• Title/Summary/Keyword: Damage rate

Search Result 2,338, Processing Time 0.024 seconds

Numerical Ductile Tearing Simulation of Circumferential Cracked Pipe Tests under Dynamic Loading Conditions

  • Nam, Hyun-Suk;Kim, Ji-Soo;Ryu, Ho-Wan;Kim, Yun-Jae;Kim, Jin-Weon
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1252-1263
    • /
    • 2016
  • This paper presents a numerical method to simulate ductile tearing in cracked components under high strain rates using finite element damage analysis. The strain rate dependence on tensile properties and multiaxial fracture strain is characterized by the model developed by Johnson and Cook. The damage model is then defined based on the ductility exhaustion concept using the strain rate dependent multiaxial fracture strain concept. The proposed model is applied to simulate previously published three cracked pipe bending test results under two different test speed conditions. Simulated results show overall good agreement with experimental results.

An Experimental Study on the Corrosion Characteristics of Reinforcement Concrete According to Types of Surface Covering Material (표면피복재 종류에 따른 철근콘크리트의 철근 부식특성에 관한 실험적 연구)

  • 김갑수;장종호;김재환;김용로;오시덕;김무한
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.39-43
    • /
    • 2003
  • Chloride ions are considered to be the major cause of steel corrosion in concrete structures exposed to seashore environments and also permeation of chloride is controlled by chloride diffusion. Therefore, the study on chloride diffusion of concrete have been done so far by many researchers. It is reported that coating material as surface covering material is effect about deterioration of salt damage and carbonation, therefore these materials are important in durability of concrete structure. In this study, corrosion characteristics of reinforcement concrete according to types of surface covering material were evaluated by water-cement ratio, chloride penetration by age on the corrosion area rate and mass decrement of reinforcement. And it is considered that the result of this study on application of the corrosion characteristics of reinforcements under salt damage environmental will be suggested as fundamental data of control performance of salt damage. It is performed that comparison and examination of control performance of salt damage by the corrosion characteristics under salt damage environmental.

  • PDF

Formability Evaluation of Advanced High-strength Steel Sheets in Role Expansion Based on Combined Continuum-Fracture Mechanics (복합 연속체 파괴 역학에 기초한 초고강도강 판재의 구멍 넓힘 시험 성형성 평가)

  • Ma, N.;Park, T.;Kim, D.;Yoo, D.;Kim, Chong-Min;Chung, K.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.227-230
    • /
    • 2009
  • In order to predict failure behavior of advanced high-strength steel sheets (AHSS) in hole expansion tests, damage model was developed considering surface condition sensitivity (with specimens prepared by milling and punching: 340R, TRIP590, TWIP940). To account for the micro-damage initiation and evolution as well as macro-crack formation, the stress triaxiality dependent fracture criterion and rate-dependent hardening and ultimate softening behavior were characterized by performing numerical simulations and experiments for the simple tension and V-notch tests. The developed damage model and the characterized mechanical property were incorporated into the FE program ABAQUS/Explicit to perform hole expansion simulations, which showed good agreement with experiments.

  • PDF

Fatigue Damage of Quasi-Isotropic Composite Laminates Under Tensile Loading in Different Directions (인장하중방향 변화를 받는 의사등방성 복합재 적층판의 피로손상)

  • 김택현
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.2
    • /
    • pp.80-85
    • /
    • 1999
  • The purpose of this work is to investigate fatigue damage of quasi-isotropic laminates under tensile loading in different directions. Low cycle fatigue tests of [0/-60/+60]a laminates and [+30/-30/90]s lamina tes were carried out. Material systems used are AS4/Epoxy and AS4/PEEK. The fatigue damage of [+30/-30/90]s is very different from that of [0/-60/+60]s. The position of delamination generated at AS4/Epoxy and AS$/PEEK laminates were differentiated by the matrix difference that is, we suppose, the value of both GIcr(critical energy release rate of mode-I) and GIIIcr(critical energy release rate of mode-III) difference.

  • PDF

Lightning Characteristics and Lightning Rate Evaluation of Wind Farm by Lightning of Jeju Island for 2008-2012 (2008-2012년의 제주지역 낙뢰 특성 및 낙뢰에 의한 풍력단지 낙뢰율 평가)

  • Han, Ji-Hoon;Ko, Kyung-Nam;Huh, Jong-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.60-68
    • /
    • 2013
  • This paper presents the characteristics of lightning over established and scheduled wind farms of Jeju island as well as over specific range of entire Jeju Island. The lightning data for 5 years from 2008 to 2012 was obtained from IMPACT ESP which detects lightning. Lightning frequency, lightning strength and regional lightning events were analyzed in detail, and then the lightning maps of Jeju Island were created. The evaluation of lightning rate was made for all the wind farms of this study. Damage to wind turbines by lightning was found in the existing wind farms. As a result, the eastern part of Jeju Island had more lightning frequency than the western part of the Island. Also, the evaluation of lightning rate was good for all established and scheduled wind farms of Jeju Island. Hankyung is the best place for lightning safety, while precaution should be taken against lightning damage in Kimnyung. Lightning damage to wind turbines occurred in Samdal and Haengwon wind farms, which had the first and the second highest lightning rate of the five existing wind farms.

Investigation of Liquid Droplet Impingement Erosion Corrosion based on the Flow Rate of Anodized 5083-H321 Al Alloy in Seawater (경질양극산화된 5083-H321 알루미늄 합금의 해수 내 액적충격침식부식 손상 연구)

  • Shin, Dong-Ho;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.310-317
    • /
    • 2020
  • This study investigated the damage to the specimen due to liquid droplet impingement erosion corrosion, which improved the corrosion resistance and durability via hard anodization of 5083-H321 aluminum alloy, which is widely used for small ships and marine structures. The experiment combined liquid droplet impingement erosion and electrochemical equipment with the flow rates in natural seawater solution. Subsequently, Tafel extrapolation of polarization curves was performed to evaluate damage due to the liquid droplet impingement erosion corrosion. The damaged surface was observed using a 3D microscope and a scanning electron microscope. The degree of pitting damage was measured using the Image J program, and the surface hardness was measured using the micro-Vickers hardness tester. The corrosion current density, area, depth, and ratio of the damaged areas increased with the increase in flow rate. The grain size of the damaged area at a flow rate of 20 m s-1 showed fewer and minor differences in height, and a smooth curved shape. The hardness of the damaged surface tended to decrease with increase in flow rate.

A Study on the Damage Evaluation of Polyethylene Pipe by Squeeze-off (스퀴즈오프에 따른 PE배관의 손상평가 연구)

  • Ho seong Seo;Hwa young Lee;Jae-hun Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.1-6
    • /
    • 2023
  • PE piping, which has advantages in terms of construction convenience and economy, is widely used for underground burial in the domestic urban gas field. These PE pipes use squeeze-off in many sites to block gas flow during maintenance and repair work. Squeeze-off refers to a method of compressing a PE pipe to block fluid flow, and damage may occur due to the nature of construction in which the pipe is deformed by physical force. In order to prevent damage to PE pipes due to squeeze-off, the main points to be reflected in the squeeze-off operation procedures such as proper compression range, use pressure, and diameter were derived through damage assessment and confidential test according to the compression rate. The compression experiment for PE pipe damage assessment was conducted while changing the compression rate (20%~40%), the pressure of use (2.8 kPa, 25 kPa, 70 kPa), and the pipe diameters (63 mm, 90 mm, 110 mm). As a result of damage assessment according to the compression rate, damage occurred in pipes with compression rates of 45%(110mm) and 73%(63mm), which are for analyzing the effect of excessive compression. In addition, the leakage test was conducted using Ar(argon) during the squeeze-off, and as a result of the experiment, leakage occurred under the conditions of 70kPa and 110mm of pipe. As a result of this study, it was confirmed that squeeze-off for airtightness should be carried out in pipes within a range not exceeding 25 kPa and 90 mm pipes, and the appropriate compression rate to prevent damage to PE pipes is 30%.

Action of various wavelengths of visible light on U.V.-radiation damage to yeast cells. (효모세포의 자외선조해효과에 대한 각종 파장 광선의 작용)

  • 이민재;이광웅
    • Korean Journal of Microbiology
    • /
    • v.6 no.4
    • /
    • pp.122-130
    • /
    • 1968
  • Action of various wavelengths of visible light on ultraviolet-radiation damage to haploid yeast cells, Saccharomyces cerevisiae 23971, was studied. The results were obtained on the basis of the survival and respiration rates by pre- and post-illuminations of various wavelengths before and after U.V.-irradiations on the yeast cells. Among the wavelengths tested, 635 $m{\mu}$, 429 $m{\mu}$ and white light which caused increase of respiration in pre-treatment alone, induced less resistance to the U. V.-damage than in the control, in both pre- and U.V.-treatment. On the contrary, such wavelengths as 574 $m{\mu}$and 530 $m{\mu}$, showing a weak effect on respiration in pre-treatment increased the susceptability to U.V.-radiation. Photoinactivation was generally obtained by both pre- and post- illuminations along with U.V.-treatment. At 635 $m{\mu}$ the PI rate was the lowest and also a low PI rate was shown at 429 $m{\mu}$. But 429 $m{\mu}$, in the post-treatment of the yeast cells pre-treated by the white light and the darkness respectively, showed the highest PI rate. In both pre- and post- treatment of 574, 530 and 473 $m{\mu}$,the PI rates were high to the same degree. Post-treatments of the wavelengths on U.V.-treated yeasts incubated rather under the white light than the darkness induced lower PI rate. It is assumed that there are great differences in action even of the same wavelength, depending upon the various combination of pre- and post-treatments, and that, moreover, the action of various wavelengths of visible light on U.V.-damage on the cells are concerned with the doses and dose rates of U.V. and visible lights. These observations led to an interpretation that each wavelength of visible light might exert distinctively different effects oil U. V.-damage, mainly causing the inhibition or stimulation of enzymes in the yeast cells.

  • PDF

Response of Rice Yield and Grain Quality as Affected by Rice Leaf Folder (혹명나방 피해 정도에 따른 벼 수량 및 미질 반응)

  • Won, Jong-Gun;Ahn, Duok-Jong;Kim, Se-Jong;Choi, Chung-Don;Lee, Sang-Chul
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.spc
    • /
    • pp.72-77
    • /
    • 2008
  • This study was carried out to determine the response of the rice yield and grain quality by rice leaf folder (RLF, Cnaphalocrocis medinalis G.) and identify the damages caused by different transplanting dates, nitrogen amounts and chlorophyll amounts (SPAD value) of rice leaf. As the damage degree of RLF was getting severer, the ripened grain rate and 1000-grain weight were decreased and due to the increasing of chalky rice rate the rate of head rice was reduced. Therefore, the yield of head rice was decreased by 36% in heavily damaged rice plant. Among the physicochemical characteristics, protein content of rice grain was increased but amylose content was reduced, consequently, the palatability was deteriorated in heavily damaged rice by RLF. The degree of damage of RLF was getting serious as transplanting date was delayed and as the amount of nitrogen was increased. In the relationship between the SPAD value and the damage degree of RLF, as the SPAD value was increased by nitrogen fertilizing, the damage degree was also increased exponential functionally.

The Effect of Seawater Temperature on the Electrochemical Corrosion Behaviour of Stainless Steels and Anodized Aluminum Alloys (스테인리스강과 양극산화된 알루미늄 합금의 전기화학적 부식특성에 미치는 해수온도의 영향)

  • Chong, Sang-Ok;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.85-93
    • /
    • 2021
  • The corrosion damage of materials in marine environment mainly occurs by Cl- ions due to the breakdown of passive films. Additionally, various characteristics in seawater such as salinity, temperature, immersion time, flow rate, and biological activity also affect corrosion characteristics. In this study, the corrosion characteristics of stainless steels (STS 304 and STS 316L) and anodized aluminum alloys (AA 3003 and AA 6063) were evaluated with seawater temperature parameters. A potentiodynamic polarization experiment was conducted in a potential range of -0.25 V to 2.0 V at open circuit potential (OCP). Corrosion current density and corrosion potential were obtained through the Tafel extrapolation method to analyze changes in corrosion rate due to temperature. Corrosion behavior was evaluated by measuring weight loss before/after the experiment and also observing surface morphology through a scanning electronic microscope (SEM) and 3D microscopy. Weight loss, maximum damage depth and pitting damage increased as seawater temperature increased, and furthermore, the tendency of higher corrosion current density with an increase of temperature attributed to an increase in corrosion rate. There was lower pitting damage and lower corrosion current density for anodized aluminum alloys than for stainless steels as the temperature increased.