• Title/Summary/Keyword: DISCHARGE

Search Result 13,065, Processing Time 0.038 seconds

The Design of a patch Sensor for Partial Discharge diagnosis in Rotating Machine Stator Windings (회전기 고정자 권선의 부분방전 진단을 위한 평면 Patch Sensor 설계)

  • Yang, Sang-Hyun;Lim, Kwang-Jin;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.97-98
    • /
    • 2008
  • In 6.6kV Rotary Machine Stator Windings, Corona Discharge, Discharge at Conductor Surface, Slot Discharge and Endwinding Discharge is happended by electronic degradation. Also, if Partial Discharge cause in inner-part of Rotary Machine Stator Windings, it will be happended voltage and current pulse. In case of discharge spark, RF electromagnetic wave, which transmits at discharge position, can happen. To detect this kind of RF electromagnetic wave efficiently, we have designed Planar Antenna Sensor with the CST MWS simulation program. Also we have confined the application possibility, which can analyzes the partial discharge in Rotary Machine Stator Windings. In the Future, sample of planar antenna sensor will be able to compare with the data of simulation by CST MWS program.

  • PDF

A Study of Flexible BLU Using Plasma Discharge Ouster (플라즈마 방전 클러스터를 이용한 플렉시블 백라이트 유닛 연구)

  • Ryu, Si-Hong;Koo, Kyo-Uk;Lee, Seong-Eui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.324-325
    • /
    • 2008
  • In this Study, We fabricated a plasma discharge cluster with external electrodes which can be applied to flexible backlight in a polymer substrate and investigated the discharge characteristics. The Sealing process was progressed in vacuum chamber, which enable to fabricate plasma discharge cluster. The results of discharge characteristics show that the static memory margin of plasma discharge cluster was increased, as Ne/Xe(5%) gas pressure was increased. also, When gas pressure was 100torr at 600um of electrode gap, we have obtained high luminance of a plasma discharge cluster.

  • PDF

A Study on the Characteristics to working Condition of STD11 in Wire-Cut EDM (Wire-Cut EDM에서 가공조건에 따른 STD11의 가공특성에 관한 연구)

  • Lee, Hong-Gil;Kim, Won-Il;Lee, Yun-Kyung;Wang, Duk-Hyun;Kim, Jong-Up
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.4 no.3
    • /
    • pp.5-12
    • /
    • 2005
  • In wire discharge machining which is using STD 11 as die materials, the major factors of machining speed are discharge voltage, discharge current, and discharge time. All of the three factors give the effect. Increasing of the discharge pulse time gets groove width wider and it relatively increases surface roughness and clearance. If no load voltage is decreased, surface roughness is good but it decreases machining speed. If on time is increased, machining speed will get faster and clearance and offset value also get bigger.

  • PDF

A Study on Degradation Properties of Silicone Cable due to Partial Discharge (부분 방전에 의한 실리콘 케이블의 열화 특성에 관한 연구)

  • Lee, Sung Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.1
    • /
    • pp.34-39
    • /
    • 2015
  • In this study, the characteristics of partial discharge was measured for the four core silicone cable (0.6/1.0 kV, $1.0SQ{\times}4C$) with insulated part of 15 cm and conductor of 1cm. The following results have been confirmed as a result of this study. When the first line of cable is connected to the positive electrode and the second, third line of cable is connected to the negative electrode, it found that the inception voltage and extinction voltage decreased with increasing the line of negative electrode, and the partial discharge charge quantity(Q) increases, while the number of discharge occurrence has decreased. The inception voltage and extinction voltage of partial discharge has decreased with increasing the degradation rate in the 33%, 67%, 100%. Also, it confirmed that the partial discharge charge quantity(Q) and the number of discharge occurrence has decreased.

The Design of a Planar Antenna Sensor for Partial Discharge diagnosis in 6.6kV Rotary Machine Stator Windings (6.6kV 회전기 고정자 권선에서 부분방전 진단을 위한 평판 안테나 센서 설계)

  • Lim, Kwang-Jin;Lwin, Kyaw-Soe;Shin, Dong-Hoon;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.222-223
    • /
    • 2007
  • In 6.6kV Rotary Machine Stator Windings, Corona Discharge, Discharge at Conductor Surface, Slot Discharge and Endwinding Discharge is happended by electronic degradation. Also, if Partial Discharge cause in inner-part of Rotary Machine Stator Windings, it will be happended voltage and current pulse. In case of discharge spark, RF electromagnetic wave, which tranmits at discharge position, can happen. To detect this kind of RF electromagnetic wave efficiently, we have designed Planar Antenna Sensor with the CST MWS simulation program. Also we have confined the application possibility, which can analize the partial discharge in Rotary Machine Stator Windings. In the Future, sample of planar antenna sensor will be able to compare with the data of simulation by CST MWS program.

  • PDF

Estimation of River discharge using Very High-Resolution Satellite Data in Yangtze River

  • Zhang, Jiqun;Xu, Kaiqin;Watanabe, Masataka;Sun, Chunpeng
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.728-733
    • /
    • 2002
  • The measurement of river discharge is among the most fundamental observations and is necessary for understanding many water-related issues, such as flooding hazards, sediment transportation, and nutrient movement. Traditionally river discharge is estimated by measuring the water stage and converting the measurement to discharge using a stage-discharge rating curve. The possibility of monitoring river discharge from satellites has been largely ignored, because it is difficult to measure water surface information from space with sufficient precision. In this paper, an efficient approach to discharge estimation using mainly satellite data is developed and described. The proposed method, which focuses on the measurement of water-surface width coupled with river width-stage and stage-discharge relationships, is applied to the Yangtze River with good results.

  • PDF

Characteristics of Ultra High Frequency Partial Discharge Signals from Metallic Particle Defected Oil-paper Insulation in Transformer (변압기 절연지 표면 금속 이물질 방전에 의한 극초단파 신호특성)

  • Yoon, Jin-Yul;Ju, Hyung-Jun;Goo, Sun-Geun;Park, Ki-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.10
    • /
    • pp.879-883
    • /
    • 2009
  • This paper was provided to help in detecting defects in power transformer. For this purpose, a partial discharge cell was designed and manufactured as a discharge source to simulate particle defected paper-oil insulation in power transformer. Experimental set-up for measuring PD signals was described. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and pattern of PRPD(Phase Resolved Partial Discharge) of partial discharge signals were examined and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the substation faults.

Determination of Parameters for 3-Dimensional Electrical Discharge Machining by a Tool Electrode Surface (공구전극곡면에 의한 3차원 방전가공조건의 결정)

  • 주상윤;이건범
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.27-33
    • /
    • 2000
  • This paper presents a method for determining machining parameters in 3-dimentional electrical discharge machining(EDM). The parameters are the peak value of currents, the pulse-on time, and the pulse-off time. It is known that they influence the performance of EDM more than the other else. The parameters are determined from the discharge area between a tool electrode and a work piece. The discharge area is directly influenced by the geometry of a tool surface and the tool discharge position. The discharge area on a tool discharge position is calculated from intersection curves between the tool surface and a horizontal plane. The grid search method is applied to determine the intersection curves. An example is introduced to show that the machining parameters are obtained from the surface geometry of a tool electrode.

  • PDF

The Effects of a Home-Visiting Discharge Education on Maternal Self-esteem, Maternal Attachment, Postpartum Depression and Family Function in the Mothers of NICU Infants

  • Ahn Young-Mee;Kim Mi-Ran
    • Journal of Korean Academy of Nursing
    • /
    • v.34 no.8
    • /
    • pp.1468-1476
    • /
    • 2004
  • Purpose: A quasi-experimental study was performed to investigate the effects of a home visiting discharge education program on the maternal self-esteem, attachment, postpartum depression and family function in 35 mothers of neonatal intensive care unit (NICU) infants. Methods: Twenty-three mothers in the intervention group received the home visiting discharge education while 12 mothers in the control group received the routine, hospital discharge education. Baseline data was collected in both groups one day after delivery. The intervention group received the home visiting discharge education while the control group did the routine hospital-based discharge education. The questionnaire including the data on maternal self-esteem, attachment, postpartum depression and family function were collected within 1 week after the discharge by mail. Results: The scores of maternal self-esteem, and attachment were significantly increased, and the postpartum depression and the family function score were decreased after the home visiting discharge education in intervention group. There were no changes in these variables before and after the routine hospital-based discharge education in control group. Conclusion: These results support the beneficial effects of home visiting discharge education on the maternal role adaptation and family function of the mothers of NICU infants.

The Effects of Discharge Planning for the Elderly with Pulmonary Disease in the Emergency Room (퇴원계획중재가 응급실 내원 호흡기 질환 노인의 퇴원준비도, 간호서비스 만족도, 재입원율에 미치는 효과)

  • Kim, Hyeon-Ju;Park, Yeon-Hwan
    • Journal of Korean Critical Care Nursing
    • /
    • v.7 no.1
    • /
    • pp.24-32
    • /
    • 2014
  • Purpose: The purpose of this study was to examine the effects of discharge planning on patient satisfaction, the readmission rate and preparedness for discharge in the elderly admitted to the emergency room (ER) for pulmonary disease. Methods: A quasi-experimental intervention study design was used. Older adults with pulmonary health problems in the ER in one general hospital were randomly allocated to either an experimental (n=21, 74.2 years) or control group (n=19, 70.7 years). The experimental group participated in a discharge planning program by a geriatric nurse practitioner. Data were collected from medical records, physical measurements and structured questionnaires including information on demographics, patient satisfaction, readmission, and preparedness for discharge. Results: Participants in the experimental group had significantly better outcomes with regard to patient satisfaction with nursing services (p=.003) and preparedness for discharge (p=.034). However, there was no significant effect on the readmission rate (p=.392) Conclusion: The results suggested that a discharge planning program could bolster nursing service satisfaction and preparedness for discharge in older patients admitted to the ER for pulmonary health problems. To clarify the effects of discharge planning on older patients admitted to the ER, a larger sample population, better instruments for various measures, a new manual on discharge planning and frequent follow-up will be necessary.

  • PDF