• 제목/요약/키워드: DC Generator

검색결과 398건 처리시간 0.021초

Analysis and Design of Resonant Inverter for Reactive Gas Generator Considering Characteristics of Plasma Load

  • Ahn, Hyo Min;Sung, Won-Yong;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.345-351
    • /
    • 2018
  • This paper analyzes a resonant inverter to generate plasma. The resonant inverter consists of a full bridge converter, resonant network and reactor to generate a magnetic field for plasma generation. A plasma load has very distinct characteristics compared to conventional loads. The characteristics of plasma load are analyzed through experimental results. This paper presents the study on the resonant network, which was performed in order to determine how to achieve a constant current gain. Another important contribution of this study is the analysis of drop-out phenomenon observed in plasma loads which is responsible for unpredictable shutdown of the plasma generator that requires stable operation. In addition, the design process for the resonant network of a plasma generator is proposed. The validity of this study is verified through simulations and experimental results.

Performance Improvement of the Linear BLDC Generator in a NASA Deep Space Explorer

  • Lee, Hyung-Woo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권3호
    • /
    • pp.108-113
    • /
    • 2004
  • This paper presents methods to improve performance of the power supply system in a NASA deep space explorer. In the Stirling engine driven reciprocating Brushless DC (BLDC) generator, the accurate position information of the prime mover is important to diagnose the performance of the engine and prevent distortion of the output power. Since sensors to detect the position are fragile and unreliable, and conventional sensorless techniques have drawbacks in the low speed region, a novel sensorless position detection technique for the prime mover has been proposed and verified. Another major issue of the generator for the spacecraft is power density maximization. The mass of the power system is important to the mass of the satellite. Therefore, the components of the spacecraft should be lightweight. Conventional rectification methods cannot achieve the maximum power possible due to non-optimal current waveforms. The optimal current waveform for maximizing power density and minimizing machine size and weight in a nonsinusoidal power supply system has been derived, incorporated in a control system, and verified by simulation work.

소형 전자기기를 위한 스위치드 커패시터 방식의 강압형 DC-DC 변환기 설계 (Design of Step-down DC-DC Converter using Switched-capacitor for Small-sized Electronics Equipment)

  • 권보민;허윤석;송한정
    • 한국산학기술학회논문지
    • /
    • 제11권12호
    • /
    • pp.4984-4990
    • /
    • 2010
  • 기존의 DC-DC Converter에서는 전압 변화 및 에너지 축적소자로서 자성부품인 인덕터를 사용하여 자속 발생에 의한 전력 손실로 효율이 낮아지고, 자성부품의 부피가 크고 무거우며 가격이 비싸 반도체 칩으로 집적화하기에 문제점을 가지고 있다. 이러한 문제점을 개선하기 위해 본 논문에서는 인덕터없는 스위치드 커패시터 방식을 이용한 저전력 강압형 CMOS DC-DC Converter를 제안한다. 제안된 DC-DC Converter는 0.5um 공정을 이용하여 설계하였으며, 설계된 DC-DC 컨버터는 200kHz의 주파수로 동작하며 96%이상의 전력효율을 cadence 시뮬레이션을 통하여 얻을 수 있다.

풍력발전용 농형유도발전기의 최대출력제어 (Maximum Output Control of Cage-Type Induction Generator for Wind Power Generation)

  • 구성영;이동춘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.288-292
    • /
    • 2001
  • In this paper, a maximum power control of a low-cost and rugged cage-type induction generator system is proposed, where the machine-side PWM converter is used for maximum power generation and field excitation control, and the line-side PWM inverter is used for the dc link voltage control and source-side power factor control. Simulation results through Matlab Simulink have been demonstrated.

  • PDF

A Novel type of High-Frequency Transformer Linked Soft-Switching PWM DC-DC Power Converter for Large Current Applications

  • Morimoto Keiki;Ahmed Nabil A.;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.216-225
    • /
    • 2006
  • This paper presents a new circuit topology of DC busline switch and snubbing capacitor-assisted full-bridge soft-switching PWM inverter type DC-DC power converter with a high frequency link for low voltage large current applications as DC feeding systems, telecommunication power plants, automotive DC bus converters, plasma generator, electro plating plants, fuel cell interfaced power conditioner and arc welding power supplies. The proposed power converter circuit is based upon a voltage source-fed H type full-bridge high frequency PWM inverter with a high frequency transformer link. The conventional type high frequency inverter circuit is modified by adding a single power semiconductor switching device in series with DC rail and snubbing lossless capacitor in parallel with the inverter bridge legs. All the active power switches in the full-bridge inverter arms and DC busline can achieve ZVS/ZVT turn-off and ZCS turn-on commutation operation. Therefore, the total switching losses at turn-off and turn-on switching transitions of these power semiconductor devices can be reduced even in the high switching frequency bands ranging from 20 kHz to 100 kHz. The switching frequency of this DC-DC power converter using IGBT power modules is selected to be 60 kHz. It is proved experimentally by the power loss analysis that the more the switching frequency increases, the more the proposed DC-DC converter can achieve high performance, lighter in weight, lower power losses and miniaturization in size as compared to the conventional hard switching one. The principle of operation, operation modes, practical and inherent effectiveness of this novel DC-DC power converter topology is proved for a low voltage and large current DC-DC power supplies of arc welder applications in industry.

DC Microgrid Operational Method for Enhanced Service Reliability Using DC Bus Signaling

  • Hwang, Pyeong-Ik;Jang, Gilsoo;Pyo, Gi-Chan;Han, Byung-Moon;Moon, Seung-Il;Ahn, Seon-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.452-464
    • /
    • 2015
  • This paper proposes a DC microgrid operational strategy and control method for improved service reliability. The objective is to supply power to as many non-critical loads as possible, while providing an uninterrupted power supply to critical loads. The DC bus signaling method, in which DC voltage is an information carrier, is employed to implement the operational strategy in a decentralized manner. During grid-connected operation, a grid-tied converter balances the power of the microgrid by controlling the DC voltage. All loads are connected to the microgrid, and operate normally. During islanded operation, distributed generators (DGs), a backup generator, or an energy storage system balances the power. However, some non-critical loads may be disconnected from the microgrid to ensure the uninterrupted power supply to critical loads. For enhanced service reliability, disconnected loads can be automatically reconnected if certain conditions are satisfied. Control rules are proposed for all devices, and detailed microgrid operational modes and transition conditions are then discussed. Additionally, methods to determine control parameter settings are proposed. PSCAD/EMTDC simulation results demonstrate the performance and effectiveness of the proposed operational strategy and control method.

2차 Space Dithered Sigma-Delta Modulation 기반의 Random PWM 스위칭 기법을 이용한 강압형 DC-DC 컨버터의 성능 개선 (Performance Improvement of a Buck Converter using a End-order Space Dithered Sigma-Delta Modulation based Random PWM Switching Scheme)

  • 김서형;주성탁;정해광;이교범;정규범
    • 전력전자학회논문지
    • /
    • 제14권1호
    • /
    • pp.54-61
    • /
    • 2009
  • 본 논문에서는 강압형 DC-DC 컨버터의 성능 개선을 위한 스위칭 기법인 2차 SDSDM (Space Dithered Sigma Delta Modulation)방식을 제안한다. PWM (Pulse Width Modulation) 방식은 일정 스위칭 주파수 대역에서의 고조파로 인해 소음, 전자파 장애, 스위칭 손실 등을 유발한다. 이러한 문제를 해결하기 위한 DSDM 방식의 일종인 1차 SDSDM은 랜덤 디더(Random Dither) 발생기가 1차 SDM의 양자화기(quatizer) 입력단에 위치하여 스위칭 주파수가 분산된다. 강압형 DC/DC 컨버터에 제안하는 2차 SDSDM의 방식을 적용한 실험 결과를 통해 타당성을 검증한다.

스마트 사물인터넷 기기용 저리플 방식의 스텝다운 컨버터 분석 (Analysis of Step-Down Converter with Low Ripple for Smart IoT Devices)

  • 김다솔;알라딘;구진선;쿠마르;송한정
    • 한국산업융합학회 논문집
    • /
    • 제24권5호
    • /
    • pp.641-644
    • /
    • 2021
  • Wearable devices and IoT are being utilized in various fields, where all systems are developing in the direction of multi-functionality, low power consumption, and high speed. In this paper, we propose a DC -DC Step-down C onverter for IoT smart devices. The proposed DC -DC Step-down converter is composed of a control block of the power supply stage. It also consists of an overheat protection circuit, under-voltage protection circuit, an overvoltage protection circuit, a soft start circuit, a reference voltage circuit, a lamp generator, an error amplifier, and a hysteresis comparator. The proposed DC-DC converter was designed and fabricated using a Magnachip / Hynix 180nm CMOS process, 1-poly 6-metal, the measured results showed a good match with the simulation results.

Design Considerations for Low Voltage Claw Pole Type Integrated Starter Generator (ISG) Systems

  • Lee, Geun-Ho;Choi, Geo-Seung;Choi, Woong-Chul
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.527-532
    • /
    • 2011
  • Due to the need for improved fuel consumption and the trend towards increasing the electrical content in automobiles, integrated starter generator (ISG) systems are being considered by the automotive industry. In this paper, in order to change the conventional generator of a vehicle, a belt driven integrated starter generator is considered. The overall ISG system, the design considerations for the claw pole type AC electric machine and a low voltage very high current power stage implementation are discussed. Test data on the low voltage claw pole type machine is presented, and a large current voltage source DC/AC inverter suitable for low voltage integrated starter generator operation is also presented. A metal based PCB (Printed Circuit Board) power unit to attach the 4-parallel MOS-FETs is used to achieve extremely high current capability. Furthermore, issues related to the torque assistance during vehicle acceleration and the generation/regeneration characteristics are discussed. A prototype with the capability of up to 1000 A and 27 V is designed and built to validate the kilo-amp inverter.

수력 발전기의 운전중 부분방전 측정기법에 대한 신뢰성 평가 (Evaluation of On-Line Partial Discharge Measurement Techniques on Hydro-Generator)

  • 황돈하;김진봉;김용주;박명수;김택수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1526-1529
    • /
    • 1994
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the end winding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current test and ${\Delta}tan{\delta}$ test has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot discharges may not be found with off-line diagnoses. This paper describes the on-line partial discharge measurement techniques in the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF