• Title/Summary/Keyword: DICOM 파일

Search Result 55, Processing Time 0.022 seconds

Produced Body Customized 3D Print Finger Brace using Dicom File (Dicom file을 이용하여 만든 신체 맞춤형 3D print 손가락 보조기 제작)

  • Choi, Hyeun-Woo;Park, Ji-Eun;Kim, Jung-Hun;Seo, An-Na;Lee, Jong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.597-603
    • /
    • 2019
  • We obtained a Dicom file using a CT (Computed Tomography), a diagnostic test device used in clinical practice. Dicom files and 3D programs, and finger printers with 3D printers. Because the finger brace is intended for the human body, the accuracy of the shape is very important. 3D Print has the advantage of high precision, variety of materials, and short output time. In clinic, aluminum protector or medical device manufacturer's finger protector is limited. By creating a finger brace with a 3D printer, we expect to be able to apply a precise form of a custom finger brace to the patient that can be used to treat a patient's finger trauma, illness, or deformity.

Calculation of Dose Distribution for SBRT Patient Using Geant4 Simulation Code (Geant4 전산모사 코드를 이용한 SBRT 환자의 선량분포 계산)

  • Kang, Jeongku;Lee, Jeongok;Lee, Dong Joon
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.36-41
    • /
    • 2015
  • The Monte Carlo based dose calculation program for stereotactic body radiotherapy was developed in this study. The Geant4 toolkit widely used in the radiotherapy was used for this study. The photon energy spectrum of the medical linac studied in the previous research was applied for the patient dose calculations. The geometry of the radiation fields defined by multi-leaf collimators were taken into account in the PrimaryGeneratorAction class of the Geant4 code. The total of 8 fields were demonstrated in the patient dose calculations, where rotation matrix as a function of gantry angle was used for the determination of the source positions. The DicomHandler class converted the binary file format of the DICOM data containing the matrix number, pixel size, endian type, HU number, bit size, padding value and high bits order to the ASCII file format. The patient phantom was constructed using the converted ASCII file. The EGSnrc code was used to compare the calculation efficiency of the material data.

Development of Monte Carlo Simulation Code for the Dose Calculation of the Stereotactic Radiosurgery (뇌 정위 방사선수술의 선량 계산을 위한 몬테카를로 시뮬레이션 코드 개발)

  • Kang, Jeongku;Lee, Dong Joon
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.303-308
    • /
    • 2012
  • The Geant4 based Monte Carlo code for the application of stereotactic radiosurgery was developed. The probability density function and cumulative density function to determine the incident photon energy were calculated from pre-calculated energy spectrum for the linac by multiplying the weighting factors corresponding to the energy bins. The messenger class to transfer the various MLC fields generated by the planning system was used. The rotation matrix of rotateX and rotateY were used for simulating gantry and table rotation respectively. We construct accelerator world and phantom world in the main world coordinate to rotate accelerator and phantom world independently. We used dicomHandler class object to convert from the dicom binary file to the text file which contains the matrix number, pixel size, pixel's HU, bit size, padding value and high bits order. We reconstruct this class object to work fine. We also reconstruct the PrimaryGeneratorAction class to speed up the calculation time. because of the huge calculation time we discard search process of the ThitsMap and used direct access method from the first to the last element to produce the result files.

Marking network connections by DICOM & PACS

  • Kim, Gwang-Yeol;Lee, An-Bae;Park, Dong-Hun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.3 no.1
    • /
    • pp.72-73
    • /
    • 1997
  • Medical imaging device에서 이미지 정보의 교환은 PACS의 성공을 결정짓는 중요한 요소이다. 즉 이미지 정보를 획득한다는 것은 네트워크상에서 정보를 신속 정확히 얻을 수 있다는 장점을 말한다. 더욱 중요한 것은 이미지파일의 호환성이다. 의료영상저장전달시스템 즉 PACS는 병원의 모든 정보와 서로 연동될 수 있어야 한다. 데이타 통합과 시스템의 안정성은 PACS에 있어서 가장 중요한 필수요건이다. 위에 언급한 요구조건들을 모두 만족시키기 위해서는 시스템 상호간을 네트워크할 수 있는 공통의 통합 프로토콜이 필요하다. 이와같은 문제를 해결하기 위해서 The American College of Radiology(ACR)과 National Electrical Manufacturers Association(NEMA)는 1983년초에 업체간의 장비공유와 방사선 실무자들의 통합되는 프로토클을 제정하기 위해 위원회를 설립하였다. 여기서 제정된 프로토콜을 DICOM이라 정하였다. DICOM의 역사적 배경, 의미, 필요성과 시스템상에서 어떻게 역활해왔는가와 DICOM을 통한 PACS시스템의 실제 활용예에 대하여 알아보겠다.

  • PDF

Implementation of Intelligent Medical Image Retrieval System HIPS (지능형 의료영상검색시스템 HIPS 구현)

  • Kim, Jong-Min;Ryu, Gab-Sang
    • Journal of Internet of Things and Convergence
    • /
    • v.2 no.4
    • /
    • pp.15-20
    • /
    • 2016
  • This paper describes the construction of knowledge data retrieval management system based on medical image CT. The developed system is aimed to improve the efficiency of the hospital by reading the medical images using the intelligent retrieval technology and diagnosing the patient 's disease name. In this study, the medical image DICOM file of PACS is read, the image is processed, and feature values are extracted and stored in the database. We have implemented a system that retrieves similarity by comparing new CT images required for medical treatment with the feature values of other CTs stored in the database. After converting 100 CT dicom provided for academic research into JPEG files, Code Book Library was constructed using SIFT, CS-LBP and K-Mean Clustering algorithms. Through the database optimization, the similarity of the new CT image to the existing data is searched and the result is confirmed, so that it can be utilized for the diagnosis and diagnosis of the patient.

Monte Carlo Simulation for absorbed dose in PMMA phantom during the low-energy X-ray irradiation (저 에너지 X선 조사 시 PMMA 팬텀 내의 흡수선량 평가를 위한 몬테카를로 시뮬레이션)

  • Kim, Sang-Tae;Kang, Sang-Koo;Kim, Chong-Yeal
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.383-389
    • /
    • 2011
  • This study offered a new method to calculate absorbed dose of actual patients through Monte Carlo Simulation by using the linkage of Geant4 and DICOM, and, the experimental value of absorbed dose at the center and Geant 4 simulation result according to the depth of PMMA mock phantom were compared by using MOSEF in order to verify Geant4 calculation code. In the area where there was no air space between the irregular gap due to incomplete compression of PMMA slab, the differences were $0.46{\pm}4.69$ percent and $-0.75{\pm}5.19$percent in $15{\times}15cm^2$ and $20{\times}20cm^2$ respectively. Excluding the error due to incomplete compression of PMMA mock phantom, the calculation values of the Monte Carlo simulation by linkage of Geant4 and DICOM was the same.

A Novel Modeling Method for Manufacturing Hearing Aid Using 3D Medical Images (3차원 의료영상을 이용한 보청기 제작의 새로운 모델링 방법)

  • Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.257-262
    • /
    • 2016
  • This study aimed to suggest a novel method of modeling a hearing aid ear shell based on Digital Imaging and Communication in Medicine (DICOM) in the hearing aid ear shell manufacturing method using a 3D printer. In the experiment, a 3D external auditory meatus was extracted by using the critical values in the DICOM volume images, and the modeling surface structures were compared in standard type STL (STereoLithography) files which could be recognized by a 3D printer. In this 3D modeling method, a conventional ear model was prepared, and the gaps between adjacent isograms produced by a 3D scanner were filled with 3D surface fragments to express the modeling structure. In this study, the same type of triangular surface structures were prepared by using the DICOM images. The result showed that the modeling surface structure based on the DICOM images provide the same environment that the conventional 3D printers may recognize, eventually enabling to print out the hearing aid ear shell shape.

Development of Integration Protocol of Nuclear Medicine Image with A Commercial PACS (핵의학 영상을 상용 PACS에 연동 전송하는 프로토콜 개발)

  • Im, Ki-Chun;Choi, Yong;Park, Jang-Chun;Song, Tae-Yong;Choi, Yeon-Sung;Lee, Kyung-Han;Kim, Sang-Eun;Kim, Byung-Tae
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.431-436
    • /
    • 2002
  • The purpose of this study was to develop an integration protocol of Nuclear Medicine image with a commercial PACS. Two independent local networks. PACS network and Nuclear Medicine network, were connected using a Nuclear Medicine DICOM gateway A DICOM converter Program was developed to convert Interfile 3.3. which is used in nuclear medicine scanners in our hospital. to DICOM 3.0. The Program converts Interfile format images to those of DICOM format and also transfers converted DICOM files to PACS DICOM gateway. PACS DICOM gateway compares and matches the DICOM image information with patient information in Hospital Information System and then saves to PACS database. The transfer protocol was designed to be able to transfer Interfile. screen dumped file. and also scanned file. We successfully transferred Nuclear Medicine images to PACS. Images transferred by Interfile transfer protocol could be further processed using various tools in PACS. The graphs, numerical information and comments could be conveniently transferred by screen dumped file. The image in a hard copy can be transferred after scanning using an ordinary scanner. The developed protocol can easily transfer Nuclear Medicine images to PACS in various forms with low cost.

Medical Information Processing System based on Wireless Network using RFID (RFID를 이용한 무선 네트워크 기반 의료정보처리 시스템)

  • Kim, Jae-Joon;Cho, Kyu-Cheol;Kim, Jong-Wan
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.11 no.4
    • /
    • pp.1-9
    • /
    • 2006
  • The general medical information service in hospital recently has been turned into ubiquitous environment. A key requirement in ubiquitous environment is the ability for communication between image viewer realized by DICOM standard and a server supporting medical information to make it possible. In order to apply the proposed scheme, we first realized the server/client networking in mobile terminal environment. Second, we realized DICOM viewer using a PDA to be capable of wireless communication in ubiquitous environment. Third, MIPS(Medical Information Processing System) utilized RFID system to apply the patient's information efficiently. In particular, it showed the capability to communicate image based system unlike previous text based communication.

  • PDF

Effect of the STereoLithography File Structure on the Ear Shell Production for Hearing Aids According to DICOM Images (DICOM 영상에 의한 STL 파일 구조가 보청기 이어 쉘 제작에 미치는 영향)

  • Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.121-126
    • /
    • 2017
  • A technique for producing the ear shell for a hearing aid using DICOM (Digital Imaging and Communication in Medicine) image and a 3D printing was studied. It is a new application method, and is an application technique that can improve the safety and infection of hearing aid users and can reduce the production time and process stages. In this study, the effects on the shape surface were examined before and after the printing of the ear shell using a 3D printer based on the values obtained from the raw data of the DICOM images at the volumes of 0.5 mm, 1.0 mm, and 2.0 mm, respectively. Before the printing, relative relationship was compared with respect to the STL (STereoLithography) file structure; and after the printing, the intervals of the layered structure of the ear shell shape surface were compared by magnifying them using a microscope. For the STL file structure, the numbers of triangular vertices, more than five intersecting points, and maximum intersecting points were large in the order of 0.5 mm, 1.0 mm, and 2.0 mm, respectively; and the triangular structure was densely distributed in the order of the bending, angle, and crest regions depending on the sinuosity of the external auditory meatus shape. As for the ear shell shape surface examined by the digital microscope, the interval of the layered structure was thick in the order of 2.0 mm, 1.0 mm, and 0.5 mm. For the STL surface structure mentioned above, the intersecting STL triangular structure was denser as the sinuosity of the 3D ear shell shape became more irregular and the volume of the raw data decreased.