Evaluation of the Patient Dose in Case of Standard Radiographic Examinations Using CR and DR (표준영상의학검사를 대상으로 한 CR과 DR에서의 환자선량평가)

  • Kim, Sang-Tae;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.173-178
    • /
    • 2010
  • In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and digital radiography (DR): a difference between them can be stated in terms of dose and image quality. In the Department of Radiology our hospital, a flat-panel DR equipment (Digital diagnost, Philips) and two CR systems (ADC Compact plus digitizer, AGFA) are employed. Eight standard radiographic examinations (Skull AP, Skull LAT, Chest PA, Chest LAT, Abdomen AP, L-spine AP, L-spine LAT, Pelvis AP) were considered: doses delivered to patients in terms of both entrance skin dose (ESD) were calculated and compared in order to study the dosimetric discrepancies between CR and DR. Assessment of image quality is undertaken by Consultant Radiologists to ensure that the quality criteria for diagnostic radiographic images of the European guidelines were met. Results showed that both ESD in DR are lower than that in CR; all images met the criteria in the European Guidelines for both modalities and were used for reporting by the radiologists. Since the operators are the same and the image quality is comparable in both modalities, this study shows that in the considered examinations, DR can perform better than CR from a dosimetric point of view.

Comparison of Image Quality of the Amorphous Silicon DR System and the Film-screen Systems (비정질 실리콘 디지털 방사선 촬영기와 X-ray film과의 영상질 비교 평가)

  • Youn, Je-Woong;Lee, Hyoung-Koo;Suh, Tae-Suk;Choe, Bo-Young;Shin, Kyung-Sub;Mun, In-K.;Kim, Hong-Kwon;Han, Yong-Woo;Nam, Seung-Bae
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.161-170
    • /
    • 1999
  • System performances in terms of image quality between an amorphous silicon DR system and a conventional film-screen system were evaluated. Various aspects of image quality MTF (modulation transfer function), NPS (noise power spectrum), SNR(signal-to-noise ratio) and contrast were measured and calculated. The MTF of the DR system was comparable to the film-screen systems. The noise was mainly dominated by the quantum mottle in both systems and the electronic noise was found in the DR system. The contrast of the DR system was better than the film-screen systems by virtue of high sensitivity and image processing. Compared to the film-screen systems in general radiography, the DR system had similar resolution and showed better contrast with the same exposure condition after contrast manipulation. The results of this study provide some useful information about the performance of the DR system in connection with medical applications.

  • PDF

Study on image quality and dosage comparison of F/S system and DR system (F/S시스템과 DR시스템의 화질과 피폭선량 비교에 관한 검토)

  • Kim, Sun-Chil;Jung, Jae-Eun
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.7-11
    • /
    • 2003
  • Currently, many hospitals are hastening to introduce digital radiography systems. This is a direct result of the intentions to improve medical services and to digitalize radiology information systems, and is also leading to the improvement of medical imaging technology. Throughout F/S system's long history, many people have researched the image quality and dosage concerning these systems, and as a result, huge improvements in the dosage of patients were possible. Similarly, I believe that DR systems need the same kind of effort. Of course, decreases in dosage that ignore image quality are unthinkable. The results of experiments conducted by five hospitals during a period of 3 months brought to us the conclusions listed below. 1. Based on the comparison and analysis of the exposure control of F/S systems and DR systems, DR systems generally showed higher exposure control for parts of the phantom that became thicker, and the exposure control improved rapidly as the thickness increased. 2. DR systems still proved to be somewhat deficient in resolution measurements compared to existing F/S systems. The image processing part of DR systems contributed much to these result. 3. Under conditions used clinically, the dosage measurements of DR systems were generally higher regardless of region. 4. According to the evaluation of image quality, DR systems showed a higher degree of satisfaction as the thickness of the region became thinner. As mentioned above and based on the mutual relationship experiments between the dosage and image quality of F/S systems and DR systems, research to increase the satisfaction of DR systems must be considered.

  • PDF

A Comparative Study on Image Quality of Breast Image Tests using ACR Phantom (ACR 팬텀을 이용한 시스템별 유방검사 영상의 비교 연구)

  • Hong, Dong-Hee;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.241-247
    • /
    • 2006
  • Recently, interests and utilization on Computed Radiography(CR) and Digital Radiography(DR) tends to increase owing to an introduction of Picture Archiving and Communication System(PACS) and an accuracy control of special medical equipment for a breast imaging examination. This study was intended to compare and analyze a detector's imaging quality by each system to be used for the breast imaging examination by using ACR Phantom used at the accuracy control. As an evaluation method, a significance and reliability of image's value using the ACR Phantom was analyzed by using SPSS program. The results are followed. 1. For the fiber, there was 3.9 score in Screen-Film, 4.2 score in CR($50{\mu}m$), 3.2 score in CR($100{\mu}m$), and 4.2 score in DR. There was the high score in the order of CR($50{\mu}m$), DR, Screen-Film, and CR($100{\mu}m$)(P<0.05). 2. For the calcification, there was 2.7 score in Screen-Film, 2.5 score in CR($50{\mu}m$), 2.0 score in CR($100{\mu}m$), and 2.9 score in DR. There was the high score in the order of DR, Screen-Film, CR($50{\mu}m$), and CR($100{\mu}m$).(0.025(P<0.05). 3. For Mass, there was 3.8 score in Screen-Film, 3.8 score in CR($50{\mu}m$), 3.6 score in CR($100{\mu}m$), and 4.5 score in DR. There was the high score in the order of DR, CR($50{\mu}m$), Screen-Film, and CR($100{\mu}m$) (P<0.1). 4. As the total score, there was 10.4 score in Screen-Film, 10.6 score in CR($50{\mu}m$), 8.7 score in CR($100{\mu}m$), and 11.3 score in DR. There was the high score in the order of DR, $CR(50{\mu}m$), Screen-Film, and $CR(100{\mu}m$). As shown in the above results, it can be known that DR and Screen-Film System has higher image quality than CR. But, DR has unstability caused by element, and Screen-Film has the low image quality caused by artifact as disadvantages. When Dual-Side CR($50{\mu}m$) was used among CR systems which had the problem of low image quality, it was indicated that there was no difference with Screen-Film System. Because the radiation imaging examination tends to become digitalized, each system for the breast imaging examination will need to be developed and supplemented.

  • PDF

A comparative study for resolution and density of chest imaging using film/screen, CR and DR (X-ray 흉부영상 FIlm/Screen, CR, DR Resolution과 Density 비교평가)

  • An, Byeong-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • The objective of this study was to compare the resolution and density appropriate to diagnosis in chest PA radiography. In comparing the resolution, we radiographed with conventional radiography, computed radiography(CR) and digital radiography(DR) using the linear resolution phantom(Nuclear Associates-Carle Place. N.Y.). 2 radiologists and 3 radiological technologists read the resolution value by the blind test. DR, conventional radiography and CR measured 3.95, 3.58, 3.48 resolution value respectively. In analysing the density, we chose the fifty normal chest CR and DR and conventional film. We estimated the density using by densitometer(X-rite company-Model 301) in seven regions(lung field, lung field margine, mediastinum I, mediastinum II, heart shadow I, heart shadow II, diaphragm) of chest film. We adapted to analysis the Japanese chest X-ray evaluating method and table. It was scored 0(farthest density value) to 2(nearest density value). DR scored 2 at mediastinum I, mediastinum II, heart shadow I, heart shadow II and diaphragm. On the contrary with, CR scored 2 at lung field and lung field margine. Consequently, DR superior than CR and conventional radiography film compairing density and resolution. It was due to small pixel size and post processing algorithm with digital radiography.

A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System (Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구)

  • Hong, Sun Suk;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.247-253
    • /
    • 2013
  • The purpose is a comparative evaluation in the DR System according to the dosimetry and image quality of the quantitative and objective via Direct digital radiography, Indirect digital radiography, Image intensifier (Charge Coupled Device type) digital radiography. The experimental method used rando phantom and measured the entrance surface dose. And through using the measured entrance surface dose and then using the PCXMC program were evaluated risk due to irradiation and the effective dose. SNR and NPS and CNR were measured and analyzed by using 21cm acryl phantom. Significance of measured value was evaluated by statistics method. Entrance surface dose, major organ dose, effective dose all of them were measured the lowest rated in direct DR when it is on the basis of direct DR dose, high-dose ratio were measured in I.I DR approximately 1.3 times, indirect DR approximately 2.4 times. Risk in accordance with radiation also was measured same as dose ratio. On the conclusion that SNR measurement result based on direct DR SNR measurements, low-SNR ratio were measured in I.I DR approximately 7.25 times, indirect DR approximately 1.48 times. On the conclusion that CNR measurement result based on direct DR CNR measurements, high-dose ratio were measured in I.I type DR approximately 1.16 tims and low-dose ratio were measured in indirect DR approximately 0.87 times. Therefore Direct DR system using a-selenium sensing element to detect x-ray photon is thought effectively at the examination such as infant to sensitive irradiation and the genital gland. Because quality image is built by low dose. Also when it is necessary that image test requiring many diagnosis information, indirect DR system is thought effectively.

Effects of Ultrasonic Scanner Setting Parameters on the Quality of Ultrasonic Images (초음파 진단기의 설정 파라미터가 영상의 질에 미치는 효과)

  • Yang, Jeong-Hwa;Lee, Kyung-Sung;Kang, Gwan-Suk;Paeng, Dong-Guk;Choi, Min-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.57-65
    • /
    • 2008
  • Setting parameters of Ultrasonic scanners influence the quality of ultrasonic images. In order to obtain optimized images sonographers need to understand the effects of the setting parameters on ultrasonic images. The present study considered typical four parameters including TGC (Time Gain Control), Gain, Frequency, DR (Dynamic Range). LCS (low contrast sensitivity) was chosen to quantitatively compare the quality of the images. In the present experiment LCS targets of a standard ultrasonic test phantom (539, ATS, USA) were imaged using a clinical ultrasonic scanner (SA-9000 PRIME, Medison, Korea). Altering the settings in the parameters of the ultrasonic scanner, 6 LCS target images (+15 dB, +6 dB, +3 dB, -3 dB, -6 dB, -15 dB) to each setting were obtained, and their LCS values were calculated. The results show that the mean pixel value (LCS) is the highest at the max setting in TGC, mid to max in gain and pen mode in frequency and 40-66 dB in DR. Among all images, the image being the highest in LCS was obtained at the setting of DR 40 dB. It is expected that the results will be of use in setting the parameters when ultrasonically examining masses often clinically found In either solid lesions (similar to +15, +6, +3 dB targets) or cystic lesions (similar to -15, -6, -3 dB targets).

Quantitative Analysis and Comparison of DR and CR image quality (CR과 DR 영상화질의 정량적 비교분석)

  • Park, Hey-Suk;Seo, Jang-Yeon;Jeong, Jin-Hwa;Lee, Chang-Lae;Cho, Hyo-Min;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.31-37
    • /
    • 2007
  • The purpose of this research was to compare and analyze image quality for each Detector of CR(Computed Radiography) and DR(Digital Radiography). The results showed that CR(AGFA MD 4.0 General plate, JAPAN) was superior to DR(HOLOGIC nDirect Ray, USA) based on the quantitative values and comparison of MTF(Modulation Transfer Function), NPS(Noise Power Spectrum), Photon fluence and DQE(Detective Quantum Efficiency) which have been widely accepted for the estimation of CR and DR. Quantitative evaluations of CR and DR system were obtained and they may be very helpful for QA and QC of general X-ray systems.

  • PDF

An Effective Medical Image System using TFT-DXD Method's Digital X-ray Detector (TFT-DXD 방식의 디지털 X-ray Detector를 이용한 고효율 의료 영상처리시스템)

  • Hwang, Jae-Suk;Lee, Jae-Kyun;Lee, Chae-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.4C
    • /
    • pp.389-395
    • /
    • 2007
  • The Film X-ray and the CCD method of current medical image system have the disadvantages such as required large place and diagnosis time. In this paper, we implement an effective medical image system using TXT-DXD method's digital X-ray detector(DR1000C). The implemented medical image system has advantages of placing efficiency and short diagnosis time. In order to make the image out of the system more effective, we develop an LCD(Liquid Crystal Display) control driver, having the resolution of 1900*1200. And we propose an enhancement unsharp masking method to update image enhancement of DR1000C medical image system, and compare it with the current methods.

Effects of Settings in Dynamic Ranges and Frequency Modes on Ultrasonic Images (초음파 영상에서 동적영역과 주파수 방식의 설정에 따른 효과)

  • Yang, Jeong-Hwa;Kang, Gwan-Suk;Lee, Kyung-Sung;Paeng, Dong-Guk;Choi, Min-Joo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.277-283
    • /
    • 2009
  • It is important to get clinical ultrasonic images of good quality for accurate diagnosis. In this study, it observed the change of ultrasonic images against setting frequency, dynamic range(DR) and type of probes on ultrasonic scanner. In the experiment it evaluated image of LCS (Low Contrast Sensitivity) targets(-15, -6, -3, +3, +6, +15 dB) of a standard ultrasonic test phantoms(539,551, ATS, USA) similar to solid and cystic lesions. Its imaged from convex (C3-7IM) and linear probe (L5-12IM) on SA-9900 (Medison Ltd, Korea) scanner. The images obtained altering the setting parameters which are frequency(gen, pen, res, harmonic) mode and DR($40{\sim}100\;dB$). The quality of images evaluated compare with the nominal LCS value of target and measured LCS value. The results show that there was no significant changing of quality images altering DR 40, 60, 80, 100 dB against frequency in Convex probe but the image being the highest in LCS target at DR 60 dB, harmonic of frequency mode in the -15 dB target close to cystic lesion. In Linear probe, DR 40 dB, harmonic mode at -15 dB LCS target close to nominal value. It discussed necessity of evaluation about ROC(Receiver Operating Characteristic) from the psychological viewpoint and limit of evaluation from quantified images.