• Title/Summary/Keyword: DCU(Digital Control Unit)

Search Result 9, Processing Time 0.03 seconds

Digital Control Unit Design for Power Amplifier Performance Improvement (전력증폭기 성능개선을 위한 디지털 제어장치 설계)

  • Lee, Byung-Sun;Roh, Hee-Jung
    • 전자공학회논문지 IE
    • /
    • v.47 no.4
    • /
    • pp.34-38
    • /
    • 2010
  • In this paper, we suggest DCU(Digital Control Unit) for performance improvement and stability security of base station power amplifier. The designed DCU controls electric power that is supplied to power amplifier. When the regular input is 10dBm, the regular output is measured 47.8dBm and the results are compared between the case of the applying and the non-applying the DCU. We got the result that PA system is very stable as DCU are very well operating in the boundary degradation of IMD by the over-power level input.

A study of an environmental radiation monitoring system(ERMS) using digital single channel analyzer(SCA) and dose conversion unit(DCU) (디지털 SCA와 DCU를 이용한 환경방사선 감시기에 관한 연구)

  • 오길환;우희곤;이쾌희;하달규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1372-1375
    • /
    • 1996
  • In this paper, we developed and ERMS, which monitors radiation continuously in the vicinity of the nuclear power plant not only to intend health and security of the adjacent residents but also to prevent environmental pollution. Especially, applying digital DCU and SCA which are easy to control and accurate, we obtained good results.

  • PDF

Development of Monitoring/Diagnosis/Control Device for intelligent equipment construction (지능형 설비 구축을 위한 감시/진단/제어 기기 개발)

  • Yang, Hang-Jun;Lee, Jun-Chol;Choi, In-Sun;Kim, Sung-Sik;Hong, Jung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.557-558
    • /
    • 2007
  • 변화, 발전하는 IT기술과 디지털 기술, 그리고 네트워킹 기술 등에 따라 변전소의 운용 및 자동화 부문에 있어서도 적지 않은 변화가 일어나고 있다. 변전소의 건설 및 운용 면에 있어서도 예외가 아니며, 관련된 관심 사항으로는 시스템 구축 및 운용 시의 경제적인 측면, 시스템의 신뢰성, 그리고 유지보수 및 설비 관리의 효율성 등을 언급할 수 있다. 최근의 기술 추세는 Ethernet 통신 기반의 Network Device를 근간으로 하는 시스템으로의 변신을 주장하고 있으며, 세계 유수의 전력 설비 Maker에서도 이에 부응하기 위한 Network Device를 개발, 출시하고 있는 실정이다. 당소에서도 이와 같은 기술 추세에 부응하여 소위 미래형 변전소에서 요구되는 각종 ND의 개발을 추진하고 있으며, 그 첫번째 결과물로 154kV GIS의 운용 시에 요구되는 각종 제어 및 감시를 위한 Digital Control Unit(이하 DCU)을 개발하였다. 두 번째로 이와 같은 DCU와 연계하여 기존의 Remote Control 기능을 구비하고 상위시스템과 연결되며 변전실내에서 운용되는 Remote Control Unit(이하 RCU)을 개발하였다. 마지막으로 예방진단 시스템과 관련하여 주요 전력 설비의 상태 정보를 취합하는 Serial 통신 기반의 Static Type의 Diagnostic Analysis Unit(이하 DAU)을 하나의 Network Device로 개발함으로써 감시, 진단, 제어 등의 요구기능이 일체화 된 네트워크 기반의 미래형 변전소 자동화 시스템 구축에 한걸음 다가가는 기반을 마련하였다.

  • PDF

A study on the implementation of door control unit for railway trains operable at low and high platforms

  • Young-Seok Cho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.7
    • /
    • pp.1-9
    • /
    • 2023
  • Currently, as the demand for stops in the urban increases resulting from an increase in the supply of express trains, the development of trains capable of operating both high-floor platforms in the urban and low-floor platforms in the suburbs is required. In this paper, we studied the design and fabrication of a controller for train doors that consists of low and high steps as a plug-in type door mechanism and thus can be used on low and high platforms. This DCU H/W was designed and implemented using 32 bit MCU to control 4 motors, 33 digital inputs and 16 digital outputs. In addition, based on the software life cycle of EN50128, 2 items of operation requirements and 12 items of control requirements were derived, and then they were designed and implemented as operation SW. The implemented SW was tested for each requirement. As a result, we performed tests on 13 items that could be tested in the mock-up out of 14 total requirement items and showed that the requirements were satisfied.

A study on daylight distributions for applying effective daylight responsive dimming systems in offices (사무공간에서 효율적인 조광제어시스템 적용을 위한 주광분포 연구)

  • Kim, Ga-Young;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.123-128
    • /
    • 2005
  • This study purposes to increase the energy-saving effects by reducing excessive intensity of radiation of artificial lighting through analyzing daylight incident A photosensor sends amounts of detected luminous flux to digital control unit(DCU) as a signal and then, it can decide dimming ratios, received a proper dimming signal from DCU. Generally it Is effective to control artificial lighting with the different control ratio of each row by setting a photosensor as same numbers and rows as artificial lighting. However, it is ineffective to do in initial costs of systems aspect in offices. As a result of grasping the distribution of daylight previously, we can dim different dimming ratios to each row of artificial lighting by a single photosensor.

  • PDF

Analysis of experimental data on daylight responsive dimming system performance for determining on effective dimming ratio (광센서 조광제어시스템의 효율적인 조광율 결정을 위한 실험 데이터 분석)

  • Kim, Ga-Young;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.167-172
    • /
    • 2005
  • This study based on the experimental data on the daylight responsive dimming systems performance. The purpose of this study increases the energy-saving effects by reducing excessive intensity of radiation of artificial lighting through analyzing incident daylight. The photosensor sends amounts of detected luminous flux to digital control unit(DCU) as a signal and then, it can decide dimming ratios, by received a proper dimming signal from DCU. Generally it is effective to control artificial lighting with the different control ratio of each row by setting a photosensor as same numbers and rows as artificial lighting. However, it is ineffective to do in initial costs of systems aspect in offices. By analyzing the data of this performance and finding regular ration between photosensors. we will execute different dimming ratios to each row of artificial lighting by a single photosensor.

  • PDF

The FPGA Implementation of Wavelet Transform Chip using Daubechies′4 Tap Filter for DSP Application

  • Jeong, Chang-Soo;Kim, Nam-Young
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.376-379
    • /
    • 1999
  • The wavelet transform chip is implemented with Daubechies' 4 tap filter. It works at 20MHz in Field Programmable Gate array (FPGA) implementation of Quadrature Mirror Filter(QMF) Lattice Structure. In this paper, the structure contains taro-channel quadrature mirror filter, data format converter(DFC), delay control unit(DCU), and three 20$\times$8 bits real multiplier. The structures for the DFC and DCU need to he regular and scalable, require minimum number of regular, and thereby lead to an efficient and scalable architecture for the Discrete Wavelet Transform(DWT). These results present the possibility that it can be used in Digital Signal Processing(DSP) application faster than Fourier transform at small area with lour cost.

  • PDF

Structural Design of SAR Control Units for Small Satellites Based on Critical Strain Theory (임계변형률 이론에 기반한 초소형 위성용 SAR 제어부 전장품 구조설계)

  • Jeongki Kim;Bonggeon Chae;Seunghun Lee;Hyunung Oh
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.2
    • /
    • pp.12-20
    • /
    • 2024
  • The application of reinforcement design to ensure the structural safety of electronics in small satellites is limited by the spatial constraints of the satellite structure during launch vibrations. Additionally, a reliable evaluation approach is needed for mounting highly integrated devices that are susceptible to fatigue failure. Although the Steinberg fatigue failure theory has been used to assess the structural integrity of electronic devices, recent studies have highlighted its theoretical limitations. In this paper, we propose a structural methodology based on the critical strain theory to design the digital control unit (DCU) of the X-band SAR payload component for the small SAR technology experimental project (S-STEP), a small satellite constellation. To validate the design, we conducted modal and random analyses using simplified modeling techniques. Based on our methodology, we ultimately demonstrated the structural safety of the electronics through analysis results, safety margin derivation, and functional tests conducted both before and after the launch test.

Analysis of Simulation of Daylight and Experiment for Determining on Effective Dimming Ratio (효과적인 조광제어시스템 적용을 위한 주광시뮬레이션과 실험데이터 분석)

  • Kim, Ga-Young;Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • This study proposes to increase the energy-saving effects by reducing excessive intensity of radiation of artificial lighting through analyzing daylight incident. A photosensor sends amounts of detected luminous flux to digital control unit(DCU) as a signal and then, it can decide dimming ratios, received a proper dimming signal from DCU. Generally it is effective to control artificial lighting with the different control ratio of each zone by setting a photosensor as same number and rows as artificial lighting. However, it is ineffective to do in initial costs of systems aspect in offices. As a result of grasping the distribution of daylight previously and analyzing daylight and dimming data, we can dim different dimming ratios to each zone of artificial lighting by a single photosensor.