• Title/Summary/Keyword: Daylight illuminance

Search Result 91, Processing Time 0.027 seconds

Analysis on Dimming Control Effect by Algorithm Variation for Direct/Indirect Lighting in a Small Office (알고리듬 변화에 따른 직/간접 조명시스템에 대한 디밍제어 효과분석)

  • Kim, Soo-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.36-48
    • /
    • 2008
  • This study examines the influence of control algorithms on dimming performance to determine appropriate control setting when direct/indirect lighting is controlled by a daylight dimming system. Computer simulation were performed for a small office with double skin envelope under various daylight conditions. A retractable fabric shading and Venetian blind were applied for internal and external envelopes under three CIE standard sky conditions. Unshielded and partially-shielded photosensors were used, and three control algorithms were applied for the sensors. In general, dimming level was too excessive due to the direct impact of light from lighting fixture to the photosensor. Providing insufficient lighting output, the unshielded photosensor completely failed to secure required illuminance under any daylight condition. When a partially-shielded photosensor was applied under clear sky, three setting points functioned effectively. Less sensitivity for the partially-shielded photosensor was effective to control the dimming system optimally with reasonable energy saving. However, the daylight dimming control system for direct/indirect lighting does not appear to be energy effective when photosensors without enough shielded area is installed on ceiling where light from fixtures reaches directly.

Preliminary Field Test on Daylighting Performance of Perpendicular Light Pipe System (수직형 라이트파이프의 채광성능에 관한 예비평가)

  • Shin, Hae Mi;Park, Hoon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.53-60
    • /
    • 2008
  • The daylighting affects on the human biological cycles and physiological alterations. Daylighting is also an important element in visual comfort and it sometimes influences the quality of vision. Therefore the absence of natural light during the day brings contradictory result. To solve the problems of natural light lack and provide sufficient daylight in interior spaces, it might be necessary to apply some daylighting systems. One of these systems, light pipe system, which is simple, cheep and easily constructed, is very useful to apply for small buildings. The light pipe is simple means of directing daylighting (diffuse and direct lighting)into interior space. In order to application of light pipe system in Korea, it is necessary to optical data of light pipe system. This study aims to evaluate preliminary experiment of the daylighting environment of light pipe system. Light pipe system, that aspect ratio is 1:2(diameter and length), was installed in a windowless mock-up with $27m^2$. The mock-up model was constructed as a prototype of Korean office surface. Illuminance was measured with a Topcon IM-5 Luxmeter to evaluate the distribution of the illuminance on a floor. The indoor and outdoor illuminance and the internal/external illuminance ratio are compared to discuss with in the graphs. Luminance was measured with Radiant imaging Promertric 1400 that is digital photometer to evaluate the distribution of luminance on interior surface. The contrast of luminance is discussed with table and graphs.

Development of Nomographs for the Evaluation of Lighting Energy Performance in a Semi-infinite Office Space (중규모 사무공간에서 조명에너지 성능평가를 위한 노모그래프 개발에 관한 연구)

  • Kim, Han-Seong;Ko, Dong-Hwan;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.73-80
    • /
    • 2003
  • The purpose of this study was to analyze daylighting performance in a semi-infinite size office space for lighting energy conservation. DOE2.1E was used for simulations for the model space of $12\times12\times2.6m$. Nomographs were developed which could simulate work plane illuminance, glare index, energy consumption rate and energy reduction rate for daylighting design. Major results of simulations are as follows ; 1) When blinds facing south were installed, 43% of workplane illuminance diminished, but the flare index didn't exceed the recommended max-glare value. 2) In a semi-infinite office space facing south. energy consumption rate in the case space of 500 lux workplane illuminance is larger then case space of 300 lux workplane illuminance. Therefore, energy reduction rate is increased when the semi-infinite office faces south and naintains 300 lux workplane illuminance level.

Daylighting Performance of Lightpipe under Different Sky Conditions (천공상태에 따른 수직형 광파이프 시스템의 채광성능 평가)

  • Kong, Hyo Joo;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.3
    • /
    • pp.101-106
    • /
    • 2008
  • The use of daylighting has been increased recently due to energy and visual comfort. The aims of interior daylighting are to adequately illuminate visual tasks, to create an attractive visual environment, and to save electrical energy. Lightpipe can improve the distribution of light to interior spaces. This study aims to evaluate the comparative daylighting performance of lightpipe under different sky conditions with mock-up model, sized $6m{\times}6m{\times}4m$ ($w{\times}d{\times}h$). For the purpose, perpendicular lightpipe system was designed as 650 diameter, with an aspect ratio of 2. Totally 49 measuring points of and two of outdoor illuminance on the horizontal plane were monitored from 09:00 to 18:30 on April 29 and May 15 2008. Agilent data logger and photometric sensor were used. Light factor were used to analyse daylight performance under different sky condition. Under overcast sky condition and clear sky condition, the lightpipe system is suitable for KS recommendation level of illuminance.

A Study on the Prediction of Exterior Daylight Illuminance under Three Dimensional Hemisphere (3차원 천구에서의 외부일광조도 예측에 관한 연구)

  • Ku, H.D.;Kim, K.S.;Na, K.T.;Song, I.C.
    • Solar Energy
    • /
    • v.19 no.1
    • /
    • pp.47-57
    • /
    • 1999
  • A building and the solar are related to the privilege of solar benefit. To make step, it is required to build up an object, chase the position of object and the solar, find the shadow occurrence. On the subject of direct illuminance, an intensive emission of irradiation is proposed to directly project to the benefit area. Simultaneously on the indirect illuminance, the integration of a finite element incident to the benefit area can be multiplied by the hemisphere luminance. A caution should be paid to eliminate the occupation area of the object around on the hemispherical sky, which can help run more accurate prediction.

  • PDF

Scale Model Experiment on Daylighting of Differentiated Glazing System (축소모형을 이용한 분할형 유리 투과체 창호시스템의 채광성능실험)

  • Jeong, In Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.4
    • /
    • pp.61-68
    • /
    • 2004
  • Daylight is a critical factor in architecture, as it helps enhance the working efficiency and pleasantness of the people working inside, in addition to reduce the power consumption in heating and cooling and make the interior space brighter. There are many kinds of glazing and daylighting systems. At present, research and efforts for their development are carried out, alongside quantitative evaluation. This study aims to present basic materials to be used to design proper glazing and daylighting systems in architecture based on a quantitative evaluation by scale models of existing office buildings. The result of the study can be summarized as follows. 1)As a result of the experiment, it appeared that the ratio of the interior illumination (i.e. at the working table, ceiling and wall) against the outdoor illumination increases at a constant rate, as the transmittance of the glazing goes up. 2) It was found that the SIR(Sunlight Illuminance Ratio) of a separated window system goes up by 20-50% at the rear part than in the case of an ordinary window system.

A study of Illumination on Exhibitory Space by Natural Light Through the Inducing Space (자연채광 유도공간에의한 전시공간내 채광에 관한 연구)

  • Hwang, Kyu-Seon;Tae, Won-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.1
    • /
    • pp.48-55
    • /
    • 2012
  • In recent years, it clearly shows the tendency toward the utilization of daylight in many exhibitory buildings such as museum since the expectation of visitors for whom high illuminance levels are preferable to perceive the details of the works of art. Shading devices and special glazings are often used as the tool to control the amount of light and heat which should be avoided for the presentation of high-light sensitive art works such as paintings. Another way of controling the light is to provide the space for inducing and attenuating light in the exhibitory building. This study aims to investigate the illuminance on the exhibitory space when the space for inducing and attenuating light is applied. Interaction between the daylight and the space was simulated by Lumen Micro program with variation of the size of the exhibitory space, the length of inner wall, surface reflectivity, area of windows to obtain the illumination of the wall surface. This study shows that those variables affect the illumination on the wall surfaces. By comparing the results with suggestive illumination of KS and ICOM, available wall for display on natural lighting are suggested for the seasons and time.

Performance Evaluation of Applied to Natural Light and Artificial Lighting Hybrid Dimming Control System (자연조명과 인공조명이 병행 적용된 하이브리드 디밍제어시스템의 성능평가)

  • Sung, Tae-Kyung;Lee, Chung-Sik;Kim, Byung-Chul;Joung, Che-Bong;Kang, Seung-Hoo
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.66-74
    • /
    • 2014
  • In this paper, the performance of Hybrid Dimming control system for Daylighting system is evaluated by accredited tests. The system controls the balance of illuminance of daylight between daylight system and LED light system. It makes the normal illuminance of interior without the effects of weather by controlling the LED depending on the brightness of outside. For the tests, 6 diffusers($600{\times}300mm$) were installed in lighting area($36m^2$) and normal operation of the system sensors were tested about the interference of sunlight. The results of the examinations were satisfied with the criteria of accredited tests. Further research is the verification of energy saving effect by comparing the Hybrid Dimming control system to current artificial light system.

Study on Daylight Inflow Environment Consequent on the Length of Light Shelf and Slat Angle Control for Fostering Visual Environment in Patient Rooms of Hospital - By Dynamic Daylight Simulation Using Weather Data - (종합병원 병실 내 시환경 조성을 위한 광선반 길이 및 Slat각 제어에 따른 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Cho, Ju Young;Lee, Ki Ho;Lee, Hyo Won
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.113-121
    • /
    • 2012
  • A hospital is the most important infra-facility of the places which take care of people's body in social environment. There exist several environmental factors in the ways to heal the human body in hospital ward, but this study tried to look into the improvable pleasant sickroom environment with focus on light environment among the factors. In other words, this study aims at the research on proper daylight inflow into sickroom space as basic data for understanding the link between healing environment and natural lighting. In the simulation analysis through this research, this study completed the initial simulation using Autodesk Revit 2011 with focus on two types of individual multi-bed room units of the two general hospitals located in Gwangju City. This study made a simulation analysis of The two multi-bed rooms looking to the west using the weather data on Gwangju district, which is the strong point of ECOTECT2011. Conclusively, looking into the analysis of the simulation model in time of attaching the length of in & outside light shelf, the angle controlling of light shelf, the daylight factor and DA were found to show the tendency to decrease in the numerical value due to the decrease in sunlight inflow as the simulation model moved more toward the room from the window in comparison with the existing analysis of multi-bed rooms. Particularly, this study was able to read that the daylight factor and DA were more decreasing to improve at the light shelf than the existing bedrooms; conclusively, this study judges that the natural lighting simulation analysis could be helpful in improving the healing environment as basic data.

Evaluation and Application of Prediction Models for the Daylight Performance of a Light-Pipe System (광파이프 시스템의 채광성능 예측모델의 검증 및 적용)

  • Yun, Geun Young;Shin, Ju Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2010
  • The use of natural light has the potential for improving both the energy efficiency and indoor environmental quality in buildings. A light-pipe system can introduce daylight to spaces that would otherwise not be able to benefit from the advantages of daylight penetration. For the light-pipe system to be widely used in Korea, it is important to quantify its daylighting performance with due consideration regarding the effects imposed by the local climate conditions. This paper presents the evaluation results of existing semi-empirical models to predict daylighting performance of a light-pipe system. The evaluation of the existing models was based on the monitoring data obtained from a underground parking lot in which the light-pipe system was installed. Comparisons were made between the predicted and the monitored data obtained from the study. The results indicated that semi-empirical models which was developed using the experimental data obtained under the Korean climatic conditions had a good prediction performance. We also quantified the effects caused by sky conditions, solar altitudes, room dimensions, and the aspect ratio of a light-pipe system on both the daylighting performance of the light-pipe system and the indoor illuminance distributions of the space using the semi-empirical model. Finally, this paper provides the design guideline of the light-pipe system for its application to an underground parking lot space.