• 제목/요약/키워드: DC Electrical Potential Method

검색결과 45건 처리시간 0.025초

자동차 연료펌프용 BLDC 전동기구동의 센서리스 제어기법 (Control Techniques of Sensorless BLDC Motor Drive for a Vehicle Fuel Pump Application)

  • 트란 콴 빈;전태원;이홍희;김흥근;노의철
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1858-1864
    • /
    • 2011
  • This paper suggests a control technique of the sensorless brushless DC (BLDC) motor drive for a vehicle fuel pump application. The sensorless technique based on a comparator and a potential start-up method with high starting torque are proposed. The comparator is used to generate the commutation signals in phase with the three-phase back-EMFs. The rotor position is aligned at standstill for maximum starting torque without an additional sensor and any information of motor parameters. Also, the stator current can be easily adjusted by modulating the pulse width of the switching devices during alignment. Some experiments are implemented on a single chip 16-bit DSP controller to demonstrate the feasibility of the sensorless techniques.

Development of A Floating Solar Thermoelectric Generator Using A Dome Shaped Fresnel Lens for Ocean Application

  • Seong-Hoon Kim;Jeung-Sang Go
    • 한국산업융합학회 논문집
    • /
    • 제26권6_1호
    • /
    • pp.1001-1010
    • /
    • 2023
  • To solve the problem that photovoltaic panels can not harvest electrical energy at a cloudy day and night, a floating solar thermoelectric generator (FSTEG, hereafter) is studied. The FSTEG is consisted of a dome shaped Fresnel lens to condense solar energy, a thermoelectric module connected with a heat sink to keep temperature difference, a floating system simulating a wavy ocean and an electrical circuit for energy storage. The dome shaped Fresnel lens was designed to have 29 prisms and its optical performance was evaluated outdoors under natural sunlight. Four thermoelectric modules were electrically connected and its performance was evaluated. The generated energy w as stored in a Li-ion battery by using a DC-DC step-up converter. For the application of ocean environment, the FSTEG was covered by the dome shaped Fresnel lens and sealed to float in a water-filled reservoir. The harvested energy shows a potential and a method that the FSTEG is suitable for the energy generation in the ocean environment.

Switched Reluctance Motor와 Brushless DC Motor의 공극 변화에 따른 출력 특성 비교 (Analysis of Output Characteristic in accordance with Airgap Variation in Switched Reluctance Motor and Brushless DC Motor)

  • 윤찬호;박금구;이종찬;전연도;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.843-845
    • /
    • 2001
  • In this paper, we analyze the characteristics of electecromotive force(emf), phase current and torque according to the length of the air gap using 2nd order FEM(Finite Element Method) in Synchronous Reluctance Motor(SRH) and Brushless DC Motor(BLDC) with same volume and size. In the analysis with FEM, we applied the time-step function considering the motor switch in the magnetic vector potential of the unknown node.

  • PDF

Natural Balancing of the Neutral Point Potential of a Three-Level Inverter with Improved Firefly Algorithm

  • Gnanasundari, M.;Rajaram, M.;Balaraman, Sujatha
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1306-1315
    • /
    • 2016
  • Modern power systems driven by high-power converters have become inevitable in view of the ever increasing demand for electric power. The total power loss can be reduced by limiting the switching losses in such power converters; increased power efficiency can thus be achieved. A reduced switching frequency that is less than a few hundreds of hertz is applied to power converters that produce output waveforms with high distortion. Selective harmonic elimination pulse width modulation (SHEPWM) is an optimized low switching frequency pulse width modulation method that is based on offline estimation. This method can pre-program the harmonic profile of the output waveform over a range of modulation indices to eliminate low-order harmonics. In this paper, a SHEPWM scheme for three-phase three-leg neutral point clamped inverter is proposed. Aside from eliminating the selected harmonics, the DC capacitor voltages at the DC bus are also balanced because of the symmetrical pulse pattern over a quarter cycle of the period. The technique utilized in the estimation of switching angles involves the firefly algorithm (FA). Compared with other techniques, FA is more robust and entails less computation time. Simulation in the MATLAB/SIMULINK environment and experimental verification in the very large scale integration platform with Spartan 6A DSP are performed to prove the validity of the proposed technique.

전기비저항 토모그래피와 시추공 레이다 탐사의 원리 및 응용 (Principles and application of DC resistivity tomography and borehole radar survey.)

  • 김정호;이명종;조성준;송윤호;정승환
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 1999년도 제2회 학술발표회
    • /
    • pp.92-116
    • /
    • 1999
  • 전기, 전자 토모그래피는 전기적인 물성을 이용하여 지하의 고분해능 영상을 획득하는 방법이며 주파수에 의하여 전기비저항, 전자탐사, 레이다 토모그래피로 나뉘어진다. 이들 중 전기비저항, 레이다 토모그래피는 최근 들어 국내에서도 특히 지반조사 분야에서 활발하게 이용되기 시작하고 있다 본 논문에서는, 전기, 전자 토모그래피 법 중 국내에서 사용되는 전기비저항 토모그래피 및 레이다 토모그래피를 포함한 시추공을 이용한 레이다 탐사의 원리 및 적용에 대하여 국내의 탐사 사례를 중심으로 논하였다. 특히 시추공을 이용한 레이다 탐사의 방법론적인 접근에 있어서는, 방향탐지 안테나를 이용한 레이다 반사법 탐사법과 이방성 토모그래피 문제가 석산 탐사 및 지반조사 사례를 이용하여 논의되었다 한편 전기비저항 토모그래피에서는 각종의 전극 배열의 장단점이 논의되었으며, 전기전도도가 높은 시추공 공내수 내에 전극이 위치하기 때문에 발생하는 시추공 효과에 대하여 설명하였다. 대부분의 사례들은 알려져 있는 지질 정보, 시추코아 검층자료, 텔레뷰어 등의 자료와 비교하여 논의하였다.

  • PDF

A Novel Modulation Method for Three-Level Inverter Neutral Point Potential Oscillation Elimination

  • Yao, Yuan;Kang, Longyun;Zhang, Zhi
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.445-455
    • /
    • 2018
  • A novel algorithm is proposed to regulate the neutral point potential in neutral point clamped three-level inverters. Oscillations of the neutral point potential and an unbalanced dc-link voltage cause distortions of the output voltage. Large capacitors, which make the application costly and bulky, are needed to eliminate oscillations. Thus, the algorithm proposed in this paper utilizes the finite-control-set model predictive control and the multistage medium vector to solve these issues. The proposed strategy consists of a two-step prediction and a cost function to evaluate the selected multistage medium vector. Unlike the virtual vector method, the multistage medium vector is a mixture of the virtual vector and the original vector. In addition, its amplitude is variable. The neutral point current generated by it can be used to adjust the neutral point potential. When compared with the virtual vector method, the multistage medium vector contributes to decreasing the regulation time when the modulation index is high. The vectors are rearranged to cope with the variable switching frequency of the model predictive control. Simulation and experimental results verify the validity of the proposed strategy.

Optical Properties of Multi-layer TiNO/AlCrNO/Al Cermet Films Using DC Magnetron Sputtering

  • Han, Sang-Uk;Park, Soo-Young;Kim, Hyun-Hoo;Jang, Gun-Eik;Lee, Yong-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권5호
    • /
    • pp.280-284
    • /
    • 2015
  • Among many the oxynitrides, TiNO and AlCrNO, have diverse applications in different technological fields. We prepared TiNO/AlCrNO/Al thin films on aluminum substrates using the method of dc reactive magnetron sputtering. The reactive gas flow, gas mixture, and target potential were applied as the sputtering conditions during the deposition in order to control the chemical composition. The multi-layer films have been prepared in an Ar and O2+N2 gas mixture rate. The surface properties were estimated by performing scanning electron microscopy (SEM). At a wavelength range of 0.3~2.5 μm, the exact composition and optical properties of thin films were measured by Auger electron spectroscopy (AES) and Ultraviolet-visible-near infrared (UV-Vis-NIR) spectrophotometry. The optimal absorptance of multi-layer films was exhibited above 95.5% in the visible region of the electromagnetic spectrum, and the reflectance was achieved below 1.89%.

전기비저항법을 이용한 재료열화 평가 (Evaluation of Material Degradation Using Electrical Resistivity Method)

  • 석창성;김동중;배봉국
    • 대한기계학회논문집A
    • /
    • 제24권12호
    • /
    • pp.2995-3002
    • /
    • 2000
  • The remaining life estimation for the aged components in power plants as well as chemical plants are very important beacuse mechanical properties of the components are degraded with time of service exposure in high temperature. Since it is difficult to take specimens from the operating components to evaluate mechanical properties of components nondestructive techniques are needed to estimate the degradation. In this study, test materials with 4 different degradation levels were prepared by isothermal aging heat treatment at 630$\^{C}$. And the DC potential drop method and destructive methods such as tensile, K(sub)IC and hardness tests were used in order to evaluate the degradation of 1-Cr-1Mo-0.25V steels. The objective of this study is to investigate the possibility of the application of DCPD method to estimated the material degradation, and to analyse the relationship between the electrical relationship between the electrical resistivity and the degree material degradation.

직류전기철도 전식대책 실증실험(1) 누설전류 배류시스템 (Field Test of Mitigation Methods for Stray Currents from DC Electric Railroad(1) Stray Current Drainage System)

  • 하윤철;배정효;하태현;이현구;김대경;최정희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.220-222
    • /
    • 2007
  • With the wide spread of direct current (DC) electric railroads in Korea, the stray currents or leakage currents from negative return rails become a pending problem to the safety of nearby underground infrastructures. The most widely used mitigation method for this interference is the stray current drainage method, which connects the underground metallic structures to the rails with diodes (polarized drainage) or thyristor (forced drainage). Although this method inherently possesses some drawbacks, its cost effectiveness and efficiency to protect the interfered structures has been the main reason for the wide adoption. In this paper, we show the field test results for the application of stray current drainage system to a city gas pipeline paralleling a depot area of a metropolitan rapid transit system. The process for optimal positioning is briefly illustrated. The effectiveness of constant voltage, constant current, and constant potential drainage schemes was also described.

  • PDF

Trichel Pulse in Negative DC Corona discharge and Its Electromagnetic Radiations

  • Zhang, Yu;Liu, Li-Juan;Miao, Jin-Song;Peng, Zu-Lin;Ouyang, Ji-Ting
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1174-1180
    • /
    • 2015
  • We investigate in this paper the radiated electromagnetic waves together with the discharge characteristics of Trichel pulse of negative DC corona discharge in air in pin-to-plate and wire-to-plate configurations. The feature of the current pulse and the frequency spectrum of the electromagnetic radiations were measured under various pressures and gas gaps. The results show that the repetition frequency and the amplitude of Trichel pulse current depend on the discharge conditions, but the rising time of the pulse relates only to the radius of needle or wire and keeps constant even if the other conditions (including the discharge current, the gas gap and the gas pressure) change. There exists the characterized spectrum of electromagnetic waves from negative corona discharge in Trichel pulse regime. These characterized radiations do not change their frequency at a given cathode geometry even if the averaged current, the gas gap or the air pressure changes, but the amplitude of radiations changes accordingly. The characterized electromagnetic radiations from Trichel pulse corona relate to the formation or the rising edge of current pulse. It confirms that the characterized radiations from Trichel pulse supply information of discharge system and provide a potential method for detecting charged targets.