Control of the Bidirectional DC/DC Converter for a DC Distribution Power System in Electric Vehicles (전기 자동차의 DC 배전 시스템을 위한 양방향 DC/DC 컨버터의 제어)

  • Chang, Han-Sol;Lee, Joon-Min;Kim, Choon-Tack;La, Jae-Du;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.943-949
    • /
    • 2013
  • Recently, an electric vehicle (EV) has been become a huge issue in the automotive industry. The EV has many electrical units: electric motors, batteries, converters, etc. The DC distribution power system (DPS) is essential for the EV. The DC DPS offers many advantages. However, multiple loads in the DC DPS may affect the severe instability on the DC bus voltage. Therefore, a voltage bus conditioner (VBC) may use the DC DPS. The VBC is used to mitigate the voltage transient on the bus. Thus, a suitable control technique should be selected for the VBC. In this research, Current controller with fixed switching frequency is designed and applied for the VBC. The DC DPS consist of both a resistor load and a boost converter load. The load variations cause the instability of the DC DPS. This instability is mitigated by the VBC. The simulation results by Matlab simulink and experimental results are presented for validating the proposed VBC and designed control technique.

Design and Analysis of PI-IP Hybrid Controller of Interlinking Converter for DC Bus Voltage control in DC Microgrid (DC 마이크로그리드의 DC 버스 전압제어를 위한 Interlinking 컨버터의 PI-IP 혼합제어기 설계 및 분석)

  • Kim, Tae-Gyu;Lee, Hoon;Choi, Bong-Yeong;Kang, Kyung-Min;Kim, Mina;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.144-145
    • /
    • 2019
  • This paper proposes a design and analysis for a PI-IP hybrid voltage controller with a combination of PI and IP voltage controller for stable voltage control of DC bus voltage, Transient characteristic of DC bus voltage is improved by designed setting variable value and control method in the variable load and power generation conditions.

  • PDF

A Seamless Control Method for Supercapacitor to Compensate Pulse Load Transients in DC Microgrid

  • Dam, Duy-Hung;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.198-199
    • /
    • 2017
  • This paper proposed a new control method for supercapacitor (SC) to compensate the pulse load transient and enhance the power quality of dc microgrid. By coordinating the operation frequency, the supercapacitor is controlled to handle the surge current component while the low-frequency current component is dealt with by remaining sources in the system. Based on the state of charge and dc bus voltage level, the SC unit operation mode is automatically decided. Meanwhile, the dc bus voltage level indicates the power demand of the whole system; by regulating the dc bus voltage, the mismatch of power demand is covered by SC unit. The effectiveness of proposed method is verified by experiment prototype formed by two distributed generation and one supercapacitor unit.

  • PDF

A simple method to optimize DC-bus capacitor in 3-phase shunt Active power filter system

  • Phan, Dang-Minh;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.367-368
    • /
    • 2015
  • This paper introduces a shunt active power filter with a small DC bus capacitor by adding additional low-pass filter (LPF). The DC link voltage fluctuation is impressively suppressed with a small value in spite of the low value of DC-link capacitor under the steady-state condition. Consequently, the cost and volume of power converter are significantly reduced thanks to the reduced value of DC-bus capacitor. On the other hand, an indirect control strategy is used to maintain grid-side current when non-linear loads are connected to the system. By using proportional-integral (PI) and modified repetitive controller (RC) in dq0 frame, the calculation time is greatly decreased by 6 times compared with the conventional RC, and the number of measurement devices is also minimized. As a result, the acquired total harmonic distortion (THD) is lower than 2% regardless of the load conditions. Simulation results are carried out in order to verify the effectiveness of the proposed control strategy.

  • PDF

Redundant Operation of a Parallel AC to DC Converter via a Serial Communication Bus

  • Kanthaphayao, Yutthana;Kamnarn, Uthen;Chunkag, Viboon
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.533-541
    • /
    • 2011
  • The redundant operation of a parallel AC to DC converter via a serial communication bus is presented. The proposed system consists of three isolated CUK power factor correction modules. The controller for each converter is a dsPIC30F6010 microcontroller while a RS485 communication bus and the clock signal are used for synchronizing the data communication. The control strategy of the redundant operation relies on the communication of information among each of the modules, which communicate via a RS485 serial bus. This information is received from the communication checks of the converter module connected to the system to share the load current. Performance evaluations were conducted through experimentation on a three-module parallel-connected prototype, with a 578W load and a -48V dc output voltage. The proposed system has achieved the following: the current sharing is quite good, both the transient response and the steady state. The converter modules can perform the current sharing immediately, when a fault is found in another converter module. In addition, the transient response occurs in the system, and the output voltages are at their minimum overshoot and undershoot. Finally, the proposed system has a relatively simple implementation for the redundant operation.

Optimal Design of a DC-DC Converter for Photovoltaic Generation

  • Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.3
    • /
    • pp.40-49
    • /
    • 2011
  • This paper presents novel circuit topology of half-bridge soft-switching PWM inverter type DC-DC high power converter for DC bus feeding power plants. The proposed DC-DC power converter is composed of a typical voltage source-fed, half-bridge high frequency PWM inverter with a high frequency planar transformer link PWM control scheme and parallel capacitive lossless snubbers. The operating principle of the new DC-DC converter treated here is described by using switching mode-equivalent circuits, together with its unique features. All the active power switches in the half-bridge arms and input DC bus lines can achieve ZCS turn-on and ZVS turn-off commutation transitions. The total turn-off switching losses of the power switches can be significantly reduced. As a result, high switching frequency IGBTs can actually be selected in the frequency range of 40[kHz] under the principle of soft-switching. The performance evaluations of the experimental setup are illustrated practically.

Sensorless measurement of the DC link capacitor current of three-phase inverter (3상 인버터의 DC 링크 커패시터 전류의 센서리스 측정)

  • Qiu, Xiao-Dong;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.205-206
    • /
    • 2012
  • A general method to measure the inverter DC bus capacitor current is described. It is an indirect estimated method. By measuring the input and out voltage and current can calculate DC bus capacitor current. This paper will develope the theory that describes the indirect method. It will discuss and verify the feasibility of this approach through the use of the PSIM. Using SPWM control method will be simulated and compared.

  • PDF

DC Microgrid Operational Method for Enhanced Service Reliability Using DC Bus Signaling

  • Hwang, Pyeong-Ik;Jang, Gilsoo;Pyo, Gi-Chan;Han, Byung-Moon;Moon, Seung-Il;Ahn, Seon-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.452-464
    • /
    • 2015
  • This paper proposes a DC microgrid operational strategy and control method for improved service reliability. The objective is to supply power to as many non-critical loads as possible, while providing an uninterrupted power supply to critical loads. The DC bus signaling method, in which DC voltage is an information carrier, is employed to implement the operational strategy in a decentralized manner. During grid-connected operation, a grid-tied converter balances the power of the microgrid by controlling the DC voltage. All loads are connected to the microgrid, and operate normally. During islanded operation, distributed generators (DGs), a backup generator, or an energy storage system balances the power. However, some non-critical loads may be disconnected from the microgrid to ensure the uninterrupted power supply to critical loads. For enhanced service reliability, disconnected loads can be automatically reconnected if certain conditions are satisfied. Control rules are proposed for all devices, and detailed microgrid operational modes and transition conditions are then discussed. Additionally, methods to determine control parameter settings are proposed. PSCAD/EMTDC simulation results demonstrate the performance and effectiveness of the proposed operational strategy and control method.

A study on the radiated emission from the DC power-bus for the PCB (PCB DC power-bus로부터의 전파방사에 관한 연구)

  • Kahng, Sung-Tek
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.149-152
    • /
    • 2005
  • The DC power-bus' resonance is frequently attributed to EMI sources in the PCBs. Subsequently, it will ruin the digital signal integrity within one system or between adjacent systems in the form of conducted or radiated emission. Hence, since it is of importance to examine the PCB's emission, this paper sheds a light on the radiated emission from the power-bus with regards to its resonance modes. A full-wave analysis method is used to calculate the impedance and radiated electric fields and is validated by physics and an EM analysis tool.

  • PDF

DC Bus Communication Strategy for DC Microgird Using Pulse Frequency Modulation of Power Converter (DC 마이크로 그리드를 위한 컨버터 주파수 변동 제어 전략)

  • Choi, Hyun-Jun;Lee, Won-bin;Jung, Jee-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.207-208
    • /
    • 2016
  • 본 논문에서는 DC 마이크로그리드(MG) 동작의 신뢰성 및 안정성을 향상시키기 위하여, 주파수 변동을 이용한 새로운 DC bus signaling (DBS) 전략을 제안하고자 한다. 제안한 DBS의 경우 스위칭 리플을 사용하여, DC 버스를 통해 연결된 컨버터 등의 소자가 현재 DC bus의 전력에 대한 정보를 얻을 수 있다. DC bus의 전력의 정보는 소비와 생산에 대한 DC bus의 밸런스를 맞추기 위해 사용되고, 이를 통해 각각의 컨버터 동작 영역이 상황에 따라 자동적으로 결정되고, 궁극적으로 자율화 시스템을 구현할 수 있게 된다. 본 논문에서는 DC bus에 나타나는 주파수 성분의 분석 및 변동 전략에 대해 기술하고, 시뮬레이션 및 실험 결과를 통해 제안하고자 하는 알고리즘이 Power Line Communication (PLC) 으로의 가능성과 타당성을 점검하고자 한다.

  • PDF