• 제목/요약/키워드: DC current measurement

검색결과 231건 처리시간 0.028초

Compensation Strategy to Eliminate the Effect of Current Measurement Offsets in Grid-Connected Inverters

  • Lee, Chang-Hee;Choi, Jong-Woo
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.383-391
    • /
    • 2014
  • For the digital control of systems such as grid-connected inverters, measuring inverter output currents accurately is essential. However, current measurement offsets are inevitably generated by current measurement paths and cause DC current components in real inverter output currents. Real inverter output currents with DC components cause the DC-link capacitor voltage to oscillate at the frequency of a utility voltage. For these reasons, current measurement offsets deteriorate the overall system performance. A compensation strategy to eliminate the effect of current measurement offsets in grid-connected inverters is proposed in this study. The validity of the proposed compensation strategy is verified through simulations and experiments. Results show that the proposed compensation strategy improves the performance of grid-connected inverters.

열전형 전류 변환기의 교류-직류 전류 변환차이 자동측정시스템 개발 (Development of an automatic measurement system for the AC-DC current transfer difference of the thermal current converter)

  • 권성원;정재갑;김문석;김규태;류제천
    • 센서학회지
    • /
    • 제14권5호
    • /
    • pp.350-356
    • /
    • 2005
  • We have developed a dual-channel type automatic measurement system to evaluate AC-DC current transfer difference of the thermal current converter(TCC) which is primary standard of AC current. The output drift effect of the TCC is minimized by measuring simultaneously the output voltages of two TCCs using voltmeter. Furthermore, the offset voltage of the voltmeter is cancelled nearly out by taking the average values of two outputs of TCCs measured with the forward-reverse directions using dual channel scanner. The uncertainties of the automatic system were 7 to $86{\mu}A/A$ for 3 mA to 10 A at 40 Hz to 20 kHz, which were evaluated by the comparisons between adjacent range of TCCs and inter-comparison with national measurement institute of Germany(PTB). The capability for ac-dc transfer difference measurement was improved by one order compared with that for the manual ac-dc measurement system.

DC링크 전류센서를 이용한 삼상전류 측정 방식에서 최소 스위칭 시간의 단축 (Reduction of Minimum Switching Duration in the Measurement of Three Phase Current with DC-Link Current Sensor)

  • 김경서
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권12호
    • /
    • pp.649-654
    • /
    • 2003
  • The simplest method for measuring output currents of the three phase inverters is to measure them with three current sensors such as hall sensors. This method requires at least two current sensors, and these types of sensors are somewhat expensive. More economical method is measuring DC link current with a simple shunt resistor, then, reconstructing output current using the DC link current value and the switching status. However, in low speed region, the measurement becomes difficult and even impossible due to the requirement of minimum switching duration for A/D conversion. These problems can be overcome by limitation of switching duration. Limitation of switching, however, causes voltage and current distortion. Owing to compensation, distortion can be effectively suppressed. However these increase acoustic noise due to increment of current ripple. In this paper, a current measurement method is proposed, which can reduce minimum switching duration resulting in reduction of acoustic noise. The validity of proposed method is confirmed through experiment.

직류전류측정기의 안전성 향상을 위한 고내구성 보호소자의 가용체 설계 (Design for a Fuse of High Durability Protection Elements for Improving the Safety of DC Current Measurement Device)

  • 이예지;윤재서;조성철;노성여
    • 한국전기전자재료학회논문지
    • /
    • 제33권3호
    • /
    • pp.201-207
    • /
    • 2020
  • With the expansion in the use of DC power systems and increased need for system maintenance, the development of measurement devices for maintenance requires high stability. Of the different kinds of DC current measurement devices, the single-shot measurement device causes the input signal of the current measuring unit to initially generate a high inrush current. The high inrush current flows into the signal processor of the meter, shortening the life of the internal fuses and causing failure. Therefore, in this study, the I2t value for increasing the durability of the fuse is designed using the available wire diameter. Operating characteristics for 210~400% over-current of the rated current, which is relatively low over-current, are realized by the plating of low melting tin metal. As a result, a method of designing a fuse element for a DC power supply, which improves the safety of the DC current measurement device by blocking the failure caused by the inrush current, is presented.

입력 전류의 측정이 필요없는 Boost 컨버터의 역률 보정에 관한 연구 (A Study On The Power Factor Correction Of The Boost Converter Without The Input Current Measurement)

  • 조상준;이광원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.376-378
    • /
    • 1996
  • This paper presents a new PFC control method which replaces a fast line current measurement with a filtered load current measurement. Using the power balance relation between the input and the output of the boost converter. the input current can be described as the function of load current. Thus the PWM signal which effects the switching control of the boost converter is generated using the PFC input voltage, the PFC output voltage and the load current as input variables. By using a filter between the bridge rectifier and a dc-to-dc converter, the input voltage of the dc-to-dc converter is forced to always maintain above zero volt. Then the input current traces a sinewave in phase. The proposed scheme accomplishes a very high power factor and a low harmonic distortion of the line current. The validity of this scheme is demonstrated through simulation.

  • PDF

삼상 브러시리스 직류전동기의 파라미터 측정에 관한 연구 (A Study on the Parameter Measurement of Three Phase Brushless DC Moto)

  • 임영철;장영학;조경영;정영국
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제5권3호
    • /
    • pp.54-63
    • /
    • 1991
  • This paper describes an effort to develope a microcomputer-based parameter measurement system for a brushless DC motor. Back EMF equation is derived from back EMF waveform of a brushless DC motor. To minimize error the due to the ripple component in the measured armature current, digital averaging filter is employed. The whole identification process of signal generation, measurement parameter determination is fully automated. A new identification algorithm for the brushless DC motor parameters is developed. New parameter correction method is proposed using the deadzone current and the time to reach the peak current. In the proposed correction method, the measured current is in excellent agreement with the estimated current.

  • PDF

클램프 형 직교류 저 전류 측정 센서 (A Clamp Type Sensor for AC/DC Low Current Measurement)

  • 박영태;유광민
    • 한국전기전자재료학회논문지
    • /
    • 제15권12호
    • /
    • pp.1045-1053
    • /
    • 2002
  • This paper describes characteristics of the developed current sensor by means of two identically wound magnetic cores forming a clamp like for measurement of a low DC, or AC current. This sensor consists of peak value detectors, a sensor of an electrically compensated current transformer type, a reference alternating voltage, Precision measuring circuits to measure the output signals of sensor with harmonics, and can be measured up to 2 A at DC, or AC current. The current sensor shows a measurement accuracy of less than 0.3% in the frequency range 40 Hz - 10 HBz. The resolution and sensitivity of the sensor were evaluated 0.1 mA and 10 mV/mA, respectively.

도시철도 직류 전력량 계측을 위한 직류용 스마트미터링 시스템 개발 및 성능시험 (Development and Performance Test of DC Smart Metering System for the DC Power Measurement of Urban Railway)

  • 정호성;신승권;김형철;박종영
    • 전기학회논문지
    • /
    • 제63권5호
    • /
    • pp.713-718
    • /
    • 2014
  • DC urban railway power system consists of DC power network and AC power network. The DC power network supplies electric power to railway vehicles and the AC power network supplies electric power to station electric equipment. Recently, because of power consumption reduction and peak load shaving, intelligent measurement of regenerative energy and renewable energy adapted on DC urban railway is required. For this reason, DC smart metering system for DC power network shall be developed. Therefore, in this paper, DC voltage sensor, current sensor, and DC smart meter were developed and evaluated by performance test. DC voltage sensor was developed for measuring standard voltage range of DC urban railway, and DC current sensor was developed as hall effect split core type in order to install in existing system. DC smart meter possesses function of general intelligent electric power meter, such as measuring electricity and wireless communication etc. And, DC voltage sensor showed average 0.17% of measuring error for 2,000V/50mA, and current sensor showed average 0.21% of measuring error for ${\pm}2,000V/{\pm}4V$ in performance test. Also DC smart meter showed maximum 0.92% of measuring error for output of voltage sensor and current sensor. In similar environment for real DC power network, measuring error rate was under 0.5%. In conclusion, accuracy of DC smart metering system was confirmed by performance test, and more detailed performance will be verified by further real operation DC urban railway line test.

단일 DC-Link 전류 계측만을 이용한 BLDC 구동시스템의 디지털 전류 제어 (A Digital Current Control using Single DC-Link Current Sensing of BLDC Actuation Systems)

  • 한봉수
    • 한국군사과학기술학회지
    • /
    • 제22권1호
    • /
    • pp.72-80
    • /
    • 2019
  • In this paper, we propose a digital DC-Link current control approach for BLDC actuation systems. The proposed approach consists of the following two components: first, DC-Link current measurement with sampling instances synchronized with PWM frequency, and second, current control using single DC-Link current rather than three phases current of a motor. The proposed method proved its performance through experiments and simulation. The results showed that the control performance are increased compared with the BLDC actuation system which does not use current control.

Van der Pauw 측정법을 이용한 금속 도전율의 직류와 교류특성 (DC and AC Characterization of Metals Conductivity using the van der Pauw Measurement Method)

  • 강전홍;한상옥
    • 전기학회논문지P
    • /
    • 제56권4호
    • /
    • pp.157-160
    • /
    • 2007
  • The van der Pauw technique is one of the popular methods for determining the conductivity of flat metal samples. Traceability of the national standard for the conductivity has been achieved by direct current measurement techniques in national measurement institutes of many countries. But recently, alternative current measurement techniques for determining the conductivity of flat metal samples is also interested. In this study, we measured the conductivity of non-ferrous and ferrous flat metals at alternative current using van der Pauw technique. As measurement results, the conductivities of the samples were decreased according to increasing the test frequency even though the decreasing ratio was different.