• Title/Summary/Keyword: Data leakage

Search Result 1,084, Processing Time 0.025 seconds

Verifying a Safe P2P Security Protocol in M2M Communication Environment (M2M 통신환경에서 안전한 P2P 보안 프로토콜 검증)

  • Han, Kun-Hee;Bae, Woo-Sik
    • Journal of Digital Convergence
    • /
    • v.13 no.5
    • /
    • pp.213-218
    • /
    • 2015
  • In parallel with evolving information communication technology, M2M(Machine-to-Machine) industry has implemented multi-functional and high-performance systems, and made great strides with IoT(Internet of Things) and IoE(Internet of Everything). Authentication, confidentiality, anonymity, non-repudiation, data reliability, connectionless and traceability are prerequisites for communication security. Yet, the wireless transmission section in M2M communication is exposed to intruders' attacks. Any security issues attributable to M2M wireless communication protocols may lead to serious concerns including system faults, information leakage and privacy challenges. Therefore, mutual authentication and security are key components of protocol design. Recently, secure communication protocols have been regarded as highly important and explored as such. The present paper draws on hash function, random numbers, secret keys and session keys to design a secure communication protocol. Also, this paper tests the proposed protocol with a formal verification tool, Casper/FDR, to demonstrate its security against a range of intruders' attacks. In brief, the proposed protocol meets the security requirements, addressing the challenges without any problems.

Analysis of the Vulnerability of the IoT by the Scenario (시나리오 분석을 통한 사물인터넷(IoT)의 취약성 분석)

  • Hong, Sunghyuck;Sin, Hyeon-Jun
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.9
    • /
    • pp.1-7
    • /
    • 2017
  • As the network environment develops and speeds up, a lot of smart devices is developed, and a high-speed smart society can be realized while allowing people to interact with objects. As the number of things Internet has surged, a wide range of new security risks and problems have emerged for devices, platforms and operating systems, communications, and connected systems. Due to the physical characteristics of IoT devices, they are smaller in size than conventional systems, and operate with low power, low cost, and relatively low specifications. Therefore, it is difficult to apply the existing security solution used in the existing system. In addition, IoT devices are connected to the network at all times, it is important to ensure that personal privacy exposure, such as eavesdropping, data tampering, privacy breach, information leakage, unauthorized access, Significant security issues can arise, including confidentiality and threats to facilities. In this paper, we investigate cases of security threats and cases of network of IoT, analyze vulnerabilities, and suggest ways to minimize property damage by Internet of things.

Hydrodynamic Properties of Interconnected Fluidized Bed Chemical-Looping Combustors (상호 연결된 유동층 매체 순환식 연소로의 수력학적 특성)

  • Son, Sung Real;Go, Kang Seok;Kim, Sang Done
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.185-192
    • /
    • 2010
  • The chemical-looping combustion(CLC) has advantages of no energy loss for separation of $CO_2$ without $NO_x$ formation. This CLC system consists of oxidation and reduction reactors where metal oxides particles are circulating through these two reactors. In the present study, the reaction kinetic equations of iron oxide oxygen carriers supported on bentonite have been determined by the shrinking core model. Based on the reactivity data, design values of solid circulation rate and solids inventory were determined for the rector. Two types of interconnected fluidized bed systems were designed for CLC application, one system consists of a riser and a bubbling fluidized bed, and the other one has a riser and two bubbling fluidized beds. Solid circulation rates were varied to about $30kg/m^2s$ by aeration into a loop-seal. Solid circulation rate increases with increasing aeration velocity and it increases further with an auxiliary gas flow into the loop-seal. As solid circulation rate is increased, solid hold up in the riser increases. A typical gas leakage from the riser to the fluidized bed is found to be less than 1%.

Characteristics of Erosion Variation at Haeundae Beach due to Multiple Typhoons (복수의 태풍내습에 의한 해운대 해수욕장 침식변화특성)

  • Kang, Tae-Soon;Lee, Jong-Sup;Kim, Jong-Beom;Kim, Jong-Kyu
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.7
    • /
    • pp.920-926
    • /
    • 2019
  • In this study, we analyzed the erosion variation of beach area at Haeundae Beach after coastal improvement project using video monitoring system operated by the Coastal Erosion Monitoring (Ministry of Oceans and Fisheries). Haeundae Beach was well maintained and stabilized following large scale nourishment through coastal improvement project despite of seasonal fluctuations. However, multiple typhoons over the last two years caused beach stabilization patterns and seasonal fluctuations to lost equilibrium, resulting in rapid erosion. In particular, the sandy beach was eroded by typhoon Solic and Kongray in 2018 and failed to recover beach area in winter by seasonal fluctuations. And due to multiple typhoons in 2019, the beach area was reduced 9.5 % (12,607 ㎡) year-on-year. According to analyze the observed wave and beach area data in Haeundae, the tendency of erosion and sedimentation was influenced by seasonal incident wave direction for each section(west, center and east part). Therefore, to identify the causes of decreasing seasonal fluctuation characteristics and continuous erosion, hereafter, more precise monitoring of different factors are needed, such as the crest heights of submerged breakwater and its loss of function, and sand leakage to the outside around submerged breakwater.

THE EFFECT OF FLOWABLE RESIN LINING ON THE MARGINAL MICROLEAKAGE OF CONDENSABLE RESIN RESTORATION (응축형 복합레진 수복시 유동성 레진 이장이 변연부 미세누출에 미치는 영향)

  • 문주훈;고근호
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.16-22
    • /
    • 2001
  • The purpose of this study was to evaluate the marginal microleakage of condensable composite resin restorations according to flowable resin lining of internal cavity wall. The eighty extracted human molar teeth without caries and/or restorations are used The experimental teeth were randomly assigned into four groups of ten teeth each. Eighty caries-free extracted human molars were used in this study. The conventional class II cavities (box-shaped on mesial and distal surface, faciolingual width : 3mm, gingival wall depth : 1.5mm) were prepared 1mm below cementoenamel junction with a # 701 carbide bur. The teeth were divided into four groups, and then each group were subdivided into A & B group according to flowable resin & compomer lining ; Group 1-A : Tetric Ceram filling, Group 1-B : Tetric Flow lining and Tetric Ceram filling, Group 2-A Ariston pHc filling, Group 2-B : Tetric Flow lining and Ariston pHc filing, Group 3-A SureFil filling, Group 3-B : Dyract Flow lining and SureFil filling, Group 4-A : Pyramid filling, Group 4-B : Aeliteflo lining and Pyramid filling. To simulate as closely as possible the clinical situation during retoration placement, a "restoration template" was fabricated, and the condensable resin was filled using a three-sited light-curing incremental technique. All the materials used were applied according to the manufacturers' instructions. The specimens were stored in the 100% humidity for 7 days prior to thermocycling (100 thermal cycles of 5~55$^{\circ}C$ water with a 30-second dwell time) The specimens were immersed in 2% metyleneblue dye for 24 hours, and then embedded in transparent acrylic resin and sectioned mesiodistally with diamond wheel saw. The degree of marginal leakage was scored under stereomicroscope ($\times$20) and the data were analyzed by Kruskal-Wallis test and Wilcoxon signed ranks test. The results were as follows : 1. In the gingival margins of all the group, microleakage of subgroup B was less than subgroup A. 2. In the group 1, 2, 4, there was significant differences between subgroup A and B (p<0.05), but in the group 3, there was not significant different between group 3-A (SureFil) and group 3-B (Dyract flow/SureFil) (p>0.05). 3. In the subgroup A and B, there was significant different between all group except group 4 of subgroup A. From the results above, it was suggested that the cavity lining of flowable resin and flowable compomer in condensable resin restoration decrease microleakage at gingival margin, and does improve their ability to seal the gingival margin of class II preparation.

  • PDF

MARGINAL MICROLEAKAGE OF SINGLE STEP ADHESIVES (단일 단계 접착제의 변연 미세누출)

  • Cho, Young-Gon;Jeong, Jin-Ho;Ki, Young-Jae;Choi, Hee-Young;Jin, Cheul-Hee;Yoo, Sang-Hoon;Kim, Jong-Uk;Park, Byung-Cheul
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.2
    • /
    • pp.162-169
    • /
    • 2004
  • This study evaluated the marginal microleakage of five single step adhesives. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were prepared on both buccal and lingual surfaces of extracted human molar teeth. Prepared teeth were randomly divided into five groups and restored using one of the single step adhesives and composite resins:Prompt L-Pop/Filtek Z-250 (Group 1), AQ Bond/Metafil CX (Group 2), One-Up Bond F/Palfique Toughwell (Group 3). Futurabond/Admira (Group 4), Xeno III/Spectrum TPH (Group 5). The restored teeth were thermocycled. Microleakage was assessed by dye penetration using 2% methylene blue dye solution. The teeth were bisected buccolingually and evaluated for microleakage under steromicroscope. The data were statistically analysed by Kruskal-Wallis test and Mann-Whitney tests. The results of this study were as follows:1. Microleakage of enamel margins in group 3 was statistically higher than that in groups 1, 2, 4, 5 (p < 0.05). 2. Microleakage of dentin margins in group 1 was statistically higher than that in groups 2, 5, and that in group 3 was statistically higher than that in groups 2, 4, 5 (p < 0.05). 3. Dentin marginal microleakage was higher than enamel marginal microleakage in all experimental groups. In conclusion, Prompt L-Pop showed the least leakage at enamel margin, and AQ Bond showed at dentin margin in this study. Marginal miroleakage in dentin was higher than that in enamel.

Keyword Filtering about Disaster and the Method of Detecting Area in Detecting Real-Time Event Using Twitter (트위터를 활용한 실시간 이벤트 탐지에서의 재난 키워드 필터링과 지명 검출 기법)

  • Ha, Hyunsoo;Hwang, Byung-Yeon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.5 no.7
    • /
    • pp.345-350
    • /
    • 2016
  • This research suggests the keyword filtering about disaster and the method of detecting area in real-time event detecting system by analyzing contents of twitter. The diffusion of smart-mobile has lead to a fast spread of SNS and nowadays, various researches based on studying SNS are being processed. Among SNS, the twitter has a characteristic of fast diffusion since it is written in 140 words of short paragraph. Therefore, the tweets that are written by twitter users are able to perform a role of sensor. By using these features the research has been constructed which detects the events that have been occurred. However, people became reluctant to open their information of location because it is reported that private information leakage are increasing. Also, problems associated with accuracy are occurred in process of analyzing the tweet contents that do not follow the spelling rule. Therefore, additional designing keyword filtering and the method of area detection on detecting real-time event process were required in order to develop the accuracy. This research suggests the method of keyword filtering about disaster and two methods of detecting area. One is the method of removing area noise which removes the noise that occurred in the local name words. And the other one is the method of determinating the area which confirms local name words by using landmarks. By applying the method of keyword filtering about disaster and two methods of detecting area, the accuracy has improved. It has improved 49% to 78% by using the method of removing area noise and the other accuracy has improved 49% to 89% by using the method of determinating the area.

Development of a Multichannel Eddy Current Testing Instrument(I) (다중채널 와전류탐상검사 장치 개발(I))

  • Lee, Hee-Jong;Nam, Min-Woo;Cho, Chan-Hee;Yoon, Byung-Sik;Cho, Hyun-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.155-161
    • /
    • 2010
  • Recently, the electromagnetic techniques of the eddy current testing(ECT), alternating current field testing, magnetic flux leakage testing and remote field testing have been used as a nondestructive evaluation method based on the electromagnetic induction. The eddy current testing is now widely accepted as a NDE method for the heat exchanger tube in the electric power industry, chemical, shipbuilding, and military. The ECT system mainly consists of the synthesizer module, analog module, analog-to-digital converter, power supplier, and data acquisition and analysis program. In this study, the synthesizer module and the analog module which are essential to the ECT system were primarily developed. The developed ECT system is basically a multifrequency type which is able to inject the maximum four frequencies based on the frequency and time domain multiplexing method. Conclusively, we confirmed that the EC signal was processed appropriately in each circuit modules, and the Lissajous EC signal was displayed in the impedance plane.

The Eire Risk Assessment in Compressed Natural Gas Buses & Gas Station (CNG 버스 및 충전소의 화재 위험도 평가)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.57-67
    • /
    • 2004
  • The results of the risk assessing on general buses, consisting mainly of diesel-fueled buses, show that the frequency of the instantaneous release is 1.4${\times}$10$^{-3}$ /bus/year, from which the probability of the formation of fireball as a sub event becomes 1.7${\times}$104, and show that the leakage from the CNG-fueled buses is 0.002 event/year. Also, the frequency of gradual release due to a crack is estimated at 3.7${\times}$10$^{-3}$ /buses/year, and a subsequent probability at which this could lead to a jet flame as a sub event is 1.2${\times}$10$^{-3}$ This corresponds to 0.04event/year for the CNG-fueled buses. Dividing all the fired casualties by the running distance of diesel-fueled buses, the risk is 0.091 fire fatalities per 100-million miles. And the total fire risk fur CNG buses is approximately 0.17 per 100-million miles of travel. This means that CNG buses is twice or more dangerous than diesel buses. After all CNG buses are more susceptible to the major fires. In the aspect of the reliability of this study, generic models and the failure data used in assessing the risks of CNG buses are appropriate. However, more accurate physics-based models and databases should be supplemented with this study to provide the better results.

Seismic Fragility Assessment of Liquid Storage Tanks by Finite Element Reliability Analysis (유한요소 신뢰성 해석을 통한 액체저장탱크의 지진 취약도 평가)

  • Lee, Sangmok;Lee, Young-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.718-725
    • /
    • 2017
  • A liquid storage tank is one of the most important structures in industrial complexes dealing with chemicals, and its structural damage due to an earthquake may cause a disastrous event such as the leakage of hazardous materials, fire, and explosion. It is thus essential to assess the seismic fragility of liquid storage tanks and prepare for seismic events in advance. When a liquid storage tank is oscillated by a seismic load, the hydrodynamic pressure caused by the liquid-structure interaction increases the stress and causes structural damage to the tank. Meanwhile, the seismic fragility of the structure can be estimated by considering the various sources of uncertainty and calculating the failure probabilities in a given limiting state. To accurately evaluate the seismic fragility of liquid storage tanks, a sophisticated finite element analysis is required during their reliability analysis. Therefore, in this study, FERUM-ABAQUS, a recently-developed computational platform integrated with commercial finite element and reliability analysis software packages, is introduced to perform the finite element reliability analysis and calculate the failure probability of a liquid storage tank subjected to a seismic load. FERUM-ABAUS allows for automatic data exchange between these two software packages and for the efficient seismic fragility assessment of a structure. Using this computational platform, the seismic fragility curve of a liquid storage tank is successfully obtained.