• Title/Summary/Keyword: DF-100

Search Result 74, Processing Time 0.022 seconds

Fundamental Research on Reactivity of Silica Source in the Rapidly Cured Inorganic Micro-Defect-Free(MiDF) Concrete (촉진 양생한 무기계 MiDF 콘크리트에서 실리카질 원료의 반응성에 관한 기초 연구)

  • Choi, Hong-Beom;Kim, Jin-Man
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.2
    • /
    • pp.166-173
    • /
    • 2019
  • In this paper, the reaction properties of silica source in the accelerated curing conditions using autoclave and the fundamental properties of inorganic Micro Defect Free(MiDF) concrete using silica source are studied. Studies show that Si ions elution rate from silica source in autoclave curing is higher in amorphous source. In tap water conditions, solids which is source after autoclaved curing show a higher mass reduction in amorphous materials, which is attributed to the higher elution rate of ion. In $Ca(OH)_2$ solution conditions, amorphous materials show higher mass increase, due to increase in C-S-H minerals. From experiment for influence on the properties of MiDF concrete by using nano silica materials, the specimen with silica fume shows an increase in compressive strength and a decrease in absorption depending on replacement rate up to 5.5%, while nano silica with amorphous phase and high-fineness shows a decrease in compressive strength and decrease in the water absorption. The specimen with nano silica increases the pore below 10,000nm, but reduces pore between 10,000 and 100,000nm. The above results show that the porosity and absorption rate of MiDF concrete can be reduced by using amorphous nano-size silica. However, to reduce the pore of 50 to 10,000nm, better dispersion of nano material in the cement matrix will be necessary. We will focus on the this item in the next research.

Analysis of Various Honeys from Different Sources Using Electronic Nose (다른 밀원에서 기원한 꿀의 전자코 분석)

  • Hong, Eun-Jeung;Park, Sue-Jee;Lee, Hwa-Jung;Lee, Kwang-Geun;Noh, Bong-Soo
    • Food Science of Animal Resources
    • /
    • v.31 no.2
    • /
    • pp.273-279
    • /
    • 2011
  • Various honeys from different sources were analyzed using an electronic nose based on a mass spectrometer. Various honeys were separated with different mixing ratios. Wild honey and artificial honey were blended at ratios of 100:0, 95:5, 90:10, 85:15, 80:20, 75:25, and 70:30, respectively. Data obtained from the electronic nose were used for discriminant function analysis (DFA). The DFA plot indicated a significant separation of honey from different sources. As the concentration of artificial honey increased, the first discriminant function score (DF1) moved from positive to negative (DF1: $r^2$=0.9962, F=490.6; DF2: $r^2$=0.9128, F=19.44). Furthermore, when acacia honey was mixed with artificial honey and separated with the mixing ratios, the DF scores were: DF1: $r^2$=0.9957, F=396.64; DF2: $r^2$=0.9447, F=29.3. When artificial honey was added to wild honey, it was possible to predict the following equation; DF1= -0.106${\times}$(concentration of artificial honey)+0.426 ($r^2$= 0.96). For acacia honey, the DF1= -0.112${\times}$(concentration of artificial honey)+0.434 ($r^2$=0.968).

Discrimination of Grading Pungency for Red Peppers Spice Using Electronic Nose Based on Mass Spectrometer (고춧가루의 매운 맛 등급화를 위한 Mass Spectrometer를 바탕으로 한 전자코 분석)

  • Kang, Jin Hee;Son, Hee-Jin;Hong, Eun-Jeung;Noh, Bong-Soo
    • Food Engineering Progress
    • /
    • v.14 no.1
    • /
    • pp.35-40
    • /
    • 2010
  • Electronic nose (E-nose) was assessed for grading pungency of powdered red pepper. Complex pretreatments are not required for flavor analysis unlike HPLC or Scoville tests. Mild and pungent taste of powdered red pepper were mixed at various concentrations of 0, 25, 50, 75, and 100%. Those were analyzed using mass spectrometer-based E-nose. Discriminant function analysis (DFA) was conducted on E-nose data. The $R^{2}$ and F-value of dicriminant function first score (DF1) were 0.9946 and 355.65, respectively, when the samples were separated by a relative degree of pungent taste. DF1 value decreased with increasing the amount of powdered red pepper with a pungent taste. It is similar to the increase in the concentration of capsaicin. Increasing the amount of red pepper powder, dicriminant function second score (DF2) values were moved from the negative position into the positive position. The $R^{2}$ and F-value of DF1 were 0.9890, 165.17 and DF2 were 0.9219, 21.64. Also, the results by MS based E-nose agreed to that by HPLC. There is the potential to grade pungent taste of powdered red pepper using the E-nose.

Effects of Temperature and Mass Flux on Deuterium Fluoride Chemical Laser Performance (온도와 질량유속이 불화중수소 화학 레이저 성능에 미치는 영향)

  • Park Byung-Suh;Lee Jung-Hwan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.4 s.19
    • /
    • pp.100-106
    • /
    • 2004
  • The effects of adiabatic flame temperature and mass flux on deuterium fluoride(DF) chemical laser performance were investigated. The power flux and specific power, which are important parameters containing the information of scaling effects of laser device magnitude, and chemical efficiency were selected as a judging parameter of DF laser performance. For the specific power, it was decreased by the increase of power flux of DF laser. Higher the adiabatic flame temperature of atomic fluorine generator, higher the chemical efficiency of DF laser was changed. It seems that the mass flux effect on the chemical efficiency is not remarkable.

Sexual Size Dimorphism in the Red-tongued viper snake(Gloydius ussuriensis) of Population (쇠살모사 개체군의 성적 크기이형)

  • Kim, Byoung-Soo;Oh, Hong-Shik
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.5
    • /
    • pp.542-549
    • /
    • 2014
  • This study was conducted to investigate the body size, sexual size dimorphism (SSD), and related environmental factors between Red-tongued viper snakes (Gloydius ussuriensis) inhabiting two different places, i.e., Jeju Island and its islet Gapado, and to provide data required to maintain species diversity from May, 2006 until June, 2009. The snout-vent length of the Red-tongued viper snake population inhabiting Jeju Island was found to be 242-532 mm ($422.0{\pm}46.7mm$, n = 100) in females and 296-580 mm ($434.5{\pm}51.7mm$, n = 63) in males. In contrast, the snout-vent length was observed to be 205-395 mm ($335{\pm}43.6mm$, n = 55) in female and 215-430 mm ($328{\pm}39.4mm$, n = 73) in male Red-tongued viper snakes inhabiting Gapado. These data demonstrated the snout-vent length of both female and male Red-tongued viper snakes on Jeju Island to be larger than those on Gapado (Female t = 17.343, df = 115, P<0.001; Male = 19.128, df = 101, P<0.001). SSD was measured to be -0.03 in the Red-tongued viper snake population on Jeju Island, with more or less larger sizes in the males, while it was 0.02 in the Red-tongued viper snake population in the Gapado, with a little larger sizes in the females. The reason for this difference in the snake populations between Jeju Island and Gapado may be due to adaption to the different ecological environments. In addition, as SSD, the snout-vent length of the Red-tongued viper snake populations and in young vipers was somewhat higher in the males than in the females on Jeju Island (t = -2.011, df = 117, P<0.05). However, no significant differences were observed in the snout-vent length of the young and the general Red-tongued viper snake populations on Gapa Island. For the population on Jeju island, the head length (F = 6.318, $df_{1,2}$=1,117, P<0.05), head width (F=8.090, $df_{1,2}$=1,117, P<0.01), inter eye length (F=15.898, $df_{1,2}$=1,117, P<0.001), and tail length (F=238.488, $df_{1,2}$=1,111, P<0.001) were all larger in the males, while females showed higher body mass (F=64.111, $df_{1,2}$=1,114, P<0.001). In the case of the Gapa Island population, no significant differences in the head length, head width, and inter eye length between females and males were observed, while the males had a longer tail length (F=168.555, $df_{1,2}$=1,74, P<0.001) and the females were heavier (F=17.812, $df_{1,2}$=1,76, P<0.001). Though no significant differences were found in the head length, head width, and inter eye length, the tail length (F=67.793, $df_{1,2}$=1,72, P<0.001) and body mass (F=4.558, $df_{1,2}$=1,72, P<0.05) were higher in the young male Red-tongued viper snakes than in the females. The snout-vent length, head length, head width, and inter eye length, which did not display SSD in the young Red-tongued viper snake populations, were higher in the male Red-tongued viper snake populations than in the female population from Jeju Island, implying that SSD in the Red-tongued viper snake population on Jeju Island is expressed due to environmental effects during their growth.

An Area-efficient Design of ECC Processor Supporting Multiple Elliptic Curves over GF(p) and GF(2m) (GF(p)와 GF(2m) 상의 다중 타원곡선을 지원하는 면적 효율적인 ECC 프로세서 설계)

  • Lee, Sang-Hyun;Shin, Kyung-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.254-256
    • /
    • 2019
  • 소수체 GF(p)와 이진체 $GF(2^m)$ 상의 다중 타원곡선을 지원하는 듀얼 필드 ECC (DF-ECC) 프로세서를 설계하였다. DF-ECC 프로세서의 저면적 설와 다양한 타원곡선의 지원이 가능하도록 워드 기반 몽고메리 곱셈 알고리듬을 적용한 유한체 곱셈기를 저면적으로 설계하였으며, 페르마의 소정리(Fermat's little theorem)를 유한체 곱셈기에 적용하여 유한체 나눗셈을 구현하였다. 설계된 DF-ECC 프로세서는 스칼라 곱셈과 점 연산, 그리고 모듈러 연산 기능을 가져 다양한 공개키 암호 프로토콜에 응용이 가능하며, 유한체 및 모듈러 연산에 적용되는 파라미터를 내부 연산으로 생성하여 다양한 표준의 타원곡선을 지원하도록 하였다. 설계된 DF-ECC는 FPGA 구현을 하드웨어 동작을 검증하였으며, 0.18-um CMOS 셀 라이브러리로 합성한 결과 22,262 GEs (gate equivalences)와 11 kbit RAM으로 구현되었으며, 최대 100 MHz의 동작 주파수를 갖는다. 설계된 DF-ECC 프로세서의 연산성능은 B-163 Koblitz 타원곡선의 경우 스칼라 곱셈 연산에 885,044 클록 사이클이 소요되며, B-571 슈도랜덤 타원곡선의 스칼라 곱셈에는 25,040,625 사이클이 소요된다.

  • PDF

A STUDY ON THE RELIABILITY OF THE OPTICAL CARIES ACTIVITY TEST (광학적 치아우식활성 검사법의 신뢰도에 관한 연구)

  • Park, Cheol-Hong;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.615-623
    • /
    • 2006
  • The purpose of this study was to evaluate the specificity, sensitivity, and diagnostic power of caries activity test using LED fluorescence. The subjects of this study were 55 children of $6{\sim}7$ years old. LED light were irradiated to labial or buccal surface of all teeth. Fluorescence from initial carious lesion of teeth illuminated by an LED light was observed through barrier filter and the number of teeth showing lesion, size and position of lesion were counted. Streptococcus mutans colony counting and dDfFtT rate test were also done and their correlation was compared. And then specificity, sensitivity, diagnostic power of optical caries activity test using LED light were evaluated. 1. There was positive $correlation({\gamma}=0.43)$ between LED fluorescence test and Streptococcus mutans count(P<0.05). 2. When visual examination was defined to standard testing method, the specificity, sensitivity, diagnostic power of LED fluorescence test were 100%, 76.1%, and 100%. 3. When dDfFtT rate was defined to standard testing method, the specificity, sensitivity, diagnostic power of LED fluorescence test were 88.9%, 47.8%, and 95.7%. 4. When S. mutans colony counting was defined to standard testing method, the specificity, sensitivity, diagnostic power of LED fluorescence test were 100%, 58.7%, and 100%. Considering the above results, optical caries activity test using LED light could be regarded as a practical method because of its close relationship with microbiological caries activity test.

  • PDF

Estimating design floods based on bivariate rainfall frequency analysis and rainfall-runoff model (이변량 강우 빈도분석과 강우-유출 모형에 기반한 설계 홍수량 산정 방안)

  • Kim, Min Ji;Park, Kyung Woon;Kim, Seok-Woo;Kim, Tae-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.10
    • /
    • pp.737-748
    • /
    • 2022
  • Due to the lack of flood data, the water engineering practice calculates the design flood using rainfall frequency analysis and rainfall-runoff model. However, the rainfall frequency analysis for arbitrary duration does not reflect the regional characteristics of the duration and amount of storm event. This study proposed a practical method to calculate the design flood in a watershed considering the characteristics of storm event, based on the bivariate rainfall frequency analysis. After extracting independent storm events for the Pyeongchang River basin and the upper Namhangang River basin, we performed the bivariate rainfall frequency analysis to determine the design storm events of various return periods, and calculated the design floods using the HEC-1 model. We compared the design floods based on the bivariate rainfall frequency analysis (DF_BRFA) with those estimated by the flood frequency analysis (DF_FFA), and those estimated by the HEC-1 with the univariate rainfall frequency analysis (DF_URFA). In the case of the Pyeongchang River basin, except for the 100-year flood, the average error of the DF_BRFA was 11.6%, which was the closest to the DF_FFA. In the case of the Namhangang River basin, the average error of the DF_BRFA was about 10%, which was the most similar to the DF_FFA. As the return period increased, the DF_URFA was calculated to be much larger than the DF_FFA, whereas the BRFA produced smaller average error in the design flood than the URFA. When the proposed method is used to calculate design flood in an ungauged watershed, it is expected that the estimated design flood might be close to the actual DF_FFA. Thus, the design of the hydrological structures and water resource plans can be carried out economically and reasonably.

Fauna and geographical distribution of house dust mites in Korea (한국내 집먼지진드기의 지역분포상)

  • 이한일;전성후
    • Parasites, Hosts and Diseases
    • /
    • v.35 no.1
    • /
    • pp.9-17
    • /
    • 1997
  • During the period of 1933-1994, house dusts were collected from 65 homes at 10 different localities by operating electric vacuum cleaners. House dust mites were isolated from 10 g dust by applying the modified wet sieving method. Total 7,257 mites were collected and 23 species were identified. Among them, Demctophqgoines loyinaf (DF) was predominant (65. Soy) of the total) , followed by D. pteronvssinus (DP) (20.6%) and Tyrophagus nutrescentios (TP) (6.5%) . Rhizoglvphur robini, Sancqsscnin phvIlophogiann, Cheyletus trcussarti and Scheloribates latipes were the first findings from Korea. DF was predominant in Seoul (66.8%), Kwangju (63.6%), inland of Pusan (79.6%1, Inchon (96.5%), Taejon (83.9%), Chouju (87.15) and Chongiu (95.2%), whereas DP was predominant in Yongkwang-ub (72.5%) and Yongdo (island) of Pusan (64.9%), and TP in Chunchon (38.2%) The localities where DP and TP were predominant showed higher relative humidity in air (> 73% RH) . Among 62 study homes, DF, DP and TP were found in 24.6% of the homes, co-habitat of two species in 48.1% and one species in 27.3%. DF was predominant in 63.5% of the homes studied, DP in 29.6% and TP in 6.9%. In 10 g of the house dust, less than 99 mites were found in 49 homes (70.0%), 100-499 mites in 11 homes (15.7%), 500-999 mites in 3 homes (4.3%) and more than 1,000 mites in 2 homes (2.9%). No mite was found in 5 homes (7.1%). In order to evaluate environmental factors affecting the population density of house dust mites, house type, age of house construction, size of the house, number of the family and frequency of the cleaning were compared with the number of mites, and none of the above factors were statistically correlated with the mite density.

  • PDF

Displacement of Dongducheon and Wangsukcheon Fault Observed by Gravity Field Interpretation (중력장 해석으로 관측된 동두천 및 왕숙천 단층의 변위)

  • Sungchan Choi;Sung-Wook Kim;Eun-Kyeong Choi;Younghong Shin
    • Economic and Environmental Geology
    • /
    • v.57 no.1
    • /
    • pp.73-81
    • /
    • 2024
  • To estimate the tectonic displacement of the Chugaryeong Fault System (CFS), gravity surveys were conducted along the Dongducheon fault (DF) and the Wangsukcheon fault (WF). A total of 1,100 stations for the DF and WF regions have been added to the current gravity database. The results of the gravity interpretation indicate that (1) the dextral displacement of the DF is about 3,000 m, similar to the tectonic displacement (2,900-3,100 m) shown in the geological map. (2) The dextral displacement of the WF is about 3,200 m. (3) Taken together, the tectonic displacement of the CFS is estimated to be about 3,000 m on average. To investigate more accurate tectonic displacement of the CFS, further gravity surveys is planned for the Pocheon fault, Gyeonggang fault, and Inje fault.