• 제목/요약/키워드: DC electric railway systems

검색결과 35건 처리시간 0.028초

도시철도 전식방지 조사보고 현황 (Investigation for the Report of DC Traction Stray Current Protection)

  • 이현구;하태현;정호성;한문섭;배정효
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.281-285
    • /
    • 2008
  • Corrosion of metallic structures arises when an electric current flows from the metal into the electrolyte such as soil and water. The potential difference across the metal-electrolyte interface, the driving force for the corrosion current, can emerge due to a variety of temperature, pH, humidity and resistivity etc.. With respect to a given structure, a stray current is to be defined as a current flowing on a structure that is not part of the intended electrical circuit. Stray currents are caused by other cathodic protection installations, grounding systems and welding posts, referred to as steady state stray currents. But most often traction systems like railroads and tramlines are responsible for large dynamic stray currents. This type of stray current is generally results from the leakage of return currents from large DC traction systems that are grounded or have a bad earth-insulated return path. This paper investigates the reports, which is made for protecting the electrical corrosion by the DC traction stray current before the construction period.

  • PDF

직류전기철도 시스템에 있어서의 변전소 송출전압에 따른 회생전력유효이용 (An Effective Utilization of Regenerative Power According to the Output Voltage of Substations in the DC Electric Railways)

  • Kim, Yang-Mo
    • 대한전기학회논문지
    • /
    • 제39권2호
    • /
    • pp.149-156
    • /
    • 1990
  • In DC electric railway systems, the feeding currrnt is not permitted to flow backward in almost all the substations and the pantograph voltages at the regenerating cars rise extremely by the voltage drop of the resistance of the feeder line. In order to prevent the overrise of the pantograph voltage in power regenerating cars, the squeezing circuits for the regenerative current are equipped and this leads to double losses, which are an extra worn-out of the brake-shoes and an ineffective use of regenerative power. In this study, the insertion of resistors in the feeder line system is proposed as a possible method for the effective utilization of the regenerative power in the electric railways. Also it is investigated how the output voltages of substations affect the effective use of regenertive capability. The investigation results show that the energy savings and the reduction of the worn-out of the brake-shoe can be achieved at the same time by the insertion of resistors in the feeder line system.

  • PDF

DC 급전계통 고저항 지락보호에 대한 연구 (A Study on High Impedance Grounding Protection for DC Power Supply System)

  • 이국명;김병현;소선영;김학련
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.878-884
    • /
    • 2006
  • Grounding fault and short of the DC power supply systems are detected and protected by high-speed circuit breaker, linked breaking device, ground relay and fault selective device, all of which are installed and operated in substaions. however, there have been many cases in which the protective devices did not detect grounding of of the over head catenary systems on concrete support for an extended period of time. Such cases often cause severe damages to the supports with high grounding resistances. If grounding accidents occur repetitively, the earth current and the rise of earth potential can damage not only passenger and staff but also electric facilities and equipment, necessitating high cost and endeavor to restore. The following study points out various problems that can be occurred occur as a result of high impedance grounding accident, and proposes a new system which can protect and intercept them.

  • PDF

Ripple Analysis and Control of Electric Multiple Unit Traction Drives under a Fluctuating DC Link Voltage

  • Diao, Li-Jun;Dong, Kan;Yin, Shao-Bo;Tang, Jing;Chen, Jie
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1851-1860
    • /
    • 2016
  • The traction motors in electric multiple unit (EMU) trains are powered by AC-DC-AC converters, and the DC link voltage is generated by single phase PWM converters, with a fluctuation component under twice the frequency of the input catenary AC grid, which causes fluctuations in the motor torque and current. Traditionally, heavy and low-efficiency hardware LC resonant filters parallel in the DC side are adopted to reduce the ripple effect. In this paper, an analytical model of the ripple phenomenon is derived and analyzed in the frequency domain, and a ripple control scheme compensating the slip frequency of rotor vector control systems without a hardware filter is applied to reduce the torque and current ripple amplitude. Then a relatively simple discretization method is chosen to discretize the algorithm with a high discrete accuracy. Simulation and experimental results validate the proposed ripple control strategy.

직류급전계통의 회생용 인버터 실용화 적용 (Application of regenerative inverter on DC feeding)

  • 한문섭;장동욱;신효범;김성태;김민수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2200-2201
    • /
    • 2011
  • DC railway systems have been adopted in the urban rail train. When EMU decelerates using electric breaking, regenerative power occurs. extra power is forcibly wasted by resisterIf DC transit system has inverter for reusing regenerative power, energy efficiency in DC transit system will be increased. in this paper present developed regenerative power inverter and its field test result.

  • PDF

철도 전기 시스템 (Rail Road Electric Traction System)

  • 데버랜전고팔;노영환;김윤호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.646-658
    • /
    • 2006
  • In this paper, the details of electric traction voltages which are widely used for metro and mainline trains are presented. The problems encountered in catenaries, pressure of the pantograph pan, catenary contact cross sectional area, materials etc are well covered. Catenary height from the rail for main line, bridges, sheds etc is discussed. The catenary running details and switching of one catenary to another are explained. The dead zones in 3 phase grid as well as in DC are presented here. The pantograph structure, blades, shoes etc. for AC/DC EMUs are dealt. The schematic diagram for electrification systems used for railways are given and explained with typical electrical parameters of Indian Railways.

  • PDF

절연구간 통과시 전기철도 차량에 유입되는 전력 품질 분석 (An analysis of the power quality problem at an electric train according to dead section)

  • 이봉이;김재철;문종필;한성호;이수길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.51-53
    • /
    • 2005
  • At the railway feeding system, a role of dead section is very important. Because, dead section is essential installation that AC feeding system meets DC feeding system or phase is changed between AC feeding systems. But, in dead section it is possible that an electric train meets interruption. In Korea, a study on the dead section isn't yet accomplished in depth. Accordingly. In this paper, when electric train is in dead-section power quality problem on electric train was dealt. Modeling and simulation using PSCAD/EMTDC was accomplished to analyze.

  • PDF

교류전기철도 불평형 전력 개선을 위한 전력보상장치 제어 (Power Compensator Control for Improving Unbalanced Power of AC Electric Railway)

  • 우제훈;조종민;이태훈;차한주
    • 전력전자학회논문지
    • /
    • 제25권3호
    • /
    • pp.213-218
    • /
    • 2020
  • In this study, we propose a control algorithm to reduce the unbalanced characteristics of a three-phase system power caused by the unbalanced load of the AC electric railway. Then, we verify its performance through the design of a power compensator and experiments applying it. Like electric railway systems, a Scott transformer is applied, and the load and single-phase back-to-back converters are connected to the M-phase and T-phase outputs. The back-to-back converter monitors the difference in active power between the unbalanced loads in real-time and compensates for the power by using bidirectional characteristics. The active power is performed through PI control in the synchronous coordinate system, and DC link overall voltage and voltage balancing control are controlled jointly by M-phase and T-phase converters to improve the responsiveness of the system. To verify the performance of the proposed power compensation device, an experiment was performed under the condition that M-phase 5 kW and T-phase 1 kW unbalanced load. As a result of the experiment, the unbalance rate of the three-phase current after the operation of the power compensator decreases by 58.66% from 65.04% to 6.38%, and the excellent performance of the power compensator proposed in this study is verified.

인천 국제공항청사 경전철 도입에 따른 고조파 영향 분석 (Harmonic Evaluation of An Imported IAT(Intra Airport Transit) System in Incheon International Airport)

  • 이준경;이승혁;김진오;정현수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.788-793
    • /
    • 2005
  • This paper presents harmonic evaluation of an IAT(Intra Airport Transit) system in Incheon International Airport. It will be used electric vehicles with 80 kW per car that are produced Mitsubishi Heavy Industries Ltd, and one car is constructed with SIV(Static Inverter), VVVF(Variable Voltage and Variable Frequency) and two induction motor. The operated vehicles in the IAT system are rapidly changing DC load, and at a feeding substation, 3-phase electric power is transferred to DC 750 V by rectifier. Since, vehicles are also changing continuously, the voltages for the DC load fluctuate in the IAT system, and moreover, the fluctuating voltages generate high-order harmonics. This means that there is the difficulty in maintaining power quality in KEPCO systems' side. Therefore, the power quality of the IAT system in Incheon International Airport is evaluated using PSCAD/EMTDC simulator in the paper. The THD(Total Harmonic Distortion) of voltages and TDD(Total Demand Distortion) of currents, indices are calculated for the IAT system using the results of PSCAD/EMTDC dynamic simulation.

  • PDF

매설배관과 직류전기철도의 표유전류 간섭분석 (Analysis of Stray Current Interference between Underground Pipelines and DC Electric Railways)

  • 하윤철;배정효;하태현;이현구;김대경
    • 한국가스학회지
    • /
    • 제10권3호
    • /
    • pp.41-47
    • /
    • 2006
  • 가스배관, 상수관, 송유관 등의 지중 매설배관이 직류 전기철도와 인접해 있는 경우, 전기철도 시스템의 귀선 회로로 사용되는 레일에서 누설되는 표유전류에 의해 이들 금속배관에는 전기적 부식, 즉 전식이 발생할 수 있다. 전식에 의한 집중 부식은 전기방식으로 보호되는 배관에 있어서도 지속적인 재료의 열화와 이에 따른 파손을 일으킬 수 있어 대형사고로 발전할 소지를 가지고 있다. 국내에서는 이러한 표유전류에 대한 대책으로 배관과 레일을 전기적으로 접속하는 배류법이 적용되고 있는데 특히 가스배관을 중심으로 한 강제배류법의 급속한 증가에 의해 간섭문제가 매우 복잡해지고 있다. 본 논문에서는 직류전기철도시스템과 매설배관 사이의 전기적 간섭 문제를 서울과 부산 지역에서 수행한 현장 실태조사의 결과를 통해 살펴본다.

  • PDF