• 제목/요약/키워드: DMA

검색결과 499건 처리시간 0.023초

에폭시/마이크로실리카/나노실리카 혼합 콤포지트의 열적, 전기적 특성 (Thermal, Electrical Properties for Epoxy/Microsilica/Nanosilica Composites)

  • 강근배;권순석;박재준
    • 한국전기전자재료학회논문지
    • /
    • 제25권10호
    • /
    • pp.779-785
    • /
    • 2012
  • The epoxy/micro-and nano-mixed silica composites(EMNC) systems were prepared and the AC insulation breakdown strength was evaluated. Glass transition temperature (Tg) and crosslink density were also measured by dynamic mechanical analyzer(DMA) in order to correlate them with the electrical and mechanical properties, and the effect of silane coupling agent on the electrical properties was also studied. Electrical properties and crosslink density of epoxy/micro-silica composite were noticeably improved by addition of nano-silica and silane coupling agent, and the highest breakdown strength was obtained by addition of 0.5~5 phr of nano-silica and 2.5 phr of silane coupling agent, and the highest tensile and flexural strength were obtained by addition of 2.5 phr of nano-silica.

고해상도 심전계의 개발 (Development of a High-Resolution Electrocardiography)

  • 이호성;우응제;박승훈;이종민;박광석
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.179-183
    • /
    • 1996
  • Most of the conventional electrocardiogaphies fail to detect signals other than P-QRS-T due to the limited SNR and bandwidth. High-resolution electrocardiography (HRECG) provides better SNR and wider bandwidth for the detection of micro-potentials with higher frequency components such as ventricual late potentials(LP). In this paper, we developed a HRECG using uncorrected XYZ lead. The overall gain of the amplifier is 4000 and the bandwidth is $0.5{\sim}300Hz$ without using 60Hz notch filter. Three 16-bit AH converters sample X, Y, and Z signals simultaneously with a sampling frequency of 2000Hz. Sampled data are transmitted to PC via a DMA-controlled serial communication channel using RS-485 and HDLC protocol. The noise level of the developed HRECG is less than $5{\mu}V_{rms,\;RTI}$. In order to further reduce the noise level, signal averaging technique is implemented utilizing template matching method. The SNR of the developed HRECG is high enough for the detection of LP.

  • PDF

PPS/ABS 블렌드의 형태학적/열적 특성 (Morphology and Thermal Properties of PPS/ABS Blends)

  • 이영관;김준명;남재도;박찬석;장승필
    • 폴리머
    • /
    • 제24권3호
    • /
    • pp.366-373
    • /
    • 2000
  • 본 연구에서는 poly(phenylene sulfide)(PPS)와 ABS의 물성을 상호보완하기 위하여 블렌드를 제조하였다. 각 성분간의 상용성을 증진시키기 위하여 소량의 무수말레인산을 ABS에 반응시켜 MABS (ABS-g-MAH)를 제조하였으며, PPS/ABS 및 PPS/MABS 블렌드는 이축 혼련 압출기를 이용하여 용융 흔합하였다. 블렌드에서 ABS의 화학적 개질이 블렌드의 모폴로지와 열적 성질에 미치는 영향을 관찰하였다. PPS/MABS 블렌드의 경우, 각 성분간에 강한 인력이 형성되는 것을 광학현미경과 SEM을 이용하여 확인하였으며, DMA 분석에서는 단일 유리전이 온도를 확인하였다. 또한 화학적으로 개질된 MABS를 사용한 PPS/MABS의 블렌드는 PPS/ABS보다 향상된 열적 성질을 나타내었다.

  • PDF

액정고분자 복합계의 in-situ 횡단면 배향을 위한 공정개발 (Process Development for in-situ Transverse Orientation of TLCP Fibril in PC/TLCP Blends)

  • 이재욱
    • 유변학
    • /
    • 제10권2호
    • /
    • pp.82-91
    • /
    • 1998
  • 액정고분자/폴리카보네이트 혼합계로 구성된 분자복합계를 쉬트상으로 가공할 때 취 약해지기 쉬운 횡단면 방향의 물성을 향상시키기 위하여 미세섬유상의 배향을 in-situ 상태 로 적절히 제어할수 있는 Simultaneous Convergent-Divergent(SCD) 다이를 설계·제작하 고 압출실험을 수행하여 얻은 압출 쉬트를 대상으로 구조-물성-가공의 상관관계를 조사하 였다. 액정고분자의 첨가 함량에 따른 토오크와 토출량의 변화는 액정고분자를 10wt% 소량 첨가하였음에도 현저한 감소 효과를 보였으며 약 30wt%일 때 최소로되었다. 이는 액정고분 자가 보강 기능외에 가공특성의 개선에도 큰 효과가 있어 가공조제로서의 가능성을 보이는 결과로 혼합계의 유변학적 특성 결과에서도 확인할수 있었다. 또 DSC와 DMA를 이용한 열 분석 결과 액정고분자의 함량이 증가함에 따라 PC의 유리전이온도가 다소 감소하는 현상을 보임에 미루어 이 혼합계는 부분적으로 상용성을 갖는 것으로 볼수 있으며 모폴로지 분석을 통해서도 이를 확인할수 있었다. TLCP/PC 혼합계로 구성되는 분자복합재를 SCD 다이를 사용하여 제조한 압출 쉬트의 방향성에 따른 기계적 물성은 기존의 쉬트 다이보다 흐름방향 으로는 다소 낮은 물성치를 보이지만 횡단면 방향으로는 물성이 현저히 향상됨을 관찰할수 있었다. 모폴로지 분석결과 기존의 쉬트 다이의 경우 벽면 부근에서는 액정고분자가 미세섬 유상으로 형성되어 흐름방향으로 배향되어 있지만 중심부에서는 액정 상태로 존재하는 반 면, SCD 다이의 경우 미세섬유상으로 형성된 액정고분자가 벽면에서부터 중심부로 갈수록 횡단면 방향으로 서서히 배향되어 있음을 확인할수 있었다.

  • PDF

미세입자 측정용 간이형 3단 전기적 저압 임펙터의 설계 및 성능평가 (Design and Performance Evaluation of a Portable 3-Stage Electrical Low Pressure Impactor(P-ELI) for Measurements of Submicron Aerosol)

  • 조명훈;지준호;박동호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제28권7호
    • /
    • pp.826-833
    • /
    • 2004
  • Cascade impactors are widely used to collect size classified aerosol. A major disadvantage of this instrument is the required long sampling time. Electrical low pressure impactor has been developed to overcome this disadvantage and to achieve real-time measurements on the particle size distribution. The instrument consists primarily of a corona charger, low pressure cascade impactor and multi channel electrometer. We designed and evaluated the performance of a potable 3-stage low pressure impactor using an electrical method. For the calibration of the impactor, monodispersed particles were generated using evaporation-condensation method followed by electrostatic classification using a DMA(Differential Mobility Analyzer). The collection efficiency curves of the stages can be determined by analysing the fraction of particles collected by each stage.

Electron Beam-induced Crosslinking and Characterization of Polycaprolactone Films in the Presence of Various Crosslinking Agents

  • Kang, Dong-Woo;Jung, Chan-Hee;Hwang, In-Tae;Choi, Jae-Hak;Nho, Young-Chang
    • 방사선산업학회지
    • /
    • 제5권2호
    • /
    • pp.107-112
    • /
    • 2011
  • Electron beam-induced crosslinking of polycaprolactone (PCL) films containing various crosslinking agents (CAs) was investigated in this study. PCL films containing various CAs prepared by a solution casting method were irradiated by electron beams at various absorption doses and the irradiated PCL films were investigated in terms of their crosslinking degree, thermal and mechanical properties, and biodegradability. Based on the results of the crosslinking degree measurement, triallyl isocyanurate was found to be most effective for the electron-beam induced crosslinking of PCL films. The results of the UTM, DMA, and TMA revealed that the thermal and mechanical properties of the crosslinked PCL films were greatly improved in comparison to those of the pure PCL. The results of the enzymatic degradation test revealed that the biodegradability of the crosslinked PCL films was reduced in comparison to that of the pure PCL.

에폭시 아크릴레이트의 전자선 영향 평가 (Characterization of Electron Beam Cured Epoxy Acrylate)

  • 신진욱;오병환;고금진;전준표;강필현
    • 방사선산업학회지
    • /
    • 제4권3호
    • /
    • pp.271-276
    • /
    • 2010
  • Epoxy resin has wide application in various industrial fields because of their good mechanical strength, superiority adhesion and low shrinkage etc. And the typical curing method for epoxy resins is thermal and press compaction. However, a curing method was used electron beam process in this study. Epoxy acrylate was fabricated from mixture of epoxy, acrylic acid, tetraphenylporphyrin (TPP) and hydroquinone monomethyl ether (MEHQ) with mole ratios. Then electron beam irradiation effect on the curing of the epoxy acrylate resin was investigated various absorption dose in nitrogen atmospheres at room temperature. The dynamic mechanical and thermal properties of the irradiated epoxy acrylate resins were characterized using dynamic mechanical analysis (DMA) and thermogravimetric analyzer (TGA). And the tensile and flexural strength were measured by an universal tensile machine (UTM).

방사선 경화 비닐에스터 수지의 기계적 특성 연구 (Mechanical Properties of Radiation-Curing Vinyl Ester Resin)

  • 신범식;전준표;김현빈;강필현
    • 방사선산업학회지
    • /
    • 제4권1호
    • /
    • pp.19-23
    • /
    • 2010
  • Vinyl ester (VE) resins, introduced in the late 1960s, have made large strides in reinforced plastics applications as adhesive and matrix materials on their appropriate mechanical performance characteristics in the glassy state. Generally, VE resins are a group of dimethacrylate resins based on bisphenol A type epoxy resin. They exhibit easy handling properties as well as good resistance to most chemical agents due to their mechanical and thermal properties. In this study, the effects of curing methods of vinyl ester resins on gel contents, flexural strength and dynamic mechanical properties were investigated. Thermal curing (room temperature, $80^{\circ}C$) and electron beam curing were used to crosslink a VE resin/styrene complex (65/35 wt%) with methyl ethyl ketone peroxide (MEKPO) as a catalyst and an 8 wt% cobalt naphthenate in styrene solution as a accelerator. For the samples, gel contents as well as flexural strength and dynamic mechanical properties were characterized and compared by soxhlet apparatus, universal testing machine (UTM) and dynamic mechanical analysis (DMA). As a result, the electron-cured VE resin was confirmed as a better condition than those for gel contents, flexural strength and dynamic mechanical properties, respectively.

초임계 유체 염색기술 적용 PET 섬유의 물리적 및 열적 특성 분석 (A Study of Physical and Thermal Properties of Dyed PET Fiber using Supercritical Fluid Dyeing Technology)

  • 김삼수;오지연;박창표;이상오;이재웅
    • 한국염색가공학회지
    • /
    • 제31권3호
    • /
    • pp.147-154
    • /
    • 2019
  • In this study, poly(ethylene terephthalate)(PET) fibres dyed with Disperse Red 167 using supercritical $CO_2$ technology. The purpose of this study was to investigate relationship between PET fibers and supercritical $CO_2$ during dyeing. The effects of temperature, pressure, dyeing time and mass ratio between the dye and PET in the dyeing chamber were considered. Thermal and mechanical properties of the fibers were investigated. Tensile strength of dyed PET fibers decreased at higher temperature and pressure conditions. DSC and DMA results indicated that the Tg and Tm values decreased significantly when compared to the pure PET fibers. However, uniformly dyed PET fibers were typically observed.

Analysis of Physical Properties of Hydrogel Lenses Polymer Containing Styrene and PVP

  • Lee, Min-Jae;Sung, A-Young
    • 한국재료학회지
    • /
    • 제29권7호
    • /
    • pp.399-407
    • /
    • 2019
  • This research is carried out to analyze the effects of Styrene and PVP on the properties of silicone hydrogel lenses. Styrene group and PVP(Polyvinylpyrrolidone) are used as additives for a basic combination containing silicone monomer, TSMA(trimethylsilyl methacrylate) and DMA(n,n-dimethylacrylamide) added to the mix at ratios of 1~10 %. Silicone hydrogel lens is produced by cast-mold method. The polymerized lens sample is hydrated in a 0.9 % saline solution for 24 hours before its optical and physical characteristics are measured. Measurement of the physical characteristics of the produced material shows that the refractive index is 1.3682~1.4321, water content 77.11~45.73 %, visible light transmittance 95.14~88.20 %, and tensile strength 0.0652~0.3113 kgf. The results show a decrease of refractive index as the ratio of additives and water content decreases. The result of the stabilization test of polymerization show an increase of extractables along with increase of the ratio of additives, but the difference is not significant for all samples, so it can be judged that the stabilization of the polymer is maintained. Therefore, the additions of styrene and PVP should be taken into consideration for their effects on the physical properties of silicone hydrogel lens.