검색결과 152건 처리시간 0.03초

CR 영상에서 기저선 보정을 위한 1차원 모폴로지컬 필터의 이용에 관한 연구 (Baseline Correction in Computed Radiography Images with 1D Morphological Filter)

  • 김용권;류연철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권5호
    • /
    • pp.397-405
    • /
    • 2022
  • Computed radiography (CR) systems, which convert an analog signal recorded on a cassette into a digital image, combine the characteristics of analog and digital imaging systems. Compared to digital radiography (DR) systems, CR systems have presented difficulties in evaluating system performance because of their lower detective quantum efficiency, their lower signal-to-noise ratio (SNR), and lower modulation transfer function (MTF). During the step of energy-storing and reading out, a baseline offset occurs in the edge area and makes low-frequency overestimation. The low-frequency offset component in the line spread function (LSF) critically affects the MTF and other image-analysis or qualification processes. In this study, we developed the method of baseline correction using mathematical morphology to determine the LSF and MTF of CR systems accurately. We presented a baseline correction that used a morphological filter to effectively remove the low-frequency offset from the LSF. We also tried an MTF evaluation of the CR system to demonstrate the effectiveness of the baseline correction. The MTF with a 3-pixel structuring element (SE) fluctuated since it overestimated the low-frequency component. This overestimation led the algorithm to over-compensate in the low-frequency region so that high-frequency components appeared relatively strong. The MTFs with between 11- and 15-pixel SEs showed little variation. Compared to spatial or frequency filtering that eliminated baseline effects in the edge spread function, our algorithm performed better at precisely locating the edge position and the averaged LSF was narrower.

흉부 디지털 방사선 촬영 시 C-D phantom을 이용한 촬영조건에 따른 영상 평가 (Evaluation of Image According to Exposure Conditions using Contrast-Detail Phantom for Chest Digital Radiography)

  • 이인자;김유현;김창남;이창엽;박계연
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권1호
    • /
    • pp.25-32
    • /
    • 2009
  • 흉부 DR 촬영 시 적당한 촬영조건을 알아보기 위해 C-D phantom을 이용한 영상의 평가를 식별능과 입상성 및 선량의 관계로 알아본 결과 다음과 같은 결론을 얻었다. 1. 환자 입사선량(ESE)은 관전압이 증가됨에 따라 감소되었다. 2. 노출조건 중 관전압 변화에 따른 C-D phantom의 식별능은 110 kVp에서 가장 잘 보이는 것으로 나타났다. 3. 노출비(mAs) 변화에 따른 식별능은 낮은 노출비(0.5배)에서는 90 kVp에서 가장 잘 보였으며, 노출비가 (1.5배)인 경우 110 kVp에서 가장 잘 보임을 알 수 있었고, 노출을 많이 했을 때가 식별이 잘 됨을 알 수 있었다. 4. 관전압 110 kVp에서 노출비에 따른 입상성은 1.5배일 때가 가장 좋으며, 노출비 1.5배일 때 관전압 변화 시 입상성은 110 kVp일 때가 가장 좋다. 따라서 환자의 피폭선량(Detector에 입사되는 선량은 동일)은 kVp 증가 시 작으며, 적당한 kVp는 110, 선량비는 1.0배에 비해 1.5배로 양을 많이 주었을 때가 식별이 잘 되었고, 입상성 또한 노출비가 1.5배일 때 좋으며 관전압은 110 kVp일 때가 좋았다. 그러나 노출비를 많이 주면 환자가 받는 선량이 증가됨으로 본 연구에 의하면, 노출조건을 신중히 설정하여야 할 것이다.

  • PDF

디지털 흉부 촬영에서 구리필터사용에 따른 환자 표면선량 감소효과에 관한 연구 (The Study on the Reduction of Patient Surface Dose Through the use of Copper Filter in a Digital Chest Radiography)

  • 신수인;김종일;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권3호
    • /
    • pp.223-228
    • /
    • 2008
  • 의학적으로 방사선을 사용 시 가장 중요한 점은 환자의 병을 진단 가능하되 피폭선량을 최소화시켜야 한다는 점이다. 진단용 X-선 중 장파장부분은 대부분 흡수에 관여하게 되어 환자의 피폭선량을 증가시키므로 불필요하다. 이러한 장파장영역을 제거하기 위한 방법으로 가장 효과적인 방법은 여과 판의 사용이다. 이에 부가여과가 없는 경우와 0.3mmCu filter 사용 시의 화질과 피부입사선량에 대해 실험을 해 보았다. ROC 신호용 지름 4mm, 두께 3mm의 아크릴 디스크를 chest phantom에 랜덤하게 위치시키면서 non filter 및 Cu filter시 각 각 20매씩 총 40매의 신호+잡음영상을 촬영하고, 또한 신호가 없는 영상(잡음만의 영상)을 각 각 20매씩 40매 촬영하여 총 80매의 영상을 준비한 후 5명의 방사선종사자가 판독 후 P(S/s), P(S/n) 구하여, ROC곡선을 그리고, 감도와 특이도 및 곡선하면적을 구해 평가하였다. 또한 AAPM(American Association of Physicists in Medicine by the American Institute of Physics)권고에 따른 ANSI chest phantom과 Contrast-detail phantom을 이용하여 non filter 또는 Cu filter사용 시 시각적으로 관찰 가능한 병소의 갯수를 파악하였으며, 또한 두 경우에서 피부입사선량을 측정하였다. 그 결과 Cu filter사용 시에 ROC곡선이 좌상방향에 위치하고, 감도, 곡선하면적 및 CD phantom 병소의 갯수에서 모두 좋은 결과를 나타내었다. 또한 피부입사선량은 감소가 되어 여러 측면에서 부가필터의 사용을 검토해 볼 필요가 있으리라 사료된다.

  • PDF

진단방사선영역에서 방사선장치의 이용실태 및 환자피폭선량에 관한 조사연구 (A Study on the Utilization of Diagnostic Equipments and Patient Dose for Diagnostic Radiological Procedures in Korea)

  • 김유현;최종학;김성수;이창엽;조평곤;이영배;김철민
    • 한국의학물리학회지:의학물리
    • /
    • 제16권1호
    • /
    • pp.10-15
    • /
    • 2005
  • IAEA는 영상의 질에 영향을 주지 않는 범위에서 피부흡수선량의 기준선량을 제시하였다. 이러한 개념은 점차적으로 국제적인 기준으로 사용하게 되었다. 이 기준선량은 강제사항이 아니며 권고사항이지만 방사선촬영에서 아주 훌륭한 기준이 된다. 그러나 IAEA에서 제공한 선량기준은 서양 사람을 기준으로 개발된 것이어서 우리나라 사람에게는 맞지 않고, 상대적으로 우리나라의 환자선량은 적으리라 예상된다. 따라서 방사선촬영 시 촬영부위에 따른 환자 피폭선량에 대한 기준을 따로 개발해야 할 필요가 있다. 본 연구팀은 병원협회에 등록되어 있는 종합병원 278개를 대상으로 환자 피폭에 대한 설문조사를 실시하였다. 설문회수율은 57.9%였으며 각 병원에서 답한 촬영조건을 기초로 NDD법을 이용하여 환자 피폭선량을 계산하였고 방사선장치의 이용현황을 분석한 결과는 다음과 같다 1) 방사선장치의 현황은 일반촬영장치가 42.0%, 투시촬영장치가 29.4%, 치과장치가 13.2%, CT 장치가 8.1% 그리고 유방촬영장치가 7.2%로 나타났다. 2) 방사선장치의 정류방식에 따른 분류는 삼상장치가 29.9%, 인버터장치가 29.5%, 단상장치가 25.5%, 콘덴서방식이 9.0% 그리고 무응답이 6.0%였다. 3) 방사선장치의 수광방식에 따른 분류는 F/S 방식이 46.8%, CR 방식이 26.6%, DR 방식이 17.7% 그리고 무응답이 8.9%로 나타났다. 4) 방사선 촬영건수는 흉부가 49.2%, 척추가 16.8% 그리고 복부가 12.7%순으로 나타났다. 5) 환자 피폭선량은 두부 전후방향촬영 2.23 mGy, 복부 전후방향촬영 3.20 mGy 그리고 흉부 후전방향촬영 0.28 mGy로 나타났다.

  • PDF

휴대용 시추공 카메라를 이용한 지하정보의 가시화 기법 (Visual Interpretation about the Underground Information using Borehole Camera)

  • 송정기구남;정윤영
    • 터널과지하공간
    • /
    • 제15권1호
    • /
    • pp.28-38
    • /
    • 2005
  • 근래에 들어 진행된 시추공을 이용한 각종 측정 장비의 개발에 따라 지하정보의 가시화는 중요한 관심의 초점으로 대두되었다. 이를 위해 시추공벽 영상의 모니터링과 동시에 여러 가지 분석틀을 제공할 수 있는 장비가 개발되고 있으나 불량한 암반조건이나 소수의 엔진이어만이 접근할 수 있는 곳에서는 그 장비의 활용이 극히 제한적이다. 그리하여 최소한의 기능만을 보유하고 휴대가 가능한 시추공 카메라가 개발되어 상용화 되고 있다. 본 연구에서는 휴대용 시추공 카메라를 이용하여 얻은 지하정보를 토대로 암반 내에 발달해있는 불연속면의 분포를 3차원으로 가시화 하는 수리학적인 형식화 과정과 가시화된 이미지의 해석방법을 제시하고 이에 대한 사례연구로서 두 지역에 적용하였다. 형식화 과정은 3차원 공간좌표에서 불연속면의 방향성분(경사각, 경사방향 및 심도)이 지시한 위치관계를 시추공의 선주향(trend)와 주향경사(plunge)의 변화에 기초하여 고찰함을 의미하며, 그 결과 일련의 조건식을 유도한다. 두 지역에 대한 사례연구를 통해, 본 연구에서 제시한 가시화 기법이 국지적인 불연속면의 분포가 중요한 경우 지반공학적(geotechnical)으로 유용한 수단이 될 수 있음을 알 수 있다.

분산 멀티미디어 스트리밍 시스템 설계 및 구현 (Design and Implementation of a Distribute Multimedia System)

  • 김상국;신화종;김세영;신동규;신동일
    • 한국멀티미디어학회:학술대회논문집
    • /
    • 한국멀티미디어학회 2000년도 추계학술발표논문집
    • /
    • pp.66-69
    • /
    • 2000
  • 웹이 등장하면서 지금까지 인터넷 상에서 텍스트와 이미지를 이용하여 정보를 표현하고 전달하는 방법이 가장 많이 사용되어왔다. 그러나 웹 관련 기술의 비약적인 발달과 네트워크 속도의 증가 및 인터넷의 급속한 보급으로 단순한 텍스트와 이미지 중심의 HTML 문서를 이용한 정보의 전달이 아닌 멀티미디어 데이터를 이용한 정보의 표현과 전달이 점차 증대되고 있다. 이에 따라 멀티미디어 데이터를 전송하기 위한 스트리밍 프로토콜도 등장하였다. 최근에는 컴퓨터의 성능 증가 및 네트워크 속도의 증가(초고속 통신 서비스의 보급)에 의해 멀티미디어 데이터의 전송이 가능하게 됨으로써 기존의 공중파나 CATV 방송국의 형태 지니고 인터넷 상에서 실시간 생방송 서비스와 VOD(Video On Demand) 서비스를 제공하는 인터넷 방송국이 급속하게 생겨나고 있다. (11) 인터넷 방송은 동영상과 오디오의 실시간 전달을 가능하게 하는 멀티미디어 스트리밍 기술과 멀티미디어를 실시 간으로 전송할 수 있는 실시간 전송 프로토콜을 기반으로 발전하고 있다. 인터넷 상에서 멀티미디어 스트리밍 서비스를 하는 대부분의 인터넷 방송은 스트리밍 서버로서 RealNetworks사의 RealSystem과 Microsoft사의 WMT(Windows Media Technologies)를 사용하고 있다. 본 논문은 Real Server와 WMT의 비교 분석을 통해 실시간 전송 프로토콜을 지원하고, 멀티미디어 스트리밍 기술을 지원하는 자바를 기반으로 한 분산 서버 구조의 스트리밍 서버, 서버간의 부하를 제어하는 미들웨어, 멀티미디어 스트림을 재생할 수 있는 클라이언트를 설계하고 구현한다.있다.구현한다. 이렇게 구현된 시스템은 전자 상거래, 가상 쇼핑몰, 가상 전시화, 또는 3차원 게임이나 가상교육 시스템과 같은 웹기반 응용프로그램에 사용될 수 있다.물을 보존·관리하는 것이 필요하다. 이는 도서관의 기능만으로는 감당하기 어렵기 때문에 대학정보화의 센터로서의 도서관과 공공기록물 전문 담당자로서의 대학아카이브즈가 함께 하여 대학의 공식적인 직무 관련 업무를 원활하게 지원하고, 그럼으로써 양 기관의 위상을 높이는 상승효과를 낼 수 있다.하여는, 인쇄된 일차적 정보자료의 검색방법등을 개선하고, 나아가서는 법령과 판례정보를 위한 효율적인 시스템을 구축하며, 뿐만 아니라 이용자의 요구에 충분히 대처할 수 잇는 도서관으로 변화되는 것이다. 이와 함께 가장 중요한 것은 법과대학과 사법연수원에서 법학 연구방법에 관한 강좌를 개설하여 각종 법률정보원의 활용 내지 도서관 이용방법에 관하여 교육하는 것이다.글을 연구하고, 그 결과에 의존하여서 우리의 실제의 생활에 사용하는 $\boxDr$한국어사전$\boxUl$등을 만드는 과정에서, 어떤 의미에서 실험되었다고 말할 수가 있는 언어과학의 연구의 결과에 의존하여서 수행되는 철학적인 작업이다. 여기에서는 하나의 철학적인 연구의 시작으로 받아들여지는 이 의미분석의 문제를 반성하여 본다. 것이 필요하다고 사료된다.크기에 의존하며, 또한 이러한 영향은 $(Ti_{1-x}AI_{x})N$ 피막에 존재하는 AI의 함량이 높고, 초기에 증착된 막의 업자 크기가 작을 수록 클 것으로 여겨진다. 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로

  • PDF

이중편파레이더 시뮬레이터 개발을 위한 2차원 영상우적계 관측자료의 활용가능성 연구 (Study on the Application of 2D Video Disdrometer to Develope the Polarimetric Radar Data Simulator)

  • 김해림;박혜숙;박향숙;박종서
    • 대기
    • /
    • 제24권2호
    • /
    • pp.173-188
    • /
    • 2014
  • The KMA has cooperated with the Oklahoma University in USA to develop a Polarimetric Radar Data (PRD) simulator to improve the microphysical processes in Korea Local Analysis and Prediction System (KLAPS), which is critical for the utilization of PRD into Numerical Weather Prediction (NWP) field. The simulator is like a tool to convert NWP data into PRD, so it enables us to compare NWP data with PRD directly. The simulator can simulate polarimetric radar variables such as reflectivity (Z), differential reflectivity ($Z_{DR}$), specific differential phase ($K_{DP}$), and cross-correlation coefficient (${\rho}_{hv}$) with input of the Drop Size Distribution (DSD) and scattering calculation of the hydrometeors. However, the simulator is being developed based on the foreign observation data, therefore the PRD simulator development reflecting rainfall characteristics of Korea is needed. This study analyzed a potential application of the 2-Dimension Video Disdrometer (2DVD) data by calculating the raindrop axis ratio according to the rain-types to reflect Korea's rainfall characteristics into scattering module in the simulator. The 2DVD instrument measures the precipitation DSD including the fall velocity and the shape of individual raindrops. We calculated raindrop axis ratio for stratiform, convective and mixed rainfall cases after checking the accuracy of 2DVD data, which usually represent the scattering characteristics of precipitation. The raindrop axis ratio obtained from 2DVD data are compared with those from foreign database in the simulator. The calculated the dual-polarimetric radar variables from the simulator using the obtained raindrop axis ratio are also compared with in situ dual-polarimetric observation data at Bislsan (BSL). 2DVD observation data show high accuracies in the range of 0.7~4.8% compared with in situ rain gauge data which represents 2DVD data are sufficient for the use to simulator. There are small differences of axis ratio in the diameter below 1~2 mm and above 4~5 mm, which are more obvious for bigger raindrops especially for a strong convective rainfall case. These differences of raindrop axis ratio between domestic and foreign rainfall data base suggest that the potential use of disdrometer observation can develop of a PRD simulated suitable to the Korea precipitation system.

악관절 기능장애 환자에 있어서 관절돌기의 위치적 관계 및 그 형태에 관한 방사선학적 연구 (THE ANALYSIS OF THE POSITIONAL RELATIONSHIP OF CONDYLOID PROCESS WITH MANDIBULAR FOSSA AND MORPHOLOGICAL CLASSIFICATION OF CONDYLAR HEAD IN T.M.J. TROUBLE PATIENTS)

  • 박창식
    • 치과방사선
    • /
    • 제11권1호
    • /
    • pp.7-22
    • /
    • 1981
  • 악관절 기능장애 환자를 성공적으로 진단함에 있어서, 악관절 X선 사진은 그 X선 검사 개개의 이용목적에 따라 변하는 요소를 지니고 있으나 보편적이며 제한된 2종류의 악관절 촬영 술식을 이용하여. 악관절부의 하악와와 관절돌기의 위치적 상관관계 및 해부학적 관절돌기의 방사선학적 형태와 그 형태이상의 비교 검토가 행하여 질 수 있다. 즉 transcranial view에서는 악관절부의 전후 폭경과 위치적 관계 및 이상형태를, transorbital view에서는 관절돌기의 형태학적 분류 및 내외측 관계의 정성적 관찰이 가능하다. 이에 저자는 악관절 기능장애 환자의 X선 사진 중 본 논문에 합목적적으로 사용될 수 있다고 사려되는 274예를 대상으로 예비 묘사하여 개괄적인 지식을 얻은 후, 악관절 X선 사진 174매를 사용하여 관절돌기의 위치적 관계 및 형태를 분석하여 다음과 같은 결론을 얻었다. 1. 환자의 평균연령은33.2세이고, 최빈발 연령층은 20-30세 군이었으며 남녀의 비는 1:3이었다. 2. Transcranial view에서 ㄱ) 관절돌기의 위치는 후방위가 가장 많았으며, 전방위와 중심위에서는 좌우측이 상반되는 결과를 나타냈다. ㄴ) 좌우측의 위치적 관계는 비대칭이 대칭적 관계의 6.8배의 수치를 보였으며, 대칭적 관계가 13%이며, 그중 concentricity는 4%에 불과하다. ㄷI) 관절돌기의 운동상해는 과다운동성, 과소운동성, 정점 대 정점의 순이었다. ㄹ) 관절돌기의 형태는 지시지형이 전체의 75%이상이었다. 3. Transorbital view에서 ㄱ) 관절돌기의 형태는 돌출형, 각형, 원형, 편평형의 순이었으며, 이 기본형이 87.6%, 부정형이 12. 4%를 점유했다. ㄴ) 관절돌리의 최상부의 위치는 중심부에 위치한 것이 약 80%이었다. ㄷ) 관절돌기의 내측단은 4기본형에 속했으며. 외측단은 4기본형 외에 1.4%의 부정형을 나타냈다.

  • PDF

전산화 방사선촬영(CR) 시스템을 이용한 근사적 의료 피폭 선량 평가 (Evaluation of Approximate Exposure to Low-dose Ionizing Radiation from Medical Images using a Computed Radiography (CR) System)

  • 우민선;이재승;임인철
    • 한국방사선학회논문지
    • /
    • 제6권6호
    • /
    • pp.455-464
    • /
    • 2012
  • 본 연구는 일반 X선 검사에서 CR 시스템을 이용한 환자의 근사적 피폭 선량을 평가할 수 있는 실험적 모델을 제시하고 저선량 영역에서 의료 피폭에 대한 방어의 최적화 조건으로 환자의 선량 권고량(diagnostic reference level. DRL)을 비교하고자 하였다. 이를 위하여 기준선량계와 광자극발광선량계(optically stimulated luminescence dosimeters. OSLDs)를 이용하여 관전압(kVp) 및 관전류 노출시간의 곱(mAs)에 따른 입사표면선량(entrance surface dose. ESD)을 교차 측정하였으며 CR 시스템에서 각 노출 조건에 대한 Hounsfield unit (HU) scale을 측정하여 ESD와 HU 스케일에 대한 특성 관계를 이용하여 근사적 피폭 선량을 구하였다. 또한 임상적으로 적용 가능한지를 알기 위하여 두부, 경부, 흉부, 복부, 골반부 노출 조건으로 물 팬텀에 모사하여 피폭 선량을 구하였다. 결과적으로 두 선량계의 평균 ESD는 각각 2.10, 2.01, 1.13, 2.97, 1.95 mGy 이었으며 CR 영상에서 측정한 HU 스케일은 각각 $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, $2,318{\pm}4.64$ 이었다. 이 때 ESD와 HU 스케일에 대한 특성 관계를 이용하여 근사적으로 구한 ESD는 각각 2.16, 2.06, 1.19, 3.05, 2.07 mGy이었으며 평균 측정값과 근사적으로 구한 ESD의 오차는 3% 미만으로 영상의학 분야의 측정 오차 5%를 감안한다면 신뢰할 수 있는 오차 범위라 할 수 있었다. 결론적으로 CR 시스템을 이용한 일반 X선 검사에서 환자의 피폭 선량을 근사적으로 평가할 수 있는 새로운 실험적 모델을 제시하였으며 CR 검사뿐 만 아니라 디지털 방사선촬영(digital radiography. DR) 시스템 및 필름-증감지 시스템에 적용 가능할 것으로 판단되었다.

전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가 (Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography)

  • 김정진;장성원;박장흠;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF