A Study on Hydrogeological Characteristics of Deep-Depth Rock Aquifer by Rock Types in Korea (국내 암종별 고심도 암반대수층 수리지질특성 연구)
-
- Tunnel and Underground Space
- /
- v.34 no.4
- /
- pp.374-392
- /
- 2024
In order to successfully select a site for deep geological disposal of high-level radioactive waste, it is important to perform the stepwise approach along with the systematic selection and survey of evaluation parameters of geological environmental characteristics suitable for the domestic geological environment. In this study, we evaluated the characteristics of hydraulic conductivity, which is considered the most important evaluation parameter in the field of hydrogeology, targeting a deep-depth rock aquifer where actual disposal facilities are expected to be located. In particular, for the first time in Korea, we obtained in-situ pressure-flow data by directly conducting hydraulic tests in boreholes at depths ranging from 500 m to 750 m in various rock types distributed in Korea (granite/volcanic rock/gneiss/mudstone). And we derived hydraulic conductivity values by rock types and depth using verified analytical methods. For this purpose, precision hydraulic testing equipment developed in-house through this study was used, and detailed investigation procedures based on standard test methods were applied to field tests. As a result of the analysis, the average hydraulic conductivity value was found to be in the range of 10-9 m/s in all granite/volcanic rock/gneiss areas. In the mudstone area, an average hydraulic conductivity value of 10-11 m/s was derived, which was about 100 times (2 orders of magnitude) lower than that of the fractured rock aquifers. Moreover, permeability tended to slightly decrease with depth in fractured rock aquifers (granite and volcanic rock areas) containing many rock fractures. The gneiss area tended to have large local differences in permeability according to the composition of the stratum and the development of fracture zones rather than depth. In mudstone areas with weak fracture development, there was no significant variation in rock permeability according to depth. The hydraulic conductivity results by various rock types and depth presented in this study are expected to be utilized in building a foundational database for the site selection, design, and construction of disposal facilities in Korea.
The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m
Objectives: This study attempts to analyze the length of hospital stay and expenses of frequent disease admitted in a Vaterans Hospital. Methods: Data was collected from January 1, 2001 to December 31, 2003 from the Claim records of 9,640 patients in a Vaterans Hospital. Results: The results were as follows: 1. In age & sex distribution, there was male 70.9%, female 29.1%, and 35.8% of them is 70 age group. Frequency by insurance program was Health insurance 78.1%, Medical aid 14.2%, no insurance 4.1%, others 3.6%. Distribution of each department was internal medicine 28.3%, orthopedic surgery 21.3%, surgery 16.6%, neurosurgey 7.1%, pediatrics 5.9%. Also, in the veterans group, male to female patient ratio was 99.3% male to 0.7% female, them over 70 years old was 51.6%, and them which live in daejeon was 43.5%. 2. In frequency of disease, there was gastroenteritis 4.8%, pneumonia 3.8%, cartaract 3.7%, cerebral infarct 3.2%, hyperplasia of prostate 3.0%. In frequency of korean standard classification of diseases, there was injury and poisoning and certain other consequences of external causes 17.1%, diseases of digestive system 16.1%, diseases of musculoskeletal system and connective tissue 13.9%, diseases of respiratory system 9.4%, diseases of genitourinary system 8.6%. Also, in veterans group, frequency of them was diseases of musculoskeletal system and connective tissue 19.4%, diseases of digestive system 16.8%, injury and poisoning and certain other consequences of external causes 15.7%, diseases of genitourinary system 9.7%, diseases of circuatory system 8.2%. 3. Average length of hospital stay was 29.0 days for total patients, 51.8 days for the veterans group, 15.7 days for the non-veterans one. Average total expenses was 3,669,579 won, the veterans group 7,263,877 won, the non-veterans one 1,560,333 won. The ratio of insurer to insuree was 55.2 : 44.8, the ratio of amount paid by patient in the veterans group 61.7%, in the non-veterans one 33.0%. 4. In items of medical expenses, fee for hospital accommodation was 34.7%, fee for medication 13.2%(injection 7.8%, drug 5.4%), fee for service 48.6%(physical therapy 26.3%, operation 9.7%, laboratory examination 5.2%, radiological examination 3.1%, etc), others 3.4%. In them for the veterans group, fee for physical therapy was 35.3%, fee for hospital accommodation 35.2%, fee for injection 6.2%, fee for operation 5.9%, for the non-veterans one, fee for hospital accommodation 35.7%, fee for operation 16.4%, fee for injection 11.4%, fee for laboratory examination 8.3%. 5. In the comparison of the frequency by Korean standard classification of diseases and distance between the hospital and home, the region under 21.5Km was more frequent in symptoms, signs an abnormal clinical and laboratory findings 56.0%, injury and poisoning and certain other consequences of external causes 55.6%, diseases of the eye and adnexa 52.9%, the one over 21.5Km was more frequent in neoplasms 57.4%, diseases of musculoskeletal system and connective tissue 55.9%, diseases of genitourinary system 53.5%.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
This study investigated Chinese Laws on the kind of urban green spaces and the legal requirements for the green spaces of urban habitat and analyzed the specificities of them intending to provide basic data to suggest bringing in or not the relevant Chinese Laws to Korea. This study can be summarized as follows: First, the concept of Chinese urban green spaces(g.s.) classified by 5 kinds(park g.s., production g.s., protection g.s., attachment g.s., the others g.s.) placed the park and green spaces in the same category unlike the Korean urban green spaces that only distinguishes between park and green spaces. The Chinese Urban Park is classified by 4 kinds(composite park, community park, special park, linear park) at the 'Standard for urban green spaces classification' which is below in rank of the legal system. Second, in case of calculation for green spaces ratio of urban green spaces in China, the green rooftop landscaping area should not be included as a green spaces area except the rooftop of a basement or semi basement building to which residents have easy access. The green spaces requirements and compulsory secure ratio by 3 habitat kinds(habitat, small habit, minimum habitat) of when to act as a residential plan is regulated. Third, the green spaces system is obligated to establish at habitat green spaces plan and is specified to conserve and improve existing trees and green spaces. The green spaces ratio on reconstruction for old habitat is relaxed to be lower than for new habitat and a gradient of green spaces is peculiarly clarified. The details and requirements for establishment and the minimum area intending for each classes of the central green spaces(habitat park, children park, minimum habitat's green spaces) are regulated. Especially at a garden style of minimum habitat's green spaces, intervals between the south and north houses and a compulsory security for green spaces area classifying into two groups(closing type green spaces and open type green spaces) by a middle-rise or high-rise building are clarified. System of calculation for green spaces area is presented at a special regulation. Fourth, a general index(area/person) of public green spaces within habitat to achieve by 3 habitat kinds is determined, in this case, the index on reconstruction for a deterioration zone can be relaxed to be lower to the extent of a specified quantity. A location and scale, minimum width and minimum area per place of public green spaces are regulated. A space plot principle including adjacent to a road, greening area ratio against total area, security of open space and the shadow line boundary of sunshine are also regulated to intend for public green spaces. Fifth, the minimum horizontal distance between the underground cables and the surrounding greening trees are regulated as the considerable items for green spaces when setting up the underground cables. The principle to establish green spaces within public service facilities is regulated according to the kind of service contents. It shall be examined in order to import or not the special regulations that only exist in Chinese Laws but not in Korean Laws. The result of this study will contribute to gain the domestic landscape architect's' sympathy of the research related to Chinese urban green spaces laws requiring immediate attention and will be a good chance to advance into the internationalization of Korean Landscape Architectural Laws.
Objectives. This study was conducted to evaluate the association between upper extremity musculoskeletal symptoms and Rapid Upper Limb Assessment(RULA) in vehicle assembly line workers. The goal of this study is to show the feasibility of RULA as a checklist for work related musculoskeletal symptoms (WMSDs) in Korean workers. Methods. The total number of 199 people from the department of assembly and 115 people from the department of Quality Control(QC) in automotive plant were subjects for this cross sectional study. A standard symptom questionnaire survey has been used for the individual characteristics, work history, musculosketal symptoms and non-occupational covariates. The data were obtained by applying one-on-one interview for the all subjects. RULA has been applied for ergonomic work posture analysis and the primary ergonomic risk sure was computed by RULA method. Association between upper extremity musculoskeletal symptoms and RULA were assessed by multiple logistic regression analysis. Results. A total of 314 workers was examined. The prevalence of musculoskeletal symptoms by NIOSH case definition was 62.4%. The distribution of musculoskeletal symptoms by the part of the body turned out to be following; back:41.4%, neck: 32.8%, shoulder: 26.4%, arm: 10.5% and hand:29.3%. The relationship of the individual RULA scores were statistically significant for the prevalence of musculoskeletal symptoms. As the result of the multiple logistic regressioin analysis, grand final score (OR=2.250 95% CI: 1.402-3.612) was associated with musculoskeletal symptoms in any part of the body.; upper arm score(OR=1.786 95% CI: 1.036-3.079) and posture score A(OR=1.634 95% CI: 1.016-2.626) in neck; muscel use score(OR=3.076 95% CI:1.782-5.310) and posture score A(OR=1.798 95% CI: 1.072-3.017) in shoulder; upper arm score(OR=1.715 95% CI: 1.083-2.715) and muscel use score(OR=2.057 95% CI:1.303-3.248) in neck & shoulder; muscle use score(OR=10.662 95% CI: 3.180-35.742) in arm; writst/wist score(OR=2.068 95% CI: 1.130-3.786) and muscle use score(OR=2.215 95% CI: 1.284-3.819) in hand & wrist.; muscle use score of trunk (OR=2.601 95% CI: 1.147-5.901) in back. Conclusions. Musculoskeletal symptoms of the extremities were strongly associated with individual RULA body score. These results show that RULA can be used as a useful assessment tool for the evaluation of musculoskeletal loading which is known to contribute to work-related musculoskeletal disorders. RULA also can be used as a screening tool or incorporated into a wider ergonomic assessment of epidemiological, physical, mental, environmental and organizational factors. As shown in this study, complement of the analysis system for the other risk factors and characterizing between the upper limb and back part will be needed for future work.
The parents have much expectation upon the pregnancy and child birth, and in most cases, they expect the healthy parturient child. However, we can be placed on the high-risk conditions which have the physical, social and immature infant, due to the unexpected results, among the new-born. Accordingly, these high-risk newborn and premature infants will be mostly in NICU, which the concentrated medical treatment can be given, upon their conditions. After their birth and during these periods, they will be divided from the parents, and the nurse will accomplish the bringing-up activities which they can take care of the infant, expected by the parents after their birth. The hospitalization of high-risk newborn including these premature infants is the shocking experience to the parents of family, and thus they can feel the fear and uneasiness, and these reactions of parents are troubled in the behavior at the usual days, and cause the disorder and spiritless status, and these results break the supporting ability of parents, and cause the obstruction. Also, the unavoidable division between the parents and the children as like hospitalization of children can make the parents to feel the alienation emotionally, and this causes the results which the pride on the bringing-up ability of baby gets to be lost. These problems can cause the difficulties on the bonding or the parenting in the further days, and can be related to the neglect and abuse of children. Also, it is gradually increased to study and report which the emotional division by the physical division between the mother and the baby obstructs the normal affection course between the parent and the infant. The stress caused by the birth and the hospitalization of high-risk newborn, as like this, is important in the points which it can uncertainly affect the potential energy for the relationship of parent-child who are finally healthy. Accordingly, the significance and purpose of this study are to understand the contents and degree of stress which the parents of high-risk newborn including the immature child can be experienced from the hospitalization of ICU for their new borns, and thus to offer the basic program to the nursing intervention program for these. The subject of this study is the mother of newborn in NICU of 10 General Hospitals located at the 3one of Pusan, Korea from September 1997 to October 1997, and thus makes the subject of 95 person of parents who agreed to take part in the study and it is descriptive study related to the stress of mother having the newborn in NICU. The method is based on the preceding study related to the stress of mother having the experience of child hospitalization and chronic disease child, and then acquires the advice of specialists group as like 5 nursing professors, and then is amended and supplemented. Total number of questions is 43 items and consists of 5 factors as like medical treatment &nursing procedures, disease status & prognosis, role of parents, communication & inter-personal relationships, hospital environment, and is 5 point Likert Scale. The reliability of this study method is very highly shown to be Cronbach α=0.95. The collected data is analysed as Average, Frequency, Standard Deviation, T-test, ANOVA, Pearson Correlation Coefficient, Duncan multifulrange test by use of SPSS /PC (V7.5). The results of this study is summarized as under. 1. Every characteristics of subject is which the party of mother is 28.70age(±7.48) in the average ages, 51% in the high-school graduate, 38.5% in the christianity, total monthly income is 212.55 thousand won(±1.971), 74.5% in the housewife, 72.9% in the parents and children together living and the number of children to be 1.48person(± 0.6) in average, the recognition on the prognosis of baby is 74.0% in 'Don't know', the relationship with the husband after the hospitalization of babyis 37.3% in 'More Intimate', the relationship with the family of husband to be 48% in 'No-change', and the degree which is consulted with the husband about the baby is 55% in 'very frequently' and the visiting number per week is 4.59(±1.63) in average and the accompanying person in the time of visiting is which the number of husband is 56.3% and thus is the highest. The characteristics of baby is which the age is 21.88days(±16.47) after the birth in average, the sex to be 50 person in the female 52.1% and the order of birth to be 54.2% in the first chid, and the weight in the birth to be 2770gm(±610) and the height in the birth to be 46.26cm(±7.62) in aver age. The medical diagnosis is 37.5% in the premature infant, the career of hospitalization is 96.9% in 'None', and the operation plan is 90.6% in 'None' and the execution of operation is 88% in 'None' and the nursing of incubator is 55.2% in 'Yes', and the method of feeding is 50.5% in 'Oral' and the contents of feeding is 46.9% in the 'Milk'. 2. The total stress degree of subject is almost highly shown to be as 3.36(±0.86). If it is compared upon each cause, 'stress on disease status & prognosis' is highest 3.79(±1.28), and it is in the order of 'stress on medical treatment & nursing procedures' 3.70(±0.93), 'stress on hospital environment' 3.14(±0.86), 'stress on role of parents' 3.18(±0.92) and 'stress on communication & inter personal relationship' 2.62(± 0.77) 3. As the results of checking the notworthiness of stress degree upon each variable of subject, the variable showing the noted difference was the birth weight(γ=-0.16, P=0.04), birth height(γ=-0.23, P=0.03), nursing in the incubator(F=8.93, P=0.04), feed method(F=2.94, P=0.04). That is to say, it is shown which the smaller the birth weight is, the higher the stress degree of mother is noteworthily. Also, the smaller the birth height baby is, the higher the stress of mother is. In the incubator, it os shown which the mother whose baby is nursing in the incubator is higher in the stress degree than other mothers. Upon the feeding method of baby, that is to say, TPNis the highest, and it is shown in the order of NPO, Tube feeding, and P.O. feeding. When we review the above-mentioned results, as the status is serious, it is thought which we include the supporting nursing for coping with the stress of parents in the setting-up od nursing plan for the baby in the NICU.
The purpose of this study was to investigate the stress perception, dietary habits, lifestyle and snack intake behaviors of students to help dietary education of high school students in Jeonnam area. The data were collected from high school students in Jeonnam area and 503 questionnaires were used for analysis. The main results of this study are as follows. First, the mean scores of high school students' perception of stress were 2.92 points for male students and 3.07 points for female students, and female students were statistically significantly higher than male students(p<.01). Stress perceptions showed significant differences in school stress(p<.001) and family stress(p<.05) according to gender, and female students gained more stressed than male students. Second, the dietary habits and lifestyle characteristics of high school students by gender showed significant difference between male students and female students at the one meal time(p<.001), the amount of meal(p<.05), the tendency of eating habits(p<.001), the salty taste of food(p<.05), the exercise frequency per week(p<.001) and the exercise time per day(p<.001), respectively. One meal time was shorter for male students than for female students, and the amount of meals was more suitable amount for female students than male students. Also, male students ate more regularly than female students and female students preferred more stimulating foods than male students. Male students ate slightly bland salty taste, and female students ate standard salty taste. The exercise frequency per week and the exercise time per day were more in male students than in female students. Third, the snack intake characteristics of high school students by gender showed significantly different between male students and female students at the cost of snack per day(p<.01), the time to eat snacks(p<.01) and the favorite snacks(p<.001), respectively. The cost of snack per day was higher for female students than for male students in case of less than 4,000 won. The time for eating snack showed that 'Irregularly' was high for male students and 'In the evening after lunch' was high for female students. The favorite snacks were cookies, candies and chocolates for male and female students. Forth, the dietary habits and lifestyle characteristics of high school students by stress level showed significantly different at the frequency of daily meals(p<.05), the tendency of eating habits(p<.01) and the salty taste of food(p<.05), respectively. The frequency of daily meals was more than four times in case of the 'High stress' and 'Low stress' groups. The tendency of eating habit was low in regular meal rate in 'High stress' group. Fifth, the snack intake characteristics of high school students by stress level showed significantly different in the frequency of snacks per day(p<.05) and the favorite taste of snacks(p<.05). In case of the frequency of daily snack intake, 'More than 4 times' was highest in 'High stress' group and 'Low stress' group. The favorite taste of snacks showed that the spicy taste was highest in the 'High stress' group and the 'Low stress' group.
With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.