• 제목/요약/키워드: DC Electric Field

검색결과 286건 처리시간 0.025초

선대 평판형 플라즈마 반응기에서 NOx 제거에 미치는 자계의 영향 (Effect of Magnetic Field on NOx Removal for Wire-Plate Plasma Reactor)

  • 박재윤;손성도;한상보;이동훈;김종달;문영훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2251-2252
    • /
    • 1999
  • In this paper, the effect of magnetic field was measured on NOx removal characteristics for wire-plate plasma reactor with magnetic field applied to electric field vertically. NOx from simulated diesel engine flue gas are decomposed by the corona discharge of DC, AC and Pulsed voltages in wire-plate reactor. Consumption power increased with increasing discharge voltage. When magnetic field was applied to electric field vertically, consumption power decreased. NOx removal rate and arc transition voltage of plasma reactor with magnetic field were higher than those of plasma reactor without magnetic field.

  • PDF

플라즈마 밀도와 기판의 기울임 정도에 따른 탄소나노튜브의 성장 (Synthesis of CNTs with Plasma Density and Tilt Degree of Substrate)

  • 최은창;김경욱;홍병유
    • 한국전기전자재료학회논문지
    • /
    • 제22권7호
    • /
    • pp.612-615
    • /
    • 2009
  • We need to control the growth orientation of CNTs on a substrate for applications to various electric devices. Generally, the flow direction of feed gases and electric field between two electrode affect to growth orientations of CNTs. In this paper, we varied tilt degrees $(0^{\circ},\;20^{\circ},\;35^{\circ},\;50^{\circ},\;65^{\circ},\;90^{\circ})$ of substrates on a cathode and DC bias voltages (0, 500, 700 V) applied between two electrodes in order to change growth orientations of CNTs. We confirmed that tilt degrees of the substrate and variation of DC bias voltages affected to the shape and orientation of the grown CNTs on the substrate.

전기철도용 피뢰기 선정에 관한 연구 (A Study on the Selection of Lightning Arrester for DC Electric Traction Vehicles)

  • 길경석;송재용;김일권;문승보;한주섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.581-586
    • /
    • 2006
  • Selection and application recommendations of lightning arresters for DC electric traction vehicles are presented. To decide arrester specification such as continuous operating voltage(COV, $U_c$), rated voltage($U_R$), and nominal discharge current($I_n$), variations of system voltage and surge currents flowing arresters were analyzed in running-service of traction vehicles. System voltages increased up to 1,800V during anti-breaking. Surge currents recorded 3 times per running-service-route and their magnitudes were ranges of $150A{\sim}2kA$. From the field measurement and consideration of EN50163, COV, $U_c$, and $U_R$ for the $1,500V_{DC}$ traction vehicles were proposed.

  • PDF

초고압 직류 가공 송전선로에서 발생되는 이온 계측시스템 개발 (The Development of System for Measuring Ion Generated from HVDC Overhead Transmission Line)

  • 주문노;양광호;이동일;신구용;임재섭
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.2035-2040
    • /
    • 2008
  • The electrical discharge of high voltage direct current(HVDC) overhead transmission line generate audible noise, radio noise, electric field, ion current and induced voltage on the ground. These items are major factors to design environmentally friendly configuration of DC transmission line. Therefore, HVDC transmission lines must be designed to keep all these corona effects within acceptable levels. Several techniques have been used to assess interference caused by ions on HVDC overhead transmission line. In this study, to assess the ion characteristic of DC line, the ion current density and induced voltage caused by ion flow were measured by plate electrodes manufactured from a metal flat board and charged bodies, respectively. The charged body has two types of cylinder and cylindrical plate. From the results of calibration experiments, the sensitivity of flat electrode and charged body can be obtained. At present, the developed system is used to investigate the ion generation characteristics of Kochang DC ${\pm}500kV$ test line.

공기중 전극형상에 따른 방사전자파의 주파수 분포특성 (Frequency Distribution Characteristics of Electromagnetic Waves in accordance with Electrode Shapes in Air)

  • 김충년;이상훈;지승욱;김기채;박원주;이광식;주재현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1878-1880
    • /
    • 2002
  • In this paper, electromagnetic waves radiated from discharge at three-type electrodes (needle-plane, plane-plane and sphere-plane electrode) using DC power source in air measured and the peculiar patterns of their spectra are reported. The radiated electrodmagnetic waves were measured in bandwidth of VHF($30{\sim}230$[MHz]) using a biconcal antenna and a spectrum analyzer. Frequency spectrum distribution of radiated electromagnetic wave was revealed under 50[MHz] at positive DC, and high electric field was shown at 45[MHz] frequency band. But, it was revealed under 70[MHz] frequency band at negative DC under plane-plane electrodes and sphere-plane electrodes, and high electric field was shown at 55 [MHz] frequency band.

  • PDF

HVDC 가공 송전선로 전기환경특성 모의시험용 코로나 케이지 계측시스템 개발 (Development of Corona Cage Measurement System for Simulation on Electrical Environmental Characteristics of HVDC Overhead Transmission Line)

  • 길경석;양광호;이성두;주문노
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권5호
    • /
    • pp.245-249
    • /
    • 2006
  • Corona characteristics of conductors are dependent on the electric field conditions in the immediate vicinity of the conductors. In case of DC transmission line, particularly, the space charge plays an important role in the electric field distribution. Therefore, DC corona cage simulation is necessary for long-term test in the same conditions. This paper presents the results of designing and constructing hardwares such as DC power supply, measurement system and DAS to carry out the simulation. The corona cage longitudinally is divided into five equal length sections and three inner sections of those are isolated from the ground of outer cage. The measurement items are radio noise, corona current, television noise, audible noise and meteorological conditions. In the next step, various simulations about the type and configuration of two or three candidate conductors will be conducted. And then finally an environmentally-friendly conductor for HVDC overhead transmission line will be decided.

인가 전압이 Y-TZP의 저온열화에 미치는 영향 (Influence of Applied Electric Field on Low Temperature Degradation of Y-TZP)

  • 장주웅;이홍림;김대준;오남식;이득용
    • 한국세라믹학회지
    • /
    • 제34권12호
    • /
    • pp.1254-1260
    • /
    • 1997
  • Influence of applied electric field on the low temperature degradation of 3 mol% YaO3 stabilized tetragonal zirconia polycrystals(3Y-TZP) was investigated using X-ray diffractometry of specimens aged under the dc field of 1.1 kV/mm in silicone oil both of 12$0^{\circ}C$-21$0^{\circ}C$. After the aging, the tetragonal to monoclinic phase transformation was observed only on the specimen surface of 3Y-TZP faced to the anode. This indicated that the surface was overcrowded with oxygen ions as a result of diffusion of oxygen vacancies toward the cathode-sided surface. To elucidate an influence of the applying time of the electric field on the extent of the degradation of 3Y-TZP in air, specimens were aged fore 0-2 hours under the electric field in the oil bath of 12$0^{\circ}C$ and then subsequently aged for 3h at 22$0^{\circ}C$ in air. The longer the specimens were aged under the field, the more extensive the transformation to the monoclinic phase was on the specimen surface faced to the cathode, probably originated from a high diffusion rate of oxygen ions due to a steep oxygen vacancy concentration gradient.

  • PDF

전극표면에서 액적의 충전현상과 이를 이용한 액적의 이동 방법에 관한 연구 (Research on the Electrical Charging of a Water Droplet on the Electrode and Droplet Actuation Method using Electrical Charge)

  • 정용미;오현창;강인석
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.666-669
    • /
    • 2008
  • Droplet in miniaturized microfluidic systems have received much focused attention recently. In this work, electrical charging phenomenon of a conducting water droplet on the electrode under the dc electric field is studied and using this phenomenon droplet actuation method for microreactor applications is experimentally demonstrated. To find effects of key factors, the effects of electric field, medium viscosity, and droplet size are investigated. A scaling law of charging for the conducting droplet is derived from the experimental results. Unlike the case of a perfect conductor, the estimated amount of electrical charge ($Q_{est}$) of a water droplet is proportional to the 1.59 power of the droplet radius (R) and the 1.33 power of the electric field strength (E). (For a spherical perfect conductor, Q is proportional to R2 and E.) It is thought that the differences are mainly due to incomplete charging of a water droplet resulted from the combined effect of electrochemical reaction at electrode and the relatively low conductivity of water. Using this phenomenon, we demonstrate the transport of the charged droplet and fusion of two oppositely-charged droplets. When electric field is subjected sequentially on the electrode, the charged droplet is transported on the electrode. For the visualization of fusion of charged droplets, the precipitation reaction is used. When subjected to a DC voltage, two droplets charged are moving and merging toward each other due to the Coulombic force and chemical reaction is simultaneously occurred by coalescence of droplets. It may be due to the interchange effect of charge. It is shown that the droplet can be used for microreactor where transporting, merging etc. of reagents constitute unit operation.

  • PDF

압축하중 및 전계 인가에 따른 PIN-PMN-PT 단결정의 33-모드 유전 및 압전특성 (The 33-mode Dielectric and Piezoelectric Properties of PIN-PMN-PT Single Crystal under Stress and Electric Field)

  • 임재광;박재환;이정호;이상구
    • 마이크로전자및패키징학회지
    • /
    • 제27권4호
    • /
    • pp.91-96
    • /
    • 2020
  • Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3계 압전 단결정의 유전특성과 압전특성을 전계 및 압축응력 인가 조건 하에서 33-모드 방식으로 측정하였다. 110~140℃ 영역에서 저온 rhombohedral 구조에서 고온 tetragonal 구조로의 상전이가 관찰되었으며, cubic 구조로 변화하는 큐리온도는 165℃ 정도로 나타났다. 압축응력 및 전계 변화에 따른 분극의 크기변화를 측정하였다. 전계인가 분극 곡선의 기울기로부터 비유전율을 계산하였고, 인가되는 응력의 크기가 증가할수록 계산된 비유전율의 크기는 증가하고, 인가되는 전계의 크기가 증가할수록 비유전율의 크기는 감소하는 경향성을 나타내었다. 압축응력 및 전계 변화에 따른 변위 거동을 측정하였으며, 곡선의 기울기로부터 압전상수를 계산하였고 압력인가에 따른 상전이를 확인하였다. 수중 또는 의료용 초음파 발진자로 실제 응용할 경우 선형성을 유지하여 구동이 가능하기 위하여 소자 기구물을 형성하는 단계에서 인가하게 되는 압축응력의 크기와 구동 전계의 DC 바이어스의 크기를 적절하게 설계할 필요가 있다.

선대 평판형 플라즈마 반응기에서 NOX 제거에 미치는 자계의 영향 (Effect of Magnetic Field on NOX Removal for Wire-Plate Plasma Reactor)

  • 박재윤;고희석;손성도;이동훈;김종달
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권2호
    • /
    • pp.120-124
    • /
    • 2000
  • In this paper, the effect of magnetic field was measured on NOx(NO+NO2) removal and consumption power for wire-plate plasma reactor with magnetic field applied to electric field vertically. NOx of the simulated diesel engine flue gas were removed by the corona discharge generated by DC, AC and Pulsed voltages in wire-plate reactor. Consumption power increased with discharge voltage. However, when magnetic field was applied to electric field vertically, consumption power slightly decreased. NOx removal rate and arc transition voltage for plasma reactor with magnetic field were higher than those for plasma reactor without magnetic field. Consumption power decreased, however NOx removal significantly increased, when water vapour bubbled by dry air was put into simulated flue gas.

  • PDF