• 제목/요약/키워드: Data measuring device

검색결과 401건 처리시간 0.027초

압전효과를 이용한 압인방식의 휴대용 피부탄력 측정장치 (A Portable Skin Elasticity Measuring Device Based on Indentation Method Using Piezoelectric Effect)

  • 박준영;김명남
    • 한국멀티미디어학회논문지
    • /
    • 제25권9호
    • /
    • pp.1307-1315
    • /
    • 2022
  • In this paper, we proposed and developed a new portable skin elasticity measuring device based on the indentation method using piezoelectric effect. The proposed device is designed to minimize the uncertainty caused by the layer structure of the skin when measuring the elasticity of the skin. And, we developed a piezoelectric-based thin-film pressure sensor that can measure quantitatively and quickly during repeated measurement as a device sensor. To confirm the effectiveness of the proposed measuring device, it was compared with the experimental results of the conventional measuring devices under the same experimental conditions, and statistical correlation analysis was performed between the experimental data of the proposed measuring device and the experimental data of the conventional measuring devices. As a result of the correlation analysis, it was confirmed that the proposed measuring device had a high correlation with the conventional measuring devices. Therefore, it was confirmed that the proposed skin elasticity measuring device was effective.

항타 시공 작업자를 위한 비접촉식 관입량 측정기 개발 (Development of Non-Contact Penetration Measuring Device for Pile Driving Workers)

  • 김재경;공용구;최경희;조민욱;김승연;김민정;이준협;박채원
    • 한국안전학회지
    • /
    • 제35권3호
    • /
    • pp.58-63
    • /
    • 2020
  • At the construction site of the driving site, the pile rebound and penetration measurements are performed manually to determine the end point of the driving operation, thereby causing the measurer to be exposed to a death accident. In this study, in order to eliminate the risk of this work, a non-contact penetration measuring device was developed and usability evaluation was conducted. The penetration measuring device is manufactured based on the ultrasonic sensor, and can be combined with the pile to deliver the data in real time, and the delivered data can be output in real time on the portable PC and the final penetration can be calculated. Usability evaluation on the device was conducted by comparison with manual work. Usability evaluation was largely evaluated on measured values, subjective comfort, and body parts comfort. The result of the measured value tended to overestimate the value measured manually by the measuring device, which is similar to the previous research. In terms of subjective comfort and body part comfort, overall satisfaction was higher than the manual method when using the measuring device. Taken together, these results indicate that it is possible to use the rudder measuring device in place of manual work in the construction site, and it is judged that the worker's comfort is greatly increased by using the measuring machine. The results of this study suggest that the use of non-contact measuring device in the field can be used as basic data to support them.

열간압연용 롤 정밀 측정시스템 개발 (Development of Precise Measuring System for Hot Strip Mill's Rolls)

  • 이성진;이영진
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.614-618
    • /
    • 2002
  • In hot strip mills, Portable Roll Scanner (the portable roll surface temperature and profile measuring device) can be used to calibrate on-line Process models for strip crown and flatness by measuring the thermal expansion and wear profile of the rolls. And the surface temperature measurement can be used to optimize the roll cooling system. Portable Roll Scanner consists of the measuring device, which has two contact inductive distance transducers for roll profile measurement and one infrared Pyrometer for surface temperature measurement, and computer-based controller that is equipped with the measuring device. By the wireless data communication, the data is transferred to the memory of notebook for further analysis. After roll extraction from mills, Portable Roll Scanner measure the roll profile and surface temperature simultaneously along the work roll face and display the results in the TFT color monitor of notebook. Portable Roll Scanner is useful at mill-side and roll grinding shop.

  • PDF

디지털 원추관입기 개발 (Development of a Digital Cone Index Measuring Device)

  • 이규승;이동훈;조용진;정선옥;박원엽;노광모;장영창
    • Journal of Biosystems Engineering
    • /
    • 제35권6호
    • /
    • pp.387-392
    • /
    • 2010
  • This study was performed to design and to construct a digital soil cone index(CI) measuring device replacing conventional analog type devices. The device developed in the study consisted of a load cell, a rotary encoder and a motor with a decelerator as its main parts. The cone speed was controlled lower than 3.0 m/s which keeps the standard suggested by the ASABE S313.3 specification. The experiment was conducted in a soil bin system as well as in various fields. The CI data measured by the developed device were compared with those by an existing measurement device(SC900, Spectrum, USA). Based on the experiments at various field conditions, the CI measuring characteristic of the device was quite similar to that of the conventional device within a acceptable $R^2$ range of more than 0.5(mean=0.76). It was concluded that the digital cone index measuring device was an effective and comprehensive sensor for measuring soil strength.

복소유전률 측정장치의 연구개발 - 컴퓨터제어 복소유전률 측정장치 - (A study on the computer-controlled measuring device of complex dielectric constant)

  • 남징락;엄상오;강대하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1206-1208
    • /
    • 1993
  • This paper is to study and realize a measuring device for complex dielectric constants. The device is consisted in order of interface unit, external RAM, programmable counter, D/A converter, measuring circuit, Sample & Hold circuit, A/D converter and related control circuits. Various excitation waves are digitalized and sent to the 4096 static RAM by personal computer. These data saved in the RAM are converted to analog excitation waves through D/A converter. The frequency of excitation wave is depend on the read-out speed of the RAM according to clock pulses. Such generated waves are applied to dielectrics under test and their responses are sampled and converted to digital data through A/D converter. The computer takes the digital data and calculates finally the complex dielectric constants. The frequencies for Measurement ranges from 0.04 Hz to 10 kHz.

  • PDF

토양 물리성 측정을 위한 디지털 장치 개발(I) - 디지털 전단저항 측정장치 - (Development of a Digital Device for Measuring Soil Physical Properties (I) - Digital Shear Stress Sensor -)

  • 박준걸;이규승;조성찬;이동훈;장영창;노광모
    • Journal of Biosystems Engineering
    • /
    • 제33권6호
    • /
    • pp.416-422
    • /
    • 2008
  • This study was performed to design and construct a digital soil shear stress sensor in order to replace the conventional devices for measuring soil shear property. The developed digital shear stress measuring device can store measured data with GPS position information as a vector format into a computer. Based on the experiments at various field conditions, the measuring characteristic of the device was quite similar to that of a conventional device, SR-2 that has been a major tool to measure the soil shear property. It was concluded that the digital shear stress measuring device was an effective and comprehensive sensor for measuring soil shear property.

전위차계를 이용한 무인항공기 조종면 변위 측정 장치 구현 및 적용 (Implementation and Application of the Control Surface Deflection Angle measuring device for UAV using Potentiometer)

  • 김지철;최일규;공성철;전동익;이상철;오화석;강민영
    • 항공우주시스템공학회지
    • /
    • 제3권3호
    • /
    • pp.13-16
    • /
    • 2009
  • Aircraft flight control surfaces which are one of the most important elements of safety allow a pilot to adjust and control the aircraft's flight attitude. This paper is described of the control surface deflection angle measuring device. Data analysis through ground test and flight test can provide reliability of this device using the present system. It is also shown that measuring system is capable of detecting failure of control surfaces.

  • PDF

주상변압기 열화진단장치 개발에 관한 연구 (A study on the development of diagnosis device for pole transformer deterior)

  • 이보호;김재철;김영춘;김훈;민경래;김언석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1079-1081
    • /
    • 1998
  • This paper describes the dissipation factor measuring device for insulating oil in operating pole transformer by DSP(digital signal processor). After applying voltage to the sensor which is installed in a transformer, acquire source voltage and current of sensor using FFT techniques, then we could evaluate the dissipation factor of insulating oil. To improve measuring accuracy and processing speed, we use TMS320C31 DSP, FFT and data analysis techniques. Also we suggest deterioration criterion of insulating oil and compared the developed diagnosis device with schering bridge on deteriorated insulating oil. The result of this paper show that the developed measuring device can be used as diagnosis device for the pole transformers.

  • PDF

줄자눈금정밀도 측정장치 개발에 관한 연구 (Development of a measuring device for scale accuracy of measuring tapes)

  • 이종원;김희식;유형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.380-384
    • /
    • 1988
  • An optical device, named "T-MES", to measure the accuracy of printed scale of measuring tapes was developed. It has 11 optical sensors, that are exactly positioned every 100 mm on the 1 m frame. The sensors detect the beginning of the printed part and generate the puleses. The time difference between each signal pulse and the first sensor signal pulse is proportional to the error of printed scale. The measured data are trasmitted through a IEEE-488 interface to a IBM-AT computer and analyzed. The analysis software continuously displays the measured result on the CRT.n the CRT.

  • PDF

형상 검사를 위한 multiple-sensor 측정 시스템의 캘리브레이션 연구 (Calibration off multiple-sensor measuring system for efficient visual inspection)

  • 김승만;손석배;이관행
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.579-582
    • /
    • 2002
  • In acquiring the surface information of a part, two types of measuring machines have been used: contact type and non-contact type. Since each measuring device has the pres and cons, an integrated measuring system is proposed to acquire the optimal point data. In order to implement the integrated measuring system, the relationship of coordinate systems between each measuring device should be established. In this paper, a new datum fixture and a calibration method for the multiple-sensor measuring system are proposed. The datum fixture is designed to interface two machines, a CMM and a laser scanner. The position of the datum fixture is calibrated by the axis information off motorized rotation stage which is used for a part setup.

  • PDF