• Title/Summary/Keyword: DR 영상

Search Result 152, Processing Time 0.026 seconds

Construction and Performance Evaluation of Digital Radiographic System (이동형 디지털 X선 촬영장치의 구축 및 성능평가)

  • Cho, Hyo-Min;Nam, So-Ra;Lee, Chang-Lae;Jung, Ji-Young;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.144-148
    • /
    • 2007
  • Current digital radiography systems are rapidly glowing in clinical applications. The purpose of this study was to evaluate the characteristics of a mobile digital radiographic system. The performance of the mobile DR system was evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Measurements were made on a LISTEM Mobix-1000 generator and a Teleoptic PRA Alpha-R4000 detector. Imaging characteristics were measured for these two systems using the IEC-61267 defined RQA5 (kVp: 74, additional filtration: 21 mmAl) radiographic condition. The MTF at 10% was measured as 2.4 cycles/mm and the DQE(0) values for radiation exposure 0.19, 0.5, and 1.3 mR were measured as 54%, 55%, and 76%, respectively. The NPS curves gradually decreased at high spatial frequencies. This high DQE at low frequencies, may be useful for low frequency information. The results suggested that mobile DR system could be integrated with emergency ambulance system in teleradiologic imaging applications.

  • PDF

A Study on the Digital Mammography for Breast Cancer Patients (유방암 환자의 Digital Mammography에 관한 연구)

  • Lim, Cheong-Hwan;Lee, Sang-Ho;Jung, Hong-Ryang;Mo, Eun-Hui
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.63-71
    • /
    • 2012
  • This study aimed to evaluate the accuracy of breast cancer diagnosis of digital mammography which is in the highest interest of breast imaging test, and to investigate the characteristics of breast cancer patients. For this purpose, 57 breast cancer patients who underwent breast imaging test were examined between May 2010 and June 2011. The average age of the breast cancer patients was 50.8 years old, and the most frequently occurring location was the upper outer quadrant (UOQ), accounting for 33.3%. By age, the highest occurrence rate of breast cancer was the age group of 40~49, accounting for 42.1%. As for the breast composition of the breast cancer patients, fatty breast accounted for 31.6% (18/57) and dense breast for 68.4% (39/57), indicating that nearly 70% of the breast cancer patients have dense breast. It was found that the detection rate of breast cancer was the highest (45.3%) when both microcalcification and mass are simultaneously present in the radiographic lesion of the breast imaging. In dense breast, the mass without microcalcification was lower in detection rate than fatty breast. Accordingly, the mass is the cause of raising the false negative rate in dense breast. The findings show that the false negative rate of digital mammography was 7.0% and the sensitivity 93.0%. Also, the false negative rate of dense breast was 12.8%, and the sensitivity 87.2%, indicating that the sensitivity to breast cancer in this study was higher than the dense breast of previously reported screen film mammography.

Delayed Parenchymal Transit During Tc-99m MAG3 Renography is a Valuable Sign in Diagnosing Urinary Obstruction in Patients with Early Hydronephrosis (초기의 수신증 환자의 요로폐쇄 진단에 있어 Tc-99m MAG3 신장 스캔시 실질통과지연 소견의 유용성)

  • Lee, Won-Woo;Moon, Dae-Hyuk;Kim, Jae-Seung;Ryu, Jin-Sook;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.5
    • /
    • pp.306-313
    • /
    • 2002
  • Purpose: Diuretic renography (DR) can be false negative in patients with upper urinary tract obstruction due to low compliance of the renal pelvis. Delayed parenchymal transit (DPT) may be a valuable sign in case of false negative DR. We compared the diagnostic values of DR and DPT during Tc-99m MAG3 diuretic scan in adults with suspected unilateral obstructive uropathy. Materials and Methods: Fifty-four patients(male:female=30:24, age: $40.7{\pm}15.5$ yrs) who underwent Tc-99m MAG3 diuretic scan due to suspicious unilateral obstructive uropathy were analyzed. DR with a $T_{1/2}\;of\;>\;15min$ was considered as positive for obstruction. DPT was considered to be present when there was delayed appearance of radioactivity in the renal pelvis and prolonged retention of radioactivity in the renal parenchyma. The renal area ratio was defined as the ratio of pixel number of hydronephrotic kidney over that of normal contralateral at $1{\sim}2min$ images. Definition of obstruction was improved hydronephrosis after intervention, or aggravated hydronephrosis without intervention. Non-obstruction was defined as unchanged hydronephrosis over 6 months. Results: Twenty-six renal units had obstruction and 28 no obstruction. The sensitivities of DR and DPT were 69% (18/26) and 50% (13/26) respectively. Two renal units with DPT but negative DR showed the renal area ratio of <1.1. Among the 20 obstructive renal units with DPT or positive DR, 13 with DPT had lower renal area ratio than 7 renal units without DPT ($0.97{\pm}0.20\;vs\;1.30{\pm}0.41,\;p<0.05$). Differential renal function was not significantly different between these groups. DPT correctly diagnosed all renal units with non-obstruction (specificity 100%), while the specificity of DR was 89% (25/28). Conclusion: DPT during Tc-99m MAG3 diuretic scan may be a valuable sign in diagnosing urinary obstruction especially in patients with false negative DR and early HN.

Expression of CD40, CD86, and HLA-DR in CD1c+ Myeloid Dendritic Cells Isolated from Peripheral Blood in Primary Adenocarcinoma of Lung (원발성 폐선암환자의 말초혈액에서 분리한 CD1c+ 골수성 수지상 세포에서의 CD40, CD86 및 HLA-DR의 발현)

  • Kang, Moon-Chul;Kang, Chang-Hyun;Kim, Young-Tae;Kim, Joo-Hyun
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.499-505
    • /
    • 2010
  • Background: There have been several reports using animal experiments that CD1-restricted T-cells have a key role in tumor immunity. To address this issue, we studied the expression of markers for CD1c+ myeloid dendritic cells (DCs) isolated from peripheral blood in the clinical setting. Material and Method: A total of 24 patients with radiologically suspected or histologically confirmed lung cancer who underwent pulmonary resection were enrolled in this study. The patients were divided according to histology findings into three groups: primary adenocarcinoma of lung (PACL), primary squamous cell carcinoma of lung (PSqCL) and benign lung disease (BLD). We obtained 20 mL of peripheral venous blood from patients using heparin-coated syringes. Using flow-cytometry after labeling with monoclonal antibodies, data acquisition and analysis were done. Result: The ratio of CD1c+CD19- dendritic cells to CD1c+ dendritic cells were not significantly different between the three groups. CD40 (p=0.171), CD86 (p=0.037) and HLA-DR (p=0.036) were less expressed in the PACL than the BLD group. Expression of CD40 (p=0.319), CD86 (p=0.036) and HLA-DR (p=0.085) were less expressed in the PACL than the PSqCL group, but the differences were only significant for CD86. Expression of co-stimulatory markers was not different between the PSqCL and BLD groups. Expression of markers for activated DCs were dramatically lower in the PACL group than in groups with other histology (CD40 (p=0.005), CD86 (p=0.013) HLA-DR (p=0.004). Conclusion: These results suggest the possibility that CD1c+ myeloid DCs participate in control of the tumor immunity system and that low expression of markers results in lack of an immune response triggered by dendritic cells in adenocarcinoma of the lung.

Reduction of Patient Dose Exposure and Improvement of Image Quality by Use of Additional Filtration in Digital Radiology (디지털 진단방사선촬영에서 부가여과판 사용에 따른 피폭선량 감소와 화질 개선)

  • Moon, Su-Jeong;Kim, Young-Keun;Lee, Seong-Kil
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.19-25
    • /
    • 2010
  • This study is mainly for the reduction of exposure dose by using a heavy elements filter(Gd) in the digital radiology. They contained heavy elements filter of Gd and X-ray beam hardening filters such as Al and Cu. According to the results of experimental evaluation, X-ray property was not changed with variety of kVp in the case of the Gd filter. The surface dose and absorption dose were increased in order of Cu and Al. The contrast of image showed the higher value in order of Cu, Al and Gd. While the use of Gd has increased the numerical value of the CR image, and grayscale has decreased noise value of the DR image.

  • PDF

The Design of the Improved Adaptive Contrast Algorithm (개선된 적응형 콘트라스트 알고리즘 설계)

  • Choi, In-Seok;Youn, Jin-suk;Cho, Hwa-Hyun;Choi, Myung-Ryul
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.05a
    • /
    • pp.731-734
    • /
    • 2004
  • 본 논문은 입력영상의 화질 향상을 위하여 기존의 스트레칭 알고리즘을 이용하여 개선된 콘트라스트 알고리즘을 제안하였다. 입력영상의 픽셀(pixel)을 DR(Difference Range)의 범위에 따라 정해진 가중치를 적용하여 새로운 픽셀을 출력한다. 특별한 사용자 정의(User Define)없이 실시간적으로 화질을 개선할 수 있는 장점이 있다. 또한, 하드웨어 적인 측면에서 곱셈 과 나눗셈 연산을 배럴쉬프트(Barrel Shift)를 이용하여 하드웨어 복잡도를 감소 시켰다. 제안한 방식의 알고리즘의 검증을 위하여 C를 이용한 시각적 검증과 하드웨어 측면에서의 검증을 VHDL을 이용한 컴퓨터 시뮬레이션을 통해 확인하였다.

  • PDF

Evaluation of Job Performance of Radiology Students by using Field-based Radiography Course (현장중심 교육과정을 적용한 방사선과 재학생의 직무수행도 평가 -일반촬영)

  • Kwon, Soonmu;Kim, Kyoungah;Park, Changhee
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.551-557
    • /
    • 2016
  • National competency standards, which are the contents of the knowledge, skills and attitudes required to perform a job in industry, is organized by the country. the job performance was evaluated based on the National competency standards from the third-year grade of radiology students by using field-based training courses. according to the evaluation results, students showed over 93% satisfactory ratio of job performance in all radiography projection methods. Therefore, it can be predicted that field-based training courses for students made a positive effect on improving their job performance. Exposure methods with CR equipment were evaluated the best rating, yet it has various problems. The standard deviation between students was very high, and the CR operation skill of students was insufficient. Film methods was evaluated also showed problems, due to the exposure condition setting and developing operation. although DR method was rated good to the students, it was evaluated that the operation skill of DR and the ancillary equipment operation skill was shortage. By supplementing the evaluation factors below proficiency levels to a course management in each exposure method, it could help students course achievement. Also, it could help students to improve job performance of clinical areas after graduation.

Dose and Image Assessment according to Radiologic Factors Variation at Digital Humerus X-ray Examination (디지털 환경에서 Humerus 검사 시 촬영인자 변화에 따른 선량 및 화질 평가)

  • Kim, Seong Min;Hong, Seon Sook;Lee, Kwan Sup;Ha, Dong Yun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose : We aim at presenting the optimum radiologic factor through the evaluation of dose variation and of image quality through the use of a grid in Humerus examination and the change of dose because of the change of radiologic factor. Materials and Methods : We divided it in 3 cases: when using a grid or not and when using IP(Image Plate) in a digital system. Also, as fixing kVp to 70kVp it changed mAs, and fixing mAs to 10 it changed kVp, we put up resolution chart and Burger rose phantom on the acrylic phantom of 7cm (the same level of Humerus) to evaluate the dose and image. We used Image J program to evaluate the quantitative resolution of the obtained image, and made the qualitative evaluation and statistical analysis of the image saved in PACS for 20 radiologic technologist with more than 10 years of experience in order of evaluate its contrast. We used SPSS10(SPSS Inc. Chicago, Illinois) for statistical analysis. Results : We observed the analytic result of resolution by the change of kVp that it was $4.539dGycm^2$ in 60kVp and $757.472dGycm^2$ in 75kVp, which increased about 64.6% of dose, while for the resolution it had the pixel value 30.7% better with 851 in 60kVp than 651 in 75kVp. Also, we analyzed the result of resolution by the change of mAs that it was $3.106dGycm^2$ in 5mAs, and $12.470dGycm^2$ in 20mAs, which increased about 400% of dose, while for the resolution DR had 678 in 5mAs, and 724 in 20mAs that increased about 6.8% of resolution. We made the qualitative evaluation of contrast by the change of kVp that DR showed the higher quality than CR, but the contrast by the change of kVp had no special different at the moment of visual evaluation, nor statistically significant difference(P>0.05). We observed the qualitative evaluation of contraste by the change of mAs that the contrast increased as DR increased mAs, and had statistically significant difference(P<0.05). On the other hand, CR had no significant difference for more than 10mAs nor statistically significant difference(P>0.05). Conclusion : In case of some patients with radiographic exposure by the repeated examination such as emergent patient or Follow up patient, they are considered to try to limit the use of a grid, to set kVp under 65kVp in fixed mode, to select less than 10mAs and to reduce the possibility of patient being bombed.

  • PDF

Soil moisture estimation using the water cloud model and Sentinel-1 & -2 satellite image-based vegetation indices (Sentinel-1 & -2 위성영상 기반 식생지수와 Water Cloud Model을 활용한 토양수분 산정)

  • Chung, Jeehun;Lee, Yonggwan;Kim, Jinuk;Jang, Wonjin;Kim, Seongjoon
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.3
    • /
    • pp.211-224
    • /
    • 2023
  • In this study, a soil moisture estimation was performed using the Water Cloud Model (WCM), a backscatter model that considers vegetation based on SAR (Synthetic Aperture Radar). Sentinel-1 SAR and Sentinel-2 MSI (Multi-Spectral Instrument) images of a 40 × 50 km2 area including the Yongdam Dam watershed of the Geum River were collected for this study. As vegetation descriptor of WCM, Sentinel-1 based vegetation index RVI (Radar Vegetation Index), depolarization ratio (DR), and Sentinel-2 based NDVI (Normalized Difference Vegetation Index) were used, respectively. Forward modeling of WCM was performed by 3 groups, which were divided by the characteristics between backscattering coefficient and soil moisture. The clearer the linear relationship between soil moisture and the backscattering coefficient, the higher the simulation performance. To estimate the soil moisture, the simulated backscattering coefficient was inverted. The simulation performance was proportional to the forward modeling result. The WCM simulation error showed an increasing pattern from about -12dB based on the observed backscattering coefficient.

Position Improvement of a Mobile Robot by Real Time Tracking of Multiple Moving Objects (실시간 다중이동물체 추적을 통한 이동로봇의 위치개선)

  • Jin, Tae-Seok;Lee, Min-Jung;Tak, Han-Ho;Lee, In-Yong;Lee, Jun-Tak
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.11a
    • /
    • pp.415-418
    • /
    • 2007
  • 가까운 미래에 인간생활에 활용될 지능형 로봇은 인간과 공존하면서도 효과적으로 인간을 도와줄 수 있는 인간친화형 로봇이라 할 수 있다. 이러한 것을 실현하기 위해서 로봇은 미지의 환경 내에서 자신의 위치 및 방향을 인식해야 할 필요가 있다. 더욱이, 이것은 일상생활에서 자연스럽게 이뤄지는 것이 당연하다. 로봇을 제어하는 가장 중요한 문제중의 하나로서 이동로봇의 주행에서의 위치불확실성을 해결함으로서 로봇의 위치를 추정하는 것이 바람직하다 할 수 있다. 본 논문에서는 실내외 공간에서 인간을 포한함 이동물체의 영상정보를 이용하여 이동로봇의 자기위치를 인식하기 위한 방법을 제시하고 있다. 제시한 방법은 로봇자체의 DR센서 정보와 카메라에서 얻은 영상정보로부터 로봇의 위치추정방법을 결합 한 것이다. 그리고 이동물체의 이전 위치정보와 관측 카메라의 모델을 사용하여 이동물체에 대한 영상프레임 좌표와 추정된 로봇위치 간의 관계를 표현할 수 있는 식을 제시하고 있다. 또한 이동하는 인간과 로봇의 위치와 방향을 추정하기 위한 제어방법을 제시하고 이동로봇의 위치를 추정하기위해서 칼만필터 방법을 적용하였다. 그리고 시뮬레이션 및 실험을 통하여 제시한 방법을 검증하였다.

  • PDF