software : Lumen-Micro, Adeline and Lightscape)

  • 김정태;정유근;문기훈
    • 한국태양에너지학회 논문집
    • /
    • 제23권1호
    • /
    • pp.48-56
    • /
    • 2003
  • Three of the leading computer daylighting simulation programs are compared with physical modeling techniques as a means of predicting daylighting performance of interior spaces. Lumen-Micro, Adeline and Lightscape are compared with physical model experiments under clear sky conditions. The comparative evaluations are conducted on analysis of daylight illuminance ratio(%) depending on model types. The estimated average errors are analyzed on 9.4% in Lumen-Micro, 6.3% in Adeline and 3.4% in Lightscape. Therefore, it is proved that three programs are useful for evaluating daylighting performance in our clear sky condition.

천창이 있는 선큰가든의 고반사율 벽면에 의한 심도 공간 채광성능 (Lighting performance of high reflection wall within covered sunken garden)

  • 임홍수;김곤
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.19-26
    • /
    • 2009
  • This study is performed by method for the influx of natural light in underground space. to solve the several negative underground issues make the covered courtyard and high reflected wall toward the adjacent space. for illuminance level test of sunken garden space, the adjacent space size is $15M{\times}9M{\times}12M$ sunken Garden with space to install the ceiling on the size of the companion light performance analysis, and seasonal changes derived by the light of changes in performance. In addition, increase the distance of the wall and the adjacent space and estimate the average at true time P.M12. The resulting data indicate that the road was an average lux DESKTOP RADIANCE of the modeling and analysis was conducted.

  • PDF

Lightscape를 이용한 광선반 창호시스템의 채광성능평가 (Daylighting Performance Evaluation of Lightshelf Window System by Lightscape)

  • 문기훈;김정태
    • KIEAE Journal
    • /
    • 제4권4호
    • /
    • pp.45-52
    • /
    • 2004
  • Simulation of daylighting by computer program is a method to avoid unnecessary efforts in manufacture of its testing models, to reduce its measuring tolerances and be able to provide variations of various weather conditions as well. Many simulation programs on daylighting have been released freely or commercialized for selling, however, a demonstration of their availability and validity as a tool for evaluating daylighting performance is required since each one has its own characteristics. The objectives of this study lie in suggesting an application method of evaluation tools and demonstration of limits and characteristics so as to more easily determine the daylightingperformance in the very initial stages of planning for an arbitrary office space in which windows with daylight access are built. We produced scale model of the general light inducing type side lighting with lightshelfand ceiling, and the luminance (at 78 measuring points) and illuminance (at 84 measuring points) were measured in a clear sky. And a comparison of the measured values and the calculated values from a computer simulation using the Lightscape program was performed.

광센서 조광제어시스템의 시스템 보정에 관한 연구 (A Study on the System Calibration in Daylight Responsive Dimming Systems)

  • 이정은;최안섭;정근영
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.197-201
    • /
    • 2003
  • The purpose of this study is to analyze the slopes of control algorithm and dimming levels based on different inputs and parameters. Different parameters such as photosensor aiming angles, sky types, and seasonal changes were considered. To determine the slopes of control algorithm and dimming levels, photosensor signals and workplan illuminance values were simulated by DayDim program, which is a lighting calculation and analysis tool. A typical small office space was used for simulation and three different sky types in three different seasons were considered. This study shows that differences in dimming levels can occur according to different sky types, if system calibration is conducted in a particular sky type.

  • PDF

자연채광방식의 응용에 따른 시각적 쾌적성에 관한 연구 (A Study on Visual Comfort for Light Control Method of Applied Daylighting)

  • 한상필;한상철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.140-145
    • /
    • 2012
  • The purpose of this study is to understand the change of impression by comparing the uniformity lighting with the compound lighting. In previous study, we proposed a light controlling method to harmonize daylight from a window and artificial lights from a ceiling and obtained the results to support our method. We referred this method as the Adjusted Compound-Lighting Model (AC Model). The model claims that lighting in a room with a side-window are perceived as harmonious when the overall light distribution in the room is well approximated by a compound of lights from the window and the entire ceiling. The experiment is carried out with the scaled-models and mock-up spaces that were supposed to be an office space. One is lit by the uniform lighting and the other by the compound lighting in each experimental space. In order to present varying illuminance distributions, thetwo variables were used in this study. One was the ratio of thelight from the window and ceiling in the standard and evaluation box. The standard box was provided by the ratio of 20% to 40% from the window and 80% to 60% from the ceiling as two lighting ratio patterns [Wu20(=Cu80) and Wu40(=Cu60)]. And the evaluation box was provided by the light ratio of 0% to 40 from the window and 100% to 60% from the ceiling [Wcp0(=Ccp100), Wcp20(=Ccp80) and Wcp40(=Ccp60)]. The other variable was themean illuminance level in both boxes. Two level of mean illuminance (700lx and 300lx) were used in this experiment. Each lighting condition was established at equal horizontal mean illuminance level, held constant near 700lx or 300lx in both boxes. Both of them were similar in the shape of distribution when there were same ratios of lights from the window and the ceiling. Subjects were asked to evaluate the point of difference by semantic differential rating on their overall impression after comparing with two rooms. The results showed that the impressions of compound lighting were more positive score than that of uniformity lighting on the items of 'dim-bright', 'dislike-like', 'artificial-natural' and 'closed-open', and that there was no significant difference in impressions between two spaces on other items.

  • PDF

전기변색 외피시스템 적용 업무공간의 채광 성능 분석 (Daylighting Performance of Office Space Applied with Electrochromic Façade System)

  • 김재향;한승훈
    • 토지주택연구
    • /
    • 제13권1호
    • /
    • pp.131-140
    • /
    • 2022
  • 스마트 윈도우는 건물의 에너지 절감을 실현할 수 있는 신소재 건축 자재이며, 상황에 따라 가시광선 투과율(Visible Light Transmittance), 일사획득계수(Solar Heat Gain Coefficient, g-value)를 자유롭게 조절할 수 있는 특징을 가진다. Electrochromic(EC), Suspended Particle Device(SPD), Polymer Dispersed Liquid Crystal(PDLC) 등이 스마트 윈도우에 해당되며 현재 실용화 단계에 있다. 최근 스마트 윈도우의 VLT 및 g-value 조절 기능을 통해 건축물의 에너지를 절감하는 방법에 대한 연구가 활발하게 진행되고 있으며, 일부 유의미한 결과가 도출되고 있다. 하지만, 건축물의 에너지 절감에 대해서 연구의 영역이 제한되어 있고, 실내 환경에 대한 연구는 다소 부족한 실정이다. 에너지 절감에만 초점을 맞춘 실내 공간은 충분한 쾌적성이 확보되지 않기 때문에 실내 환경에 대한 고려가 요구된다. 따라서 이 연구에서는 사무공간을 기준으로 채광성능(Daylight Performance) 분석이 수행되었다. 세계 각 국의 친환경 건축인증제도인 LEED, BREEAM, CASBEE, G-SEED의 기준을 통해 스마트 윈도우의 VLT 조절에 따른 채광성능 검토가 이루어졌으며, 쾌적한 실내 채광환경을 유지할 수 있는 스마트 윈도우의 VLT 범위에 대한 고찰이 이루어졌다. 분석을 위해 사용된 스마트 윈도우는 VLT 조절 범위가 가장 넓은 EC가 사용되었다. 분석 결과 한국의 친환경 건축인증제도인 G-SEED의 평균주광률을 충족하기 위한 스마트 윈도우의 최소 VLT는 25% 이상으로 나타났으며, 스마트 윈도우의 VLT 조절은 균제도에 유의한 영향을 미치지 않는 것으로 나타났다. 또한, LEED의 실내 최소조도의 기준을 적용할 시 적용되어야 하는 계절 및 향에 대한 스마트 윈도우의 VLT 조절 범위 값이 도출되었다.

자연채광의 응용에 의한 합성조명방식의 시각적 쾌적성에 관한 연구 (A Study on Visual Comfort for Compound Lighting Control Method of Applied Daylighting)

  • 한상필;전용한;한상철
    • 한국태양에너지학회 논문집
    • /
    • 제32권spc3호
    • /
    • pp.199-206
    • /
    • 2012
  • The purpose of this study is to understand the change of impression by comparing the uniformity lighting with the compound lighting. In previous study, we proposed a light controlling method to harmonize daylight from a window and artificial lights from a ceiling and obtained the results to support our method. We referred this method as the Adjusted Compound-Lighting Model (AC Model). The experiment is carried out with the scaled-models and mock-up spaces that were supposed to be an office space. One is lit by the uniform lighting and the other by the compound lighting in each experimental space. In order to present varying illuminance distributions, the two variables were used in this study. Subjects were asked to evaluate the point of difference by semantic differential rating on their overall impression after comparing with two rooms. The results showed that the impressions of compound lighting were more positive score than that of uniformity lighting on the items of 'dim-bright', 'dislike-like', 'artificial-natural' and 'closed-open', and that there was no significant difference in impressions between two spaces on other items.

주거공간의 혼합형 광선반 각도 변화에 따른 채광성능 평가 (Evaluation of Lighting Performance of Mixed Type Light-shelf in Residential Space According to Angular Variations)

  • 채우리;이행우;서장후;김용성
    • 설비공학논문집
    • /
    • 제26권9호
    • /
    • pp.424-433
    • /
    • 2014
  • The purpose of this study is to evaluate the effectiveness in the lighting performance of mixed type light-shelf, by comparing and analyzing the internal light-shelf, external light-shelf, and mixed-type light-shelf. The performance of light-shelf was evaluated according to the angle of light-shelf at summer solstice, winter solstice, vernal equinox, and autumn equinox. The comparative analysis between the internal light-shelf, external light-shelf, and mixed-type light-shelf was carried out using the performance evaluation and analysis method. The result of performance evaluation is shown as follows. The mixed type light-shelf showed the highest lighting performance all at summer solstice, winter solstice, vernal equinox, and autumn equinox, followed by the external light-shelf and the internal light-shelf in the same order. The mixed type light-shelf was the most favorable for bringing daylight to indoors by adjusting the angle of light-shelf, and it also showed the highest lighting performance in terms of uniformity ratio of illumination which indicates the quality of light.