• Title/Summary/Keyword: DETERIORATION TYPE

Search Result 511, Processing Time 0.028 seconds

Development of auto-tuning algorithm for considering aging effect of wind turbine generator (풍력발전기의 경년화를 고려한 자동튜닝 알고리즘 개발)

  • Kim, Se-Yoon;Kim, Sung-Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.2
    • /
    • pp.246-252
    • /
    • 2012
  • Recently, concern over climate change and global politics associated with traditional fossil fuel energy sources has driven significant increase in wind energy utilization over the past decade around world. Generally, life-time of wind turbine system should be guaranteed for twenty years. Therefore, performance deterioration of wind turbine system occurs owing to aging effects for long term operation. In this work, a new type of auto tuning algorithm for overcoming the problem of performance deterioration is proposed. Furthermore, various simulations are carried out to verify the feasibility of the proposed scheme.

Antioxidant Enzymes in Relation to Oxidative Deterioration of Muscle Foods (근육식품에서 지방산화와 관련된 항산화 효소)

  • Lee, Sung-Ki
    • Food Science of Animal Resources
    • /
    • v.18 no.2
    • /
    • pp.97-106
    • /
    • 1998
  • Antioxidant enzymes such as catalase (CAT), glutathione peroxidase (GSH-Px) and superoxide dismutase (SOD) are known to inhibit oxidative reactions by incativating compounds responsible for the formation of ree radicals. SOD transforms superoxide radical into hydrogen peroxide which is precursor to active free radicals. CAT reduces hydrogen peroxide to water. GSH-Px reduces hydroperoxides to corresponding alcohols. Antioxidant enzyme activities of muscle are different by animal species age, stress and exercise, muscle type and part, conditions of post mortem, storage and processing which are related to oxidative deterioration I muscle foods as well as oxidative defence in living systems. Antioxidant enzyme systems are enhanced rather than weakened in aging skeletal muscle. Red muscle contains higher antioxidant enzyme activity than white muscle. The antioxidant enzyme activities of poultry are higher in leg than in breast, and those of beef are higher in redder and more unstable muscles. It is clear that the effectiveness of the antioxidant enzyme in muscle foods seems to be influenced by meat processing operations. Both GSH-Px and CAT are inactivated by heat processing NaCl also influence the efficiency of the antioxident enzymes since its presence diminishes their catalyitc activity.

  • PDF

Improving Hydraulic System Design by Analysis Model of a Self-propelled Spinach Harvester (자주식 시금치 수확장치 해석모델을 활용한 유압시스템 개선 설계 제안)

  • Noh, Dae Kyung;Lee, Dong Won;Lee, Jong Su;Jang, Joo Sup
    • Journal of Drive and Control
    • /
    • v.19 no.1
    • /
    • pp.69-75
    • /
    • 2022
  • This study aimed to develop solutions for the intermittent performance deterioration of self-propelled spinach harvesters through analysis model. The study was conducted in the following manner. First, changes in performance deterioration and surplus flow, which result from oil temperature changes, were analyzed by simulating actual sequential harvesting movements, which involve driving with actuators operated simultaneously, by analysis model developed in a previous study. Second, fundamental solutions for surplus flow problems were presented. Third, the solutions were applied to a virtual environment to present their practicality and quantitative effects. The two solutions based on the study results were as follows. First, a closed center-type directional control valve was applied to the hydraulic circuit. Second, an unloading system was set up through an on-off solenoid valve.

Association of advanced chronic kidney disease with diabetic retinopathy severity in older patients with diabetes: a retrospective cross-sectional study

  • Geun Woo Lee;Chul Ho Lee;Seong Gyu Kim
    • Journal of Yeungnam Medical Science
    • /
    • v.40 no.2
    • /
    • pp.146-155
    • /
    • 2023
  • Background: Despite the recent increasing trend in the prevalence of type 2 diabetes among older individuals, the relationship between diabetic retinopathy (DR) and chronic kidney disease (CKD) in these patients remains unclear. This study investigated the severity of renal dysfunction according to the degree of DR in older patients with type 2 diabetes. Methods: A total of 116 patients with diabetes and CKD stage ≥3 who visited both the nephrology and ophthalmology outpatient departments between July 2021 and January 2022 were screened. There were 53 patients in the no DR group, 20 in the nonproliferative DR (NPDR) group, and 43 in the proliferative DR (PDR) group. Results: DR severity was related to the deterioration of renal function. The proportion of patients with advanced CKD significantly increased with DR severity (p for trend <0.001). In the multivariate regression model adjusted for age of ≥80 years, male sex, poorly controlled diabetes, macroalbuminuria, insulin use, diabetes duration of ≥10 years, cerebrovascular accident, hypertension, hyperlipidemia, and cardiovascular disease history, the odds ratio compared with the no DR group was approximately 4.6 for the NPDR group and approximately 11.8 for the PDR group, which were both statistically significant (p=0.025 and p<0.001, respectively). Conclusion: DR severity in older patients with diabetes may be associated with deterioration of renal function and high prevalence of advanced CKD. Therefore, periodic examination for DR in older patients with diabetes is important for predicting renal function deterioration and CKD progression.

A Study on Long-time Electrical Treeing Deterioration Properties According to High Frequency Voltage of Epoxy Resin (에폭시수지의 고전압 전원주파수 변화에 따른 장시간 전기적 트리잉 열화 특성연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1571-1577
    • /
    • 2013
  • Electrical tree structure is one of the most important influencing factors for electrical treeing characteristics in polymers. In this paper, we focused on the structure characteristics of electrical treeing in epoxy resins (original) insulation under different high-frequency voltages (60, 500, 1000Hz). Effects of voltage frequency on the ac electrical treeing phenomena in an epoxy resins were carried out in needle-plate electrode arrangement. To measure the treeing initiation and propagation, and the breakdown rate, constant AC of 10 kV with three different voltage frequencies (60, 500 and 1,000 Hz) was applied to the specimen in needle-plate electrode specimen at $30^{\circ}C$ of insulating oil bath. At 60 Hz, the treeing initiation time was 360 min and the propagation rate was $6.85{\times}10^{-4}mm/min$, and the morphology was dense branch type. As the voltage frequency increased, the treeing initiation time decreased and the propagation rate increased. At 1,000 Hz, the treeing initiation time was 0 min and the propagation rate was $7.81{\times}10^{-2}mm/min$, and the morphology was dense bush type.

Manually applied to the social infrastructure polyurea waterproofing materials, methods based on the deterioration of conditions attached Performance Evaluation and Analysis (사회기반시설에 적용되는 수작업형 폴리우레아 방수·방식재료의 열화조건에 따른 부착성능평가 및 분석에 관한 연구)

  • Choi, Eun-Kyu;Kim, Yun-Ho;Lee, Hye-Ryung;Kim, Su-Ryon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.41-42
    • /
    • 2012
  • High temperature / high pressure spray equipment using a conventional method, unlike spray polyurea adjustable pot life and yellowing caused by UV light and chemicals do not occur, or discoloration of Self-Leveling Type of rugged hand-polyurea resin for technology development is underway. This new concept of polyurea resin roller, brush, airless spray, and they installed easily using the unfamiliar labor, and curing time of approximately four hours to gain control of the glass because it is Pot. Construction, but does not like the spray polyurea resin, compared to the existing degradation of the adhesion strength is concerned. In this study, Self-Leveling Type Manual of polyurea resin adhesion strength of target deterioration Let's minimize problems by reviewing existing domestic and infrastructure long-term durability for long life of the facility is to obtain.

  • PDF

Development of the Expert System for Management on Slab Bridge Decks (슬래브교 상판의 전문가 시스템 개발)

  • Ahn, Young-Ki;Lee, Cheung-Bin;Yim, Jung-Soon;Lee, Jin-Wan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.1
    • /
    • pp.267-277
    • /
    • 2003
  • The purpose of this study makes a retrofit and rehabilitation practice trough the analysis and the improvement for the underlying problem of current retrofit and rehabilitation methods. Therefore, the deterioration process, the damage cause, the condition classification, the fatigue mechanism and the applied quantity of strengthening methods for slab bridge decks were analysed. Artificial neural networks are efficient computing techniqures that are widely used to solve complex problems in many fields. In this study, a back-propagation neural network model for estimating a management on existing slab bridge decks from damage cause, damage type, and integrity assessment at the initial stsge is need. The training and testing of the network were based on a database of 36. Four different network models werw used to study the ability of the neural network to predict the desirable output of increasing degree of accuracy. The neural networks is trained by modifying the weights of the neurons in response to the errors between the actual output values and the target output value. Training was done iteratively until the average sum squared errors over all the training patterms were minimized. This generally occurred after about 5,000 cycles of training.

Development of Surface Treatment Systems for Concrete Structures to Extend Service Life (내구수명 증진을 위한 콘크리트 구조물용 표면처리공법 개발)

  • Lee, Chang-Soo;Yoon, In-Seok;Lee, Kyu-Dong;Park, Jong-Hyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.2
    • /
    • pp.255-261
    • /
    • 2002
  • Concrete structures stand in poor surrounding than it has ever been met before, because they are installed in severe conditions such as chloride penetration. $CO_2$ gas, water and so on. Therefore, the countermeasure to efficiently protect from the deterioration of concrete structures should be urgently considered. From this point of view, this study was aimed to develop surface treatment systems for concrete structures, which cover physical properties, long term durability and economic consideration. Developing the optimal surface treatment materials, powder type polymer or liquid type polymer was added to inorganic base materials. Three surface treatment materials which had shown best results in primary tests were selected and durability tests were fulfilled. Consequently optimum surface treatment material was developed. The surface treatment materials, which were developed through this study, can efficiently extend the service life of concrete structures. As a result, the life cycle cost should be reduced and the waste of material resources would be cut down.

A Study on the Environment Planning of Exhibition Space for Conservation of Collection in a Museum (박물관자료의 보존을 위한 전시공간 환경계획에 관한 연구)

  • Jung, Sung-Wook
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.2
    • /
    • pp.91-101
    • /
    • 2008
  • The purpose of this study is to suggest the design guidelines of exhibition space for conservation of collection in a museum. With the purpose of this study, examined the concept and a condition of conservation which is focused on deterioration in a exhibition space, investigated the actual condition of total 42 facilities and analyzed the specific instance which is excellent by factor of environment plan. Hereupon, the results of this study are as follows. First, exhibition space should be equipped with sufficient 'Filtering Space' before the outdoor and located central territory in a museum facility. Second, exhibition space should be partition off an area into the quality of collection, and then controlled by each of them. Third, in consideration of the annual air fluctuation of our country, the database which is adaptable for setting up the standard of temperature and RH must be prepared. Fourth, it is necessary to establish a 'Reference Exhibition Room' which is formed cellular type and a 'Garnering Exhibition Center'. Fifth, for the prevention of deterioration which is generated in exhibition space, the showcase must be high air-tight. Sixth, it is necessary to reduce a inside space of high air-tight showcase. Seventh, art-sorb is suitable for control the organic matter of collection and a except of fiber optics is not suitable for lighting of showcase. Eighth, wall-type showcase should be have air-chamber which is formed like museum storage and run over 8 hours a day.

EWIS Reliability Analysis of Aging Fighter Aircraft through Teardown Inspection (완전분해 점검을 통한 장기운영 전투기 전기배선시스템의 신뢰성분석)

  • Lee, Hoyong
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.26 no.4
    • /
    • pp.116-121
    • /
    • 2018
  • According to the incresement of aging aircraft, Republic of Korea Air Force (RoKAF) conducted a teardown inspection of aircraft's EWIS (electrical wiring interconnection system) to determine the status of deterioration and the influence of failure occurrences due to it. The inspected aircraft were the retired fighter jets that had been used for more than 40 years. By analyzing defect type and the defect tendency, RoKAF can establish the necessary measures for the usage extension of their fleet and furthermore, the analysis results can be used as a basic data for the preparation of it's aircraft aging. EWIS inspection was done throughout careful visual inspection technique by removing all the ducts and pipes located in the fuselage and wings. For the aircraft wiring where no damage was found, the elongation tests were performed to determine the deterioration of wiring according to the location of the aircraft. The connectors, which is the main cause of intermittent failure, were completely disassembled and inspected for internal damage such as corrosion, abrasion, and traces of foreign objects. The detected defects were classified into 4 severity levels based on the type of damage, and the classified defects were weighted according to the criticality which may affects to it's system to establish the action plan.