• 제목/요약/키워드: DC link inverter

검색결과 449건 처리시간 0.039초

Design and Control Methods of Bidirectional DC-DC Converter for the Optimal DC-Link Voltage of PMSM Drive

  • Kim, Tae-Hoon;Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1944-1953
    • /
    • 2014
  • This paper shows the design and control methods of the bidirectional DC-DC converter to generate the proper DC-link voltage of a PMSM drive. Conventionally, because the controllable power of the PWM based voltage source inverter is limited by its DC-link voltage, the DC-DC converter is used for boosted DC-link voltage if the inverter source cannot generate enough operating voltage for the PMSM drive. In this paper, to obtain more utilization of this DC-DC converter, optimal DC-link voltage control for PMSM drive will be explained. First, the process and current path of the DC-DC converter will be illustrated, and a control method of this converter for variable DC-link voltage will then be explained. Finally, an improvement analysis of the optimal DC-link voltage control method, especially on the deadtime effect, will be explained. The DC-DC converter of the proposed control method is verified by the experiments by comparing with the conventional constant voltage control method.

무손실 가변 영전압 구간을 갖는 새로운 저손실 준 병렬공진 직류-링크 인버터 (A New Low Loss Quasi Parallel Resonant DC-Link Inverter with Variable Lossless Zero Voltage Duration)

  • 권경안;김권호;최익;정용채;박민용
    • 전력전자학회논문지
    • /
    • 제2권2호
    • /
    • pp.8-18
    • /
    • 1997
  • 본 논문에서는 개선된 PWM 적용성, 저손실 특성 및 낮은 전압 스트레스를 가지는 새로운 저손실 준 병렬공진 직류-링크 인버터를 제안한다. 직류-링크 동작손실을 대폭 감소시킴은 물론 넓은 동작범위에 걸쳐 안정한 소프트 스위칭을 보장하기 위하여 프리휠링 구간을 최소화시키는 방법을 또한 제안한다. 게다가 직류-링크의 영전압 구간의 무손실 제어에 의하여 낮은 변조지수 동작에 있어서도 제안된 인버터는 개선된 PWM 적용성을 보인다. 제안된 인버더 토폴로지의 유용성을 확인하기 위하여 실험 및 시뮬레이션을 행하였다.

Two Modified Z-Source Inverter Topologies - Solutions to Start-Up Dc-Link Voltage Overshoot and Source Current Ripple

  • Bharatkumar, Dave Heema;Singh, Dheerendra;Bansal, Hari Om
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1351-1365
    • /
    • 2019
  • This paper proposes two modified Z-source inverter topologies, namely an embedded L-Z-source inverter (EL-ZSI) and a coupled inductor L-Z source inverter (CL-ZSI). The proposed topologies offer a high voltage gain with a reduced passive component count and reduction in source current ripple when compared to conventional ZSI topologies. Additionally, they prevent overshoot in the dc-link voltage by suppressing heavy inrush currents. This feature reduces the transition time to reach the peak value of the dc-link voltage, and reduces the risk of component failure and overrating due to the inrush current. EL-ZSI and CL-ZSI possess all of the inherent advantages of the conventional L-ZSI topology while eliminating its drawbacks. To verify the effectiveness of the proposed topologies, MATLAB/Simulink models and scaled down laboratory prototypes were constructed. Experiments were performed at a low shoot through duty ratio of 0.1 and a modulation index as high as 0.9 to obtain a peak dc-link voltage of 53 V. This paper demonstrates the superiority of the proposed topologies over conventional ZSI topologies through a detailed comparative analysis. Moreover, experimental results verify that the proposed topologies would be advantageous for renewable energy source applications since they provide voltage gain enhancement, inrush current, dc-link voltage overshoot suppression and a reduction of the peak to peak source current ripple.

A Novel SVPWM Strategy Considering DC-link Balancing for a Multi-level Voltage Source Inverter

  • Kim, Rae-Young;Lee, Yo-Han;Hyun, Dong-Seok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.159-164
    • /
    • 1998
  • This paper proposes a SVPWM (space vector pulse width modulation) strategy for a multi-level voltage source inverter. This strategy is easily implemented as SPWM (sinusoidal pulse width modulation) and has the same DC-link voltage utilization as general SVPWM. The method to keep the voltage balancing of DC-link also is proposed by the analysis model of DC-link voltage fluctuation. The usefulness of the proposed SVPWM is verified through the simulation.

  • PDF

냉장고의 선형압축기 구동을 위한 단상 하프브리지 인버터 시스템에서 직류단 불평형 보상에 관한 연구 (DC Voltage Balancing Control of Half-Bridge PWM Inverter for Liniear Compressor of Refrigerator)

  • 김호진;김형진;김동윤;김장목
    • 전력전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.256-262
    • /
    • 2017
  • This paper presents the control algorithm of a single-phase AC/DC/AC PWM converter for the linear compressor of a refrigerator. The AC/DC/AC converter consists of a full-bridge PWM converter for the control of the input power factor and a half-bridge PWM inverter for the control of the single-phase linear compressor. At the DC-link of this topology, two capacitors are connected in series. These DC-link voltages must be balanced for safe operation. Thus, a new control method of DC voltage balancing for the half-bridge PWM inverter is proposed. The balancing algorithm uses the Integral-Proportional controller and inserts the DC-offset current at the Proportional-Resonant current controller of the inverter to solve the DC-link unbalanced voltages between the two capacitors. The proposed algorithm can be easily implemented without much computation and additional hardware circuit. The usefulness of the proposed algorithm is verified through several experiments.

High-Efficiency Power Conditioning System for Grid-Connected Photovoltaic Modules

  • Choi, Woo-Young;Choi, Jae-Yeon
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.561-567
    • /
    • 2011
  • This paper presents a high-efficiency power conditioning system (PCS) for grid-connected photovoltaic (PV) modules. The proposed PCS consists of a step-up DC-DC converter and a single-phase DC-AC inverter for the grid-connected PV modules. A soft-switching step-up DC-DC converter is proposed to generate a high DC-link voltage from the low PV module voltage with a high-efficiency. A DC-link voltage controller is presented for constant DC-link voltage regulation. A half-bridge inverter is used for the single-phase DC-AC inverter for grid connection. A grid current controller is suggested to supply PV electrical power to the power grid with a unity power factor. Experimental results are obtained from a 180 W grid-connected PV module system using the proposed PCS. The proposed PCS achieves a high power efficiency of 93.0 % with an unity power factor for a 60 Hz / 120 Vrms AC power grid.

Fundamental Output Voltage Enhancement of Half-Bridge Voltage Source Inverter with Low DC-link Capacitance

  • Elserougi, Ahmed;Massoud, Ahmed;Ahmed, Shehab
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.116-128
    • /
    • 2018
  • Conventionally, in order to reduce the ac components of the dc-link capacitors of the two-level Half-Bridge Voltage Source Inverter (HB-VSI), high dc-link capacitances are required. This necessitates the employment of short-lifetime and bulky electrolytic capacitors. In this paper, an analysis for the performance of low dc-link capacitances-based HB-VSI is presented to elucidate its ability to generate an enhanced fundamental output voltage magnitude without increasing the voltage rating of the involved switches. This feature is constrained by the load displacement factor. The introduced enhancement is due to the ac components of the capacitors' voltages. The presented approach can be employed for multi-phase systems through using multi single-phase HB-VSI(s). Mathematical analysis of the proposed approach is presented in this paper. To ensure a successful operation of the proposed approach, a closed loop current controller is examined. An expression for the critical dc-link capacitance, which is the lowest dc-link capacitance that can be employed for unipolar capacitors' voltages, is derived. Finally, simulation and experimental results are presented to validate the proposed claims.

가변 무손실 영전압 스위칭 구간 특성을 가지는 고효율 공진형 DC-Link Inverter (High Efficiency Quasi-Parallel Resonant DC-Link Inverter with Lossless Controllable Zero Voltage Interval)

  • 권경안;박재식;박민용;김권호;정용채
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.350-352
    • /
    • 1996
  • A Hight Efficiency Quasi-Parallel Resonant DC-Link Inverter which shows highly improved PWM capability, low loss characteristic and low voltage stress is presented. A method to minimize freewheeling interval, which is able to largely decrease DC-link operation losses and to steadily guarantee soft switching in the wide operation region is proposed. Analysis and simple experiments were performed to verify validity of the proposed inverter topology.

  • PDF

무효전력 보상 용량 증대 및 DC 링크 전압 저감을 위한 SVC 결합형 UPQC (SVC coupled UPQC for reactive power compensation capacity increase and DC link voltage reduction)

  • 표수한;박장현;오정식;박태식
    • 전기전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.99-106
    • /
    • 2019
  • 본 논문에서는 UPQC 시스템과 SVC를 결합한 새로운 형태의 보상장치를 제안하고자 한다. 기존의 UPQC는 직렬형 인버터, 병렬형 인버터, DC 링크로 구성되어 있어있으며 우수한 전력품질 보상 성능을 보이지만 높은 인버터 정격을 요구한다. 제안된 방식은 직렬형 인버터, 병렬형 인버터와 DC 링크 그리고 병렬형 인버터의 출력단에 결합된 SVC로 구성되어 있으며, 기존 UPQC에 비해 넓은 무효전력 보상 범위와 낮은 DC 링크 전압의 장점을 가지고 있다. 또한, SVC가 결합된 새로운 UPQC의 구성은 Matlab 시뮬레이션을 통해 성능을 검증하였다.

3상 BLDC 전동기 구동을 위한 4-스위치 인버터의 DC-Link 전압 불평형 보상 (DC-Link Voltage Unbalancing Compensation of Four-Switch Inverter for Three-Phase BLDC Motor Drive)

  • 박상훈;윤용호;이병국;이수원;원충연
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.391-396
    • /
    • 2009
  • In this paper, a control algorithm for DC-Link voltage unbalancing compensation of a four-switch inverter for a three-phase BLDC motor drive is proposed. Compared with a conventional six-switch inverter, the split source of the four-switch inverter can be obtained by splitting DC-link capacitor into two capacitors to drive the three phase BLDC motor. The voltages across each of two capacitors are not always equal in steady state because of the unbalance in the impedance of the DC-link capacitors $C_1$ and $C_2$ or the variable current flowed into the capacitor's neutral point in motor control. Despite the unbalance, if the BLDC motor may be run for a long time the voltage across one of the capacitors is more increased. So the unbalance in the capacitors voltages will be accelerated. As a result, The current ripple and torque ripple is increased due to the fluctuation of input current which flows into 3-phase BLDC motor. According to that, the vibration of motor will be increased and the whole system will be instable. This paper presents a control algorithm for DC-Link voltage unbalancing compensation. The sampling from the voltages across each of two capacitors is used to perform the voltage control of DC-Link by using the feedforward controller.