• Title/Summary/Keyword: DC Distribution

Search Result 596, Processing Time 0.027 seconds

A Study on the Characteristic Analysis of Brushless DC Motor Using FEM (유한요소법을 이용한 브러시레스 DC 모터의 특성 해석에 관한 연구)

  • Cheong, Shin-Young;Song, Yu-Seok;Lee, Ju;Jang, Seok-Joong;Park, Geon-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.920-922
    • /
    • 2002
  • This paper investigates the cogging torque reduction in a brushless DC(BLDC) motor having an inner-rotor with surface-mounted segment-type permanent magnets. The kind of magnets for the BLDC motor could have different waveforms of magnetization such as square, trapezoidal and sinusoidal form. This paper discusses the effect of the unsymmetrical magnetization distribution in the segment-type permanent magnet, which is able to obtain through a segment structure that the number of poles per segments is 2 ($N_p/N_s$), on the cogging torque and EMF waveform. Where the existing magnetizer fixture for the square-type magnetization is used to magnetize the magnets in two segment structures of $N_p/N_s$ = 1 and 2. The effectiveness of the proposed designs had been confirmed by comparing cogging torque, and EMF waveform between conventional and new models which are analyzed by Finite Element Method (FEM).

  • PDF

Biased Zero-Error Probability for Adaptive Systems under Non-Gaussian Noise (비-가우시안 잡음하의 적응 시스템을 위한 바이어스된 영-오차확률)

  • Kim, Namyong
    • Journal of Internet Computing and Services
    • /
    • v.14 no.1
    • /
    • pp.9-14
    • /
    • 2013
  • The criterion of zero-error probability provides a limitation on error probability functions being used for adaptive systems when the error samples are shifted by the influence of DC-bias noise. In this paper, we employ a bias term in the error distribution and propose a new criterion of the biased zero-error probability with error being zero. Also, by maximizing the proposed criterion on expanded filter structures, a supervised adaptive algorithm has been derived. From the simulation results of supervised equalization, the algorithm based on the proposed criterion yielded zero-centered and highly concentrated error samples without disturbance in the environments of strong impulsive and DC-bias noise.

Determination of an Underground Seawater Flow Using a TEM Decay Curve (TEM감쇠곡선을 이용한 해수의 지하 유동현상 파악)

  • 황학수;문창규;이상규;이태섭
    • Economic and Environmental Geology
    • /
    • v.34 no.5
    • /
    • pp.499-506
    • /
    • 2001
  • The geophysical monitoring technique using the high resolution time-domain electromagnetic (TEM) method with a coincident loop away was applied for determination of an underground seawater flow in the coastal areas. In comparison of the TEM monitoring to direct current (DC) resistivity monitoring, the TEM response to the under ground seawater flow is less sensitive than the DC resistivity response. However, the TEM monitoring is more effective in terms of measuring time, survey expense, and real-time data processing than the DC monitoring thor evaluating the spatial distribution of the fresh water-seawater transition zone in a regional area.

  • PDF

Distribution of Arbuscular Mycorrhizal Fungi in the Rhizosphere of Cirsium japonicum DC. for Wild Vegetables (나물용 엉겅퀴의 근권에서 Arbuscular 균근균의 분포)

  • Cho, Ja-Yong;Heo, Buk-Gu;Yang, Seung-Yul
    • Korean Journal of Organic Agriculture
    • /
    • v.13 no.2
    • /
    • pp.197-209
    • /
    • 2005
  • of Hangalku per plant sold for wild vegetables were 9.1g and 0.9g, and number of leaves was 10.8. Root fresh and dry weights of Hangalku per plant were 19.2g and 4.1g. Thirty five soil samples were collected from the native soils grown Cirsium japonicum DC., and mycorrhizal spores in soils were separated using wet-sieving methods. Number of mycorrhizal spores per 30g fresh soil sized over 500${\mu}$m, 355~500${\mu}$m, 251~354${\mu}$m, 107~250${\mu}$m and 45~106${\mu}$m were 0.6, 2.1, 6.0, 55.3 and 126, etc. Total number of mycorrhizal spores per 30g fresh soil were 190. Root infection by vesicles, hyphae and arbuscules were 13%, 4% and 3%, respectively. As a result of identification, mass propagated mycorrhizal spores by the host plant of Sudangrass were Glomus sp., Gigaspora sp., and Acaulospora sp., and so on.

  • PDF

New Ground Fault Protective Relay in DC Traction Power System (비접지 DC 급전계통에서 전류형 지락보호계전기의 사용)

  • Chung S.G.;Baek N.W.;Kim Y.S.;Lee S.H.;Lee H.M.
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1297-1302
    • /
    • 2004
  • In DC power distribution system for urban rail transits potential relay, 64P, is used to detect the ground faults. The problem with this 64P is that though it detects the ground fault it cannot identify the faulted region. Therefore the faulted region cannot be isolated properly. It could results in power loss of the trains on the healthy regions and the safety of the passengers in the trains could be affected adversely. A new ground fault protective relaying scheme that can identify the faulted region is presented in this paper. The new concept uses the current differential scheme and the permissive scheme to identify the faulted region correctly. A device with similar characteristic to the arrestor is adapted to use the current relay for the ground fault detection. The role of the device is to block the ground leakage current in normal operating condition and enable the ground fault current to flow in ground fault condition. The algorithm of the new relay and the effect of the newly adapted device in the new relaying scheme are discussed.

  • PDF

Laterally-Driven Electrostatic Repulsive-Force Microactuator (수평구동형 정전반발력 마이크로액추에이터)

  • Lee, Gi-Bang;Jo, Yeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.3
    • /
    • pp.424-433
    • /
    • 2001
  • We present a new electrostatic repulsive-force microactuator using a lateral repulsive force induced by an asymmetric distribution of electrostatic field. The lateral repulsive force has been characterized by a simple analytical equation, derived from a finite element simulation. A set of repulsive force polysilicon microactuators has been designed and fabricated by a 4-mask surface-micromachining process. Static and dynamic micromechanical behavior of the fabricated microactuators has been measured at the atmospheric pressure for a varying bias voltage. The static displacement of the fabricated microactuator, proportional to the square of the DC bias voltage, is obtained as 1.27 $\mu\textrm{m}$ for the DC bias voltage of 140V. The resonant frequency of the repulsive-force microactuator increases from 11.7 kHz to 12.7 kHz when the DC bias voltage increases from 60V to 140V. The measured quality-factor varies from 12 to 13 for the bias volatge range of 60V∼140V. The characteristics of the electrostatic repulsive-force have been discussed and compared and compared with those of the conventional electrostatic attractive-force.

A Study on the Characteristics of High Pressure DC Glow Discharge with a Narrow Gap (좁은 간격의 고압 DC 글로우 방전에서의 방전물성에 관한 연구)

  • Park, Jae-Seong;Jeong, Heui-Seob;Shin, Buhm-Jae;Whang, Ki-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.435-437
    • /
    • 1995
  • It is important to understand tile behaviours of tile high pressure DC glow discharge with a micro gap inside a pixel of the plasmas display panel. We prepared a narrow gap discharge system and have measured electron temperature and density by means of double probe methods in high pressure which was between 100torr and 200torr. And the electrode gap was 7mm. When the pressure varied from 100torr to 200torr, the negative glow was created at a distance less than 1mm from the cathode. And the length of the faraday dark space decreased from 8mm to 5mm. Hence probe measurements was mainly, performed in the region of the Faraday dark space. The dependence of electron temperature and density on the pressure and current density was same with that of the general flow discharge, i.e. as the pressure increased the electron temperature decreased and the density increased. But the spatial electron density distribution in the Faraday dark space was highly distorted because of the effect of high pressure.

  • PDF

An Investigation on DC Electric Field Distribution according to the Material and Configureation of Epoxy Spacer for HVDC GIS (HVDC GIS용 에폭시 스페이서의 재질과 형상에 따른 전계분포 특성 연구)

  • Koo, Jae-Hong;Hwang, Jae-Sang;Kwon, Ik-Soo;Shin, Woo-Ju;Koo, Ja-Yoon;Lee, Bang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1185-1186
    • /
    • 2015
  • 본 논문에서 HVDC $SF_6$ 가스절연시스템(GIS)에서 최적의 에폭시 재질을 알아내기 위해 $Al_2O_3$$SiO_2$ 나노필러가 첨가된 총 다섯 종류의 에폭시에 대한 도전율을 측정하여 DC 전계분포 해석을 수행하였다. 해석결과 $75^{\circ}$의 접촉각(에폭시 스페이서와 도체가 이루는 각도)가 가장 우수한 전계특성을 나타냈고 $Al_2O_3$ 2 hundred per resin(phr)의 나노필러가 첨가된 에폭시가 가장 우수한 절연매질로써의 특성을 보여주었다. 또한, 삼중점에서 전계집중 완화를 위하여 $Al_2O_3$ 2 phr의 나노필러가 첨가된 에폭시의 데이터를 기반으로 열해석을 고려한 정상상태 및 극성 반전에 대해 DC 전계 해석을 수행하여 최적의 에폭시 스페이서 형상을 도출하였다.

  • PDF

Analysis of Vibration due to Magnetic Exciting Force in the Brushless DC Motor (브러시리스 직류 전동기의 자기 가진력에 의한 진동 해석)

  • Han, Ki-Jin;Cho, Han-Sam;Jung, Hyun-Kyo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.1
    • /
    • pp.1-9
    • /
    • 2001
  • In this paper, the general research on the analysis of the vibration due to magnetic exciting force in the small brushless DC(BLDC) motor, which is used in the Digital Versatile Disk(DVD) ROM driving system, is performed. The first part of the study is the analysis of the magnetic exciting force in the air gap region. As a verification of the exciting force by numerical analysis, the magnetic exciting force distribution in the air gap region is computed by using Reluctance Network Method(RNM). In addition, the effect of the eccentricity on the magnetic exciting force is discussed. The other part of the research is the structural analysis of the rotor structure of the BLDC motor. The matural mode analysis of the rotor structure is performed, and the vibration response due to magnetic exciting force is found. As a result of the procedures, the basic estimation of the effect of the magnetic exciting force on the vibration of BLDC motor is suggested.

  • PDF

A Study of DC/AC Characteristics on 22.9 kV distribution class HTS-cable (22.9 kV 배전급 초전도케이블의 DC/AC 특성에 관한 연구)

  • Ma, Y.H.;Ryu, K.;Sohn, S.H.;Lim, J.H.;Hwang, S.D.;Choi, H.O.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.287-287
    • /
    • 2008
  • HTS-케이블은 구리도체 대신 고온초전도도체를 사용하여 저항이 0이 되는 초전도현상을 이용하여 대용량 전력수송이 가능한 전력케이블로서 대도시의 전력부하 집중문제를 해결할 수 있는 환경 친화적 전력케이블이다. 최근 고온초전도선재의 고임계전류밀도화 및 장척화에 힘입어 HTS-케이블의 실용화를 목표로 경제성이 있는 전력케이블을 개발하려는 움직임뿐만 아니라 실증시험 등 활발한 연구가 진행 중이다. 그러나 초전도전력케이블에서 발생되는 교류손실은 케이블의 효율을 저하시킬 뿐만 아니라 냉동기비용 증가로 인한 기존 케이블과의 가격경쟁에서 경제성을 저하시키는 주된 요인으로 작용하기 때문에 이의 상용화에 앞서 교류손실에 대한 정확한 규명이 되어야 하며 또한 실계통 투입 시 중요한 선로임피던스에 대한 정확한 규명도 필요하다. 본 논문에서는 실제 한전 주관으로 고창시험장에 설치된 배전급 22.9 kV, 100 m, 50 MVA급 3 상 HTS-케이블에 대한 통전특성을 규명하기 위하여 먼저 HTS-케이블의 DC 통전특성을 조사하였다. 또한 3상평형운전상태에서 AC 통전특성(인덕턴스 및 교류손실)을 실험적으로 조사하였으며 5m-케이블에서 측정된 결과와 비교 검토하였다.

  • PDF