• Title/Summary/Keyword: DOPPLER

Search Result 2,266, Processing Time 0.029 seconds

Automatic Extraction of Blood Flow Area in Brachial Artery for Suspicious Hypertension Patients from Color Doppler Sonography with Fuzzy C-Means Clustering

  • Kim, Kwang Baek;Song, Doo Heon;Yun, Sang-Seok
    • Journal of information and communication convergence engineering
    • /
    • v.16 no.4
    • /
    • pp.258-263
    • /
    • 2018
  • Color Doppler sonography is a useful tool for examining blood flow and related indices. However, it should be done by well-trained operator, that is, operator subjectivity exists. In this paper, we propose an automatic blood flow area extraction method from brachial artery that would be an essential building block of computer aided color Doppler analyzer. Specifically, our concern is to examine hypertension suspicious (prehypertension) patients who might develop their symptoms to established hypertension in the future. The proposed method uses fuzzy C-means clustering as quantization engine with careful seeding of the number of clusters from histogram analysis. The experiment verifies that the proposed method is feasible in that the successful extraction rates are 96% (successful in 48 out of 50 test cases) and demonstrated better performance than K-means based method in specificity and sensitivity analysis but the proposed method should be further refined as the retrospective analysis pointed out.

Formation of a Stationary Light Pulse in a Doppler-Broadened EIT Medium

  • Chough, Y.T.
    • Journal of the Korean Physical Society
    • /
    • v.73 no.10
    • /
    • pp.1479-1485
    • /
    • 2018
  • A number of experiments have been performed on light slowing and stopping in the electromagnetically induced transparency (EIT) media of hot atomic gases where the Doppler-shift may add detunings to the field frequencies in an inhomogeneous fashion. We provide here a theoretical analysis as to the effect of such a Doppler-broadened environment on the dynamics of the system in comparison to a cold atomic medium. We will show that one of the most critical factors in the formation of a stationary light pulse is the enhancement of the excited-state decay rate caused by the collisions between the atoms of the medium and the molecules of the buffer gas.

A novel analytical solution of the deformed Doppler broadening function using the Kaniadakis distribution and the comparison of computational efficiencies with the numerical solution

  • Abreu, Willian V. de;Martinez, Aquilino S.;Carmo, Eduardo D. do;Goncalves, Alessandro C.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1471-1481
    • /
    • 2022
  • This paper aims to present a new method for obtaining an analytical solution for the Kaniadakis Doppler broadening (KDB) function. Also, in this work, we report the computational efficiencies of this solution compared with the numerical one. The solution of the differential equation achieved in this paper is free of approximations and is, consequently, a more robust methodology for obtaining an analytical representation of ψk. Moreover, the results show an improvement in efficiency using the analytical approximation, indicating that it may be helpful in different applications that require the calculation of the deformed Doppler broadening function.

Introduction to Knobology Focusing on B Mode and Doppler Setting in Musculoskeletal Ultrasound (근골격계 초음파의 기판 조절 입문: B Mode와 Doppler)

  • Min, Kyunghoon
    • Clinical Pain
    • /
    • v.20 no.1
    • /
    • pp.7-14
    • /
    • 2021
  • Musculoskeletal ultrasound has evolved as the essential tool to diagnose and guide intervention procedures in people with neuromusculoskeletal conditions. Image optimization and understanding device operations are core components for ultrasound guided intervention procedure training. All ultrasound machines share the common operative features and there are various buttons for the features in the device control panel. Ultrasound "knobology" refers to the thorough understanding of imaging optimization. This review addressed basic information for the transducers, depth setting, gain and focus control, different modes focusing on brightness and doppler modes.

Detection of Segmental Branch Renal Artery Stenosis by Doppler US: A Case Report

  • Chang Kyu Seong;Seung Hyup Kim;Jung Suk Sim
    • Korean Journal of Radiology
    • /
    • v.2 no.1
    • /
    • pp.57-60
    • /
    • 2001
  • In stenosis of a segmental branch or among multiple renal arteries, Doppler sampling of intrarenal arteries in the upper, mid and lower poles demonstrates strikingly different waveform patterns that might otherwise be overlooked. We report a case of segmental branch renal artery stenosis in which a pulsus parvus et tardus waveform was observed in a segmental branch of a renal artery. In this case, systematic analysis of Doppler waveforms of intrarenal arteries at more than three different locations facilitated a rapid and confident diagnosis of segmental branch renal artery stenosis.

  • PDF

Characteristic Analysis on Feedback Interference Channels in Rural Regions and Sides of Highways (시외 지역과 고속도로변에서 궤환 간섭 채널의 특성 분석)

  • Moon, Woo-Sik;Seo, Man-Jung;Im, Sung-Bin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.6
    • /
    • pp.48-55
    • /
    • 2009
  • The feedback interference channels are those made through the multipaths that are built by moving and stationary objects around transmit and receive antennas mounted at the same point. This paper describes the method to measure the feedback interference channels in the rural regions and sides of highways and the analysis on channel characteristic parameters. Using the measured samples, we estimated scattering functions, delay power spectra, and Doppler power spectra, and we analyzed the channels using eight parameters including coherence bandwidth, coherence time, maximum excess delay, average excess delay, rms delay spread, Doppler shift, Doppler spread, and spread factor, and delay and Doppler cumulative distributions. Even though many observations are made, note that the feedback signals of high Doppler frequencies and large energy are observed in the sides of highways due to high speed vehicles while low Doppler frequencies occurred in the rural region due to rare traffic.

Compact Doppler Sensor Using Oscillator Type Active Antenna (능동 발진 안테나를 이용한 소형 도플러 센서)

  • Yun, Gi-Ho
    • Journal of IKEEE
    • /
    • v.15 no.1
    • /
    • pp.49-56
    • /
    • 2011
  • In this paper, a compact doppler sensor with oscillator type active antenna operating at 2.4GHz frequency band is proposed to measure the distance or speed of a moving object. The active antenna has been realized by oscillator using radiator, patch antenna, as its resonator. The oscillation frequency is shifted depending on approaching of the object, and a detection circuit discriminates the frequency deviation. The oscillator type active antenna has been designed and simulated. The prototype fabricated has a very small circular disk type of diameter 30mm and height 4.2mm. As for antenna performance, broadside radiation pattern with beamwidth of $130^{\circ}$ and oscillation frequency of 2.373GHz has been measured. Test results as a doppler sensor shows that doppler signal voltage of about 190mV has been obtained for conducting plate moving 1 meter away from the sensor. And, doppler signal voltage has been linearly increased to the ground from 4.5m height by free-falling the sensor.

Clinical Observation on Blood Flow of Facial Acupuncture Points in Bell's Palsy Patients by Doppler Ultrasound (도플러 초음파검사를 이용한 안면마비 환자의 안면부 경혈의 혈류 관찰)

  • Yin, Chang-Shik;Bae, Young-Min;Choi, Yang-Sik;Ko, Jeong-Min;Kim, Sergey;Kang, Uk;Lee, Sang-Hoon
    • Journal of Acupuncture Research
    • /
    • v.26 no.2
    • /
    • pp.49-58
    • /
    • 2009
  • Objectives : The aim of this study was to investigate whether Doppler ultrasound device is applicable for the evaluation of facial palsy patients. Methods : A total of 25 patients participated in the first assessment and 22 of them finished a follow-up assessment one week later. An assessment comprised of a Minimax-Doppler-K device examination on bilateral acupoints $ST_5$, $SI_{19}$, $ST_2$, and $BL_1$, House-Brackmann grading, and subjective symptom questionnaire. Measurement reliability was assessed and clinically meaningful variations of Doppler measurement values were explored. Results : Doppler ultrasound examination revealed a significant difference of some measurement values between values of the symptom side and the contralateral side, between groups of severe paralysis and moderate paralysis, and between groups of short duration(0-3 weeks) and long duration (3 weeks-5 months) by non-parametric analyses (p<0.05). Several re-examination values showed a significant correlation with the first examination values by Spearman's correlation tests (p<0.05). Conclusions : This study revealed several possibilities for the clinical application of this device. Further validity tests and device improvements for a user's convenience would be helpful for its practical application.

  • PDF

High Resolution Forward-Looking Collision Avoidance Automotive Radar Using Stepped-Frequency Pulsed-Doppler(SFPD) Technique (계단 주파수 변조된 펄스 도플러 기법을 이용한 고해상도 전방 충돌 회피용 차량 레이다 성능 분석)

  • Woo, Sung-Chul;Kwag, Young-Kil
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.784-790
    • /
    • 2009
  • A forward-looking automotive radar typically utilizes the frequency modulated continuous wave(FMCW) or pulsed-Doppler waveform for the Information acquisition of the target range and velocity. In order to obtain the high resolution target information, however, a narrow pulse width and wide bandwidth are inherently required, thus resulting in high peak power and high speed digital converter processing. In this paper, a stepped-frequency pulsed-Doppler(SFPD) waveform algorithm is proposed for high resolution forward looking automotive radar application. The performance of the proposed SFPD waveform technique is analyzed and compared with the conventional FMCW and PD method. Since this technique can be used for the high resolution target imaging with arbitrary range and Doppler resolution, it is expected to be useful In automotive radar target classification for the precision collision avoidance applications in the future.