References
- Maricq, M. M., Podsiadlik, D. H. and Chase, R. E., 2000, 'Size Distribution of Motor Vehicle Exhaust PM: A Comparison Between ELPI and SMPS Measurement,' Aerosol Sci. Technol., Vol. 43, pp. 239-260
- Ahlvik, P., Ntziachristos, L., Keskinesn, J. and Virtanen, A., 1998, 'Real Time Measurements of Diesel Particle Size Distribution with an Electrical Low Pressure Impactor,' SAE Technical Paper 980410
- van Gulijk, C., Schouten, J. M., Marijnissen, J. C. M., Makkee, M. and Moulijn, J. A., 2001, 'Restriction for the ELPI in Diesel Particulate Measurements,' J. Aerosol Sci., Vol. 32, pp. 1117-1130 https://doi.org/10.1016/S0021-8502(01)00045-3
- Marjamaeki, M., Keskinen, J., Chen, D. R. and Pui, D. Y. H., 2000, 'Performance Evaluation of the Electrical Low-Pressure Impactor(ELPI),' J. Aerosol Sci., Vol. 31, No. 2, pp. 249-261 https://doi.org/10.1016/S0021-8502(99)00052-X
- Hillamo, R. E. and Kauppinen, E. I., 1991, 'On the Performance of the Berner Low Pressure Impactor,' Aerosol Sci. Technol, Vol. 14, pp. 33-47 https://doi.org/10.1080/02786829108959469
- Ji, J. H., Cho, M. H., Bae, G. N. and Hwang, J., 2004, 'Design and Performance Evaluation of a Low Pressure Impactor for Sampling Submicron Aerosols,' Trans. KSME B, Vol. 28, No. 3, pp. 349-358 https://doi.org/10.3795/KSME-B.2004.28.3.349
- Cho, M. H., Ji, J. H., Park, D. H., Bae, G. N. and Hwang, J., 2004, 'Design and Performance Evaluation of a Diode Type Corona Charger for Real Time Measurement of The Submicron Aerosol,' Trans. KSME B, Submitted https://doi.org/10.3795/KSME-B.2004.28.9.1066
- Flagan, R. C., 1982, 'Compressible Flow Inertial Impactors,' J. Coll. Interface Sci., Vol. 87, pp. 291-299 https://doi.org/10.1016/0021-9797(82)90390-3
- Biswas, P.and Flagan, R. C., 1984, 'High Velocity Inertial Impactors,' Envir. Sci. Technol., Vol. 18, pp. 611-616 https://doi.org/10.1021/es00126a009
- Hering, S. V., Flagan, R. C. and Friedlander, S. K., 1978, 'Design and Evaluation of New Low Pressure Impactor. 1.,' Envir. Sci. Technol., Vol. 12, pp. 667-673 https://doi.org/10.1021/es60142a004
- Bae, G. N., Ji, J. H. and Moon, K. C., 1999, 'Collection Characteristics of a MOUDI Cascade Impactor for Coarse Particles,' J. Korea Air Pollution Research Association, Vol. 15, No. 6, pp. 799-804
- Ji, J. H., Bae, G. N. and Hwang, J., 2001, 'Design and Performance Evaluation of a Three Stage Impactor,' Korean Society for Atmospheric Environment, Vol. 17, No. 6, pp. 441-450
- Ji, J. H., 2003, 'Change of Particle Size Distribution Using Corona Discharge and Classifying Characteristics of Charged Particles,' Ph.D. Thesis, Yonsei University
- Ji, J. H., Bae, G. N. and Hwang, J., 2003, 'Nano Particle Charging Characteristics of Aerosol Charge Neutralizers,' Trans. KSME B, Vol. 27, pp. 1489-1497 https://doi.org/10.3795/KSME-B.2003.27.10.1489
- Ji, J. H., Bae, G. N. and Hwang, J., 2003, 'Effect of Performance of Aerosol Charge Neutralizers on the Measurement of Highly Charged Particles Using a SMPS,' Trans. KSME B, Vol. 27, pp. 1498-1507 https://doi.org/10.3795/KSME-B.2003.27.10.1498