• Title/Summary/Keyword: DC method

Search Result 3,467, Processing Time 0.026 seconds

Wireless Power Transfer for Electric Vehicles Charging Based on Hybrid Topology Switching With a Single Inverter

  • Chen, Yafei;Zhang, Hailong;Kim, Dong-Hee;Park, Sung-Jun;Park, Seong-Mi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_1
    • /
    • pp.115-124
    • /
    • 2020
  • In wireless power transfer (WPT) system, the conventional compensation topologies only can provide a constant current (CC) or constant voltage (CV) output under their resonant conditions. It is difficult to meet the CC and CV hybrid charging requirements without any other schemes. In this study, a switching hybrid topology (SHT) is proposed for CC and CV electric vehicle (EV) battery charging. By utilizing an additional capacitor and two AC switches (ACSs), a double-side LCC (DS-LCC) and an inductor and double capacitors-series (LCC-S) topologies are combined. According to the specified CC and CV charging profile, the CC and CV charging modes can be flexibly converted by the two additional ACSs. In addition, zero phase angle (ZPA) also can be achieved in both charging modes. In this method, because the operating frequency is fixed, without using PWM control, and only a small number of devices are added, it has the benefits of low-cost, easy-controllability and high efficiency. A 3.3-kW experimental prototype is configured to verify the proposed switching hybrid charger. The maximum DC efficiencies (at 3.3-kW) of the proposed SHT is 92.58%.

A study on the electronic EGR valve control method (전자식 EGR밸브 제어기법에 관한 연구)

  • Choi, Sang-Yun;Lee, Sang-Hun;Lee, Seon-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2594-2602
    • /
    • 2014
  • As environmental awareness increases, regulations on exhaust gas of automobile, which is a cause of air pollution, have been strengthened. In order to meet emission regulation, automobile companies and engine manufacturers have actively developed the related technologies. Because the emission control has become severe, the systems using electronic motor or solenoid valve for high precise control are needed. For this reason, it is required not only the optimization of composition of components for improving performance and efficiency of the system but also the development of optimal design technology of electronic control system by securing the designing and manufacturing technology of the components. In this paper, it is proposed the position characteristics for electronic EGR valve module through the applied control logic and experiment results.

The Structure of 1-[2-[[(4-chlorophenyl)-methyl]thio]-2-(2, 4-dichlorphenyl)ethyl]-1H imidazole (Sulconazole) nitrate, C18H16Cl3N3O3S

  • Shin, Hyun-So;Song, Hyun;Cho, Sung-Il;Pakr, Keun-Il
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.1
    • /
    • pp.14-18
    • /
    • 1997
  • Sulconazole nitrate, C18H16Cl3N3O3S, crystallizes in monoclinic, space group C2/c, with a=14.401(1), b=8.051(1), c=34.861(2) Å, β=95.9(1)°, g=0.58 mm-1, Dc=1.523 g/cm3, Dm=1.522 g/cm3, F(000)=1888.0, and z=8. Intensities for 2460 unique reflections were measured on a CAD4 diffractometer with graphited-monochromated Mo-Kα radiation. The structure was solved by direct method and refined by full matrix least squares to a final R=0.071 for 2182 reflections (Io > 2σIo). The bond lengths and angles are comparable with the values found in the analogues imidazole derivatives. The 2,4-dichlorophenyl ring(A) and the p-chlorophenyl ring(B) are almost planar with different heights [dihedral angle 17.3°] while the imidazole ring(C) is nearly perpendicular to the two phenyl rings[dihedral angles about the two rings A, B are 110.8° and 96.1° respectively]. In order to understand the overall conformation we calculated the selected distances (l1, l2, l3) among the center of the three rings and considered the imaginary plan D[C(7), C(9) and C(16)]. The two polar group S(8) and N(19) do not have gauche conformation and l2 value (4.47 Å) is shorter than the other imidazole derivatives. One -NO3 group are hydrogen bonded the two neighbored sulconazole molecules. The molecular crystal packing is also formed by two hydrogen bondings and van der Waals forces.

Exchange Coupling in CoZr/Ag/CoCr Trilayered Films (CoZr/Ag/CoCr 삼층박막의 교환결합)

  • 백종성;박용성;임우영;이수형;김종오
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.6
    • /
    • pp.357-361
    • /
    • 1998
  • For CoZr/Ag/CoCr trilayered films deposited by DC and FR magnetron sputtering method, ferromagentic resonance experiments have been used to investigate the dependence of the exchange coupling between CoZr and CoCr layers separated by Ag layer on the thickness of the Ag layer. The coupling strength K increases with increasing Ag thickness up to 10 $\AA$ with a maximum value of 748 Oe, but oscillates with increasing Ag thickness in the range from 20 to 100 $\AA$. The coupling strength is positive for all samples. Hence, it seems that the exchange coupling between CoZr and CoCr layers separated by Ag layer is ferromagnetic.

  • PDF

Auditory Thresholds of Black Rock Fish (조피볼락의 청각문턱치)

  • Park, Yong-Seok;Lee, Chang-Heon;Moon, Jong-Wook;Ahn, Jang-Young;Seo, Du-Ok
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.11 no.1
    • /
    • pp.88-97
    • /
    • 1999
  • Auditory thresholds were determined by means of a conditioned response to sound stimuli at frequencies 80, 100, 200, 300, 500 and 800 Hz for a 10 black rock fish, Sebastes schlegeli. The conditioned response was a change of a cardiac rhythm. It was established through an electric shock as unconditioned stimulus, and could be monitored on an oscilloscope. A stable acoustic condition was obtained by suspending the fish in a small cage at fixed position in the test tank. The sensitive frequencies ranged from 80 Hz to about 800 Hz, showing the best frequency around 100 Hz where the mean threshold value was 90.5 dB. A gradual rise below 300 Hz and a relatively sharp turn above 500 Hz were indicated in the audiogram. The method presented here seemed to be useful for a rapid determination of the audiogram of fishes.

  • PDF

Induced Polarization Surveys of Contaminants and Introduction to Case Studies (오염원에 대한 유도분극탐사 반응 및 사례 소개)

  • Kim, Bitnarae;Caesary, Desy;Yu, Huieun;Cho, AHyun;Song, Seo Young;Cho, Sung Oh;Joung, Inseok;Nam, Myung Jin
    • Journal of Soil and Groundwater Environment
    • /
    • v.25 no.2_spc
    • /
    • pp.86-100
    • /
    • 2020
  • Analyzing and monitoring environmental contaminants based on geophysical exploration techniques have become important and it is now widely applied to delineate spatial distribution geophysical characteristics in wide area. Among the techniques, induced polarization (IP) method, which measures polarization effects on electrical potential distribution, has drawn much attention as an effective tool for environmental monitoring since IP is sensitive to changes in biochemical reactions. However, various reactions stemming from the presence of multiple contaminants have greatly enhanced heterogeneity of polluted sites to result in highly variable electrical characteristics of the site. Those contaminants influence chemical and physical state of soil and groundwater to alter electrical double layer, which in turn influences polarization of the media. Since biochemical reactions between microbes and contaminants result in various IP effects, IP laboratory experiments were conducted to investigate IP responses of the contaminated soil samples under various conditions. Field IP surveys can delineate the spatial distribution of contamination, while providing additional information about electrical properties of a target medium, together with DC resistivity. Reviewing IP effects of contaminants as well as IP surveys can serve as a good starting point for the application of IP survey in site assessment for environmental remediation.

A Study on the Design/Simulation and Manufacturing for Localization of Parts in Scoop Control Assembly of Small Military Boat (소형 선박 제어 헤드 조립체의 국산화를 위한 설계/해석, 제작에 관한 연구)

  • Yeog, Gyeong-Hwan;Kim, Jae-Hyun;Jin, Chul-Kyu;Chun, Hyeon-Uk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.5
    • /
    • pp.597-608
    • /
    • 2021
  • The control head components used in small military vessels are designed to be domestically produced, prototypes, structural analysis, and casting methods are designed and cast. The control head assembly consists of a lever, an aluminum outside cover, Middle, front gear cover, back gear cover, and a zinc worm gear. In order to reverse the design of each component, 3D scanning device was used, 3D modeling was performed by CATIA, and prototype productions were carried out by 3D printer. In order to reduce the cost of components, gating system is used by gravity casting method. The SRG ratio of 1:0.9:0.6 was set by applying non-pressurized gating system to aluminum parts, 1:2.2:2.0 and pressurized gating system to zinc parts, and the shapes of sprue, runner and gate were designed. The results of porosity were also confirmed by casting analysis in order to determine whether the appropriate gating system can be designed. The results showed that all parts started solidification after filling completely. ANSYS was used for structural analysis, and the results confirmed that all five components had a safety factor of 15 more. All castings are free of defects in appearance, and CT results show only very small porosity. ZnDC1 zinc alloy worm gear has a tensile strength of 285 MPa and an elongation of 8%. The tensile strength of the four components of A356 aluminum alloy is about 137-162 MPa and the elongation is 4.8-6.5%.

A Study on the Gating System and Simulation for Gravity Casting of ZnDC1 Worm Gear (아연 합금 웜기어의 중력 주조 공정을 위한 주조 방안 설계 및 해석에 관한 연구)

  • Lee, Un-Gil;Kim, Jae-Hyun;Jin, Chul-Kyu;Chun, Hyeon-Uk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.5
    • /
    • pp.589-596
    • /
    • 2021
  • In this study, the optimum gating system was designed, and the two zinc alloy worm gears were manufactured in single process by applying a symmetrical gating system with 2 runners. The SRG ratio is set to 1 : 0.9 : 0.6, and the cross-sectional shapes such as sprue, runner and gate are designed. In order to determine whether the design of the gating system is appropriate, casting analysis was carried out. It takes 4.380 s to charge the casting 100%, 0.55 to 0.6 m/s at the gates and solidification begins after the casting is fully charged. The amount of air entrapment is 2% in the left gear and 6% in the right gear. Hot spots occurred in the center hole of the gear, and pores were found to occur around the upper part of the hole. Therefore, the design of the casting method is suitable for worm gears. CT analysis showed that all parts of worm gear were distributed with fine pores and some coarse pores were distributed around the central hole of worm gear. The yield strength and tensile strength were 220 MPa, 285 MPa, and the elongation rate was 8%. Vickers hardness is 82 HV.

A Study on Development and Diagnosis Factors of On-Line DC Leakage Current System for Junctions of High-Voltage Cables in Operation at Thermoelectric Power Station (화력 발전소 고전압 케이블 접속재의 On-Line 직류 누설 전류 시스템 개발과 진단 Factor에 관한 연구)

  • Park, Sung-Hee;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.187-193
    • /
    • 2018
  • There has been a gradual increase in the demand for the electric power in Korea. In order to meet the demand, power station should have technical functions with increased effectiveness. When accident happens in electric machinery at power stations, huge amount of economic losses and mulfunction of equipments occur. One of the accidents is a deteriorated cables operating power stations. In order to prevent cable accident in advance, we should monitor the insulation status of the cable. Cable accidents are resulting from the junctions. We have developed and installed a device in order to identify the status of junction part of power cable at Korea Western Power Co., Ltd.. We performed an accurate diagnosis for the stable utilization of junctions where the accidents occurs most frequently, and to increase the reliability. In this paper, we present the concepts of our device and the method of monitoring diagnosis for the stable use of junctions at cables predicting the life time of cables by analyzing the data obtained by the device. We also present the hardware aspect of the device we have developed.

Characteristic PCS of Inverter by Boost Converter of PV Generation (태양광 발전 부스트 컨버터를 이용한 인버터 PCS 특성)

  • Hwang, Lark-Hoon;Na, Seung-kwon;Oh, Sang-hak
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.6
    • /
    • pp.654-664
    • /
    • 2018
  • In this paper, this system is operated by PCS that is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to DC side with solar cell using a photovoltaic (PV) that it was so called constant voltage charge. it can cause the effect of energy saving of electric power, from 10 to 20%. and through a normal operation of electric energy storage system (EESS). In addition, better output waveform was generated because of pulse width modulation (PWM) method, and it was Proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.