• Title/Summary/Keyword: DC Circuit

Search Result 2,003, Processing Time 0.031 seconds

Design of RE-DC conversion circuit for the batteryless Transponder

  • Jin, In-su;Yang, Kyeong-rok;Ryu, Hyoung-sun;Kim, Yang-mo
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.1001-1004
    • /
    • 2000
  • RFID system is applied to identify, locate and track people, cars, animals. In RFID system, the passive transponder without battery has some benefits than active transponder, such as no restriction in battery exchange and in battery’s life. But it needs auxiliary RF-DC conversion circuit. RF-DC conversion circuit originated from Wireless Power Transmission (WPT). In this paper, RF-DC conversion circuit consists of a microstrip patch antenna and impedance matching circuit, Cock-croft Walton circuit. And RF-DC conversion circuits have two kinds of T-type and Cross-type impedance matching circuits.

  • PDF

Development of A DC Motor Controller for 24V-500W Small Electric Vehicle (24V-500W급 소형전동차용 DC모터 속도 콘트롤러 개발)

  • Bang, Jun-Ho;Lee, Woo-Choun;Yu, Jae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1777-1783
    • /
    • 2012
  • In this paper, a new motor driving circuit is designed to improve the output performance of DC motor, and a controller is developed with the designed circuit. By the designed driving circuit, a controller can continuously drive DC motors by a transformer which has switching signals of a self-generated circuit to operate it. And while the DC motor have a maximum velocity, the reference voltage can be maintained higher value than that of triangle voltage and it makes the DC motor driving transistor ON and maximum power. A 24V-500W DC motor controller is developed with the proposed motor driving circuit, and also a small electric car is made and the driving test of it is executed. The test results shows that it can continuously control go and back speed of motor with 12A driving current. And also, it is verified that the over current and heat detecting function is operating correctly and the rest value of the used battery can be displayed as 6 step from 20 to 100%.

New DC/AC Soft Switched PWM Converter Having a DC-Link Commutation Circuit (직류측에 Commutation 회로를 갖는 영전압 스위칭 PWM 인버터)

  • Chung, J.H.;Park, S.S.;Goo, T.H.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1158-1160
    • /
    • 1992
  • A new dc/ac soft switched PWM convert having a dc-link commutation circuit is proposed. The commutation circuit implemented by utilizing a series resonant circuit while preparing for zero voltage switching of primary inverter. The converter provides both variable pulse width and position which is fundamentally different than converters. In this paper, the operating principles, design and control considerations analysis of a such a soft switched converter is analyzed.

  • PDF

Design of a Voltage Protection Circuit for DC-DC Converter of the Potable Device Application (소형 휴대기기용 DC-DC 변환기를 위한 전압 보호회로 설계)

  • Park, Ho-Jong;Heo, Yun-Seok;Park, Yong-Su;Kim, Nam-Tae;Song, Han-Jung
    • 전자공학회논문지 IE
    • /
    • v.49 no.1
    • /
    • pp.18-23
    • /
    • 2012
  • In this paper, a potable device application for DC-DC converter was designed for voltage protection circuit. Voltage protection circuit to offer the under voltage lock out and over voltage protection consists of a comparator and bais circuits were implemented using. XFAB 1um CMOS process, SPICE simulations was confirmed through the characteristics. Simulation results, under voltage lock out input voltage is 4.8 V higher when the turn-on and, 4.2 V less when turn-off. When the input voltage is low voltage is applied can be used to prevent malfunction of the circuit. Over voltage protection is 3.8 V reference voltage when the output voltage caused by blocking circuit prevents device destruction can be used to improve the stability and reliability. The virtual control circuits of the DC-DC converter connected. According to the results of the abnormal voltage, voltage protection circuit behavior was confirmed. The proposed voltage protection circuit of the DC-DC converter cell is useful are considered.

Protection of the MMCs of HVDC Transmission Systems against DC Short-Circuit Faults

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.242-252
    • /
    • 2017
  • This paper deals with the blocking of DC-fault current during DC cable short-circuit conditions in HVDC (High-Voltage DC) transmission systems utilizing Modular Multilevel Converters (MMCs), where a new SubModule (SM) topology circuit for the MMC is proposed. In this SM circuit, an additional Insulated-Gate Bipolar Translator (IGBT) is required to be connected at the output terminal of a conventional SM with a half-bridge structure, hereafter referred to as HBSM, where the anti-parallel diodes of additional IGBTs are used to block current from the grid to the DC-link side. Compared with the existing MMCs based on full-bridge (FB) SMs, the hybrid topologies of HBSM and FBSM, and the clamp-double SMs, the proposed topology offers a lower cost and lower power loss while the fault current blocking capability in the DC short-circuit conditions is still provided. The effectiveness of the proposed topology has been validated by simulation results obtained from a 300-kV 300-MW HVDC transmission system and experimental results from a down-scaled HVDC system in the laboratory.

Two-Switch Auxiliary Resonant DC Link Snubber-Assisted Three-Phase Soft Switching PWM Sinewave Power Conversion System with Minimized Commutation Power Losses

  • Nagai, Shinichiro;Sato, Shinji;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.249-258
    • /
    • 2003
  • This paper presents a high-efficient and cost effective three-phase AC/DC-DC/AC power conversion system with a single two-switch type active Auxiliary Resonant DC Link (ARDCL) snubber circuit, which can minimize the total power dissipation. The active ARDCL snubber circuit is proposed in this paper and its unique features are described. Its operation principle in steady-state is discussed for the three phase AC/DC-DC/AC converter, which is composed of PWM rectifier as power factor correction (PFC) converter, sinewave PWM inverter. In the presented power converter system not only three-phase AC/DC PWM rectifier but also three-phase DC/AC inverter can achieve the stable ZVS commutation for all the power semiconductor devices. It is proved that the proposed three-phase AC/DC-DC/AC converter system is more effective and acceptable than the previous from the cost viewpoint and high efficient consideration. In addition, the proposed two-switch type active auxiliary ARDCL snubber circuit can reduce the peak value of the resonant inductor injection current in order to maximize total system actual efficiency by using the improved DSP based control scheme. Moreover the proposed active auxiliary two-switch ARDCL snubber circuit has the merit so that there is no need to use any sensing devices to detect the voltage and current in the ARDCL sunbber circuit for realizing soft-switching operation. This three-phase AC/DC-DC/AC converter system developed for UPS can achieve the 1.8% higher efficiency and 20dB lower conduction noise than those of the conventional three-phase hard-switching PWM AC/DC-DC/AC converter system. It is proved that actual efficiency of the proposed three-phase AC/DC-DC/AC converter system operating under a condition of soft switching is 88.7% under 10kw output power.

An Improved Topology of DC Circuit Breaker Based on Inverse Current Injection Method (역전류 주입방식기반의 DC차단기의 개선된 토폴로지)

  • Cho, Young-Bae;Son, Ho-Ik;Kim, Hak-Man;Kwak, Joosik;An, Yong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1491-1496
    • /
    • 2014
  • VSC-HVDC system is vulnerable to a DC fault because the fault current can be injected from AC system to DC system during the fault. Therefore, DC circuit breaker is required to isolate faults in VSC-HVDC system. The inverse current injection method of circuit breaker has been considered as DC circuit breaker. However, the topology has drawback that the breaking time is longer than hybrid circuit breaker using semiconductor devices. In order to solve this problem, this paper proposes an improved topology of circuit breaker based on inverse current injection method. In addition, the proposed topology will be compared with the existing topology. And we will verify its effects by using the simulation results.

Optimal Soft-Switching Scheme for Bidirectional DC-DC Converters with Auxiliary Circuit

  • Lee, Han Rim;Park, Jin-Hyuk;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.681-693
    • /
    • 2018
  • This paper proposes a soft-switching bidirectional dc-dc converter (BDC) with an auxiliary circuit. The proposed BDC can achieve the zero-voltage switching (ZVS) using an auxiliary circuit in the buck and boost operations. The auxiliary circuit supplies optimal energy for the ZVS operation of the main switches. The auxiliary circuit consists of a resonant inductor, a back-to-back switch and two capacitors. A small-sized resonant inductor and an auxiliary switch with a low-rated voltage can be used in the auxiliary circuit. Zero-current switching (ZCS) turn-on and turn-off of the auxiliary switches are possible. The proposed soft-switching scheme has a look-up table for optimal switching of the auxiliary switches. The proposed strategy properly adjusts the turn-on time of the auxiliary switch according to the load current. The proposed BDC is verified by the results of PSIM simulations and experiments on a 3-kW ZVS BDC system.

Three-Phase PWM Inverter and Rectifier with Two-Switch Auxiliary Resonant DC Link Snubber-Assisted

  • Nagai Shinichiro;Sato Shinji;Matsumoto Takayuki
    • Journal of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.233-239
    • /
    • 2005
  • In this paper, a new conceptual circuit configuration of a 3-phase voltage source, soft switching AC-DC-AC converter using an IGBT module, which has one ARCPL circuit and one ARDCL circuit, is presented. In actuality, the ARCPL circuit is applied in the 3-phase voltage source rectifier side, and the ARDCL circuit is in the inverter side. And more, each power semiconductor device has a novel clamp snubber circuit, which can save the power semiconductor device from voltage and current across each power device. The proposed soft switching circuits have only two active power semiconductor devices. These ARCPL and ARDCL circuits consist of fewer parts than the conventional soft switching circuit. Furthermore, the proposed 3-phase voltage source soft switching AC-DC-AC power conversion system needs no additional sensor for complete soft switching as compared with the conventional 3-phase voltage source AC-DC-AC power conversion system. In addition to this, these soft switching circuits operate only once in one sampling term. Therefore, the power conversion efficiency of the proposed AC-DC-AC converter system will get higher than a conventional soft switching converter system because of the reduced ARCPL and ARDCL circuit losses. The operation timing and terms for ARDCL and ARCPL circuits are calculated and controlled by the smoothing DC capacitor voltage and the output AC current. Using this control, the loss of the soft switching circuits are reduced owing to reduced resonant inductor current in ARCPL and ARDCL circuits as compared with the conventional controlled soft switching power conversion system. The operating performances of proposed soft switching AC-DC-AC converter treated here are evaluated on the basis of experimental results in a 50kVA setup in this paper. As a result of experiment on the 50kVA system, it was confirmed that the proposed circuit could reduce conduction noise below 10 MHz and improve the conversion efficiency from 88. 5% to 90.5%, when compared with the hard switching circuit.

A Study on High Efficiency OBC with Wide Range Output Using Isolated Current-Fed PFC Converter (절연형 전류원 PFC 컨버터를 사용한 넓은 출력범위를 가지는 고효율 OBC에 대한 연구)

  • Kim, Hyung-Sik;Kim, Hee-Jun;Ahn, Joon-Seon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.1
    • /
    • pp.99-105
    • /
    • 2019
  • OBC for battery charging of electric vehicles mainly consist of two stages including PFC circuit and isolated DC-DC converter circuit. In general, a non-isolated boost converter is used as the PFC circuit, and a resonant converter capable of ZVS (zero voltage switching) is used as the isolated DC-DC converter. In this paper, we propose an OBC composed of isolated current-fed type PFC circuit and buck DC-DC converter. The proposed OBC is easy to configure the circuit and controller, and can cope with a wide output range. In order to verify the validity of the proposed circuit, a prototype 3.3 ㎾ class prototype was fabricated. As a result, the maximum efficiency and the maximum power factor of 99.2% were confirmed under the operational stability and rated load conditions at the output voltage of 150V ~ 400V.