• Title/Summary/Keyword: DIAL system

Search Result 67, Processing Time 0.025 seconds

AAA System for PLMN-WLAN Internetworking

  • Janevski Toni
    • Journal of Communications and Networks
    • /
    • v.7 no.2
    • /
    • pp.192-206
    • /
    • 2005
  • Integration of mobile networks and Internet has started with 2.5 generation of mobile cellular networks. Internet traffic is today dominant traffic type worldwide. The hanger for higher data rates needed for data traffic and new IP based services is essential in the development of future wireless networks. In such situation, even 3G with up to 2 Mbit/s has not provided data rates that are used by Internet users with fixed broadband dial-up or through wired local area networks. The solution to provide higher bit rates in wireless access network has been found in wireless LAN although initially it has been developed to extend wired LAN into wireless domain. In this paper, we propose and describe a solution created for interoperability between mobile cellular network and WLAN. The integration between two networks, cellular and WLAN, is performed on the authentication, authorization, and accounting, i.e., AAA side. For that purpose we developed WLAN access controller and WLAN AAA gateway, which provide gateway-type access control as well as charging and billing functionalities for the WLAN service. In the development process of these elements, we have considered current development stadium of all needed network entities and protocols. The provided solution provides cost-effective and easy-to-deploy PLMN-WLAN Internetworking scenario.

Residual Life Assessment on Cast Iron Pipes of Water Distribution System (상수도관로중 주철관종의 잔존수명 평가에 관한 연구)

  • Lee, Hyun-Dong;Bae, Chul-Ho;Hong, Seong-Ho;Hwang, Jae-Woon;Kwak, Phill-Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.3
    • /
    • pp.206-214
    • /
    • 2004
  • Residual wall thicknesses, corrosion rates, and residual life of thirty four samples of cast iron pipes(CIPs) and ductile cast iron pipes(DCIPs) collected from water mains of B city were studied to estimate their remaining service life or optimum time of rehabilitation. The internal maximum corrosion depths of samples measured using a dial gauge after shot blasting were twice higher than the external in most cases. Therefore corrosion of water pipes was much more affected by internal water quality than soil. Residual wall thicknesses of DCIPs were higher than those of CIPs. That reason was thought to be that DCIPs have been protected from internal corrosion by lining cement mortar. Residual life calculated by maximum corrosion rate was ranged up to 44 years with 12.40 years average. Since most CIPs were much deteriorated, rehabilitation plan should be established soon in B city. Residual life of DCIP was 33.52 years average. When cement mortar lining is used up by neutralization of DCIPs. DCIP also should be rehabilitated.

Attentive Knowledge Selection Model for Knowledge-Grounded Multi-turn Dialogue System (지식 기반 다중 대화 시스템을 위한 주의 집중 지식 선택 모델)

  • Lee, Dohaeng;Jang, Youngjin;Huang, Jin-Xia;Kwon, Oh-Woog;Kim, Harksoo
    • Annual Conference on Human and Language Technology
    • /
    • 2021.10a
    • /
    • pp.361-364
    • /
    • 2021
  • 지식 기반 다중 대화 시스템은 지식 정보를 포함한 응답을 생성하는 대화 시스템이다. 이 시스템은 응답 생성에 필요한 지식 정보를 찾아내는 지식 선택 작업과 찾아낸 지식 정보를 바탕으로 문맥을 고려한 응답을 생성하는 응답 생성 작업으로 구성된다. 본 논문에서는 지식 선택 작업을 기계독해 프레임워크에 적용하여 해결하는 방법을 제안한다. 지식 선택 작업은 여러 개의 발화로 이루어진 대화 기록을 바탕으로 지식 문서 내에 존재하는 지식을 찾아내는 작업이다. 본 논문에서는 대화 기록 모델링 계층을 활용해 마지막 발화와 관련 있는 대화 기록을 찾아내고, 주의 집중 풀링 계층을 활용해 긴 길이의 지식을 효과적으로 추출하는 방법을 제안한다. 실험 결과, 목적지향 지식 문서 기반 대화 데이터 셋인 Doc2dial 데이터의 지식 선택 작업에서 F1 점수 기준 76.52%, EM 점수 기준 66.21%의 성능을 기록해 비교 모델 보다 높은 성능을 기록하는 것을 확인할 수 있었다.

  • PDF

Design of Smart Phone-Based Braille Keyboard System for Visually Impaired People (시각 장애인을 위한 스마트폰 기반 점자형 문자 입력 시스템설계)

  • Eom, Tae-Jung;Lee, Jung-Bae;Kim, Byung-Gyu
    • Convergence Security Journal
    • /
    • v.12 no.1
    • /
    • pp.63-70
    • /
    • 2012
  • Recently, as the smart phone market grows explosively, there exists a large difference of utilization of the smart phone between an usual people and the visually impaired people. In this paper, We propose the character and numer ic input system based on the low cost of braille film and braille for the visually impaired people in order to reduce to information literacy gap for the visually impaired people. The proposed system is designed with the braille film and keyboard layout based on the braille character layout. Additionally, the telephone, the SMS, the abbreviated dial and location transfer function for the emergency situation are designed. The character which inputs using the braille keyboard can be automatically copied in the clip board and used in the other applications. Hence, the visually impaired people can easily use the smart phone for getting plentiful information on the device and network.

Hand-Gesture Dialing System for Safe Driving (안전성 확보를 위한 손동작 전화 다이얼링 시스템)

  • Jang, Won-Ang;Kim, Jun-Ho;Lee, Do Hoon;Kim, Min-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4801-4806
    • /
    • 2012
  • There are still problems have to solve for safety of driving comparing to the upgraded convenience of advanced vehicle. Most traffic accident is by uncareful driving cause of interface operations which are directive reasons of it in controlling the complicate multimedia device. According to interesting in smart automobile, various approaches for safe driving have been studied. The current multimedia interface embedded in vehicle is lacking the safety due to loss the sense and operation capacity by instantaneous view movement. In this paper, we propose a safe dialing system for safe driving to control dial and search dictionary by hand-gesture. The proposed system improved the user convenience and safety in automobile operation using intuitive gesture and TTS(Text to Speech).

A Study on the Implementation of Web Server Patient Monitoring System using Point to Point Protocol (종단 대 종단 프로토콜을 사용하는 웹 서버 환자감시장치 구현에 관한 연구)

  • 최재석;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.463-467
    • /
    • 2000
  • In this paper, we have implemented the Web Server Patient Monitoring System using PPP. It is composed of two parts. The first part is the Analog board for acquiring ECG signals. The second part is the module for processing and transmitting the acquired signal. The second part is using PPP for dial-up networking, TCP/IP for Internet, HTTP for web browser and JAVA program for a Patient Monitoring Program in one chip. In home, it is not need to establish another network line because it uses a telephone line. And a user who want to monitor a patient's biosignal can monitor a patient without wholly open network because it is the network sewer. The Patient Monitoring Program runs on a web browser by downloaded JAVA codes when a user connect to this system. It can make the Home Patient Monitoring Program decrease cost. It can help to avoid the limitation of monitoring a patient.

  • PDF

A Study on the User Interface of Web-based Flexible Manufacturing System (웹기반 유연 생산시스템 사용자 인터페이스)

  • PARK JE-WOONG;KIM WON-JUNG
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.68-72
    • /
    • 2004
  • A practical method to investigate the user interface of web based Flexible Manufacturing System(FMS) on the internet environment is established. Because the industrial FMS controller requires a lot of gadget, such as switch, dial, button, etc., for actual work-site flexible operation sufficiently, the user interface of the controller is significantly complex. The support for operational convenience of FMS controller can increase productivity and efficiency of the user, operational personnel of FMS. While most FMS provide their application programming interface(API) and graphical user interface(GUI) with adequate mechanism itself when used in stand alone, there is increasing demand for FMS that can operate with the intuitional user interface find virtual reality(V/R) environment. This thesis considers the intuitional user interface of Web-based FMS first, and from this, goes a step further, improves as virtual reality environment of FMS on the internet environments by using the feature based modeling technique approach and cartoon rendering. The feature-based modeling technique approach is applied to FMS line which is consist of facilities such as machining center, CNC lathe, autonomous guided vehicle, rail guided vehicle, and various controllers. In this study, the FMS established the intuitional user interface is able to obtain not only the operational convenience but also the enough productivity and significant efficiency.

  • PDF

Development of A Fractionated Stereotactic Radiotherapy System (분할 정위방사선 치료 시스템 개발 연구)

  • 이동한;지영훈;이동훈;조철구;김미숙;유형준;류성렬
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2002
  • We invented the newly developed Fractionated Stereotactic Radiotherapy(F.S.R.T) system using combined techniques of couch mounting and pedestal mounting system. Head fixation frame consists of a milled alluminium alloy(duralumin) and is placed to the couch. This frame immobilized patient head using the dental bite, 3.2 mm frontal and occipital thermoplastic mask. To evaluate the coordinate of target isocenter, Brown-Revert-Walls C.T localizer can be attached to this frame. And also, we developed the frame mounting system by developing the modification of pedestal mounting system. This system is fixed to couch floor and can be used to evaluate the isocenteric accuracy of gantry, couch and collimator in Q.A procedure. In order to measure the relocation accuracy, the acrylic phantom and the accurate pointers have been made. The repositioning of the targets in the phantom were estimated by comparing C.T coordinates and E.C.L portal films taken with anterior-posterior and right-left direction. From the results of experiments, the average distance errors between the target isocenter and its mean position were 0.71$\pm$0.19 for lateral, 0.45$\pm$0.15 for inferior-superior, 0.63$\pm$0.18 for anterior-posterior. And the maximum distance error was less than 1.3 mm. The new head fixation frame and frame mounting system were non-invasive, accurately relocatable, easy to use, very light and well tolerable by the results of phantom tests. The major advantage of using this frame mounting system is complete access to any point in the Patients cranium especially posterior direction

  • PDF

Quality Tests for the Knee-Orthosis Velcro and Locking System (무릎보조기 벨크로 및 잠금장치에 대한 품질시험 연구)

  • Jung, Se-Wook;Seo, Won-San;Cho, KiHun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.275-283
    • /
    • 2016
  • In this study, three knee-orthoses (dial lock type, medium size, right side) were used for a quality level test (static bending test and solidity test of the locking system) of the knee-orthosis locking system. In the static bending test, a smaller maximum load was observed in samples A and C compared to the reference standard value (KS P 8408 standard value: 1000 N, sample A: 865 N, sample C: 833 N). In addition, in the solidity test of the locking system, a smaller maximum load was observed in the all samples compared to the referenced standard value (KS P 8411 standard value: 200 N, sample A: 41 N, sample B: 97 N, sample C: 54 N). Korean industrial standards for knee-orthoses and systematic test methods are lacking. Therefore, a systematic management plan for knee-orthoses is required. The result of the current study showed that a systematic management plan for the knee-orthosis locking system is required. In particular, the development of a quantitative and objective test method is needed. The findings of the current study may be useful for monitoring the quality of the knee-orthosis locking system and may provide foundational information for the development of a quantitative and objective test method.

A Study on Auto Inspection System of Cross Coil Movement Using Machine Vision (머신비젼을 이용한 Cross Coil Movement 자동검사 시스템에 관한 연구)

  • Lee, Chul-Hun;Seol, Sung-Wook;Joo, Jae-Heum;Lee, Sang-Chan;Nam, Ki-Gon
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.11
    • /
    • pp.79-88
    • /
    • 1999
  • In this paper we address the tracking method which tracks only target object in image sequence including moving object. We use a contour tracking algorithm based on intensity and motion boundaries. The motion of the moving object contour in the image is assumed to be well describable by an affine motion model with a translation, a change in scale and a rotation. The moving object contour is represented by B-spline, the position and motion of which is estimated along the image sequence. we use pattern recognition to identify target object. In order to use linear Kalman Filters we decompose the estimation process into two filters. One is estimating the affine motion parameters and the other the shape of moving object contour. In some experiments with dial plate we show that this method enables us to obtain the robust motion estimates and tracking trajectories even in case of including obstructive object.

  • PDF