• Title/Summary/Keyword: Dam types

Search Result 178, Processing Time 0.022 seconds

Gate Operation Rule of Paldang Dam by Considering Discharge and Downstream Flow Pattern (방류량 및 하류부유황을 고려한 팔당댐의 수문조작기준 선정)

  • 서규우;이종설
    • Water for future
    • /
    • v.29 no.2
    • /
    • pp.209-219
    • /
    • 1996
  • The existing gate operation rule of Paldang hydroelectric plant has been used since the construction of the dam in 1973 except partial modification due to the construction of Chungju multipurpose dam in 1985. The water level near the downstream of Paldang dam has been lowered about 3 m because of the channel maintenance of Han River development project. Thus, the discharge estimation formula based on the submerged orifice type spillway has to be re-evaluated by considering various patterns of the gate operation rules and lowered channel bed. In this study, three types of gate openings were tested to select the proper gate operation rules through the hydraulic model test for various discharges and opening heights. Also, the numerical analysis has been performed to simulate the flow patterns of downstream. As a result, the gate operation rule, which opens 5 gates each time from the left side, was selected as the proper gate operation rule of Paldang dam.

  • PDF

A Clinical Report on The Atrophic Acne Scar with Subcision (코라테라피(절개침)을 이용한 위축성 여드름 흉터의 치험례)

  • Baek, Sang-Chul;Hong, Mu-Suk;JeGal, Hun;Jin, Yong-Hee;Joo, Tae-Min;Lee, Sang-Jun;Jo, Eun-Hee;Park, Min-Cheol
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.25 no.4
    • /
    • pp.80-88
    • /
    • 2012
  • Background and Objective : Atrophic scars are the most common complication of acne. Many modalities are proposed but each does not yield satisfactory clinical outcomes. Among therapeutic modalities of acne scars, subcision is a simple, safe procedure with a different and basic mechanism for correcting atrophic and depressed scars. However, there are few reports about such procedure. This study performed to evaluate the effect of subcision treatment on atrophic acne scar. Methods : Five patients with atrophic acne scars of various types(rolling, superficial and deep boxcar, pitted and icepick) were treated by superficial dermal undermining with 25~27 gauge needles. We used GASC(Global Acne Scarring Classification). Satisfaction degree was asked from the patients. Results and Conclusions : After observing patients satisfaction, comparing case photos and GASC, it can be considered that subcision treatment brings great results when performed on atrophic post acne scars.

Use of a Rubber Dam System in Consideration of Climate Change (기후변화 대응을 위한 고무보시스템 선정 방안 연구)

  • Hwang, Yun-Bin;Park, Ki-Hak;Kim, Seo-Hyun;Kang, Hun;Kim, Ji-ho
    • Journal of Climate Change Research
    • /
    • v.9 no.4
    • /
    • pp.319-324
    • /
    • 2018
  • Due to climate change, water shortages and water-related disasters will be serious. Since the damage and frequency of drought are increasing, the importance of water resource management technology is increasing. In this study, we analyzed the amount of greenhouse gas and the environmental impact caused by the production and operation system technologies of movable weir among various water resource management technologies. The research subjects were air inflatable rubber dams widely used in rivers and upright type rubber dams, which are an improvement on the existing rubber type. Each type of dam was studied at sizes of $1,500H{\times}10,000L\;mm$ and $3,000H{\times}20,000L\;mm$, and the two types and two sizes were compared and analyzed. Using life cycle assessment, we examined the environmental impacts using the amount of electricity required for operation and the discretionary amount required for production. In the '$1,500H{\times}10,000L$' dams, the global warming indexes were $9.35E+04kg\;CO_2-eq$. for upright type and $7.36E+04kg\;CO_2-eq$. for inflatable type. At size of '$3,000H{\times}20,000L$' the global warming indexes were $9.09E+05kg\;CO_2-eq$. for upright type and $1.07E+06kg\;CO_2-eq$. for inflatable type. Analysis of the life cycle environmental impact showed that the environmental impact of the air inflatable rubber dam was reduced by 39.8% at '$1,500H{\times}10,000L$' compared to the larger size. At the larger '$3,000H{\times}20,000L$' size, the upright dam showed a 10.1% smaller impact than the air inflatable rubber dam. Selection of water resource management system should consider climate change, not only management purpose and cost. Additional studies and improvements on rubber dam systems should be made.

Simulation of Water Temperature in the Downstream According to Withdrawal Types of Dam using EFDC Model (댐 방류형태가 하류 하천 수온변화에 미치는 영향 예측)

  • Park, Jae-Chung;Yoon, Jin-Hyuk;Jung, Yong-Moon;Son, Ji-Yeon;Song, Young-Il
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.715-724
    • /
    • 2012
  • In this study, we simulated water temperature in the downstream according to withdrawal types of dam using EFDC model. Three scenarios were assumed as water was released from the surface layer, the middle layer, and the bottom layer at intervals of 10m depth. In case of the surface layer withdrawal, the water temperature rose from March and lowered gradually after it reached a peak in August. The middle and the bottom layers effluence temperatures were lower than the surface layer temperature by maximum $15.9^{\circ}C$(in July), but after September, temperature inversion appeared. It was advantageous for the surface layer withdrawal to decrease cold damage and fog in downstream area and was possible to the middle and the bottom layers withdrawal from August to September. However, the reliability of model should be improved by accumulating the real-time information of water temperature.

The Applicability Study of SYMHYD and TANK Model Using Different Type of Objective Functions and Optimization Methods (다양한 목적 함수와 최적화 방법을 달리한 SIMHYD와TANK 모형의 적용성 연구)

  • Sung, Yun-Kyung;Kim, Sang-Hyun;Kim, Hyun-Jun;Kim, Nam-Won
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.2
    • /
    • pp.121-131
    • /
    • 2004
  • SIMHYD and TANK model are used to predict time series of daily rainfall-runoff of Soyang Dam and Youngcheon Dam watershed. The performances of SIMHYD model with 7 parameters and TANK model with17 parameters are compared. Three optimization methods (Genetic algorithm, Pattern search multi-start and Shuffled Complex Evolution algorithm) were applied to study-areas with 3 different types of objective functions. Efficiency of TANK model is higher than that of SIMHYD. Among different types of objective function, Nash-sutcliffe coefficient is found to be the most appropriateobjective function to evaluate applicability of model.

Current Status and Application of Agricultural Subsurface Dams in Korea (국내 농업용 지하댐의 현황 및 활용 사례)

  • Yong, Hwan-Ho;Song, Sung-Ho;Myoung, Woo-Ho;An, Jung-Gi;Hong, Soon-Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.3
    • /
    • pp.18-26
    • /
    • 2017
  • The increasing frequency of droughts has been increasing the necessity of utilizing subsurface dams as reliable groundwater resources in areas where it is difficult to supply adequate agricultural water using only surface water. In this study, we analyzed the current status and actual conditions of five agricultural subsurface dams as well as the effect of obtaining additional groundwater from subsurface dams operated as one aspect of the sustainable integrated water management system. Based on the construction methods and functions of each subsurface dam, the five subsurface dams are classified into three types such as those that derive water from rivers, those that prevent seawater intrusion, and those that link to a main irrigation canal. The classification is based on various conditions including topography, reservoir location, irrigation facilities, and river and alluvial deposit distributions. Agricultural groundwater upstream of subsurface dams is obtained from four to five radial collector wells. From the study, the total amount of groundwater recovered from the subsurface dam is turned out to be about 29~44% of the total irrigation water demand, which is higher than that of general agricultural groundwater of about 4.6%.

The Life Cycle Assessment of Infrastructure considering Environmental Load;A Case Study of Emergency Spillway for Korean Multipurpose Dam (환경부하량을 고려한 토목시설물 전과정평가;국내 다목적댐 비상여수로 시설 사례연구)

  • Kwun, Suk-Hyun;Kim, Sang-Kywi;Jung, Won-Ji;Kim, Sang-Beom
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2006.11a
    • /
    • pp.519-522
    • /
    • 2006
  • This study aims to provide useful information when making a decision for the environmental assessment of infrastructure, based on Life Cycle Assessment(LCA). It estimates environmental load on environmental pollutants that are possible to occur by locations and by types of emergency spillway for Korean multipurpose dam, which is selected as a study case. For this purpose, this study examines the theories of LCA and calculates environmental load on environmental pollutants that generate during life cycle, to apply the suggested infrastructure to the case study of emergency spillway at the multipurpose dam. It also evaluates environmental load of emergency spillway by the estimated result, and draws the optimum alternative that is environmental friendly.

  • PDF

Characteristics of Pollutant Loads according to Types of Sources for the Chungju Dam Watershed (충주댐 유역의 오염원에 따른 오염부하량 발생 특성)

  • Kim, Chul-Gyum;Kim, Nam-Won
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.465-472
    • /
    • 2008
  • Soil and Water Assessment Tool (SWAT) model was selected as a tool for assessing the effect of pollutant sources on the total loads from the Chungju Dam upstream watershed. The model was constructed through calibration of parameters related to nitrogen (N) and phosphorus (P), which was based on the runoff and sediment modeling performed in the previous research. Using this, the spatial and temporal pollutant loadings by source type were investigated. Results of this study indicated that in most forested upstream sub-watersheds, pollutant loadings from point sources were very low, and total loadings by point and non-point sources were also insignificant. On the other hand, in #14 sub-watershed including Jecheon city, the loadings by point source were relatively considerable. For the whole watershed, non-point sources accounted for 99% of sediment, 97% of N, and 93% of P loads. And monthly non-point source loadings were concentrated on rainy summer season, while point source loadings of N and P kept nearly constant throughout the year and were high on dry winter season relative to non-point source.

Comparison of uniform and spatially varying ground motion effects on the stochastic response of fluid-structure interaction systems

  • Bilici, Yasemin;Bayraktar, Alemdar;Adanur, Suleyman
    • Structural Engineering and Mechanics
    • /
    • v.33 no.4
    • /
    • pp.407-428
    • /
    • 2009
  • The effects of the uniform and spatially varying ground motions on the stochastic response of fluid-structure interaction system during an earthquake are investigated by using the displacement based fluid finite elements in this paper. For this purpose, variable-number-nodes two-dimensional fluid finite elements based on the Lagrangian approach is programmed in FORTRAN language and incorporated into a general-purpose computer program SVEM, which is used for stochastic dynamic analysis of solid systems under spatially varying earthquake ground motion. The spatially varying earthquake ground motion model includes wave-passage, incoherence and site-response effects. The effect of the wave-passage is considered by using various wave velocities. The incoherence effect is examined by considering the Harichandran-Vanmarcke and Luco-Wong coherency models. Homogeneous medium and firm soil types are selected for considering the site-response effect where the foundation supports are constructed. A concrete gravity dam is selected for numerical example. The S16E component recorded at Pacoima dam during the San Fernando Earthquake in 1971 is used as a ground motion. Three different analysis cases are considered for spatially varying ground motion. Displacements, stresses and hydrodynamic pressures occurring on the upstream face of the dam are calculated for each case and compare with those of uniform ground motion. It is concluded that spatially varying earthquake ground motions have important effects on the stochastic response of fluid-structure interaction systems.