The study on the Analysis of Useful Daylight Illuminance in rural standard house model - By Dynamic Daylight Simulation Using Weather Data - (농어촌주택 표준설계의 유용조도 분석에 관한 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Yun, Young Il;Song, Jeong Suk;Lee, Hyo Won
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.47-55
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the Rural standard house models design process, because of lack of previous studies on elderly-light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

The Study on the Analysis of Useful Daylight Illuminance in Care Facilities - By Dynamic Daylight Simulation Using Weather Data - (요양시설의 유용조도 분석에 관한 연구 -기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로-)

  • Yun, Youngil;Cho, Juyoung;Lee, Hyowon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.1
    • /
    • pp.33-40
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the care facility design process, because of lack of previous studies on elderly- light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

Revisiting Prediction Tools for Daylight Adequacy and Its Potential Improvement

  • Kim, Dong Hyun
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.35-44
    • /
    • 2017
  • Purpose: This study questioned the efficiency of daylight factor as a daylight adequacy and investigated a method of how to complement its weakness by considering a direct sunlight component under a clear sky condition. Method: The Snowdon visitor centre cafe was chosen as a case study building and various techniques such as BRE formula, BRE sky protractor, Pilkington dot diagram and mock-upscale model under the artificial sky simulator were used to analyse and compare daylight factor values. An analysis of direct sunlight component under the clear sky condition was carried out by Climate Consultant 5.5, sun path diagram, and the artificial sky simulator. Result: The result of daylight factor analysis differed by the adopted techniques and it was also contradictory to the results on a direct sunlight penetration. The result not only showed the limitation of daylight factor as a metric but also suggested an improvement by combining it with direct sunlight analysis. The techniques used in this study had a merit of being applied in the early design stage and thus be beneficial to many design professions in order for early daylight performance analysis.

Application of the Daylight Factor Formula with the Modified Split Flux (Modified Split Flux를 이용한 주광률 계산식 적용에 관한 연구)

  • Yun, Su-In;Yun, Gyeong;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.39-47
    • /
    • 2014
  • Daylighting has a great effect on people inside the room. It is also closely related to the lighting energy consumption. Daylight factor(DF) is a very important index for evaluation of the daylighting in overcast sky. The objective of this study is to verify the suitability of the Tregenza's Modified Split Flux formula for the calculation of the daylight factor. We compared the daylight factors calculated by two methods; one by a measurement with 1/5 scale model and the other by the Daysim program. We used variables for verification as window wall ratios(WWR) and angles of the sky visible. As a result, daylight factor calculated by Modified Split Flux is similar to the measurement when more daylight enters the inside. And error is significantly increased when the angle of the sky visible is $50^{\circ}$.

Evaluation of the daylight performance of adjacent interior spaces in four-sided atrium according to the height ratio of atrium, and the transmittance of atrium canopy (4면형 아트리움의 높이비와 천창 투과율에 따른 인접 실내공간의 자연채광성능 평가)

  • Yu, Ha-Nui;Lee, Ju-Yun;Song, Kyoo-Dong
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.57-62
    • /
    • 2010
  • Studies on daylighting of buildings have been continuously increased due to the recent escalating oil price and low-carbon strategies in developed countries. Daylighting of buildings not only saves electric energy, but provide the occupants with a comfort visual environment. Atrium spaces are adopted by many modern buildings to improve daylight performance of deep interior spaces. Among the various types of atria, the four-sided type atrium is frequently adopted by library buildings, governmental buildings and office buildings. This study aims to suggest daylighting design data for adjacent occupied spaces by conducting dynamic simulations using Daysim program. Daylight Factor(DF), Daylight Autonomy(DA) and Useful Daylight Illuminance(UDI) levels for 12 measurement points in adjacent occupied spaces were calculated for square-shape four-sided atria with different SAR(Section Aspect Ratio) and different canopy transmittance.

Design of Daylighting Aperture Using Daylight Factor Method and its Evaluation by Distribution of Sky Component (Daylight Factor Method를 이용한 채광창의 설계와 주광율의 직접조도분에 의한 채광창의 평가)

  • Chee, Chol-Kon;Kwon, Young-Hye
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.210-213
    • /
    • 1988
  • A new and accurate expression to derive a window area is presented with a sequence for daylighting design using Daylight Factor Method process not in its classical point--by-point method but in lumen method as in artificial lighting design process to consider daylight in the early stage of a building design process. Accepting CIE Overcast Sky as the worst state with the lowest sky luminance, a user of a room can have more available daylight in his or her room. In the design process uniformity is checked to ensure reasonably even daylighting by comparing the depth of the room with the computed limiting depth. After these steps the shape and position of window is altered, of which the Sky Component of Daylight Factor under an Overcast Sky, SCo, is investigated and computed in Composite Simpson Multiple Integral so that a building designer or an analyst can choose the best shape and location that satisfies his/her taste and purpose of the room.

  • PDF

Design of Daylighting Aperture Using Daylight Factor Method and its Evaluation by Distribution of Sky Component (Daylight Factor Method를 이용한 채광창의 설계)

  • 지철근;권영혜
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.3 no.1
    • /
    • pp.58-63
    • /
    • 1989
  • 이등분한 실의 주광율(Daylight Factor)의 비를 규제도의 지수로서 Lumen Method와 같이 정하고, 이를 만족하는 실의 깊이를 검토한 후, 설계 평균 주광율을 만족하는 창의 면적을 구하였다. 본 논문에서 제안한 창의 면적 자체가 다른 벽면의 면적 변화에 영향을 주고 있음을 고려하지 않은 종래의 방법을 개선하였다. 이후 주광율 요소 중 가장 지배적인 양인 운천공으로부터 입사하는 성분(SCo: Sky Component from overcast Sky)의 분포를 창의 위치와 형태를 변화시켜 조사, 평가하였다.

  • PDF

Evaluation of Daylighting Performance in Office Building with Detailed Global Illuminance Data of Selected Korean Cities (정밀 전천공조도 데이터를 활용한 국내 주요도시 업무용 건물의 자연채광 활용성능 평가)

  • Choi, Su-Hyun;Shin, Sang-Yong;Seo, Dong-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.37-46
    • /
    • 2016
  • In this study, long-term global illuminance data for 19 selected cities are calculated from modeled solar radiation data, AEER's TMY2. Perez model in Daysim daylight simulation tool is used for the solar radiation to illuminance conversion. And then, daylight availability in an unit office space is evaluated for the 19 cities. For this evaluation, various daylight performance indices are reviewed since static daylight performance index such as daylight factor (DF) and annual average global illuminance value is not suitable for actual performance evaluation in terms of visual comfort and light energy saving of a space. This study evaluated daylighting performance of prototypical office space module by introducing DA (daylight autonomy) and UDI (Useful Daylight Illuminance) index for major cities of Korea. Result shows that there is upto 18% of illuminance level difference with annual average global illuminance data, but if we consider useful daylight in a space the illuminance level difference among the cities are only within 5%. This means that for sustainable building design especially in daylight design, amount of annual global illuminance is not important factor even in cloudy cities. Daylight design and daylight harvesting system would return similar energy saving impact regardless of building location.

Study on Daylight Inflow Environment Consequent on the Length of Light Shelf and Slat Angle Control for Fostering Visual Environment in Patient Rooms of Hospital - By Dynamic Daylight Simulation Using Weather Data - (종합병원 병실 내 시환경 조성을 위한 광선반 길이 및 Slat각 제어에 따른 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Cho, Ju Young;Lee, Ki Ho;Lee, Hyo Won
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.113-121
    • /
    • 2012
  • A hospital is the most important infra-facility of the places which take care of people's body in social environment. There exist several environmental factors in the ways to heal the human body in hospital ward, but this study tried to look into the improvable pleasant sickroom environment with focus on light environment among the factors. In other words, this study aims at the research on proper daylight inflow into sickroom space as basic data for understanding the link between healing environment and natural lighting. In the simulation analysis through this research, this study completed the initial simulation using Autodesk Revit 2011 with focus on two types of individual multi-bed room units of the two general hospitals located in Gwangju City. This study made a simulation analysis of The two multi-bed rooms looking to the west using the weather data on Gwangju district, which is the strong point of ECOTECT2011. Conclusively, looking into the analysis of the simulation model in time of attaching the length of in & outside light shelf, the angle controlling of light shelf, the daylight factor and DA were found to show the tendency to decrease in the numerical value due to the decrease in sunlight inflow as the simulation model moved more toward the room from the window in comparison with the existing analysis of multi-bed rooms. Particularly, this study was able to read that the daylight factor and DA were more decreasing to improve at the light shelf than the existing bedrooms; conclusively, this study judges that the natural lighting simulation analysis could be helpful in improving the healing environment as basic data.

A study on lighting Diffusion system of Daylight Duct System (광덕트방식 자연채광 시스템의 산광부에 대한 연구)

  • Song, Kyu-Ryol;Park, Gyeong-Woo;Ryu, Han-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.99-104
    • /
    • 2011
  • Daylighting system is an alternative to the energy crisis and environment change. And it is possible improvement system of Architectural Space Environment. Accordingly, it is very useful system. Because Daylight Duct System of Daylighting System gives high performance for its price, distribution rate is very high. But Daylighting Duct System is hard to accurate control. Accordingly, it is difficult to maintain continuously Daylight Environment in Interior Spaces. Lighting Diffusion System has been developed that it is Applying the principle of Reflector and prism diffuser for maximize the efficiency of lighting of Daylight Duct Systems through this study. And then compare lighting performance of Existing System and new Lighting Diffusion System through producing a mock-up. Thus, this study was carried out for the purpose of verification for excellence. It is that installed Each Daylighting Duct System for performance evaluation in a laboratory of width 4m, length 10m, height 2.5m. And illuminance was measured at noon on winter solstice(December 22) under clean sky. The actual measurement result was in the following. Newly developed lighting Diffusion system was measured maximum illuminance 399, minimum illuminance 221, average illuminance 141. Synthetically, daylight factor, uniformity factor and illuminance distribution were improved more than existing system. As a result, it was confirmed that was improved lighting Environment in Interior Spaces.

  • PDF