• Title/Summary/Keyword: DQ

Search Result 325, Processing Time 0.034 seconds

Vector Control of an Induction Motor with Forced Commutated Cycloconverter (강제전류 싸이크로콘버터에 의한 유도전동기 벡터제어)

  • Gi Taek Kim
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.9
    • /
    • pp.1239-1246
    • /
    • 1995
  • A forced commutated cycloconverter (FCC) is a direct ac-ac converter capable of providing simultaneous voltage and frequency transformations. In this paper, vector control of an induction motor controlling stator current with forced commutated cycloconverter is presented. The advantage of current control is that the stator dynamics are eliminated and high performance vector control can be achieved. A novel modulation method based on dq transformation techniques is presented. Proposed modulation strategy generates the low frequency modulation function by the instantaneous value of the desired output voltages not by the steady state values of output magnitude and output frequency. PI control and predictive control algorithm for current control are applied, and the validity of proposed method is confirmed through digital simulations. Simulation results of step response and torque distubance and current control are presented.

  • PDF

Comparative Study of Field-Oriented Control in Different Coordinate Systems for DTP-PMSM

  • Zhang, Ping;Zhang, Wei;Shen, Xiaofeng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.3
    • /
    • pp.330-335
    • /
    • 2013
  • This paper performs two kinds of Field-Oriented Control (FOC) for dual three phase permanent magnet synchronous motor (DTP-PMSM).The first is based on vector space decomposition to study the effect of current harmonics on electromechanical energy conversion. And the second presents the coupling relations between two sets of windings using two d-q transformation. And then this paper has deeply studied the differences between these two strategies, the different effect on the control of harmonic current and the reason for these differences. MATLAB-based Simulation studies of a 3KW DTP-PMSM are carried out to verify the analysis of differences between the two FOC strategies.

Control Characteristics of Three-Phase Utility Interactive Phovotovoltaic Power Generation System (3상 계통연계 태양광발전시스템의 운전특성)

  • Kim, Yeong-Cheol;Jeong, Myeong-Ung;Seo, Gi-Yeong;Lee, Hyeon-U;U, Jun-In
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.8
    • /
    • pp.536-543
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper present a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL Control system and the Phase detector of Interactive Voltage by using dq transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor.

  • PDF

Vibration analysis of FG nanobeams based on third-order shear deformation theory under various boundary conditions

  • Jandaghian, Ali Akbar;Rahmani, Omid
    • Steel and Composite Structures
    • /
    • v.25 no.1
    • /
    • pp.67-78
    • /
    • 2017
  • In this study, free vibration of functionally graded (FG) micro/nanobeams based on nonlocal third-order shear deformation theory and under different boundary conditions is investigated by applying the differential quadrature method. Third-order shear deformation theory can consider the both small-scale effects and quadratic variation of shear strain and hence shear stress along the FG nanobeam thickness. The governing equations are obtained by using the Hamilton's principle, based on third-order shear deformation beam theory. The differential quadrature (DQ) method is used to discretize the model and attain the natural frequencies and mode shapes. The properties of FG micro/nanobeam are assumed to be chanfged along the thickness direction based on the simple power law distribution. The effects of various parameters such as the nonlocal parameter, gradient index, boundary conditions and mode number on the vibration characteristics of FG micro/nanobeams are discussed in detail.

Control of Parallel Connected Three-Phase PWM Converters without Inter-Module Reactors

  • Jassim, Bassim M.H.;Zahawi, Bashar;Atkinson, David J.
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.116-122
    • /
    • 2015
  • This paper presents a new current sharing control strategy for parallel-connected, synchronised three-phase DC-AC converters employing space vector pulse width modulation (SVPWM) without current sharing reactors. Unlike conventional control methods, the proposed method breaks the paths of the circulating current by dividing the switching cycle evenly between parallel connected equally rated converters. Accordingly, any inter-module reactors or circulating current control will be redundant, leading to reductions in system costs, size, and control algorithm complexity. Each converter in the new scheme employs a synchronous dq current regulator that uses only local information to attain a desired converter current. A stability analysis of the current controller is included together with a simulation of the converter and load current waveforms. Experimental results from a 2.5kVA test rig are included to verify the proposed control method.

A Comparative Study of Controllers for CSI Fed Induction Motor

  • Kumar, Piush;Agarwal, Vineeta
    • Journal of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.165-170
    • /
    • 2010
  • This paper presents a comparative study of P and PI controllers for a current source inverter (CSI) fed induction motor drive system. A dq model has been used which incorporates the induction motor and the inverter power supply with current feedback. The model is used first to generate the steady state curves to determine the operating point through computer simulations using the software package MATLAB. Then a transient analysis has been carried out for different values of the speed and current controller parameters. The controller value is adjusted by the Ziegler-Nichols method. It has been observed that the transient time to reach the steady state value is larger with the PI controller than with the P controller.

Output Phase Synchronization Method of Inverter for Parallel Operation of Uninterruptible Power System (무정전전원장치 병렬운전을 위한 인버터의 출력 위상 동기화 방법)

  • Kim, Heui-Joo;Park, Jong-Myeon;Oh, Se-Hyung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.3
    • /
    • pp.235-241
    • /
    • 2020
  • In this paper, we propose the bus/bypass synchronization phase lock loop (B-Sync PLL) method using each phase voltage controller of a parallel UPS inverter. The B-Sync PLL included in each phase voltage control system of parallel UPS inverters has the transient response and the phase synchronization error at grid normal or blackout. The validity of this method is verified by simulation and experiment. As a result, the parallel UPS inverters using the proposed method confirmed that the output phase was continuously synchronized when a grid blackout, improving the transient response characteristics for stable load power supply and equal load sharing.

Induction motor rotor speed estimation using discrete adaptive observer (이산 적응 관측자를 이용한 유도전동기의 회전자 속도 추정)

  • Yi, Sang-Chul;Choi, Chang-Ho;Nam, Kwang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1060-1062
    • /
    • 1996
  • This paper presents a discrete adaptive observer for MIMO system of an IM model in DQ reference model. The IM model in the stationary frame is discretized and it is transformed into the canonical observer form. The unknown parameter is choosen as rotor speed. The adaptive law for parameter adjustment is obtained as a set of recursive equations which are derived by utilizing an exponentially weighted normalized least-square method. The proposed adaptive observer converges rapidly and is also shown to track time-varying plant parameter quickly. Its effectiveness has been demonstrated by computer simulation.

  • PDF

Analysis of Dynamic Characteristics of Three Phase Induction Motor Applied by Various Unbalanced Voltage (다양한 불평형 전압이 인가된 3상 유도전동기의 동적특성 분석)

  • Kim, Tae-Han;Jwa, Chong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.810-812
    • /
    • 2003
  • The dynamic characteristics of a three phase induction motor which is applied by various unbalanced voltages are simulated and analyzed in this paper. The voltage equations and torque equation in the dq stationary reference frame for the three phase star connected induction motor are used in this analysis. MATLAB and SIMULINK are employed as a simulation tool. The dynamic characteristics of speed and torque are simulated for various unbalanced voltages, that is, (1) cases with the same unbalance voltage factor but different unbalanced voltages, (2) cases with only one unbalanced voltages but different degree of unbalance, and (3) cases with the same positive sequence voltage but different negative sequence voltages. The simulated results are compared and analyzed with each other, and also with the results of balanced voltage.

  • PDF

A Study on indirect Vector Control of Induction motors using TMS320F240 (TMS320F240을 이용한 유도전동기의 간접 벡터제어에 관한 연구)

  • Yun, Hong-Min;Kim, Yong;Baek, Soo-Hyun;Lee, Seung-Il;Lee, Eun-Young
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.372-374
    • /
    • 2000
  • This paper presents a study on the indirect FOC (field oriented control) of induction motor using TMS320F240. This DSP has become possible to design and implement a highly efficient and accurate AC induction drive control. This paper describes a pulse width modulator based on the voltage space vectors technique that accepts voltage demands in dq coordinates and generates three-phase PWM waveforms to drive a variable frequency voltage-source inverter. The Current Model lock is added to generate the rotor flux angular speed.

  • PDF