• Title/Summary/Keyword: DC injection control

Search Result 60, Processing Time 0.023 seconds

DC Injection Control for Grid-Connected Single-Phase Inverters Based on Virtual Capacitor

  • Wang, Wei;Wang, Ping;Bei, Taizhou;Cai, Mengmeng
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1338-1347
    • /
    • 2015
  • DC injection is a critical issue in transformerless grid-connected inverters. DC injection control based on virtual capacitor has the advantages of low cost, low loss, high accuracy and easy implementation. In this paper, the principle of DC injection control based on virtual capacitor was analyzed. In addition, the applicable conditions, working process, steady state error and advantages were also discussed in detail. The design of the control parameters based on virtual capacitor was proposed in a grid-connected inverter with LCL filter. The robustness of the control parameters was also discussed. Simulation and experimental results verify the validity of the analysis and demonstrate that this research has a certain value in engineering applications.

Fault-Tolerant Control of Cascaded H-Bridge Converters Using Double Zero-Sequence Voltage Injection and DC Voltage Optimization

  • Ji, Zhendong;Zhao, Jianfeng;Sun, Yichao;Yao, Xiaojun;Zhu, Zean
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.946-956
    • /
    • 2014
  • Cascaded H-Bridge (CHB) converters can be directly connected to medium-voltage grids without using transformers and they possess the advantages of large capacity and low harmonics. They are significant tools for providing grid connections in large-capacity renewable energy systems. However, the reliability of a grid-connected CHB converter can be seriously influenced by the number of power switching devices that exist in the structure. This paper proposes a fault-tolerant control strategy based on double zero-sequence voltage injection and DC voltage optimization to improve the reliability of star-connected CHB converters after one or more power units have been bypassed. By injecting double zero-sequence voltages into each phase cluster, the DC voltages of the healthy units can be rapidly balanced after the faulty units are bypassed. In addition, optimizing the DC voltage increases the number of faulty units that can be tolerated and improves the reliability of the converter. Simulations and experimental results are shown for a seven-level three-phase CHB converter to validate the efficiency and feasibility of this strategy.

A DC Ripple Voltage Suppression Scheme by Harmonic Injection in Three Phase Buck Diode Rectifiers with Unity Power Factor (단위 역률을 갖는 3상 강압형 다이오드 정류기에서 고조파 주입에 의한 DC 리플전압 저감 기법)

  • 고종진
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.305-308
    • /
    • 2000
  • A technique to suppress the low frequency ripple voltage of the DC output in three phase buck diode rectifiers is presented in this paper. The proposed pulse frequency modulation methods and duty ratio modulation methods are employed to regulate the output voltage of the buck diode rectifiers and guarantee zero-current -switching(ZCS) of the switch over the wide load range The proposed control methods used in this paper provide generally good performance such as low THD of the input line current and unity power factor. IN addition control methods can be effectively used to suppress the low frequency ripple voltage appeared in the dc output voltage. The harmonic injection technique illustrates its validity and effectiveness through the simulations.

  • PDF

The Analysis and Compensation of DC to DC Converter with Current Mode Controller (전류모드제어를 적용한 직류전원장치의 해석 및 보상에 관한 연구)

  • 김철진;김영태;송요창
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.5
    • /
    • pp.230-237
    • /
    • 2003
  • Current mode control has been used for DC to DC converters for over twenty years. There are many different control schemes which use the inductor current signal in one way or another to control the DC to DC converter. In this paper, the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the guarantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test result. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency fc is early 1/5 of switching frequency, fs, from the experimental result with frequency response analyzer.

Auto-Tuning PI control using limitted step response for brushless DC motor speed control (브러시리스 직류전동기 속도 제어를 위한 한계스텝응답 특성을 이용한 Auto-tuning PI 제어)

  • 전장현;전인효최중경박승엽
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.203-206
    • /
    • 1998
  • This paper describes the procedure of getting information about auto-tuning of PID regulator by the injection of high step input, called limited input, during a transient time of control. The key point is that system identification and control could be continuously executed. This means that the system information obtained by limited input despite of system uncertainty can be continuously applied to the PI regulator. Simulation and experiment result of brushless DC motor system having monotone increasing step response demonstrate the usefulness of proposed auto-tuning algorithm.

  • PDF

Four-switch Three-phase Inverter control method applied by simplified Space Vector PWM (간략화 된 SVPWM을 적용한 4-Switch 3-Phase Inverter의 제어 방법)

  • Son, Sang-Hun;Park, Young-Joo;Choy, Ick
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.3
    • /
    • pp.283-292
    • /
    • 2016
  • The performance of 4-switch 3-phase inverter(: FSTPI) which replace two switches of 6-switch 3-phase inverter(: SSTPI) is mainly affected by the compensator unbalanced voltages and output voltage control method. This paper proposes a DC offset current injection method to compensate the capacitor unbalanced voltages for FSTPI. A simplified SVPWM method which can be applied to FSTPI is also proposed. The validity of the proposed methods is verified by simulation and experiment using SPMSM.

A 360Hz DC Ripple-Voltage Suppression Scheme in Three-Phase Soft-Switched Buck Converter (360Hz DC 리플-전압 감소기법을 사용한 3-Phase Soft-Switched Buck Converter)

  • Choi, Ju-Yeop;Ko, Jong-Jin;Song, Joong-Ho;Choy, Ick;Jeong, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.12
    • /
    • pp.813-820
    • /
    • 2000
  • A technique to suppress the low frequency ripple voltage of the DC output in three phase buck diode converter is presented in this paper. The proposed pulse frequency modulation methods and duty ratio modulation methods are employed to regulate the output voltage of the buck diode converter and guarantee zero-current-switching(ZCS) of the switch over the wide load range. The proposed control methods used in this paper provide generally good performance such as low THD of the input line current and unity power factor. In addition, control methods can be effectively used to suppress the low frequency ripple voltage appeared in the dc output voltage. The harmonic injection technique illustrates its validity and effectiveness through the simulations and experiments.

  • PDF

Compensation Strategy to Eliminate the Effect of Current Measurement Offsets in Grid-Connected Inverters

  • Lee, Chang-Hee;Choi, Jong-Woo
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.383-391
    • /
    • 2014
  • For the digital control of systems such as grid-connected inverters, measuring inverter output currents accurately is essential. However, current measurement offsets are inevitably generated by current measurement paths and cause DC current components in real inverter output currents. Real inverter output currents with DC components cause the DC-link capacitor voltage to oscillate at the frequency of a utility voltage. For these reasons, current measurement offsets deteriorate the overall system performance. A compensation strategy to eliminate the effect of current measurement offsets in grid-connected inverters is proposed in this study. The validity of the proposed compensation strategy is verified through simulations and experiments. Results show that the proposed compensation strategy improves the performance of grid-connected inverters.

A study on neutral-point voltage balance with harmonic component injection for single phase three-level NPC converter (고조파 주입을 통한 단상 3레벨 NPC 컨버터 중성점 전압 밸런싱 연구)

  • Kang, Kyoung Pil;Kim, Ho-Sung;Cho, Jintae;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.316-317
    • /
    • 2018
  • This paper propse the DC link capacitor voltage balancing control for three level neutral point clamped converter with harmonic component injection method. The injcetion voltage consists of harmonic component and DC link capacitor voltage difference. Theoretical analysis is provided to balance the DC link voltage, and it shows that harmonic component compensates the unbalanced condition between the capacitors. Both simulations and experiments are carried out to show that the voltage unbalance have been decreased by the proposed method.

  • PDF

An Optical Pulse-Width Modulation Generator Using a Single-Mode Fabry-Pérot Laser Diode

  • Tran, Quoc-Hoai;Nakarmi, Bikash;Won, Yong Hyub
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.255-259
    • /
    • 2015
  • We have proposed and experimentally verified a pulse-width modulation (PWM) generator which directly generated a PWM signal in the optical domain. Output waveforms were clear at the repetition rate of 16 MHz; the duty cycle (DC) was from 14.7% to 72.1%; and the DC-control resolution was about 4.399%/dB. The PWM generator' operation principle is based on the injection-locking property of a single-mode Fabry-$P{\acute{e}}rot$ laser diode (SMFP-LD). The SMFP-LD, which has a self-locked mode wavelength at ${\lambda}_{PWM}$, was used to detect the power of the injection-locking signal (optical analog input). If the analog input power is high, the SMFP-LD is locked to the wavelength of the input signal ${\lambda}_a$ and there is no output after an optical bandpass filter (OBF). If the analog input power is low, the SMFP-LD is unlocked and there is output signal at ${\lambda}_{PWM}$ after the OBF. Thus, the SMFP-LD plus the OBF provide digital output for an analog input. The DC of the output PWM signal can be controlled by tuning the power of the analog input.