• Title/Summary/Keyword: Data Acquisition Equipment

Search Result 199, Processing Time 0.025 seconds

A study on the Development of the Device for Portable Safety Diagnosis and Dynamic Characteristics Analysis of Elevator using Fuzzy Algorithm (Fuzzy 알고리즘을 이용한 엘리베이터 포터블 안전진단 및 동특성 분석장치 개발)

  • 김태형;김훈모
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.123-126
    • /
    • 2000
  • An elevator system which is a essential equipment for a vertical movement of object, as a property of building, have been drove by various expenditure and purpose. Since developing electrical control technology, control systems are highly developed. An elevator equipment is expended to wide, but a data accuracy acquisition technique and safety predict technique for securing system safety is still basic level. So, objective verification for elevator confidence condition is required absolutely accuracy measurement technique. Therefore, this study is accomplished in order to conquer a method of depending on sense of a manager with a simple numeric measurement data, and construct a logical, analytical foresight system for more efficient elevator management system.

  • PDF

The study on performance test of a city railroad power facilities detection device (도시철도 전력설비 이상검출용 장치 공장시험에 대한 고찰)

  • Im, Hyeong-Gil;Ryu, Ki-Seon;Jung, Ho-Sung;Choi, Kwang-Bum;Lee, Gi-Seung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1930-1936
    • /
    • 2010
  • Because of the environmental matters the importance of the city railroad is as time goes by increasing. The case of obstacle of the power equipment which supplies electric power to city railroad will occur social and economical enormous loss. Thus, I studied on the preventing method in advance which makes it possible for us to maintain facilities efficiently. The main check points of the power facilities are voltage, current, humidity, partial discharge, move current. These points are gathered by sensor and transmitting to data acquisition device. These data are used to check equipment status in real time. In this paper I described in brief test process and results of the detection system.

  • PDF

Performance Evaluation of Balance Ability Equipment Using VR (VR을 이용한 균형능력 측정장비의 성능평가)

  • Yoon, Sangcheol;An, Howon;Ahn, Taekwon;Choi, Haesung;Lee, Byoungkwon;Seo, Dongkwon;Lee, Kyuhwan;Jung, Sangwoo;Yi, Jaehoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.33-41
    • /
    • 2020
  • Purpose : Conventional Balance Measurement can only measure the center of gravity and the shaking movement of the body. As a result, it has the disadvantages of not responding to visual changes and blocking functions of variables. This study was carried out to evaluate the performance of new equipment that measures the balance of the body using changes in body segment and pressure using the acceleration sensor to compensate for the disadvantages of the existing equipment. Methods : To this end, balance ability was measured in 43 healthy male/female adults without orthopedic injuries and nervous system damage in the last 6 months. in a situation where the visual information was restricted by Virtual Reality (VR) gear, all subjects measured and evaluated the balance ability utilizing the new equipment. Balance measurement (Prime Medilab, Korea) and Wii fit (Nintendo, Japan) were used to measure the balance ability of the subjects, and the balance ability test was performed in 4 postures using each device for data acquisition. The test duration for each posture was 30 seconds. For data acquisition, the average value of three experiments measured using each equipment was analyzed, and the statistical test was performed using the independent sample and the corresponding sample t-test, and the significance level was set to α=.05. Results : As a result of measuring the balance ability using individual equipment, blocking visual information using VR gear, the average speed, maximum speed, and moving area of the COP increased equally. It was found that the obtained absolute size of the result in Wii was somewhat larger than that of BM. Conclusion : It is considered that in the future research, it is necessary to measure changes in the body's center of gravity through image analysis, etc., to make clear comparison and evaluation of the usability.

A Study on Development and Application of Noise Estimation System for Floor Noise in Apartment Buildings (공동주택 층간소음의 소음 발생 위치 추정 시스템 개발 및 적용에 관한 연구)

  • Yun, Gee-Hyei;Kim, Sang-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.203-204
    • /
    • 2019
  • Recently, the number of conflicts and complaints related to noise between floors is increasing every year. It is essential to acquisition objective noise data in order to resolve legal disputes over floor noise. However, specialized equipment for noise acquisition is difficult for ordinary apartment dwellers to use. In addition, in order to solve the problem of inter-layer noise, it is most effective to locate and remove the noise. Therefore, this study proposes a floor noise monitoring system for the measurement of floor noise and estimation of the noise source that can be measured without a professional device.

  • PDF

Development of Full-Scale Static Test System for Aircraft Sensor Pod (항공용 센서 포드의 정적 구조시험장비 개발)

  • Jae Myung Cho;Hoon Hyuk Park;Won Woong Lee;Jong In Bae;Han Sol Lee;Eui Hwan Oh
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.1
    • /
    • pp.97-105
    • /
    • 2023
  • For aviation sensor pod, structural integrity should be verified through static structural tests for flight loads induced in various maneuvering conditions of the aircraft. For this, it is necessary to develop a test system for full-scale static load test of sensor pod. Based on test requirements, this paper introduced a test system configuration of the static test and the development of test structure frame, restraints equipment, loading equipment, control, and measurement equipment. In addition, methods and procedures for verifying the developed test system were explained. In conclusion, the static load test and data acquisition were successfully performed. Reliability of the test equipment was also verified in the process.

A Study on Defect Prediction through Real-time Monitoring of Die-Casting Process Equipment (주조공정 설비에 대한 실시간 모니터링을 통한 불량예측에 대한 연구)

  • Chulsoon Park;Heungseob Kim
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.45 no.4
    • /
    • pp.157-166
    • /
    • 2022
  • In the case of a die-casting process, defects that are difficult to confirm by visual inspection, such as shrinkage bubbles, may occur due to an error in maintaining a vacuum state. Since these casting defects are discovered during post-processing operations such as heat treatment or finishing work, they cannot be taken in advance at the casting time, which can cause a large number of defects. In this study, we propose an approach that can predict the occurrence of casting defects by defect type using machine learning technology based on casting parameter data collected from equipment in the die casting process in real time. Die-casting parameter data can basically be collected through the casting equipment controller. In order to perform classification analysis for predicting defects by defect type, labeling of casting parameters must be performed. In this study, first, the defective data set is separated by performing the primary clustering based on the total defect rate obtained during the post-processing. Second, the secondary cluster analysis is performed using the defect rate by type for the separated defect data set, and the labeling task is performed by defect type using the cluster analysis result. Finally, a classification learning model is created by collecting the entire labeled data set, and a real-time monitoring system for defect prediction using LabView and Python was implemented. When a defect is predicted, notification is performed so that the operator can cope with it, such as displaying on the monitoring screen and alarm notification.

Automatic Quality Control of Fuel Pump Motor Using Vibration Analysis (연료펌프 모터의 진동품질관리 자동화)

  • Lee J.K.;Park B.S.;Yoon J.S.;Kang E.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.303-304
    • /
    • 2006
  • In this work, we developed an equipment for automatic quality control of fuel pump motor using vibration analysis. The equipment automatically performs a series of tasks such as aligning and conveying the motor, attachment/detachment of an accelerometer, data acquisition, vibration analysis, and classification, etc. Compared to previous manual operations, the developed system is able to provide considerable savings in both time and cost.

  • PDF

Network Configuration, Time Management, and Data Storage for Urban Earthquake Disaster Preventing System (도시형 지진방재시스템을 위한 네트워크 구성, 시간관리 및 데이터 저장 방법)

  • Choi, Hun;Youn, Joosang;Heo, Gyeongyong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1675-1682
    • /
    • 2014
  • In this paper, we propose a precise time management and time synchronization based on real-time data storage and transmission scheme in design of seismic data acquisition system for urban earthquake disaster preventing system (UEDPS). It is possible to improve the performance of the existing research results through the proposed methods. To evaluate the performances of the proposed methods, we implemented a prototype system(H/W & S/W) and performed some experiments with real seismic data and test equipment generated data as the input.

Data Acquisition and Statistical Processing of Insulation Resistance for High-Power Cables in Operation (운전 중 고전력 케이블의 절연저항 데이터의 취득과 통계적 처리 방법)

  • Park, Sung-Hee;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.181-186
    • /
    • 2018
  • With progress in industrialization, facilities for generating, delivering, and receiving high levels of electric power are in great demand. The scale of electric power equipment is increasing in both size and complexity. This has contributed to the development of our modern, high-tech and information-based society. However, if the generation of electric power is suspended due to unexpected accidents at power facilities or power stations, a range of equipment the operations of which are dependent on electric power can be damaged, causing substantial socioeconomic losses in an industrial society. A great deal of time and money would be expended to repair damaged facilities at a power station, causing enormous economic loss. In order to detect the deterioration processes of power cables, and to prevent the destruction of power cables, the operation status of power cables should be monitored on a regular basis. We studied the method in order to improve accuracy and reliability for diagnosising the junction where accident occurs frequently. We present the method of data acquisition and statistical processing.

Data Acquisition System Applying TMO for GIS Preventive Diagnostic System (GIS 예방진단시스템을 위한 TMO 응용 데이터 수집 시스템)

  • Kim, Tae-Wan;Kim, Yun-Gwan;Jang, Cheon-Hyeon
    • The KIPS Transactions:PartA
    • /
    • v.16A no.6
    • /
    • pp.481-488
    • /
    • 2009
  • GIS is used to isolate large power electrical equipment using SF6 gas. While GIS has simple structure, it has few break down, relatively high reliability. But it is hard to check up faults for reason of pressure. Faults of GIS should have a ripple effect on community and be hard to recovery. Consequently, GIS imports a preventive diagnostic system to find internal faults in advance. It is most important that reliability on the GIS preventive diagnostic system, because it estimates abnormality of system by analysis result of collected data. But, exist system which used central data management is low efficiency, and hard to guarantee timeliness and accuracy of data. To guarantee timeliness and accuracy, the GIS preventive diagnostic system needs accordingly to use a real-time middleware. So, in this paper, to improve reliability of the GIS preventive diagnostic system, we use a middleware based on TMO for guaranteeing timeliness of real-time distributed computing. And we propose an improved GIS preventive diagnostic system applying data acquisition, monitoring and control methods based on the TMO model. The presented system uses the Communication Control Unit(CCU) for distributed data handling which is supported by TMO. CCU can improve performance of the GIS preventive diagnostic system by guaranteeing timeliness of data handling process and increasing reliability of data through the TMO middleware. And, it has designed to take full charge of overload on a data acquisition task had been processed in an exist server. So, it could reduce overload of the server and apply distribution environment from now. Therefore, the proposed system can improve performance and reliability of the GIS preventive diagnostic system and contribute to stable operation of GIS.