• Title/Summary/Keyword: Data fitting

Search Result 1,439, Processing Time 0.025 seconds

A Study on the Sweep Surface Modeling for Reverse Engineering (역공학을 위한 Sweep 곡면 모델링에 관한 연구)

  • 임금주;이희관;양균의
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.426-429
    • /
    • 2001
  • Many various products are manufactured which have sculptured surfaces recently. Constructing surface of these models is required technique called reverse engineering. In reverse engineering, a product which has sculptured surfaces is measured and we create surface model to acquire complete model data of object. Measured point data needs preprocess and sampling. Next a set of point data in a plane fit section curve. At last, surface is generated by fitting to section curves. Here we uses sweep surface. Sweep surface is compatible fitting CAD model to drawing. This paper discusses converting approximation of NURBS surface as a standard surface.

  • PDF

PWF-GPH method for the statistical analysis of failure time data (고장시간 자료의 통계적 분석을 위한 PWF-GPH 방법)

  • 김선영;윤복식
    • Journal of the military operations research society of Korea
    • /
    • v.22 no.1
    • /
    • pp.114-128
    • /
    • 1996
  • In this paper, a life distribution fitting method based on generalized phase-type distributions(GPH) is presented. By fitting the life distribution to a GPH, we can utilize various useful properties of the GPH. Two different approaches are used according to the properties of the given failure time data. One is an approximation to a GPH through the piecewise Weibull failure rate(PWF) model and the other is a direct approximation to a GPH using the empirical distribution function. Two numerical examples are also presented. In the first example, both of the two approaches are utilized and compared for an incomplete data set. And in the second example, the direct approximation method from an empirical distribution is utilized for the analysis of a complete data set. In both cases, we could confirm the validity of the proposed method.

  • PDF

Alternative Method of AWG Phase Measurement Based on Fitting Interference Intensity

  • Oh, Yong Ho;Lim, Sungwoo;Go, Chun Soo
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.91-94
    • /
    • 2012
  • Arrayed waveguide grating (AWG) phase errors are normally assessed from the Fourier transform of the interference intensity data in the frequency domain method. However it is possible to identify the phases directly from the intensity data if one adopts a trial-and-error method. Since the functional form of the intensity profile is known, the intensities can be calculated theoretically by assuming arbitrary phase errors. Then we decide the phases that give the best fit to the experimental data. We verified this method by a simulation. We calculated the intensities for an artificial AWG which is given arbitrary phases and amplitudes. Then we extracted the phases and amplitudes from the intensity data by using our trial-and-error method. The extracted values are in good agreement with the originally given values. This approach yields better results than the analysis using Fourier transforms.

The research on the characterization solution of eyeglass dispensing & fitting fee in optical shop (안경원의 안경 조제·가공료와 피팅비 정착화에 관한 연구)

  • Leem, Hyun-Sung;Lee, Eun-Hee;Jung, Mi-A
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.12
    • /
    • pp.391-395
    • /
    • 2017
  • In this research, we conducted a questionnaire survey of contents necessary for eyeglass dispensing & fitting fee and characterization solution of eyeglass dispensing & fitting fee. From August 1, 2016 to September 30, questionnaires were set up for 202 spectators of Seoul and Gyeonggi area, questionnaire survey was conducted online and offline. Statistical processing of all data was performed using Origin Pro 8.5. 92.1% (186 people) and 93.1% (188 people) were positively evaluating the necessity of introduction for the necessity of introducing eyeglass dispensing & fitting fee, respectively. The result suggested that it is necessary to establish the position of the optician as a medical service expert by providing a more stable policy through analysis of overseas cases of eyeglass dispensing & fitting fee.

Extraction of Electrical Parameters for Single and Differential Vias on PCB (PCB상 Single 및 Differential Via의 전기적 파라미터 추출)

  • Chae Ji Eun;Lee Hyun Bae;Park Hon June
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.4 s.334
    • /
    • pp.45-52
    • /
    • 2005
  • This paper presents the characterization of through hole vias on printed circuit board (PCB) through the time domain and frequency domain measurements. The time domain measurement was performed on a single via using the TDR, and the model parameters were extracted by the fitting simulation using HSPICE. The frequency domain measurement was also performed by using 2 port VNA, and the model parameters were extracted by fitting simulation with ADS. Using the ABCD matrices, the do-embedding equations were derived probing in the same plane in the VNA measurement. Based on the single via characterization, the differential via characterization was also performed by using TDR measurements. The time domain measurements were performed by using the odd mode and even mode sources in TDR module, and the Parameter values were extracted by fitting with HSPICE. Comparing measurements with simulations, the maximum calculated differences were $14\%$ for single vias and $17\%$ for differential vias.

Development of Smart Phone Application with User Fitting for Hearing Impaired in Various Environment (환경별 사용자 피팅이 가능한 스마트폰 보청기 어플리케이션 개발)

  • Lee, K.;Kang, S.-I.;Park, G.S.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.2
    • /
    • pp.121-128
    • /
    • 2015
  • In this paper, we introduce our smart phone application for hearing impaired people. Unlike previous hearing aids application, our application has both functions of self hearing tests and sound amplification. We provide user with two types of self hearing test, those are standard hearing test and detail hearing test. Each test has different advantages like short test time and accurate test result, however both tests provide reliable result. Our hearing test allows that user can measure their hearing loss level according to the frequency. Sound amplification function provide proper fitting formula by using NAL-NL1, and it guarantees high speech intelligibility. Our application can also memorize user's fitting data at specific test condition. Therefore those who using our hearing aids application can easily reset their hearing aids / earphone properties periodically. Our application is advanced at the aspect of self fitting function that no other previous application did. So we are expecting these comfortable processes about fitting lead the number of hearing aids user to be increased.

  • PDF

Accuracy Improvement of Boron Meter Adopting New Fitting Function and Multi-detector

  • Kong, Chidong;Lee, Hyunsuk;Tak, Taewoo;Lee, Deokjung;Kim, Si Hwan;Lyou, Seokjean
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1360-1367
    • /
    • 2016
  • This paper introduces a boron meter with improved accuracy compared with other commercially available boron meters. Its design includes a new fitting function and a multi-detector. In pressurized water reactors (PWRs) in Korea, many boron meters have been used to continuously monitor boron concentration in reactor coolant. However, it is difficult to use the boron meters in practice because the measurement uncertainty is high. For this reason, there has been a strong demand for improvement in their accuracy. In this work, a boron meter evaluation model was developed, and two approaches were considered to improve the boron meter accuracy: the first approach uses a new fitting function and the second approach uses a multi-detector. With the new fitting function, the boron concentration error was decreased from 3.30 ppm to 0.73 ppm. With the multi-detector, the count signals were contaminated with noise such as field measurement data, and analyses were repeated 1,000 times to obtain average and standard deviations of the boron concentration errors. Finally, using the new fitting formulation and multi-detector together, the average error was decreased from 5.95 ppm to 1.83 ppm and its standard deviation was decreased from 0.64 ppm to 0.26 ppm. This result represents a great improvement of the boron meter accuracy.

CHANGE-POINT DETECTION WITH SPLIT LINEAR FITS

  • Kim, Jae-Hee
    • Journal of applied mathematics & informatics
    • /
    • v.8 no.2
    • /
    • pp.641-649
    • /
    • 2001
  • A procedure of detecting change-points is considered with split linear fitting idea from Hall and Titterington(1992). At each given point, left, central and right linear fits are compared to detect the discontinuities or change-points. A simulation study is done with various types of change models and shows that the suggested technique can be a flexible data-analytic tool.

A Study for the Development of a Optimal Last for Woman's Healthy Shoes (여성화 건강제화용 기능성 라스트 개발연구)

  • 황인극;김진호
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.3
    • /
    • pp.170-176
    • /
    • 2002
  • The purpose of the present study is to find design factors that have an effect on man's foot, and to develop an optimal last for man's functional shoe design based on these factors. Analyzing 4000 men's foot data, three men were selected for fitting test with the last and shoes manufactured in the present work. Based on the results of the fitting test, the modifications of last for the optimal design have been made using CAD/CAM technologies.

  • PDF

Precision Determination of Anisotropy Constant $K_1$from Magnetization Curve of Partially Aligned Unaxial Anisotropy System

  • Kim, Yoon-Bae;Kim, Hyoung-Tae
    • Journal of Magnetics
    • /
    • v.6 no.4
    • /
    • pp.142-144
    • /
    • 2001
  • A method to deduce the rotational magnetization curve from experimental magnetization of partially aligned uniaxial anisotropy system has been investigated. The curve obtained by this process has been evaluated quire close to the theoretical magnetization curve compared to that obtained by linear extrapolation from high field data. This new approach offers better accuracy for the determination of magnetic anisotropy by fitting a calculated magnetization curve to the obversed one.

  • PDF