• 제목/요약/키워드: DC Distribution

검색결과 596건 처리시간 0.028초

핀-핀 형 또는 판-판 형 전극에 인가된 AC 전기장이 에틸렌 정상 확산 화염 Soot 입자 배출에 미치는 영향 (Effects of AC Electrostatic Field Applied to fin-to-Pin/Plate-to-Plate Electrodes on Soot Reduction in a C2B4 Normal Diffusion Flame)

  • 이재복;황정호
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1062-1068
    • /
    • 2002
  • In our previous study, it was proven that the mean size and the total number concentration of carbon soot particles emitted from a $C_2$H$_4$ normal diffusion flame decreased when a DC corona was discharged to pin-pin electrodes. In this work the effect of AC corona discharge on soot emission was investigated and compared with that of DC corona discharge. For the pin-pin electrodes the size of soot particles and the number concentration decreased by the AC voltage. There were only slight changes in size distribution with frequencies, while the magnitude of applied voltage was constant. When the electric field was applied to plate-plate electrodes, the size and the number concentration also decreased with the applied AC voltages. For applied voltages above 2kV the effect of frequency increase on the soot emission was effective.

2차원, 2유체 MHD 식을 이용한 플라즈마 디스플레이 판넬의 미소 방전 특성 해석 (Numerical Analysis of Micro-Discharge in Plasma Display Panel Using 2-Fluid, 2-Dimensional MD equations)

  • 최경철;황기웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.911-914
    • /
    • 1992
  • We have investigated the micro-discharge in plasma display panel using 2 dimensional 2 fluid MHD equations. Plasma display utilizes the physical phenomena of the normal glow or abnormal glow and is considered to be able to provide the largest display area among various flat panel. 2 fluid, 2 dimensional Magneto-Hydro-Dynamic equations are applied to Computational field of 100${\times}$800${\mu}m^2$. Time varing glows and after-glows were investigated for 11 $\mu$sec. We obtained the distribution of the microscopic variables such as the density, temperature, velocity of Ne+Ar0.1% gas plasma. During the first 6$\mu$ sec, glow discharge dued to DC pulse was investigated. Time varing phenomena of after-glow was also investigated during the last 5 $\mu$set. From results, it was found that the driving efficiency of a DC Plasma Display Panel could be improved when the diffusion of ions and electrons are controlled by the pulses applied to the auxiliary anode.

  • PDF

컨버터 내장형 LED 가로등 및 보안등의 전기적 특성 분석 (Electrical Characteristics Analysis of LED Lamps using Internal Converter for Road and Street Lighting)

  • 김향곤;길형준;최효상
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.238-244
    • /
    • 2010
  • In this paper, we studied electrical characteristics of internal converter type of LED lamps for road and street lighting. We surveyed electro-technical regulations and KS(Korean industrial standards) about LED luminairs. Waveforms of voltage and current, thermal distributions, insulation resistances between live parts and exposed conductive parts, and flame test of cover of LED lamps were experimented and analyzed. In regulations, insulation resistance between live conductors and exposed conductive parts should be greater than $0.2M{\Omega}$ in case nominal voltage of wiring is 220V. In KS codes, the value of insulation resistance should be greater than $2M{\Omega}$ while applying DC 500V or DC 100V. In the result of this study, waveforms of primary voltage and current were distorted. There was difference in waveforms of secondary voltage and current according to composition of converter. Mostly, insulation resistances were measured high more than regulation and code value but some measured points were measured badly($0.0M{\Omega}$). Cover of LED lamps was ignited easily. We expect that the results of this study would be helpful for revision of regulations and national codes for the electrical safety of LED road and street lighting.

Numerical modeling of dynamic compaction process in dry sands considering critical distance from adjacent structures

  • Pourjenabia, Majid;Hamidi, Amir
    • Structural Engineering and Mechanics
    • /
    • 제56권1호
    • /
    • pp.49-56
    • /
    • 2015
  • Dynamic compaction (DC) is a useful method for improvement of granular soils. The method is based on falling a tamper (weighting 5 to 40 ton) from the height of 15 to 30 meters on loose soil that results in stress distribution, vibration of soil particles and desirable compaction of the soil. Propagation of the waves during tamping affects adjacent structures and causes structural damage or loss of performance. Therefore, determination of the safe or critical distance from tamping point to prevent structural hazards is necessary. According to FHWA, the critical distance is defined as the limit of a particle velocity of 76 mm/s. In present study, the ABAQUS software was used for numerical modeling of DC process and determination of the safe distance based on particle velocity criterion. Different variables like alluvium depth, relative density, and impact energy were considered in finite element modeling. It was concluded that for alluvium depths less than 10 m, reflection of the body waves from lower boundaries back to the soil and resonance phenomenon increases the critical distance. However, the critical distance decreases for alluvium depths more than 10 m. Moreover, it was observed that relative density of the alluvium does not significantly influence the critical distance value.

A New Overlap Current Restraining Method for Current-source Rectifier

  • Qin, Haihong;Liu, Qing;Zhang, Ying;Zhang, Xin;Wang, Dan
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.615-626
    • /
    • 2018
  • To ensure a DC current path and avoid large voltage overshoot of the DC-link inductor, alternating PWM pulses in the current-source rectifier should be supplemented by overlap time, which generates an overlap current and causes input current distortion. In this study, the influence of overlap time is illustrated by comparing the AC-side current before and after overlap time is added. The overlap current distribution caused by overlap time is discussed under different modulation carriers, including triangle carrier, positive-going carrier, and negative-going carrier. The quantitative relationship between the extra harmonics of the AC-side current and overlap time is based on the Fourier analysis. Based on the commutation analysis, a new carrier modulation scheme that can restrain overlap current is proposed. A 3 kW prototype is established to verify the effectiveness of the influence of overlap time and the proposed restraining modulation scheme.

예망어구에서 발생되는 수중음에 관한 연구 (THE SEA NOISE OF THE MOVING TRAWL NET)

  • 윤갑동
    • 한국수산과학회지
    • /
    • 제8권1호
    • /
    • pp.1-6
    • /
    • 1975
  • 복잡하게 운동하고 있는 예망어구에서 발생하는 여러 가지 소음들을 분석 녹음하기 위해 수중 녹음장치를 제작하여 실제 소형 트로올망의 수중소음을 녹음 하였으며, 본 수중 녹음장치는 이동하고 있는 어구에서 발생하는 수중소음을 녹음하는데는 편리하고 효과적이었고 spectrum의 분석 결과는 다음과 같다. 1) 예일중인 트로올망의 수중소음이 주된 음원은 어구의 발줄과 해저와의 마찰에 의한 소음이라는 것을 알았다. 2) 이동중의 트로올망의 수중소음의 주파수 분포는 $DC\~5000\;Hz$이고 그중 우세한 주파수는 약 $500\~700Hz$ 였다. 3) 트로올망의 절대음압의 최대는 50m 수심에서는 약 22 dB이었다.

  • PDF

$\lambda=1.3, 1.55{\mu}m$에서 저분산을 갖는 이중-클래드 광섬유의 설계 (Design of Doubly-Clad Optical Fibers with Low Dispersion for $\lambda=1.3, 1.55{\mu}m$)

  • 정석원;김창민
    • 한국광학회지
    • /
    • 제6권2호
    • /
    • pp.156-164
    • /
    • 1995
  • 광섬유의 스칼라 파동방정식을 토대로 임의의 굴절율 분포를 갖는 광섬유의 분산특성을 해석하였다. 스칼라 파동방정식을 해석하기 위해서 2차 보간함수를 사용한 1차원 유한요소법을 적용하였다. DC형 광섬유를 대상으로 하였으며, 총분산을 최소화할 수 있는 굴절율분포를 조사하였다. $\lambda=1.3, 1.55{\mu}m$두 파장에서 동시에 분산이 거의 0이 되는 설계치를 찾을 수 있었다. 그리고 $\lambda=1.4~1.7{\mu}m$에 걸쳐서 1.0ps/km.nm 이하의 평탄분산특성을 갖고 $\lambda=1.55{\mu}m$에서 0.65ps/km.nm의 분선을 갖는 설계치도 찾을 수 있었다.

  • PDF

고정자 절연파괴 고장에 의한 매입형 영구자석 BLDC 모터의 불가역 감자에 대한 동적해석 알고리즘 (Dynamic Analysis Algorithm of Irreversible Demagnetization of IPM-type Brushless DC Motor by Stator Turn Fault)

  • 이윤석;김경태;허진
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1661-1667
    • /
    • 2013
  • This paper studies the dynamic irreversible demagnetization characteristics of an interior permanent magnet (PM) brushless DC motor with a stator turn fault. A new algorithm, which is a finite element method (FEM) combined with a line voltage equation of the motor, is developed to analyze irreversible demagnetization under dynamic and transient states and considers a stator turn fault. The input current, circulating current, magnetic distribution characteristics, and operating property of the PM, including the irreversible demagnetization in the fault state, are analyzed using this algorithm by considering the magnetic saturation effect. The feasibility of the proposed method confirmed from the analysis results is verified via an experiment. Through this fault analysis, we can accurately check the fault phenomena of a PM motor against the demagnetization fault for fault prevention.

Current-fed Push-Pull type high frequency resonant inverter for wax-sealing

  • Won, Jae-Sun;Kim, Dong-Hee;Ro, Chae-Cyun;Kim, Min-Huei
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.225-230
    • /
    • 2000
  • This paper describes a double-ended current fed push-pull type high frequency resonant inverter used as the power supply for wax-sealing. The proposed inverter can realize ZVS operation by using resonant capacitor to ZVS capacitor and has some merits not only reduction of switch current distribution but also extension of load range compare to the conventional single-ended current fed push-pull type high frequency resonant inverter. This analysis of proposed circuit uses normalized parameter ad characteristic estimation which is needed in each step before design is generally described according to normalized frequency($\mu$), normalized resistance(λ) and parameters. It is also presented as an example of method of the circuit design based on estimation analysis values from theoretical analysis. The theoretical analysis is proved through experiment and this circuit shows that it can be used practically as the power supply system for wax-sealing and DC-DC converter.

  • PDF

Wax-Sealing용 전류형 고주파 공진 인버터의 특성해석에 관한 연구 (A Study on Characteristic Analysis of Current Fed High Frequency Resonant Inverter for Wax-Sealing)

  • 김동희;원재선
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권11호
    • /
    • pp.568-574
    • /
    • 2001
  • This paper describes a current fed high frequency resonant inverter can be used as the power supply for wax-sealing. This circuit configuration is composed of conventional two unit inverter of single ended current find type in parallel. The proposed inverter can realize ZVS operation by using resonant capacitor to ZVS capacitor and has merits not only reduction of switch current distribution but also extension of load range in comparison with the conventional single-ended current fed high frequency resonant inverter. This analysis of proposed circuit uses normalized parameter and characteristic estimation which is needed in each step before design is generally described according to normalized frequency($\mu$), normalized resistance(λ) and parameters. On the basis of characteristic values, a method of the circuit design is presented. Also, the theoretical analysis is proved through experiment and this proposed circuit shows that it can be practically used as the power supply system for wax-sealing and DC-DC converter.

  • PDF