• 제목/요약/키워드: Damaged stability

검색결과 233건 처리시간 0.025초

Fluid-elastic Instability Evaluation of Steam Generator Tubes

  • Cho, Young Ki;Park, Jai Hak
    • International Journal of Safety
    • /
    • 제11권1호
    • /
    • pp.1-5
    • /
    • 2012
  • It has been reported that the plugged steam generator tube of Three Mile Island Unit 1 in America was damaged by growing flaw and then this steam generator tube destroyed the nearby steam generator tubes of normal state. On this account, stabilizer installation is necessary to prevent secondary damage of the steam generator tubes. The flow-induced vibration is one of the major causes of the fluid-elastic instability. To guarantee the structural integrity of steam generator tubes, the flow-induced vibration caused by the fluid-elastic instability is necessary to be suppressed. In this paper, the effective velocity and the critical velocity are calculated to evaluate the fluid-elastic instability. In addition, stability ratio value of the steam generator tubes is evaluated in order to propose one criterion when to determine stabilizer installation.

고온 초전도 테이프 선재의 퀀치 전파 특성 해석 (Analysis on Quench Propagation Characteristics of HTS Tape)

  • 이지광;김지훈;류경우;차귀수;한송엽
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.35-35
    • /
    • 2000
  • The main issues for the power application of High Tc superconducting tape are lower AC loss and higher stability conditions. HTS tape has large stability margin by high heat capacity of superconductor itself and high temperature margin. But, it can be damaged by continuous heat generation at quench point, because normal zone propagation velocity by generating heat is very low. Here, we analyze the quench propagation characteristics using finite element method for BSCCO-2223 HTS tape.

DCCA 처리와 산소 저온플라즈마 처리가 양모직물의 형태안정성과 태에 미치는 영향 (Effect of Low Temperature Plasma and DCCA treatment on the Dimensional Stability and Hand of Wool Fabric)

  • 정영진
    • 한국염색가공학회지
    • /
    • 제20권4호
    • /
    • pp.43-52
    • /
    • 2008
  • Wool fabric was treated with oxygen low-temperature plasma (LTP) and dichloroisocyanuric acid. The effect of dimensional stability (relaxation shrinkage, hygral expansion, felting shrinkage), tensile strength and elongation, crease recovery, and hand of wool fabric between LTP, DCCA treated wool fabrics and control wool fabric were investigated. SEM photograph showed that a little micro crack was formed on the fiber surface by plasma treatment with hard condition and epicuticle scale was damaged by DCCA treatment. Felting shrinkage, tensile strength and total hand value were much different in each samples.

손상선박의 생존성 평가 시스템에 관한 연구 (A Study on the Survivability Assessment System of Damaged Ships)

  • 이동곤
    • 대한조선학회논문집
    • /
    • 제40권2호
    • /
    • pp.34-40
    • /
    • 2003
  • Ship damage due to maritime casualties lead to marine pollution, loss of life and properties. The maritime casualties come from the rough sea and bad weather condition generally. Therefore the large-scaled casualties will be derived from loss of structural strength and stability due to the progressive flooding and enlargement of damage by the effect of wave and wind. The improvement of damage survivability is very important in maritime safety This paper described the damage survivability assessment system which can be evaluate and improve the ship safety in consideration of loading, sea and damage condition. The components of the system and decision criteria for damage stability and structural safety is established. The ship modeler and behavior analysis program in wave is developed. Finally further research work is also discussed.

격자모델을 이용한 확률론적 손상복원력 계산의 전산화 (Calculation of Probabilistic Damage Stability Based on Grid Model)

  • 남종호;김원돈;김광욱
    • 대한조선학회논문집
    • /
    • 제31권1호
    • /
    • pp.14-21
    • /
    • 1994
  • 국제해사기구(IMO)에서는 해상에서 빈번히 발생되는 선박의 사고방지를 위한 노력의 일환으로 그동안 특별한 규정이 없었던 건화물선(Dry Cargo ship)의 안정성에 관한 설계 기준을 수립하고 1992년 2월 1일부터 건화물선의 손상복원력 계산은 확률이론을 적용하여 수행하도록 하는 새로운 규정을 삽입하였다. 새로운 규정에 의하여 길이 l00m 이상의 Ro-Ro 선을 포함한 모든 건화물선에 대한 손상복원력 평가는 반드시 수행되어야 한다. 확률이론을 이용한 새로운 방법은 기존의 결정론적 방법과는 달리 계산의 복잡성, 반복성 등으로 인하여 전산 프로그램의 이용없이는 불가능하므로 프로그램 개발을 반드시 필요로 한다. 본 연구에서는 외국에서 도입되는 시스템에 대응하는 국내 자체의 전산코드 확보를 염두에 두어 새로운 규정을 해석하고 그에 따른 프로그램을 개발하였다. 특히 격자모델을 이용한 손상조합의 자동생성기법을 개발하므로써 간편한 입력체계를 실현하여 효율성과 정확성의 향상을 이루었다. 개발된 프로그램의 검증을 위하여 시험선박에 대한 예제를 수행하고 외국의 결과와 비교 분석하였다.

  • PDF

제지용 형광증백제의 열 견뢰도에 대한 연구 (Study on the Thermal Fastness of Fluorescent Whitening Agents)

  • 김철환;이지영;김병호;최재성;임기백;김다미
    • 펄프종이기술
    • /
    • 제44권1호
    • /
    • pp.10-15
    • /
    • 2012
  • Fluorescent whitening agents (FWAs) are used extensively in the paper industry to improve the optical properties. FWAs are neither photochemically nor thermally stable, and thereby the papers containing FWAs can be damaged by external heat. We observed that the CIE whiteness, ISO brightness and fluorescence index of the commercial papers decreased with the thermal treatment and thought that the thermal fastness of FWAs was the main factor affecting the thermal stability of the papers. Thus, the model papers treated with three types of FWAs were manufactured respectively and the thermal stability of FWAs was identified by determining ${\Delta}$ CIE whiteness and ${\Delta}$ fluorescence index.

유압 호스의 진동 내구성 평가를 위한 지그의 구조적 안정성에 관한 연구 (A Study on the Structural Stability of a Jig for Evaluating the Vibration Durability of a Hydraulic Hose)

  • 김재실;전민승
    • 한국기계가공학회지
    • /
    • 제20권1호
    • /
    • pp.125-131
    • /
    • 2021
  • For the vibration reliability tests, the jigs for mounting the test specimen on a vibration reliability tester are required. The dynamic stabilities of the jigs should be verified before the tests for obtaining the accurate reliability of the test specimen. This paper proposes an analytical technology for ensuring the dynamic structural stability for the test setup including the jig. The technology includes the mode analyses for checking resonance, the harmonic analyses for evaluating the dynamic structural stability of test setup including the jig, and the fatigue analyses for obtaining the durable reliability time with calculating the life cycles at the area of weakness. The cause investigation of the damaged jig during vibration reliability test of a rubber hose and the design of new revised jig are performed by using the technology. The vibration reliability test for the rubber hose with the new revised jig by analysis results is successfully conducted without any problem. Therefore the jig's design technology proposed in this paper may be useful for other items as well.

3D NAND 플래시메모리 String에 전열어닐링 적용을 가정한 기계적 안정성 분석 및 개선에 관한 연구 (Study on Improving the Mechanical Stability of 3D NAND Flash Memory String During Electro-Thermal Annealing)

  • 김유진;박준영
    • 한국전기전자재료학회논문지
    • /
    • 제35권3호
    • /
    • pp.246-254
    • /
    • 2022
  • Localized heat can be generated using electrically conductive word-lines built into a 3D NAND flash memory string. The heat anneals the gate dielectric layer and improves the endurance and retention characteristics of memory cells. However, even though the electro-thermal annealing can improve the memory operation, studies to investigate material failures resulting from electro-thermal stress have not been reported yet. In this context, this paper investigated how applying electro-thermal annealing of 3D NAND affected mechanical stability. Hot-spots, which are expected to be mechanically damaged during the electro-thermal annealing, can be determined based on understanding material characteristics such as thermal expansion, thermal conductivity, and electrical conductivity. Finally, several guidelines for improving mechanical stability are provided in terms of bias configuration as well as alternative materials.

The inspection and maintenance of pressurizer internal structures by using the tele-operated robotic manipulator in nuclear power plants

  • Jeon, Poong-Woo;Jung, Seung-Ho;Seo, Yong-Chil;Choi, Chang-Hwan;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2307-2310
    • /
    • 2005
  • A pressurizer is one of the major safety related equipment of nuclear power plants. In order to inspect and maintain the internal structures of a pressurizer, jumpers have to enter the pressurizer, in spite of the high dose exposure. Therefore, a tele-operated robotic manipulator has been developed, which consists of four parts with 2DOFs arms, a gripper, base frame, and control console. The task of this robotic manipulator is to extract the damaged electric heaters and inspect the internal structure of the pressurizer. The gripper hanging from the manipulator approaches the heaters and extracts the damaged heater by using a self-locking mechanism. In order to investigate the structural stability of the robotic manipulator, a stress analysis has been performed by using the ANSYS code. The results of this paper include the position control and vibration control of robotic gripper and the development of processing visual information for a vision sensor.

  • PDF

아동용 Luria-Nebraska 신경심리검사의 한국 표준화를 위한 예비연구 (A Preliminary Study for a Korean Version of the Luria-Nebraska Neuropsychological Battery-Children's Revision)

  • 강차연
    • 아동학회지
    • /
    • 제13권2호
    • /
    • pp.203-216
    • /
    • 1992
  • The purpose of this study was to investigate the utility of the Luria-Nebraska Battery-Children's Revision (LNNB-CR) in the clinical situation in Korea: LNNB-CR was applied clinically in order to examine how well it differentiates brain damaged children from normals. Subjects were 30 children with the average age of 10 years. Among them 15 were diagnosed as the 'brain damaged' group, and the remaining 15 were normal. All subjects of the two groups were tested on all items in accordance with LNNB-CR manual. Data were analyzed by percentage, correlation coefficient, and t-test. The results were (1) the degree of consistency between testers averaged 97.2% which confirmed the stability of the scoring system. (2) Split-half reliability was ranged from .75 on the Tactile Scale (C3) to .95 on the Memory Scale (C10). Thus, consistency of items within the scales appeared high. (3) Internal consistency reliability ranged from .74 on the Visual Scale (C4) to .98 on the Reading Scale (C9). Thus, the homogenity of items within the scales appeared high. (4) In the diagnostic discriminative power test between the two groups, both individual scales and total scores showed significant differences at the level of p<.001. (5) The discriminative power test between two groups on all items showed significant differences at the level of p<.05 or better in 126(85%) out of 149 items. These results are supportive of the diagnostic utility of the application of LNNB-CR to the clinical situation in Korea. However, extensive additional research is needed in order to prove its worth.

  • PDF