• 제목/요약/키워드: DC bus

검색결과 271건 처리시간 0.019초

휠 디스크 스피닝 성형기 개발 (Development of the Wheel Disc Spinning Machine)

  • 강정식;강이석;이향수
    • 한국정밀공학회지
    • /
    • 제16권6호
    • /
    • pp.58-65
    • /
    • 1999
  • The spinning machine has been developed for a bus and truck wheel disc which is manufactured by spinning process method. This machine has the mechanical structure with bed, 2-column, cross head, 2-vertical slide, 2-horizontal slide with forming roller, clamp slide and main spindle similar to large size vertical lathe. Main spindle attached the mandrel is rotated about 500rpm drived by 280kW power DC motor, and a rotating black material pressed on the mandrel with the clamp slide is spinformed by 2-forming rollers which are attached inner end of the 2-horizontal slides. The 2-vertical and 2-horizontal slides are actuated by the hydraulic cylinder which is controlled by the servo valve individially, and these servo valves are controlled by control signal of the CNC controller which is computed with position signal feedbacked from the encoder sensor. The developed machine can manufacture wheel disc of various section profile without mandrel change because section profile is easily modified using program editing in the CNC controller processor. The wheel disc manufactured by spinning process method has many advantages that the endurance is increased by 2 times and the weight is decreased by 30% compared with a conventional disc.

  • PDF

EMTDC를 이용한 시뮬레이터급 통합전력제어기의 설계 (The Design of UPFC simulator by using EMTDC)

  • 전진홍;송의호;김지원;전영환;김학만;국경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.374-376
    • /
    • 2001
  • FACTS technology is developed into the sophisticated system technology which combines conventional power system technology with power electronics, micro-process control, and information technology. Its objectives are achieving enhancement of the power system flexibility and maximum utilization of the power transfer capability through improvements of the system reliability, controllability, and efficiency[1]. As a series and shunt compensator, UPFC consists of two inverters with common dc link capacitor bank. It controls the magnitude of shunt bus voltage and real and reactive power flow of transmission line[2]. In this paper, we present the design and control algorithm of UPFC simulator for KERI simulator. As a control algorithm is implemented by digital controller, we consider sample-and-hold of signals In this simulation, we use EMTDC/PSCAD V3.0 software which can simulate instantaneous voltage and current.

  • PDF

Cell-balancing Algorithm for Paralleled Battery Cells using State-of-Charge Comparison Rule

  • La, Phuong-Ha;Choi, Sung-Jin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.156-158
    • /
    • 2018
  • The inconsistencies between paralleled battery cells are becoming more considerable issue in high capacity battery applications like electric vehicles. Due to differences in state-of-charge (SOC) and internal resistance within individual cells in parallel, charging or discharging current is not appropriately balanced to each cell in terms of SOC, which may shorten the lifetime or sometimes cause safety issues. In this paper, an intelligent cell-balancing algorithm is proposed to overcome the inconsistency issue especially for paralleled battery cells. In this scheme, SOC information collected in the sub-BMS module is sent to the main-BMS module, where the number of parallel cells to be connected to DC bus is continuously updated based on the suggested SOC comparison rule. To verify the method, operation of the algorithm on 4 paralleled battery cells are simulated on Matlab/Simulink. The simulation result shows that the SOCs of paralleled cells are evenly redistributed. It is expected that the proposed algorithm provides high reliable and prolong the life cycle and working capacity of the battery pack.

  • PDF

경희대학교 천문대 30인치 주망원경 TCS 소프트웨어 개발 (DEVELOPMENT OF THE SOFTWARE FOR 30INCH TELESCOPE CONTROL SYSTEM AT KHAO)

  • 문병식;김상준;장민환;민상웅;설경환;문기석
    • 천문학논총
    • /
    • 제21권2호
    • /
    • pp.81-86
    • /
    • 2006
  • Even though 30inch optical telescope at Kyung Hee Astronomy Observatory has been used to produce a series of scientific achievements since its first light in 1992, numerous difficulties in operating of the telescope have hindered the precise observations needed for further researches. Since the currently used PC-TCS(Personal Computer based Telescope Control System) software based on ISA-bus type is outdated, it doesn't have a user friendly interface and make it impossible to scale. Also accumulated errors which are generated by discordance from input and output signals into a motion controller required new control system. Thus we have improved the telescope control system by updating software and modifying mechanical parts. We applied a new BLDC(brushless DC) servo motor system to the mechanical parts of the telescope and developed a control software using Visual Basic6.0. As a result, we could achieve a high accuracy in controlling of the telescope and use the user friendly GUI(Graphic User Interface).

다기 전력 시스템 동적 안정도 향상을 위한 분산 제어 기반 PSS 및 TCSC 제어기 설계 (The Analysis of Vibration Due to Magnetic Exciting Force in the Brushless DC Motor)

  • 이승철;서장철;문승일;박종근
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권1호
    • /
    • pp.13-19
    • /
    • 2001
  • This paper deals with decentralized control scheme and its application to multi-machine power systems. Decentralized control scheme has several practical advantages, because power system has geographically distributed characteristics. In this paper, decentralized observer-based optimal Power System Stabilizer(PSS) and Thyristor-Controlled Series Capacitor(TCST) controller are designed and tested in WSCC 9 bus system with one TCSC installed. Simulation results show that the proposed decentralized controller has satisfactory performances comparable to the centralized controller. In addition, using modal analysis, this paper shows that the proposed decentralized controller significantly affects only one pair of eigenvalues which have high participation with each generator, while slightly affects other eigenvalues. This result indicates that the application of the decentralized control scheme to enhance power system dynamic stability via excitation control have potential advantages because each low-damped mode occurs dominantly by each decentralized subsystem.

  • PDF

Combined Design of PSS and STATCOM Controllers for Power System Stability Enhancement

  • Rohani, Ahmad;Tirtashi, M. Reza Safari;Noroozian, Reza
    • Journal of Power Electronics
    • /
    • 제11권5호
    • /
    • pp.734-742
    • /
    • 2011
  • In this paper a robust method is presented for the combined design of STATCOM and Power System Stabilizer (PSS) controllers in order to enhance the damping of the low frequency oscillations in power systems. The combined design problems among PSS and STATCOM internal ac and dc voltage controllers has been taken into consideration. The equations that describe the proposed system have been linearized and a Fuzzy Logic Controller (FLC) has been designed for the PSS. Then, the Particle Swarm Optimization technique (PSO) which has a strong ability to find the most optimistic results is employed to search for the optimal STATCOM controller parameters. The proposed controllers are evaluated on a single machine infinite bus power system with the STATCOM installed in the midpoint of the transmission line. The results analysis reveals that the combined design has an excellent capability in damping a power system's low frequency oscillations, and that it greatly enhances the dynamic stability of power systems. Moreover, a system performance analysis under different operating conditions and some performance indices studies show the effectiveness of the combined design.

Fault Tolerant Operation of CHB Multilevel Inverters Based on the SVM Technique Using an Auxiliary Unit

  • Kumar, B. Hemanth;Lokhande, Makarand M.;Karasani, Raghavendra Reddy;Borghate, Vijay B.
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.56-69
    • /
    • 2018
  • In this paper, an improved Space Vector Modulation (SVM) based fault tolerant operation on a nine-level Cascaded H-Bridge (CHB) inverter with an additional backup circuit is proposed. Any type of fault in a power converter may result in a power interruption and productivity loss. Three different faults on H-bridge modules in all three phases based on the SVM approach are investigated with diagrams. Any fault in an inverter phase creates an unbalanced output voltage, which can lead to instability in the system. An additional auxiliary unit is connected in series to the three phase cascaded H-bridge circuit. With the help of this and the redundant switching states in SVM, the CHB inverter produces a balanced output with low harmonic distortion. This ensures high DC bus utilization under numerous fault conditions in three phases, which improves the system reliability. Simulation results are presented on three phase nine-level inverter with the automatic fault detection algorithm in the MATLAB/SIMULINK software tool, and experimental results are presented with DSP on five-level inverter to validate the practicality of the proposed SVM fault tolerance strategy on a CHB inverter with an auxiliary circuit.

Utilization of Active Diodes in Self-powered Sensorless Three-phase Boost-rectifiers for Energy Harvesting Applications

  • Tapia-Hernandez, Alejandro;Ponce-Silva, Mario;Olivares-Peregrino, Victor Hugo;Valdez-Resendiz, Jesus Elias;Hernandez-Gonzalez, Leobardo
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.1117-1126
    • /
    • 2017
  • The main contribution of this paper is the use of sensorless active diodes to generate the gate signals for a three-phase boost-rectifier with a self-powered control scheme. The sensorless operation is achieved making use of the gate control signals generated by the active diode schemes on each of the switching devices using a pulse width half-controlled boost rectifier modulation technique (PWM-HCBR). The proposed scheme synchronizes the gate control signals with a three phase voltage supply. Autonomous operation is obtained making use of the output DC bus to feed the control circuitry, the active diodes and the driver circuitry. The three-phase boost-rectifier is supplied by a three-phase permanent magnet electric generator powered by a solar concentrator dish with variable voltage and variable frequency conditions. Experimental results report an efficiency of up to 94.6% for 25 W and an input of 3.6 V peak per phase with 450.

회생전력 제어용 인버터 시스템의 구현에 관한 연구 (A Study on the Implementation of Inverter Systems for Regenerated Power Control)

  • 金 敬 源;徐 永 泯;洪 淳 瓚
    • 전력전자학회논문지
    • /
    • 제7권2호
    • /
    • pp.205-213
    • /
    • 2002
  • 본 논문에서는 직류모선에서 교류모선으로 회생되는 전력을 제어할 수 있는 3상 전압원 인버터 시스템을 구현하였다. 전체 시스템은 선간접압 및 선전류용 센서, d-q 변환방식을 사용한 실제전력 연산기. PI제어기법을 적용한 복소전력 제어기, 수정 q도통방식을 구현하기 위한 게이팅신호 생성기, 주파수를 추종하기 위한 DPLL과 전력회로로 구성된다. 제어보드는 32비트 DSP인 TMS32C32, EFLD 2개, ACD 6개와 DAC로 구성하였다. 제안한 시스템의 성능을 검증하기 위해 교류 220V에서 5kVA 전력용량인 축소모델을 설계, 제작하였다. 실험결과, 회생 유효전력은 명령값으로 잘 제어되며 회생 무효전력은 운전동안 내내 거의 0의 값을 유지함을 확인하였다.

아리랑1호 위성 ETB의 전도성 전자파 환경 시험결과 분석 (A Analysis on the Result of CE/CS Test on the KOMPSAT-I ETB)

  • 임성빈;천용식
    • 한국전자파학회논문지
    • /
    • 제12권2호
    • /
    • pp.184-192
    • /
    • 2001
  • 본 논문에서는 아리랑 1호 개발단계에서 위성의 전기/전자적 기능 시험을 수행하기 위해 개발 모델로 구성된 Electrical Test Bed(ETB) 플랫폼에서 수행한 전도성 방출 및 전도성 감응시험 결과를 분석하였다. 전도성 전자파환경시험은 전력공급장지(Power control unit)로부터 위성을 구성하고 있는 각각의 하드웨어와DC 전원을 공급하기 위하여 스위치가 동작하는 순간, 전력 및 신호선을 통하여 전달하게 될 노이즈의 순시 파형을 시간 영역에서 측정하고, 모든 하드웨어에 전력이 공급되어 정상상태로 동작하는 동안에 발생하는 노이즈특성을 시간영역과 주파수 영역에서의 스펙트럼을 10 Hz에서 100hz까지 스캐닝하여 그 레벨을 측정하여 결과를 분석한 결과를 이용하여 6 dB이상의 시스템 마진을 더한 결과를 노이즈 소스로 공급하여 하드웨어의 오동작 및 하드웨어의 손상이 없음을 검증하였다. 본 시험은 아리랑 1호 위성의 공동개발을 수행한 미국 TRW 사의 위성체 조립시험장에서 수행되었다.

  • PDF