• Title/Summary/Keyword: DR 영상

Search Result 153, Processing Time 0.025 seconds

A Study on the Dynamic Range Performance Evaluation Method of Detector with Variation of Tube Voltage and Automatic Exposure Control (AEC) in Digital Radiography (DR) -Focused on the Dynamic Step Wedge and Histogram Evaluation (DR(Digital Radiography)에서 관전압 및 자동노출제어장치의 감도 변화에 따른 검출기의 동적 범위 성능평가 방법연구 -Dynamic Step Wedge와 히스토그램 평가를 중심으로)

  • Hwang, Jun-Ho;Choi, Ji-An;Kim, Hyun-Soo;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.4
    • /
    • pp.368-380
    • /
    • 2019
  • This study proposes a method to evaluate the performance of a detector by analyzing the dynamic step wedge and histogram according to the change of the tube voltage and sensitivity when using the Automatic Exposure Control (AEC). The performance of a detector was evaluated by measuring X-ray quality, Entrance Surface Dose (ESD), tube current, dynamic range corresponding to detector sensitivities of S200, S400, S800, S1000 per tube voltage of 60, 70, 81, 90 kVp. As a results, all of the qualities satisfied the acceptance criteria, and the Entrance Surface Dose and tube current were decreased stage by stage as sensitivity was set higher. In the dynamic step wedge, the observable dynamic range has also increased as tube voltage became higher. The histogram showed the quantization separation phenomena as the tube voltage was set higher. The higher the sensitivity, the more the underflow and overflow occurred in which the amount of information on both ends of the histogram was lost. In conclusion, the deterioration in the performance of the detector was found to be insufficient to realize the change of the tube voltage and sensitivity when using the Automatic Exposure Control, and it is useful to use dynamic step wedge and histogram in evaluating detector performance evaluation.

Prediction of Bone Aging by Adapting Image J (Image J를 활용한 뼈의 노화도 예측법)

  • Jung, Hong Moon;Won, Do Yeon;Jung, Jae Eun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.63-67
    • /
    • 2012
  • Calcium density in human bones decreases as people are getting older due to the interior or exterior environmental factors. Bone aging forms osteoporosis. And this can bring out various spine fractures which develops a complications. Thus the prediction of seniliy is one of the important factors in spine diseases. Once spine aged, diverse fractures occur such as compression fracture and micro fracture. Side images of the spine by the digital radiography (DR) were prepared, and pixel arbitrary unit with Image J was measured from one spot in the lumbar bone part. By calculating pixel arbitrary unit of the simple contrast, it was obtained that the value of pixel arbitrary unit decreased as seniliy of bones increased. By simply applying Image J to the seniliy of patient's spine, the seniliy of bones predicts the level of danger with only digital radiography(2D) image. consequently we show that Image J value of pixel arbitrary unit index for predicts the level of precaution of osteoporosis patient.

  • PDF

SDSS 자료를 이용한 z<0.01 필드은하의 자외광 특성

  • Lee, Ung;Lee, Su-Chang;Kim, Seok;Lee, Yeong-Dae;Park, Min-A;Lee, Won-Hyeong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.86.1-86.1
    • /
    • 2012
  • Sloan Digital Sky Survey (SDSS) DR7 분광자료를 이용하여 z < 0.01에 존재하는 필드(field) 은하 505개를 선별하였다. SDSS의 컬러 영상을 이용하여 필드은하들의 형태(morphology)를 타원은하/왜소타원은하, 렌즈은하/왜소렌즈은하, 나선은하, 그리고 불규칙은하로 분류하였으며, 이들 은하들에 대한 측광을 수행하였다. 한편, Galex Evolution Explorer (GALEX) 자외광 영상으로부터 선별된 은하들에 대한 자외광 측광도 수행하였다. 서로 다른 환경에 있는 은하들의 최근 별탄생 활동이 어떻게 변화하는지 파악하기 위하여 처녀자리은하단 (Virgo cluster)에 있는 은하들과 비교하여 필드은하들의 자외광-가시광 색-등급 분포를 조사하였다. 처녀자리은하단 은하들에 비하여 필드은하들은 작은 자외광-가시광색지수를 가지는 만기형 은하들의 비율이 높았다. 특히, 조기형 필드은하들의 색지수 값이 처녀자리은하단 조기형 은하들에 비해 전반적으로 더 작은 값을 나타내고, 이 특징은 질량이 작은 왜소은하에서 더욱 크게 나타남을 알 수 있었다. 한편, 환경적 효과를 거의 받지 않는 필드은하들은 환경적 효과가 큰 은하단 은하들의 진화 연구에서 환경적 효과의 크기 및 기작을 규명하는 기본 자료로 사용될 수 있음을 토의하고자 한다.

  • PDF

Intraosseous ameloblastoma masquerading as exophytic growth: a case report

  • CJ, Sanjay;David, Chaya.M;Kaul, Rachna;BK, Ramnarayan;Ramachandra, Prashanth
    • Imaging Science in Dentistry
    • /
    • v.41 no.2
    • /
    • pp.89-93
    • /
    • 2011
  • Intraosseous ameloblastoma is the most common and simple type of ameloblastoma prevalent among odontogenic tumors. Clinico-radiographically intraosseous ameloblastoma presents as slow, painless swelling or expansion of the jaws and described as multilocular expansile radiolucency that occurs most frequently in mandibular molar/ramus area. This article describes a case of follicular ameloblastoma involving 45 year old male which is different from the usual presentation, which includes-exophytic growth, different location and without expansion of the cortex.

Halo structure of old open cluster NGC 2420 (늙은 산개성단 NGC 2420의 헤일로 구조)

  • Lee, Sang Hyun;Kang, Yong-Woo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.87.1-87.1
    • /
    • 2014
  • 우리는 늙은 산개성단 NGC 2420의 외곽 헤일로 구조를 연구하였다. Sloan Digital Sky Survey (SDSS)의 DR10 자료에 공개된 g, i의 영상을 이용하여 psf측광을 수행하였다. 이로부터 얻어진 측광 자료로부터 g vs (g-i) 색-등급도, 별들의 공간분포 및 측광학적인 비 구성원별들의 공간분포의 특징을 종합적으로 고려하여 4차원 구성원 확률을 얻었다. 구성원 확률을 고려한 유효 밀도 분포를 조사하여 밝은 별과 어두운 별의 반경에 따른 분포특징을 통해 질량 분리의 증거를 살펴보았으며, 성단 외곽 헤일로의 구조에 대해 고찰한다.

  • PDF

Lipomatosis: a diverse form of hemifacial hyperplasia

  • Arora, Preeti Chawla;Umarji, Hemant R.;Arora, Aman;Ramaswami, Easwaran
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.191-195
    • /
    • 2012
  • A case of hemifacial hyperplasia that presented with muscular, skeletal, and dental hyperplasia along with lipomatous infiltration was described. Advanced imaging was useful in identifying the lipomatous infiltration present in the lesion, which raises the possibility of lipomatosis having a diverse presentation in hemifacial hyperplasia. As there was a scarcity of related literature in the field of dentomaxillofacial radiology, this report would make us familiar with its computed tomographic and magnetic resonance image findings.

Nationwise Survey of the X-ray Beam Collimator Utilization in General Diagnostic Radiograph (진단방사선 일반촬영에서의 X-ray Beam Collimator 사용 전국 실태조사)

  • Kim, Jee Hye;Sung, Dong-Wook;Kim, Jeong Wook;Shin, Jin Ho;Lee, Soon Keun;Jung, Kyung Il;Uhm, Jong Kwan;Lee, Ki Nam;Seong, Ho Jin;Kim, Youn Hyun;Kim, Hyeog Ju
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.119-126
    • /
    • 2013
  • Due to the introduction of CR and DR, it has been neglected the use of the X-ray beam collimator and field size. This study examines nationwide survey of the proper use of collimator and field size by area in a specific field of plain radiography and the current status. Authors emphasized the need for the field size criteria, and propose a standard reference field size in each specific radiologic examination. Total 333 medical institutions (included in Seoul, Gyeonggi-do, Jeolla, Chungcheong, Gangwon-do, Busan area), were investigated in relation to the status of the X-ray beam collimation field size, type specific inspection areas, medical facilities, and image analyses by type to figure out whether they use the adjustment of image field to the specific examination. To assess the awareness and the impact of radiation exposure to the collimation adjustable, 168 radiographers who was working in 10 general hospitals, 10 hospitals, and 10 clinics, were surveyed how they haver adjusted the actual field size. We examine that 61.3% of medical institutions used the "Proper collimation" and only 49.9% of them employed proper one in lumbar spine densely crowded by major organs. 69% among general hospitals, and 65% among hospitals using DR system were using proper collimation. Radiographers recognized that proper adjustment of collimation could reduce the harmful radiation dose on patients. In the survey, 97.6% of respondents were aware of this fact, but only 83.3% of respondents did the adjustment of the size of the collimation field. The using of proper collimation field was low in the nationwide survey, so the effort to reduce the radiation dose on the patients is urgently needed. A unified standard for the field accompanied by thorough education should be needed.

Measurement and Evaluation of Scatter Fractions for Digital Radiography with a Beam-Stop Array (Beam-Stop Array를 이용한 DR에서의 Scatter Fraction 측정 및 효용성 평가)

  • Choi, Yu-Na;Cho, Hyo-Min;Kim, Yi-Seul;An, Su-Jung;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2010
  • Scatter radiation considerably affects radiographic image quality by reducing image contrast and contributing to a non-uniform background. Images containing a large portion of scatter radiation may result in an incorrect diagnosis. In the past few years, many efforts have been made to reduce the effects of scatter radiation on radiographic images. The purpose of this study is to accurately measure scatter fractions and evaluate the effectiveness of beam-stop arrays. To measure scatter fraction accurately, a beam-stop array and the SFC (Scatter Fraction Calculator) program were developed. Images were obtained using the beam-stop array for both an anti-scatter technique with an anti-scatter grid and an air gap technique. The scatter fractions of the images were measured using the SFC program. Scatter fractions obtained with an anti-scatter grid were evaluated and compared to scatter fractions obtained without an anti-scatter grid. Scatter fractions were also quantitatively measured and evaluated with an air gap technique. The effectiveness of the beam-stop array was demonstrated by quantifying scatter fractions under various conditions. The results showed that a beam-stop array and the SFC program can be used to accurately measure scatter fractions in radiographic images and can be applied for both developing scatter correction methods as well as systems.

Investigation of Tube Voltage Range using Dose Comparison based on Effective Detector Exposure Index in Chest Radiography (흉부 X-ray 검사 시 선량 비교를 활용한 유효 Detector Exposure Index 기반의 적절한 관전압 범위 제안)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.139-145
    • /
    • 2021
  • This study is to confirm the range of tube voltage for Chest X-ray in DR system by comparing with dose area product (DAP) and effective dose in efficient detector exposure index (DEI) range. GE definium 8000 was used to for the phantom study. The range of tube voltage is 60~130 kVp and of mAs is 2.5~40 mAs. The acquired images were classified into efficient DEI groups, then calculated effective dose with DAP by using a PC-Based Monte Carlo Program 2.0. The signal to noise ratio (SNR) was measured at 4 regions, including the thoracic spine, the lung area with the ribs, the lung area without the ribs, and the liver by using Picture Archiving and Communication System. The significance of the group for each tube voltage was verified by performing the kruskal-wallis test and the mann-whitney test as a post-test. When set to 4 groups dependned on the tube voltage, DAP showed significant differences; 60 kVp and 80 kVp, and 60 kVp and 90 kVp (p= 0.034, 0.021). Effective dose exhibited no statistically significant differences from the all of the group (p>0.05). SNR exhibited statistically significant differences from the all of the group in the liver except compared to 80 kVp and 90 kVp (p<0.05). Therefore, high tube voltages of 100 kVp or more need to be reconsidered in terms of patient dose and imaging in order to represent an appropriate chest X-ray image in a digital system.

Simulation Study of a Large Area CMOS Image Sensor for X-ray DR Detector with Separate ROICs (센서-회로 분리형 엑스선 DR 검출기를 위한 대면적 CMOS 영상센서 모사 연구)

  • Kim, Myung Soo;Kim, Hyoungtak;Kang, Dong-uk;Yoo, Hyun Jun;Cho, Minsik;Lee, Dae Hee;Bae, Jun Hyung;Kim, Jongyul;Kim, Hyunduk;Cho, Gyuseong
    • Journal of Radiation Industry
    • /
    • v.6 no.1
    • /
    • pp.31-40
    • /
    • 2012
  • There are two methods to fabricate the readout electronic to a large-area CMOS image sensor (LACIS). One is to design and manufacture the sensor part and signal processing electronics in a single chip and the other is to integrate both parts with bump bonding or wire bonding after manufacturing both parts separately. The latter method has an advantage of the high yield because the optimized and specialized fabrication process can be chosen in designing and manufacturing each part. In this paper, LACIS chip, that is optimized design for the latter method of fabrication, is presented. The LACIS chip consists of a 3-TR pixel photodiode array, row driver (or called as a gate driver) circuit, and bonding pads to the external readout ICs. Among 4 types of the photodiode structure available in a standard CMOS process, $N_{photo}/P_{epi}$ type photodiode showed the highest quantum efficiency in the simulation study, though it requires one additional mask to control the doping concentration of $N_{photo}$ layer. The optimized channel widths and lengths of 3 pixel transistors are also determined by simulation. The select transistor is not significantly affected by channel length and width. But source follower transistor is strongly influenced by length and width. In row driver, to reduce signal time delay by high capacitance at output node, three stage inverter drivers are used. And channel width of the inverter driver increases gradually in each step. The sensor has very long metal wire that is about 170 mm. The repeater consisted of inverters is applied proper amount of pixel rows. It can help to reduce the long metal-line delay.